Inversion Recovery Pulse Sequences MRI | STIR and FLAIR | MRI Physics Course #19

  Рет қаралды 17,763

Radiology Tutorials

Radiology Tutorials

Күн бұрын

High yield radiology physics past paper questions with video answers
Perfect for testing yourself prior to your radiology physics exam 👇
➡️ X-RAY, ULTRASOUND AND MRI BUNDLE (SAVE over 25%): www.radiologyt...
➡️ X-RAY QUESTION BANK: www.radiologyt...
➡️ ULTRASOUND QUESTION BANK: www.radiologyt...
➡️ MRI QUESTION BANK: www.radiologyt...
=========================
I have also created two RADIOPAEDIA LEARNING PATHWAYS
bit.ly/radiopa... (👈 25% OFF DISCOUNT LINK)
WHAT’S INCLUDED?
✅This KZfaq series Ad free
✅Constantly updated Radiopaedia articles
✅Summary slides
✅Key take home bullet points throughout
✅Multiple review quizzes
✅Short answer review questions
✅Official Radiopaedia course completion certificate
25% discount using this link: bit.ly/radiopa...
=========================
Having reviewed spin echo and gradient echo pulse sequences, let's turn our attention to inversion recovery pulse sequences. Inversion recovery sequences serve to null signal coming from tissues with a predetermined T1 relaxation constant.
A 180 degree radiofrequency pulse the net magnetisation vector into the antiparallel longitudinal plane. Once the RF pulse is switched off the spins will regain longitudinal magnetisation at different rates (depending on the T1 of the tissue). At certain intervals specific tissue will have a net zero longitudinal magnetisation. If a 90 degree radiofrequency pulse is applied at this interval (time of inversion) there will be no signal in the transverse plane from that particular tissue.
This is the basis for signal suppression in inversion recovery pulse sequences.
=========================
SIGN UP TO MY MONTHLY EMAIL NEWSLETTER 👉 bit.ly/3ruLh3d
Not sure if the question banks are for you?
If you're here, you're likely studying for a radiology physics exam. I've spent the last few months collating past papers from multiple different countries selecting the most commonly asked questions. You'll be surprised how often questions repeat themselves!
The types of questions asked in FRCR, RANZCR AIT, ARRT, FC Rad Diag (SA), ABR qualifying Core Physics and MICR part 1 are surprisingly similar and the key concepts remain the same throughout. I've taken the most high-yield questions and answered them in video format so that I can take you through why certain answers are correct and others are not.
Happy studying,
Michael
#radiology #radres #FOAMrad #FOAMed

Пікірлер: 44
@pmac5139
@pmac5139 10 ай бұрын
These lectures are so concise and easy to understand. Thank you.
@radiologytutorials
@radiologytutorials 10 ай бұрын
This makes me so happy! Thank you. I’m really trying to make it as simple as possible. Glad it’s been helpful 🙂
@dr.albertmir
@dr.albertmir 3 ай бұрын
Incredible video. Thank you very much.
@ames1988
@ames1988 10 ай бұрын
Thank you so much for the excellent lectures! Can you also cover spin lock, T1rho relaxation, and adiabatic concepts?
@ruviniratnayaka6234
@ruviniratnayaka6234 7 ай бұрын
Great, Amazing talk. Thank you very much..
@radiologytutorials
@radiologytutorials 7 ай бұрын
So glad you enjoyed it!
@isasacic2917
@isasacic2917 10 ай бұрын
Fantastic content! Thank you from Sweden!
@radiologytutorials
@radiologytutorials 10 ай бұрын
Thanks @isasacic2917! Love knowing where everyone is from 🥰
@jonathanmcintire6818
@jonathanmcintire6818 10 ай бұрын
I've been trying to understand the mechanism of action surrounding the null point in the IR sequence. And I've been trying to reconcile the quantum mechanic principle of basically having no way to know where something is in space, with the magnetic vector that can be predicted due to accumulation of many protons in their predicted state. It's helped me realize that the transverse magnetic vector is a result of the stimulated coherent precession, and that without stimulation from the RF pulse, there is no coherence. Which means T1 recovery, by nature, isn't coherent recovery, so the magnetic vector doesn't "swing back" through the transverse plane. So my question is, if my previous statements are correct and apply, is the null point essentially the quantum mechanical point in time where we have no way of predicting where the spins are, because they are, in that moment, not influenced by any external forces? And thus there is a net zero magnetic vector? Or is there a magnetic vector that still exists but no component of it exists in the longitudinal plane? Thanks in advance for your time with my questions!
@aanwary
@aanwary 4 ай бұрын
Thanks Michael 👏
@fazaltahir4216
@fazaltahir4216 10 ай бұрын
Superb lecture, thanks a lot 🎉
@radiologytutorials
@radiologytutorials 10 ай бұрын
Cheers Fazal 👍🏼🙏🏻
@fazaltahir4216
@fazaltahir4216 10 ай бұрын
@@radiologytutorials ❤️
@mitpatel8133
@mitpatel8133 2 ай бұрын
There is one small mistake at around 9 min you said when we apply 90 RF pulse we are going to loose all trans mag but we lost long mag.
@nadeem822
@nadeem822 10 ай бұрын
One of thae important topics 🙏
@nadeem822
@nadeem822 10 ай бұрын
Thank you sir always great explanation ❤
@radiologytutorials
@radiologytutorials 10 ай бұрын
Thanks for your support 🤗
@fatimahabeeb198
@fatimahabeeb198 8 ай бұрын
شكرا للشرح
@Ainz18
@Ainz18 9 ай бұрын
Bravo!
@beyondrepair5616
@beyondrepair5616 10 ай бұрын
Thank you!
@radiologytutorials
@radiologytutorials 10 ай бұрын
Thank you for watching 😀
@user-tb6bd1jl3p
@user-tb6bd1jl3p 10 ай бұрын
Thankyou❤❤
@karlmoody4891
@karlmoody4891 2 ай бұрын
Amazing lectures through and through! I might be mistaken here, but at the 9:00 mark, didn't you mean to mention longitudinal instead of transverse?
@user-re4cz8gr9u
@user-re4cz8gr9u 10 ай бұрын
Thankyou micheal sir
@user-eh8uo1pi5u
@user-eh8uo1pi5u 10 ай бұрын
Thankyou 🎉🎉
@radiologytutorials
@radiologytutorials 10 ай бұрын
You’re welcome 😊
@kess562
@kess562 10 ай бұрын
Please release MRI question banks
@mohsinshehzad4031
@mohsinshehzad4031 10 ай бұрын
Honourable sir Need Computed tomography physics lectures also. Thanks in Advance Sir
@radiologytutorials
@radiologytutorials 10 ай бұрын
Hi @mohsinshehzad4031- I'm working on finishing the MRI series at the moment, but hopefully CT is not too far behind!
@yrusb
@yrusb 10 ай бұрын
12:32 I´ve got a question: In order to get the 180° flip angle (,so minus 100% the initial longitudinal magnetization), don´t we pretty much push all the spins to a spin down state? Wouldn´t that mean that we can´t go any further than 180° from that point? I mean, flipping a certain tissue from 180° back into the transverse plain would basically mean that we push that tissue further from 180°, 270° around. But in order to do that, we´d need to excite more than all of the spins which is obviously impossible. Only way I can think of is that we excite the tissue in such a manner that we push the spins of the tissue in question out of the spin down phase by starting a pulse that would be absorbed by spin down atoms, but in order to conserve the energy they´d have to give up energy (which will probably result in heating up the surrounding body parts). So, we excite spin down state atoms further and as far as I know, that is impossible (other wise , fat sat wouldn´t work). How can we flip spins from 180° back into the transverse plane? I mean it´s being done so there must be a way to do that, but I don´t really understand how bc from my current physical perspective that should be impossible bc of the aforementioned reasons...
@vohuynhminhtuanvng
@vohuynhminhtuanvng 5 ай бұрын
Mister, Are u still there? Have u had the answers yet?
@yrusb
@yrusb 5 ай бұрын
@@vohuynhminhtuanvng Still here, still no idea ... No rhyme intended
@vohuynhminhtuanvng
@vohuynhminhtuanvng 4 ай бұрын
@@yrusb do you have any means for communication such as facebook or telegram?? We have the same interest in principle of MRI, this makes me delighted
@vohuynhminhtuanvng
@vohuynhminhtuanvng 4 ай бұрын
@@yrusb In my point of view, Disparity between Spin up and spin down state will determine the amount of signal that could be caught by Receiver coil. The 180° pulse will push all this spin (residual amount of the subtraction between spin-up and spin-down) into the negative -z axis. Simarily, the 90° pulse will cause the equality between this two state. This also lead me stuck deeply into another problem. The pulse that further than 180° will cause more change of amount of each state or else.
@yrusb
@yrusb 3 ай бұрын
@@vohuynhminhtuanvng Hey sorry for answering so late, I had a million things going on in the past few weeks but things will hopefully be a little bit calmer for now If you still want to, we can exchange e-mail addresses first and then we can exchange phone numbers and communicate via signal or find another mean to communicate 😊I just don´t want to post my phone number in public (Just to avoid confusion as for when I´m actually online and since you´re probably from the US - I´m from Germany and hence probably in another time zone)
@rrozinak
@rrozinak 9 ай бұрын
Thank you for your amazing videos. I don't understand one thing though - for the STIR and FLAIR sequences you have images with TR at 90. Shouldn't the new repetition start with 180 again?
@mudangayu1729
@mudangayu1729 Ай бұрын
180 is just an extra inversion pulse we're using. 90 degree is the excitation RF pulse, therefore the TR is counted only from 1 excitation pulse to the next, not 1 inversion pulse to next
@user-gh9qr5oi9q
@user-gh9qr5oi9q 10 ай бұрын
Thankyou❤❤
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 43 МЛН
Get 10 Mega Boxes OR 60 Starr Drops!!
01:39
Brawl Stars
Рет қаралды 16 МЛН
Они так быстро убрались!
01:00
Аришнев
Рет қаралды 3,1 МЛН
The Insane Engineering of MRI Machines
17:53
Real Engineering
Рет қаралды 3 МЛН
Denis Noble explains his revolutionary theory of genetics | Genes are not the blueprint for life
14:33
The Clever Way to Count Tanks - Numberphile
16:45
Numberphile
Рет қаралды 982 М.
DWI vs ADC MRI sequences: EXPLAINED
17:59
Radiology Tutorials
Рет қаралды 48 М.
Germinal Matrix Haemorrhage | Cranial Ultrasound | Registrar Sessions
10:25
Radiology Tutorials
Рет қаралды 6 М.
What Darwin won't tell you about evolution - with Jonathan Pettitt
48:32
The Royal Institution
Рет қаралды 271 М.
Introducing MRI: Inversion Recovery (35 of 56)
40:53
Albert Einstein College of Medicine
Рет қаралды 68 М.
MRI physics overview | MRI Physics Course | Radiology Physics Course #1
23:13
Radiology Tutorials
Рет қаралды 135 М.
MRI,T2,T1,Flair ,DWI
10:53
CT Scan & MRI
Рет қаралды 110 М.
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 43 МЛН