IR value testing of transformer

  Рет қаралды 35,988

Electro Gyan

Electro Gyan

2 жыл бұрын

Пікірлер: 74
@bhimaraolimbalkar5815
@bhimaraolimbalkar5815 Ай бұрын
Ok, sir
@skbdigitalinfo5503
@skbdigitalinfo5503 11 ай бұрын
Make video on How many types of protection are using in power transformers. Explanation about that
@electrogyan6240
@electrogyan6240 11 ай бұрын
Okay
@nandtechvlog1198
@nandtechvlog1198 8 ай бұрын
Thanks sir nice video
@AmitSharma-pu1lz
@AmitSharma-pu1lz 10 ай бұрын
Bigot bahtreen video sir bohot dhanayvaad sir❤
@electrogyan6240
@electrogyan6240 10 ай бұрын
Thanks for watching
@shahzadmallick6961
@shahzadmallick6961 9 ай бұрын
Great teaching skill sir
@electrogyan6240
@electrogyan6240 9 ай бұрын
Thanks for watching
@prashantverma45
@prashantverma45 3 ай бұрын
Nicely explained.
@electrogyan6240
@electrogyan6240 3 ай бұрын
Thank for watching
@allabakshmegalmani9322
@allabakshmegalmani9322 Ай бұрын
Bahut badhiya Sir .. Aapne bataya ki lv to earth ki value 1.4Mohms ya us se jyada ani chahiye aur hv to earth ki 12 M ohms .... mujhe yeh jan na hai ki hv to lv test jab karte hai uski value kya ani chahiye ...
@electrogyan6240
@electrogyan6240 Ай бұрын
Minimum 12 megaoms
@rohailmohmand502
@rohailmohmand502 6 ай бұрын
welldone sir
@electrogyan6240
@electrogyan6240 6 ай бұрын
Thank for watching
@sanjaykumar-un2ed
@sanjaykumar-un2ed 7 ай бұрын
nice
@Devendrakumarpankaj
@Devendrakumarpankaj Жыл бұрын
Guard terminal ko ground se lgate hai for safety purpose
@srinivaspuram2955
@srinivaspuram2955 Жыл бұрын
THANK YOU SIR NICE VIDEO
@rajukumarthakur8491
@rajukumarthakur8491 Жыл бұрын
Sir motor me ir cheak karna hoga to motor star me ya delta me rahega
@neelamsharma615
@neelamsharma615 2 жыл бұрын
Very nice video
@techinfotahir7912
@techinfotahir7912 11 ай бұрын
Bahoot achi Vedio hai.hipot machine sy bhi sir Kiya ham test kr saktay hain kisi transformer ko aor kitnay volts dyngy
@electrogyan6240
@electrogyan6240 11 ай бұрын
Only test with insulation tester
@Life-Adventures-99
@Life-Adventures-99 Жыл бұрын
Lt side ki ager neutral bhi short ker denge .... Tab to yeh 0 value dega Neutral phle disconnect krna pdta hai rest short and then check with earth
@abdulkalam3164
@abdulkalam3164 8 ай бұрын
sir please make live video demo
@electrogyan6240
@electrogyan6240 8 ай бұрын
Ok I will do it
@waheedislam2989
@waheedislam2989 Жыл бұрын
Sir ..ager practically ho then it will much better
@DA-bw7bt
@DA-bw7bt Жыл бұрын
Lt side neutral ko alag karna padta hai tabhi reading ayega
@drthimachali8671
@drthimachali8671 Жыл бұрын
Sir inko short karke kyu lete hai ir
@salimahmad9974
@salimahmad9974 4 ай бұрын
AAP ne hv-lv ki testing me value nahi batai kitna ohm aana chahiye
@electrogyan6240
@electrogyan6240 4 ай бұрын
Minimum 12 megaoms
@mohankumarsubramani7597
@mohankumarsubramani7597 Ай бұрын
Hi , why you shorting the phases during megger ? They already inside star or delta ? Please explain
@electrogyan6240
@electrogyan6240 Ай бұрын
Reduce time in labour
@electrogyan6240
@electrogyan6240 Ай бұрын
You will testing each fase separate also
@mohankumarsubramani7597
@mohankumarsubramani7597 Ай бұрын
@@electrogyan6240 Thank you 🙏
@badshahengineeringvlogs9718
@badshahengineeringvlogs9718 2 ай бұрын
HV to LV test me hum LV ko Earth nahe karte
@electrogyan6240
@electrogyan6240 2 ай бұрын
Disconnect ground wire from star point before testing of HV-LV testing
@abhiranjankumar528
@abhiranjankumar528 2 жыл бұрын
Good
@electrogyan6240
@electrogyan6240 2 жыл бұрын
Thanks for watching
@abhaysonawane32
@abhaysonawane32 6 ай бұрын
22kav ka IR kaise nikalege
@electrogyan6240
@electrogyan6240 6 ай бұрын
Follow as per video
@jaiganeshsharma8683
@jaiganeshsharma8683 2 жыл бұрын
Nice
@electrogyan6240
@electrogyan6240 2 жыл бұрын
Thanks for watching
@user-fl9mw9di7v
@user-fl9mw9di7v 4 ай бұрын
10:30 Sir , Transformer ke HV - LV IR value minimum kitni Aani chahiye ? HV - E aur LV - E mein minimum IR kitni Aani chahiye woh to Aapne bataya hua hai .
@electrogyan6240
@electrogyan6240 4 ай бұрын
HV - E 12 megaoms, LV - E 2 megaoms
@user-fl9mw9di7v
@user-fl9mw9di7v 4 ай бұрын
@@electrogyan6240 Sir , Main yeh poochh raha hoon ki HV - LV minimum IR value kitni aani chahiye ? Aap jo HV - E 12 Megaohms aur LV - E 1.4 Megaohms bataye hain original video mein woh samajh mein aa rahi hai Sir jo ki 1 Megaohm per kV hai . Main poochh raha hoon HV - LV minimum kitni IR aani chahiye ?
@electrogyan6240
@electrogyan6240 4 ай бұрын
Minimum 12 megaoms
@user-fl9mw9di7v
@user-fl9mw9di7v 4 ай бұрын
@@electrogyan6240 Samjha Sir , HV Winding involved means kV+1rule ke hisaab se hi minimum IR aani chahiye phir chahe woh HV - E ho ya phir HV - LV . Yahi hai na Sir , Kripya confirm kijiye .
@electrogyan6240
@electrogyan6240 4 ай бұрын
@@user-fl9mw9di7v Yes
@naseelp61
@naseelp61 Жыл бұрын
HV-LV minimum IR value kithna hoga?
@electrogyan6240
@electrogyan6240 Жыл бұрын
1+ kv
@rajgtasgaon
@rajgtasgaon Жыл бұрын
KESE LIYA JATA HE O SAMJ AAYA IR VALUES RIPORT KESE BANAYA JATA HE AUR MAGNETIC, VECTOR GROUP KA BHI BATYE
@electrogyan6240
@electrogyan6240 Жыл бұрын
Okay I will make a video this topic
@mdimamhasan8030
@mdimamhasan8030 Жыл бұрын
Dear Sir, After how much time to select the reading ?
@electrogyan6240
@electrogyan6240 Жыл бұрын
If reading is stable
@RajkumarYadav-ql1hi
@RajkumarYadav-ql1hi Жыл бұрын
3 phase motar ki minimum value ky honi chahiye
@electrogyan6240
@electrogyan6240 Жыл бұрын
Depend motor input voltage
@ranjanbehera6313
@ranjanbehera6313 5 ай бұрын
Why are testing hv to lv ir value
@electrogyan6240
@electrogyan6240 5 ай бұрын
For HT voltage leakage in LT side
@electrogyan6240
@electrogyan6240 5 ай бұрын
This is more dangerous and failure all electrical equipment
@sujitprusty9995
@sujitprusty9995 Жыл бұрын
HV to LV minimum value kitna ana chahiye
@electrogyan6240
@electrogyan6240 Жыл бұрын
If in put volt 11 kv = 12 Mega ohms if in put volt 33 kv = 34 mega ohms
@Devendrakumarpankaj
@Devendrakumarpankaj Жыл бұрын
Bhai sahab ye galat tarika kha se seekha hai
@Chaggars
@Chaggars 2 жыл бұрын
Thanks sir.
@electrogyan6240
@electrogyan6240 2 жыл бұрын
Thanks
@srinivaspuram2955
@srinivaspuram2955 Жыл бұрын
SIR CAN YOU PLAESE EXPLAIN 11 KV HT SIDE DROP OUT FUSESES FREQUENTLY GONE & HOW CAN I CHOOSE 11 KV SIDE FUSE RATING THANKS FOR ADVANCE
@electrogyan6240
@electrogyan6240 Жыл бұрын
We do HT site fuse rating selection according to the full load HT current
@srinivaspuram2955
@srinivaspuram2955 Жыл бұрын
@@electrogyan6240 tq sir
@jethisagar9391
@jethisagar9391 2 жыл бұрын
LV-E HV-E HV-LV Kitna voltage apply Krna he ?
@electrogyan6240
@electrogyan6240 2 жыл бұрын
See complete video
@riddhisharma6392
@riddhisharma6392 Жыл бұрын
see video
@riddhisharma6392
@riddhisharma6392 Жыл бұрын
see video
@rasmiarora7571
@rasmiarora7571 9 ай бұрын
Phle sek kr aaa . Fer video bna . Tek he .
@electrogyan6240
@electrogyan6240 9 ай бұрын
Tu pahle bolane ka Tarika Sikh kar aa
IR and WR test क्यू किया जाता हे?
12:14
Gyaan ELECTRICAL
Рет қаралды 33 М.
孩子多的烦恼?#火影忍者 #家庭 #佐助
00:31
火影忍者一家
Рет қаралды 52 МЛН
Red❤️+Green💚=
00:38
ISSEI / いっせい
Рет қаралды 74 МЛН
Why DC Voltage Is Used In IR test/Megger test???
3:39
AJ Electrical Gyaan
Рет қаралды 11 М.
Transformer Training By Skilled Hindustan
16:47
Skilled Hindustan
Рет қаралды 1 МЛН
Transformer IR Value Test || Hindi
15:47
Insight Tecs
Рет қаралды 15 М.
Electron flow vs conventional current. | How do 1000 million electrons flow inside wire?
7:49
Duonode | Science and research.
Рет қаралды 1,4 МЛН