No video

Kitchen Hood Suppression System Maintenance Explainer Video (Argus Fire)

  Рет қаралды 51,877

Screen Grab

Screen Grab

Күн бұрын

Пікірлер: 30
@Digitaltarangs
@Digitaltarangs 6 ай бұрын
Great, Thanks for sharing knowledge...
@EricPham-gr8pg
@EricPham-gr8pg 8 ай бұрын
Thank you for teaching us
@abdulmajeeth3135
@abdulmajeeth3135 11 ай бұрын
Thanks👍🏻
@cucinacapresemonaco9932
@cucinacapresemonaco9932 Жыл бұрын
Hallo wean the system get tasted and the gas shot off but not the power what is that mean? thank you for your Time
@jitinyadav6507
@jitinyadav6507 Жыл бұрын
I want to know the refilling time period of fire suspension system
@agray007
@agray007 Жыл бұрын
what type licensing is required for this type of inspection?
@pressurewashingandhoodcleaning
@pressurewashingandhoodcleaning 9 ай бұрын
why do you have all those lights?
@ahmedalhourani4603
@ahmedalhourani4603 6 ай бұрын
how i can flush the system after discharge
@hemandersingh4502
@hemandersingh4502 Жыл бұрын
Hello sir Which gas cartridge is this and at what temprature the fuseable link breaks ??
@juliobojorquez8706
@juliobojorquez8706 Жыл бұрын
Nitrogen and temp is 450f
@marks7352
@marks7352 Жыл бұрын
Does it cost money for the system to be inspected?
@cindywine4660
@cindywine4660 Жыл бұрын
Yes
@johnn2557
@johnn2557 2 жыл бұрын
He also did not test the water flow connection for proper pressure and check the water valve in in the locked open position.
@davem287
@davem287 Жыл бұрын
He clearly wasn't going to show every detail it's a customer demo not a training video
@fF-jb4gs
@fF-jb4gs 10 ай бұрын
Looks like a training facility by the looks of the extremely clean appliances
@patienceiskey8181
@patienceiskey8181 11 ай бұрын
What size is this?
@fF-jb4gs
@fF-jb4gs 10 ай бұрын
3 gallon
@annmccormick
@annmccormick 7 ай бұрын
Judge Judy
@nazreatweldeyohannes3334
@nazreatweldeyohannes3334 10 ай бұрын
I need new
@mdbb7202
@mdbb7202 2 жыл бұрын
Umm I hope this ain't a training video. The pull station is too high up. It looks like you are using a small pair of channel locks not the right pliers. What kind of break rod is that? And put a test link in instead of cutting the actual detector. You didn't blow out the distribution line with air.
@davem287
@davem287 Жыл бұрын
It's clearly a customer demo, he's talking to the customer end. The pull station location is probably the customers choice which is fine, Authority having jurisdiction I.e. the owner can specify the location. Nothing wrong with not using a test link nor anything wrong using a small pipe grips for the scissor links. Typical snob engineer trying to shoot down another guys work, I've met plenty like you and let me tell you they are the worst offenders when in comes to compliance. So you know some regulations big deal !! These systems aren't rocket science !
@paullistokin9736
@paullistokin9736 9 ай бұрын
Customer's choice? Nowhere in NFPA 17A or IMC, IBC, ICC, or even in the Ansul (the manufacturer) manual will it allow for a location other than 48" from finished floor. Customer can choose where the pull station goes as far as kitchen location as long as the installer and/or AHJ will allow, but never alter in height.
@Carti2official
@Carti2official 9 ай бұрын
Customer does not get a choice in the height of the pull station. No more than 48 inches from the ground. NFPA code, Ansul specifications. Done hundreds of finals with AHJ, fire Marshals and Mechanical inspectors. Same code for fire alarm pull stations.
@pressurewashingandhoodcleaning
@pressurewashingandhoodcleaning Жыл бұрын
manual pull station is to high.
@davem287
@davem287 Жыл бұрын
Customers choice
@Carti2official
@Carti2official 9 ай бұрын
@@davem287customer doesn’t get a choice. No more than 48 inches from the ground is the code.
@sarwarkarim2921
@sarwarkarim2921 2 жыл бұрын
Great to see you sir i want to connect you so please can i have your email address I'm also fire fighting technician
@Carti2official
@Carti2official 9 ай бұрын
That system is well beyond the allowed flow points😂😂😂. You’ve said nothing about nozzle coverage or anything. That’s Ansuls overlapping coverage. Do Better
@iGotSoldAgain
@iGotSoldAgain 9 ай бұрын
well it's a piranha system. could easily be a 13 tank. each nozzle has 1 flow and could very easily have be enough flows on the cylinder
@iGotSoldAgain
@iGotSoldAgain 9 ай бұрын
also, all piranha systems are total flood
The Most Efficient and Safest Restaurant Exhaust Hood Degreaser
5:16
MFS Trade School
Рет қаралды 256 М.
How to win a argument
9:28
ajaxkmr
Рет қаралды 446 М.
Я обещал подарить ему самокат!
01:00
Vlad Samokatchik
Рет қаралды 10 МЛН
Joker can't swim!#joker #shorts
00:46
Untitled Joker
Рет қаралды 29 МЛН
Ansul Instructional Video for freddy
10:05
Michael Bushatz
Рет қаралды 12 М.
Kitchen Inspection
3:40
Silco Fire & Security
Рет қаралды 7 М.
Who Wants to be a Millionaire US: First Million Dollar Winner with John Carpenter
19:07
Motherland Darren's Sessions
Рет қаралды 3,7 МЛН
Kitchen Suppression Systems and Clogged Detection Lines
6:22
Commercial Fire
Рет қаралды 70 М.
Kitchen Exhaust Cleaning   Commercial Vent
3:01
Commercial Vent Cleaning
Рет қаралды 392 М.
The basics of a kitchen fire suppression system
5:59
Defense Fire Protection Inc.
Рет қаралды 2,5 М.
FireDETEC Fire Suppression System for Commercial Kitchens
4:12
Rotarex Firetec
Рет қаралды 43 М.
How to Clean a Kitchen Exhaust Hood | Start to Finish
9:13
Powerwash.com
Рет қаралды 65 М.
Aircraft Hangar Foam Fire Suppression Test - Prince George.wmv
4:27
AllpointsFP
Рет қаралды 13 МЛН
ANSUL R 102 R-102 Owner Operator Training to maintain a Restaurant Fire Suppression System
9:41
Fire Protection Products from Johnson Controls
Рет қаралды 140 М.
Я обещал подарить ему самокат!
01:00
Vlad Samokatchik
Рет қаралды 10 МЛН