Kohler 20kW RESD

  Рет қаралды 102,788

Elite Power & Energy Corporation

Elite Power & Energy Corporation

7 жыл бұрын

Basic Installation Tips and Procedures

Пікірлер: 104
@mikestock6461
@mikestock6461 5 жыл бұрын
I know Kolher takes a lot of pride in their dealer network and dealers that do quality installations like this. This is exceptional work! Thank you for sharing.
@asuarezjd
@asuarezjd 3 жыл бұрын
Extremely grateful for this video which is the only one that actually shows the wiring in detail. I bought a Kohler 20RESAL-200 and comes with an RXT-JFNC-0200ASE ATS, [200AMP Service Entrance (breaker)]. I paid for it a month ago but is still in back order. I pulled a city permit and now Fairlawn, Ohio, requires a disconnect outside for the generator as well. It has one in the actual unit but to make the inspector happy and because the unit can always be replaced, I installed a Square D 100 AMP safety switch. This is so the firemen can disconnect the generator since it will turn on once they pull the meter and they won't spray the house until the generator is disconnected of course. All is ready for the unit to be connected, so I was wondering how to connect the Belden and it was good to see the video. I bought the Belden according to the installation manual Kohler sent me in advance. And, I ran it separate in a 1/2 EMT. Yet, I have three questions: 1. Can I run the three 14AWG (blk, wht, grn for battery/accessories charge) in the same conduit as the four #4 copper wires for the generator? 2. Where is the battery line coming from? it looks like it goes to the side of the ATS. Is there a spare 120V fed from the utility Service entrance connectors somewhere? 3. My wiring is a non separated ground and neutral so its only bonded at the ATS...so I need it to be a floating ground at the Kohler generator. I know Kohler has to ship them bonded but I cannot find anywhere how to detach that "bonding". Thanks again for the video!
@GeezingInVA
@GeezingInVA 6 жыл бұрын
Great video. We're feeling fortunate you've been our Kohler 20RES installer and service provider for the past seven years.
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 5 жыл бұрын
GeezingInVA we are happy to be your service provider.
@nighthawk_predator1877
@nighthawk_predator1877 Жыл бұрын
I wish there was someone near where I live that would take as much consideration and care and detail in their installation process as you seem to. I want a kohler too but not sure who I can trust to do this work correctly and with hurricanes and our area in general in mind.
@darrickhock
@darrickhock 5 жыл бұрын
Looking for contractors to do work that will take the time to think about small details that make the install clean an thought out is hard to come by. This kind of install is a craft. One thing I try to teach my kids is weather you are flipping burgers or working for NASA. Do your job to the utmost. Take pride in what you do it is what put food on the table. You done a fine job.
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 5 жыл бұрын
Defender One in training new employees I ask every one of them the same question: “Do you know the difference between a good technician and a great technician?” They always say no. I then tell them it is about 5 minutes. That is the amount of time it takes to do what is considered “above and beyond” average work. It doesn’t take any more skill or training, it just takes time and taking it to do the right thing. Being a professional is always doing the right thing - even when no one is looking or knows where to look. I was taught by an old school master that had one saying “We are judged by one thing as tradesman, our craftsmanship, and when we are gone it cannot say anything so let the quality of the work tell the story.”
@mateonevis142
@mateonevis142 4 жыл бұрын
Great video! I'm happy to see how simple the installation is. Had there been a high-speed internet on this install, where would that data jack been plugged in to? And would that data be used with an app or another device within the home for monitoring purposes? Thanks.
@antech555
@antech555 4 жыл бұрын
I like the way you run power through the concrete pad. Does the 20resc have the same access hole to run power through the bottom?
@prowd5331
@prowd5331 4 жыл бұрын
Great Video! Where did you get the feed for the battery charger circuit, in the ATS or from the MDP?
@michaelsliwinski8044
@michaelsliwinski8044 6 жыл бұрын
Thanks. Nice overview.
@Deklectic
@Deklectic 2 жыл бұрын
Finally someone who has MY identical generator.. Everytime I look up stuff on generators they are all the plastic models which I know they serve the same purpose but I'm sure there are quite some differences.. Why are generator companies making them with plastic?? While at the same time charging the SAME amount or MORE as a more sturdy metal model. I would think it would be a national "standard" to make ALL full house generators out of metal to withstand harsh weather conditions through out the seasons but instead I keep seeing them made with plastic which to me is much weaker than metal maybe I'm just naive in this deparment and plastic is the way to go.. I just feel like for 5,500+ your not going to give me the same cheap plastic material they use to make walmart sandboxes for kids with so I specifically told my contractor I only want a metal if I'm going to pay over 6'000 for a generator because in reality it most likely cost them a few hundred dollars to produce then they over hype the price, with metal I feel like I actually get my moneys worth plus longevity. It just seems extremely cheap to me as a consumer.
@tukseychatham1740
@tukseychatham1740 4 жыл бұрын
Thanks, very helpful.
@DJaquithFL
@DJaquithFL 6 жыл бұрын
I wish you were in the Sarasota, FL area. Excellent install .. we're looking to replace our old 16 kW Generac with potentially this Kohler unit.
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
D Jaquith - Thank you. Let us know if we can of assistance.
@DJaquithFL
@DJaquithFL 6 жыл бұрын
Elite Power & Energy Corporation If you do work in Sarasota, Florida then you can .. we're in the market now.
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
D Jaquith - unfortunately we aren’t. Good luck with your installation. Make sure you: A) - NEVER buy from anyone that is not a dealer and/or certified to install KOHLER. You don’t want them learning on your home. B) - Ensure you have a CERTIFIED start-up performed to confirm the installation is up to KOHLER standards. C) - Try to get an installer that self performs all the work so there are no issues down the road as to whom did what wrong. Don’t buy anything from anyone that cannot perform service on what they install.
@DJaquithFL
@DJaquithFL 6 жыл бұрын
Elite Power & Energy Corporation Excellent tips. I'd 100% hire you and your company, very impressive work! Absolutely, I'll follow your advice and many thanks.
@stangbang100
@stangbang100 4 жыл бұрын
Did you have bad luck with the Generac? I'm torn between the Generac and Kohler.
@Thesimplehomeowner
@Thesimplehomeowner 5 жыл бұрын
Quality workmanship, I would hire you just on how you ran the wires in the generator. Not many contractors take that kind of pride in their work.
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 5 жыл бұрын
gibbyair1 appreciate the kind words. We try to provide the clients the best product for their money.
@Thesimplehomeowner
@Thesimplehomeowner 5 жыл бұрын
Elite Power & Energy Corporation I am looking to get a generator that size but currently have a 200gallon propane tank I think it is, would I have to go up to 500 gallon to make it work w/ proper pressure
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 5 жыл бұрын
gibbyair1 it’s not a problem with pressure as all tanks work on the same pressures. It is the amount of gas on hand for outages and the ability to continue to vaporize the LP, which is why larger tanks are better.
@Thesimplehomeowner
@Thesimplehomeowner 5 жыл бұрын
great information, thank you@@elitepowerenergycorporatio3254
@XX-166
@XX-166 4 жыл бұрын
1500 sq foot house with a finished basement in Illinois. What size would I need and how much is kohler vs generac. Heat/ac. Some lights fridge and internet and sump pump.
@markf4328
@markf4328 3 жыл бұрын
Nice Video. Is the battery charger circuit in the load conduit or did you run a separate conduit for the battery charger circuit? Do you still ship these or bigger kohler units?
@f143744
@f143744 4 жыл бұрын
Generac does not use “Line Voltage “ to control switching. Also, we can run low voltage and line voltage together with 600V Tray Cable. Check your 2017 NEC Code, completely legal.
@edbouhl3100
@edbouhl3100 3 жыл бұрын
Could you elaborate which NEC code sections you’re referring to for residential use? Thank you. ARTICLE 727 Instrumentation Tray Cable: Type ITC ..... 727.4 Uses Permitted. Type ITC cable shall be permitted to be used as follows in industrial establishments where the conditions of maintenance and supervision ensure that only qualified persons service the installation: (1) In cable trays. (2) In raceways. ....
@benherbst6822
@benherbst6822 2 жыл бұрын
All models of transfer switch coils use line voltage for switching. The twisted pair is not for control its for coms between tr/sw and rd2 cont. The logic board in tr/sw controls switching. The only code that applys to install of the twisted pair would be 110.3 b
@jamescash8051
@jamescash8051 3 жыл бұрын
Thanks for the informative video. I am curious why run the propane through copper? Wouldn't poly or csst be a more permanent solution? Not critiquing, just inquiring.
@movietime111
@movietime111 5 жыл бұрын
How long can a unit like this ring continuously? Thanks,
@mafosa8519
@mafosa8519 2 жыл бұрын
just curios.. why is the gen. main breaker so far away from the "exit point" on the alternator? also the starter on the back side of the gen.? just asking.. really good though! larry
@trav1374
@trav1374 2 жыл бұрын
Hello, could you tell me where you got or who makes that armored cable you used for the generator load
@frankg1963
@frankg1963 3 жыл бұрын
What size external LP gas regulator did you use ? I need one for LP and Natural Gas. Will they interchange ?
@franimal007
@franimal007 2 жыл бұрын
Does the unit display faults when not in use, or during excersising mode, or at worse during a time of need?
@jrannis8076
@jrannis8076 4 жыл бұрын
Its looks good until you brought us to the ATS. We wouldn't pass inspection in SE Florida. A hub would be required when entering the top of the AST, I would be interested in knowing how and where you tapped that battery charger circuit and would not have installed that open fuse. I have no idea why you ran that cable into the house like that, it wouldn't pass here.
@billwhittington8232
@billwhittington8232 3 жыл бұрын
How do you get front/side covers off 20RESD to access 1) battery; 2) oil drain plug/hose and 3) other areas? Also, where do I buy "On Cue"?
@edbouhl3100
@edbouhl3100 2 жыл бұрын
How do the RES models compare to the RMY models for residential use?
@Jere616
@Jere616 6 жыл бұрын
Great video. Impressive installation. Is there any way for the homeowner to see the status of the generator from inside the home by some device or meter?
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
Jere616 - The On Cue system connects the unit to you via the internet with an App or on your PC. Most people use the App.
@Jere616
@Jere616 6 жыл бұрын
Cool. Thanks!
@Frostytravels
@Frostytravels 6 жыл бұрын
very nice installation. Quite professional..where are you located at? I am in Florida and obviously i need a Generator...lol
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
Frosty 8415 we are located in Virginia. If you need assistance we would be happy to help you find the right sized generator for your home. We can sell and ship to you if interested.
@HonorableHarbinger
@HonorableHarbinger 5 жыл бұрын
You installed SER exposed outside.... Everything looked great up until there. Appreciate the info on Kohler though.
@JesusSaves194
@JesusSaves194 4 жыл бұрын
J Floyd Should be protected
@sniggity
@sniggity 6 жыл бұрын
I have a question, with a unit this size, what can be run on it? I have a gas furnace, three freezers, fridge, net, four or five tv's etc. you get the gist, standard house. Would something like this power that? Or is it for the basics like water pump for the well, furnace and s few lights and that's it? Great video, too ! Nice install.
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
sniggity - You would be fine. Might need a load control device or two depending on the large appliances but if done correctly this will fit your needs.
@ACommenterOnYouTube
@ACommenterOnYouTube 5 жыл бұрын
sniggity: There are 2 ways to determine how much power you are using.. 1 is to get a clamp meter and put it on each of the 120V primary legs... Then its some adding and calculating between the 120V and the 240V appliances... Its not easy at 1st but once you get the hang of it, you can determine how much power you are using in real time ... OR Buy this below.. It shows in real time how much power you are using, it re-freshes every 10 seconds ... I have it, its great, i know how much power each appliance is using .. The MOST i have EVER used was 17k watts ... www.amazon.com/Efergy-4-0-Wireless-Electricity-Monitor/dp/B001Q1G4WK/ref=sr_1_3?ie=UTF8&qid=1539535750&sr=8-3&keywords=efergy+elite+4.0+wireless+electricity+monitor
@NotAnotherSmith123
@NotAnotherSmith123 6 жыл бұрын
I have a 20RESA and it has had its issues. Looks like Kohler fixed a lot of the flaws. I went through 3 plastic housings in 3 years due to cracks. Now just discovered the upgrade to the battery charging circuit now that the unit is out of warranty. Nice install. Took Kohler too long fix the product in my opinion.
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
Michael Smith Give me your address and we will mail you the part (free of charge) if you will pay the shipping. It’s an easy fix but you should upgrade firmware too. Not sure where you are located so not sure about qualified service in your area. Worst case - you ship us the controller and we update it for you and ship it back. You would be exposed while this happens but we can help if you need it.
@NotAnotherSmith123
@NotAnotherSmith123 6 жыл бұрын
Elite Power & Energy Corporation thank you very much for the offer, the charger part just arrived in the mail today. I live in NewJersey and I’ve been on generator power since Friday. Had a dead (cooked) battery on Saturday. But your video solved my problem and that was great free advice. Recently a local shop I frequent started supporting Kohler generators I’ll talk to them once power is back about the firmware. I’m at 320 hours on the unit. Thanks again.
@russellmyers934
@russellmyers934 6 жыл бұрын
I have a Kohler 20RESC installed new in September 2016. What are the details on the upgraded battery charging circuit and firmware? Is this something I might need for my own generator or is this for older models?
@russellmyers934
@russellmyers934 6 жыл бұрын
It's charging the battery at 13.3v; never had an issue with a battery going bad. Current firmware RDC2 is 6.7; newest is 6.12.2. Install looks not too difficult.
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
Russell Myers it depends on when the unit was manufactured as it may have set on a shelf for 2 years before you got it. An easy way to check is to verify what the charging voltage is at while at the Ready position. If it is charging at 14.1VDC or more you need the Battery Charger Diode kit. If it is 13.3-13.7VDC you are good. You should be running the latest firmware and your service provider should upgrade when they provide your service.
@hpardo
@hpardo 5 жыл бұрын
Hi brother. I'm looking this install Thais quite different from my because the communication wires goes through the console main lines. And I having an error on ATX PCB board giving communication problems and the other error says low voltage ATX emergency. Well I'm in venezuela the Gen set only has 152.4 hours running. The Gen set shouting down for protection. And theres no support Kohler's here. And the other little problems seems that the Gen set has dc2 controller and looking in Internet need the sitetech software because can't connect in other way (oncue) to reset the errors. The Gen set running 152.2 hours only 5 minutes on sometime 30 min and lately only 3 minutes and enter the protection mode ant the ATX PCB board only blink a red led. I tried all. if you can helpme in any way please. Thanks bro. I called Kohler's and said my 20rescl never sale outside us or Canada by the model and the sellers no show up after sale. Thanks if you can helpme
@kurtishasselbring3166
@kurtishasselbring3166 6 жыл бұрын
Is the base on the 20kw RESD aluminum too? I've seen people complain about certain models because the base is steel and rusts..
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
Kurtis Hasselbring aluminum
@brickit26
@brickit26 6 жыл бұрын
Very nice install. How much for this unit including 200 amp single phase transfer switch? Also what are the dimensions of the unit or a link with the specs, Kohler doesn't show resd version of 20kw on there site. Thanks
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
brickit26 you can obtain the specs from our website but the price depends on the type of switch you select ad there are several types of 200Amp switches. Budget $5K for the equipment.
@brickit26
@brickit26 6 жыл бұрын
Elite Power & Energy Corporation Thanks, Also on average how much to install this type of gen and switch?
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
brickit26 our installation packages start at $11,299 plus permits, depending on the jurisdiction (they range from $50 to $1000) but most installs are in the $13-15K range, turnkey.
@brickit26
@brickit26 6 жыл бұрын
Elite Power & Energy Corporation Thanks
@exJacktar
@exJacktar 5 жыл бұрын
@@elitepowerenergycorporatio3254 Thank you as well. I am in Canada so the costs will be different here, but this gives me food for thought. Power outtages in winter and hurricane seasons are becoming more frequent.
@basketballjones6782
@basketballjones6782 11 ай бұрын
Must be Belden? LOL Nice dirt leg on that LPG feed too.
@ricardobooker1704
@ricardobooker1704 7 ай бұрын
Are you still monitoring this video? I have some questions.
@Jere616
@Jere616 6 жыл бұрын
One more question if I may. How loud is it? Decibel-wise at say 10 feet away for example?
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
Jere616 units ate measured at 23’ (7 meters) during testing. This unit is 69dB at that range.
@Jere616
@Jere616 6 жыл бұрын
Thank you.
@mark31383
@mark31383 5 жыл бұрын
Hello, I'm in the process of setting up a backup power system for my house. I loose power a lot because of snow storms. My advantage power outage is 5-8 days 4 or 5 times a winter. How many hours of reliable run time would you get out of a unit like this before you would need to re-build or replace it? Are there's units built to run 5-7 days at a time? Thanks
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 5 жыл бұрын
Woody83 - this unit will run for several thousand hours before needing replaced - if ever. Running 5-7 days is no problem as we have many that do that with outages we have here. The key to keeping them running properly is shutting them down to check the oil - and a good visual inspection - every 24 hours of continuous run time. Proper maintenance will keep your unit running for many, many years.
@mark31383
@mark31383 5 жыл бұрын
@@elitepowerenergycorporatio3254 Thanks!
@quachtinhho
@quachtinhho 2 жыл бұрын
Good like!!
@rolytech212
@rolytech212 4 жыл бұрын
On this exact unit, how do we set weekly starting to keep battery charged? Mine does not run weekly.
@SubStationSparky
@SubStationSparky 4 жыл бұрын
You really need a separate 120v circuit from your house electrical panel for constant charging. But it should be doing a weekly test or exercise. Consult the installation manual
@jordanonofer3886
@jordanonofer3886 Жыл бұрын
I'm think. There is a button in the switch. It might say test. I think you hold it for 3.secinds and it sets test time to whatever time and day it is when you do it . Not explaining very well but just watched someone do it the other day.
@kurtishasselbring3166
@kurtishasselbring3166 6 жыл бұрын
Can you still get this model? Seems that their website now only has the composite housing unless you step up into the bigger generators that most houses wouldn't need...
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
Kurtis Hasselbring you can only get this model from a dealer. Kohler does not advertise this model at all and you cannot buy it “just anywhere.” Check with your local dealer or we can sell and ship to you.
@kurtishasselbring3166
@kurtishasselbring3166 6 жыл бұрын
Ahhh ok - and this can be monitored with a smartphone as well?
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
Kurtis Hasselbring with On Cue, yes.
@kurtishasselbring3166
@kurtishasselbring3166 6 жыл бұрын
Thanks for your replies - one last question. When placing one of these on a property- what’s the maximum distance from the home that you can go before you have to worry about voltage drop? I may try & have mine placed further away from my house to be closer to the buried propane tank, but I’m not sure how far away I could go..
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
Kurtis Hasselbring rule of thumb is 100’ before upsizing wire size.
@jonathansabo4957
@jonathansabo4957 6 жыл бұрын
As long as your low voltage cables are rated at or above the maximum voltage there is NO CODE VIOLATION by installing the control wiring in the same conduit ! An awm rated cable is listed @ 600 volts. Kohler does recommend a separate conduit and manufacturers specs NEED to be followed !
@benherbst6822
@benherbst6822 2 жыл бұрын
110.3 b.
@abdulrehmanmian1476
@abdulrehmanmian1476 3 жыл бұрын
Why didn't the customer go for a diesel generator? Saves cost for the lpg tank
@ryannorthup7309
@ryannorthup7309 3 жыл бұрын
Why did you go through the effort of such a clean and neat installation (which I commend you on) But left that rusty meter socket? I find it hard to believe you couldn't have at least sold a new meter socket if not the whole service! Really seems to me a disservice to your customer to hook up a brand new back up generator to such crappy service.
@edwardluth7740
@edwardluth7740 2 жыл бұрын
I agree on installation. Sick of HVAC Trane and all that put down cheap pads then them damn voles and mice burrow and my Compressor heat pump sits slanted and I had a hell of a time carefully leveling it. Is Kohler better than Generac!? I hear it is and what about Cummins? Sooner or later I’ll find out which. So tired of fake ratings and ignorant people or over advertisements.
@wmc9722
@wmc9722 6 жыл бұрын
EPEC: I'm pleased to have found your smart video and, like 'Frosty', was wondering where you guys are (not sure if you have a link on the page, or in your playlist, etc). If you were close to me, ie., Eastern Massachusetts, making a plan for our installation would happen quickly. We just built a 4000sqft house that has a natural gas heating system, natural gas burners in the kitchen, electrical water-heating system. I'm thinking of doing at a minimum a Kohler 24RCL. kohler.jamgraphicsvps2.com/cmsAdmin/uploads/g4228.pdf I want to install a system that is substantially more that what we actually need as someday I'll need to move and this house will become a rental property and I want to know that the future renter will be in good stead. Thanks for recording and sharing this project. This assists a homeowner in finding a qualified installer.
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
Warren Currier we are located in Aldie, Virginia.
@CTKTMRIDER
@CTKTMRIDER 6 жыл бұрын
No load shedding devices on this install?
@elitepowerenergycorporatio3254
@elitepowerenergycorporatio3254 6 жыл бұрын
CTKTMRIDER no. No need as the loads did not dictate.
@CTKTMRIDER
@CTKTMRIDER 6 жыл бұрын
10-4
@ACommenterOnYouTube
@ACommenterOnYouTube 5 жыл бұрын
why do you want load shedding..??
@LeeH-Ranger83
@LeeH-Ranger83 2 жыл бұрын
RDT or RXT Automatic Transfer Switch (ATS).
@atiqhashmi7451
@atiqhashmi7451 Жыл бұрын
cna anyone please send me the kohler power system how to fix wiring please model no ch470ep model i want just wire daigram its very urgent
@robertthornton7553
@robertthornton7553 2 жыл бұрын
How you get 20 kw from a lawnmower engine , it will be warm very shortly
@mikeduwe
@mikeduwe Жыл бұрын
Its a 999cc engine
@MrGregcel09
@MrGregcel09 3 жыл бұрын
MY GENERAC DID NOT EVEN LAST A WEEK TILL IT FAILED ON ME !!!! BIGGEST PIECE OF JUNK YOU CAN BUY !!!! IF YOU BUY A GENERAC ,YOU WILL BE SORRY THAT YOU DID , TRUST ME !!!!!!!!!!
@electricety
@electricety 3 жыл бұрын
Wow he's wrong
Why Kohler with Geco Industries
9:35
GECO INDUSTRIES
Рет қаралды 39 М.
Cummins RS25 Generator Review
16:25
Travis Bruehl
Рет қаралды 157 М.
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Savage Vlogs
Рет қаралды 9 МЛН
Switching 11kV VCB Tamco
7:34
competence 33kv
Рет қаралды 2,5 МЛН
20kW Kohler Hunting Issues
4:52
Elite Power & Energy Corporation
Рет қаралды 22 М.
Kohler Generator Maintenance Must Service
15:24
The HVAC Hacker
Рет қаралды 85 М.
Whole-Home Generators: Peace of Mind or Financial Liability?
13:04
Electric Pro Academy
Рет қаралды 73 М.
Generac 22KW Blown Fuse
9:54
Dan
Рет қаралды 30 М.
Kohler Generator Battery Exploded Not Cranking
7:08
The HVAC Hacker
Рет қаралды 5 М.
Kohler 24RCL Generator Delivery and First Look
22:09
Christopher Masto
Рет қаралды 11 М.