Ladder Logic Programming Basics - OTL & OTU | Output Latch / Unlatch Instruction in RSLogix 5000

  Рет қаралды 19,446

SolisPLC

SolisPLC

6 жыл бұрын

Ladder Logic Programming Basics - OTL & OTU | Output Latch / Unlatch Instruction in RSLogix 5000
Visit SolisPLC.com for more Tutorials, Information & connect with the Community
The OTL, also known as the Output Latch, instruction will force a single bit of logic into a high state if all the conditions leading to it are true. It’s a basic instruction which is powerful but can cause programmers a lot of grief if used improperly or too frequently. This instruction is found on the right side of a ladder logic rung and will switch a bit to a HIGH state once it executes. Unlike the OTE Instruction, the OTL will never turn the bit LOW. In order to make that happen, you can leverage other instructions which accomplish exactly that. That being said, the most common pairing with an OTL is an OTU (Output Unlatch).
solisplc.com/plc-programming-...
solisplc.com/plc-programming-...
Find us on social media:
Web: solisplc.com/
Forum: solisplc.com/forum/
LinkedIn: / solisplc
Facebook: / solisplc
Instagram: / solisplc
Twitter: / solis_plc
Relevant Search Terms
ladder logic programming, ladder logic basics, ladder logic examples, ladder logic plc, ladder logic plc programming, ladder logic plc programing examples, ladder logic otl, ladder logic otu, output latch, output unlatch

Пікірлер: 13
@hutotgab
@hutotgab 2 жыл бұрын
I just started to learn plc programming, and found you. I feel like with your videos I really can understand how it’s works. Appreciate your work!
4 жыл бұрын
Thank you. This is a great explanation.
@electrichorror6642
@electrichorror6642 4 жыл бұрын
lookin slick there Vlad
@electronicsdost127
@electronicsdost127 3 жыл бұрын
Really great information 👌👌
@SolisPLC
@SolisPLC 3 жыл бұрын
Glad you found it helpful!
@bhanupraneeth8663
@bhanupraneeth8663 5 жыл бұрын
Great job man
@SolisPLC
@SolisPLC 5 жыл бұрын
Thank you for the kind comment. Is there anything in particular you'd like to see in the future videos?
@bhanupraneeth8663
@bhanupraneeth8663 5 жыл бұрын
@@SolisPLC plc based traffic controller, automatic star -delta starter, forward and reverse of induction motor . Video on the above topics would be great .
@anoop22march
@anoop22march 5 жыл бұрын
Sir how we can check which input or output is not used, like cross reference
@nateballew2369
@nateballew2369 4 жыл бұрын
Hi Vlad, when you energize the latch "coil" why is the unlatch green as well?
4 жыл бұрын
Hi, because this instruction addressing the same bit. If you start one, others will follow. :)
@afzalbyabani1373
@afzalbyabani1373 5 жыл бұрын
Interesting, I tested a bit different i.e., I used NC contact instead of NO with OTU and the program acted differently. When I was changing the NO with OTL to high the OTL wouldn't turn ON. I had to use NO contacts only with both OTL and OTC.
@vincea2732
@vincea2732 5 жыл бұрын
If you use a NC contact with the OTU it wouldn't allow you to latch with a NO since it's constantly unlatching, and vise versa.
Survival skills: A great idea with duct tape #survival #lifehacks #camping
00:27
Looks realistic #tiktok
00:22
Анастасия Тарасова
Рет қаралды 103 МЛН
Became invisible for one day!  #funny #wednesday #memes
00:25
Watch Me
Рет қаралды 59 МЛН
8 - RSLogix/Studio5000 Manual Pt1 - Latch & Unlatch
36:55
plcprofessor
Рет қаралды 1,5 М.
PLC Latch & Unlatch, how and when to use it.
8:27
Professor Murray
Рет қаралды 2,2 М.