This video shows the lapping zone and lapping length in column. Overlapping of reinforcement in Rcc structures is required due to the limit of the steel bar length, so how much should be the overlapping length be provided so that steel have the good bond, for that we choose lapping length which should be according to the standard codes, and we should lap our column reinforcement where there is no critical section. For more details please watch full video.
Our channel brings civil engineering videos for students of Diploma, B-tech, M-tech, Bachelors and Masters.
Subscribe our channel for more civil engineering videos.
#Lappin #zone #Column

Пікірлер: 38
@user-cy7lc2fn7i
@user-cy7lc2fn7i Жыл бұрын
Wowowowo
@paulkabuluku5276
@paulkabuluku5276 2 жыл бұрын
Très bien j'ai compris avec les images tout traduisant directement merci c'est très sympa
@Mdwalidkhan7872
@Mdwalidkhan7872 7 ай бұрын
❤❤❤❤❤
@rajinderrausa6298
@rajinderrausa6298 3 жыл бұрын
Really very simple and informative video
@civilengineering94
@civilengineering94 3 жыл бұрын
Glad you liked it
@vigneshpandiyan8231
@vigneshpandiyan8231 4 жыл бұрын
Well explained thanks...
@junavered7804
@junavered7804 Жыл бұрын
thank you sir for this informative video♥️
@civilengineering94
@civilengineering94 Жыл бұрын
So nice of you
@gnidnoeled786
@gnidnoeled786 Жыл бұрын
@ 5:57, you did show us the stress diagram. Is that the moment on the column?
@phyohtetkoko929
@phyohtetkoko929 2 жыл бұрын
Thanks For Teaching Sir
@civilengineering94
@civilengineering94 2 жыл бұрын
It's my pleasure
@premsagarjagu8683
@premsagarjagu8683 Жыл бұрын
Awesome. SATISFIED BRO
@civilengineering94
@civilengineering94 Жыл бұрын
Glad you liked it
@akranjan4526
@akranjan4526 2 жыл бұрын
How the zone of stress overlapping affecting the capacity/reducing the efficiency?
@mgwunna3187
@mgwunna3187 5 жыл бұрын
very well explained........
@civilengineering94
@civilengineering94 5 жыл бұрын
Thanks alot
@sanjeewaweerakoon9716
@sanjeewaweerakoon9716 3 жыл бұрын
Can you lap steel bars at the footing of a column of a four storied building? Thanks
@neelamprajapati7672
@neelamprajapati7672 5 жыл бұрын
Very well explained.. please give idea about criteria of two way slab
@civilengineering94
@civilengineering94 5 жыл бұрын
I have uploaded video on that topic, you can watch this video. kzfaq.info/get/bejne/n-CeicmE1N7YkoE.html
@enchalewayenew9016
@enchalewayenew9016 4 жыл бұрын
I don’t understand why you said tension zone instead of compression zone for columns.
@MasterCivilEngineering
@MasterCivilEngineering 3 жыл бұрын
See here dear to know
@moosaalmoamen4770
@moosaalmoamen4770 2 жыл бұрын
what in case of seismic loads ?
@oms6335
@oms6335 3 жыл бұрын
Sariya me joggle nhi diya h lapping me Koi problem toh nhi hogi age pls btaiye sir
@AR-tl1cf
@AR-tl1cf 5 жыл бұрын
Thanks brother.
@MasterCivilEngineering
@MasterCivilEngineering 3 жыл бұрын
Good see here more
@minhalkhan4328
@minhalkhan4328 4 жыл бұрын
i want to learn about structural design.i am not an engineer. but doing construction...form where i can learn about it..I am watching videos from youtube.but i need someone who i can communicate. thanks.
@ershahnawaz220
@ershahnawaz220 4 жыл бұрын
You should study rrc book. You can find RCC lectures on KZfaq. In RCC you will know how to design different structural components. And for construction process study concrete technology.
@MasterCivilEngineering
@MasterCivilEngineering 3 жыл бұрын
See here more
@selvasiyan
@selvasiyan 5 жыл бұрын
column 48d formula (24d-48d)
@selvasiyan
@selvasiyan 5 жыл бұрын
d means dia of bar ex: 48d d=8mm dia bar use 48×8=384 this right or wrong explain pls reply
@RevealKaro
@RevealKaro 4 жыл бұрын
RIGHT BUT 48d IS NOT A CONSTANT VALUE . DEPENDING UPON THE GRADE OF STEEL AND GRADE OF CONCRETE THE LAPPING LENGTH GETS VARIES. KINDLY REFER IS 456 - 2000 ...CLAUSE 26.2.1
@sajjadalikhan9351
@sajjadalikhan9351 3 жыл бұрын
What is 48??
@AmitKumar-ih2hh
@AmitKumar-ih2hh 4 жыл бұрын
Design for colum video me 48D but in in lapping length 60D.why?
@MasterCivilEngineering
@MasterCivilEngineering 3 жыл бұрын
Find here
@sahilbanyal1232
@sahilbanyal1232 4 жыл бұрын
Sir kyi videos me L/4 ki jagah L/6 diya h..which one is ryt?
@MasterCivilEngineering
@MasterCivilEngineering 3 жыл бұрын
Good see here more
@mgwunna3187
@mgwunna3187 5 жыл бұрын
*********** Five Star
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 12 МЛН
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 38 МЛН
Lapping Length in Beams || Example solved
8:01
Civil Engineering
Рет қаралды 1,2 М.
The actual reason for using stirrups explained
9:01
The Engineering Hub
Рет қаралды 777 М.
Basic Rules for Lapping length in Column - Lap length in RCC Column
13:34
Understanding Buckling
14:49
The Efficient Engineer
Рет қаралды 832 М.
Difference between Short Column and Long Column
6:11
Civil Engineering
Рет қаралды 1 М.
What is Lap Length?
5:27
Engineering Motive
Рет қаралды 101 М.