Lesson 7 - Part 2: Power Distribution for Data Centers and UPS

  Рет қаралды 20,732

Engineering and Donuts

Engineering and Donuts

Күн бұрын

Пікірлер: 20
@user-fn9cs4dv8r
@user-fn9cs4dv8r 7 күн бұрын
Great info. UPS already has build in AC to DC converter, rectifier. That is how UPS is able to charge DC batteries. UPS also has a build in DC to AC converter, inverter. Thats is how UPS is feeding AC loads when utility power is lost.
@boostincrohns
@boostincrohns 18 күн бұрын
Looking into a hob for a data center tech. This vid helped out a lot.
@NgirgisFayez
@NgirgisFayez 2 ай бұрын
Thanks for your very useful information about Power Distribution for Data Centres and UPS
@prashantkrishna2743
@prashantkrishna2743 Жыл бұрын
wonderful, I am executing a data center and I found this video as easy, authentic and effective.
@DesignCrafter
@DesignCrafter Жыл бұрын
2:55 to 4:26 needs correction. An Automatic Transfer Switch (ATS) selects between 2 or more power sources (example, utility power and generator). An ATS does not convert AC to DC. Based on your example, the UPS will receive 480V AC, convert it internally to DC to charge the battery, convert back to 480V AC....
@engineeringanddonuts3917
@engineeringanddonuts3917 4 ай бұрын
This video is really designed for Data Center interviews. However, you make some good points. So I will review your comments and update the video.
@abdulhayat645
@abdulhayat645 Жыл бұрын
every data center has two main power sources the pirmary one is Utility and secondry one is generator, so power comes from the main utility to the transformer then to MCb or main circut braker, then to MSB or main switch board then goes to main Utiltiy circut- then to ATS and from ATS it goes to rectifier this where the power change from AC to dc and then to invertor to change from dc to ac and then it goes to PDU and from there it goes via bus lines to the client computer or server racks ..
@jgould30
@jgould30 Жыл бұрын
Why would the generator not be wired for fail over of the mains primary? That doesn't make sense to me to have the secondary power just be a generator. I could see if secondary was from a utilities provider and you had your generator on that circuit in case your secondary also went down maybe
@GM2181
@GM2181 4 ай бұрын
The PDU in the rack is supply by a A&B Power Panel, each power panel has it’s own UPS back up,and all is backed up by your generator,most buildings have 2 generators
@davidmosaku
@davidmosaku Ай бұрын
⁠@@jgould30 It does in reality. The mains output and the Generator power ouput connects to the Automatic Transfer Switch (ATS) or sometimes Auto Mains Failover (AMF) system. It’s the ATS that does the switching between Mains and Gen and viceversa. What you will typically have is The ATS is fed by output of: 1. Interconnections of Mains Feeder + RMU + Transformer + LV switchgear 2. Diesel Generator (s)
@Ahmedzakaria-dn8hh
@Ahmedzakaria-dn8hh 2 ай бұрын
Many thanks for video
@erikskywalker5331
@erikskywalker5331 Жыл бұрын
Can you do a video on specific SLD symbols and diagrams?
@DMV_L3GO
@DMV_L3GO 2 жыл бұрын
Love it
@BigBear21740
@BigBear21740 7 ай бұрын
Close... But not quite. One line doesn't look like that at all, actually, but its a useful explanation for lay people. I build data centers.
@kylelee639
@kylelee639 5 ай бұрын
True. It’s kind of close
@Matthew_O_Scale_Trains
@Matthew_O_Scale_Trains 3 жыл бұрын
Yes there is a flipping the bird emoji
@EnkSpot
@EnkSpot 5 ай бұрын
remote power panel, does anyone know what that is? please it's really important
@kylelee639
@kylelee639 5 ай бұрын
RPP are downstream from the ups. They step down from 480 to 208 or less. Feeding customer loads. That’ll be what the customer 20,30 amp 208v circuits are fed from
@GM2181
@GM2181 4 ай бұрын
How about a inverter and rectifier
@engineeringanddonuts3917
@engineeringanddonuts3917 4 ай бұрын
I already did a video for a full-bridge rectifier. And, the inverter is simply a DC to AC converter with a pulsing DC signal generator. The full derivation will require an extensive knowledge of integrated circuits. Does this answer your question?
Fundamentals of Data Center Power | Fundamentals of Power
29:24
GogoTraining - PeopleCert Accredited (ATO)
Рет қаралды 31 М.
What is a UPS and how does it work?
12:33
Eaton
Рет қаралды 25 М.
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 1,4 МЛН
女孩妒忌小丑女? #小丑#shorts
00:34
好人小丑
Рет қаралды 69 МЛН
Data Center HVAC Systems
20:14
MEP Academy
Рет қаралды 114 М.
Lesson 7 - Part 1: Utility Power and Summary
9:43
Engineering and Donuts
Рет қаралды 559
A DAY in the LIFE of the DATA CENTRE | GENERATOR TESTING with ASH!
12:52
Custodian Data Centres
Рет қаралды 251 М.
Data Centres - The Electrical Power System
55:05
EngineersIreland
Рет қаралды 39 М.
Data Center Power Chain - Animation
6:28
TechTrainerNJ
Рет қаралды 65 М.
How to Perform a UPS Transfer in a Critical Data Center
3:07
Sarah Rocap
Рет қаралды 209 М.
Data Center Fire Protection Designs with Lee Kaiser
1:00:49
ORR Protection
Рет қаралды 1,7 М.
Common Data Center Terms - Data Center Fundamentals
31:57
datacenterHawk
Рет қаралды 33 М.
A DAY in the LIFE of the DATA CENTRE | FULL CUSTOMER "RACK & STACK" with ASH & JAMES!
12:28