PLC Program for Thermocouple

  Рет қаралды 14,371

PLC Nerd

PLC Nerd

Жыл бұрын

Thermocouple is a temperature sensing device that is widely used in industries. Its working principle is Seebeck effect and it generates millivolts in response to change in temperature.
It is wired to a temperature controller that converts the millivolts to 4 to 20 mA DC that is supported by the analog input channel of any PLC i.e the Programmable logic controller.
The 4 to 20 mA value is sample by the AI channel of the PLC program in Hexadecimal format. That Hex value need to be converted to meaningful value so that we can further manipulate for our own requirement.
For this purpose, PLC program / Logic must be made for the analog sensor i.e Thermocouple in this case.
All PLCs have the same procedure while i will be using Siemens S7-300 PLC in my Step 7 project. In PLC program, the built in functioin SCALE FC 105 would be utilized for scaling of the Thermocouple sensor.
#plcprogramming #thermocouple #s7

Пікірлер: 11
@scottskeen2248
@scottskeen2248 4 ай бұрын
Thank you for the detailed walk through! I've been programming with a 318-2 DP CPU and trying to read the manual to program. This was much more helpful.
@Brian_Banda.
@Brian_Banda. Жыл бұрын
Thank you for the video
@amansrivastava9403
@amansrivastava9403 Жыл бұрын
Nice 👍
@worldinstrumentationengineer
@worldinstrumentationengineer 7 ай бұрын
Very good
@clementjr6700
@clementjr6700 Жыл бұрын
Great Video I have encountered a problem in my practice work. After following your steps to create the data block, when I go to the “out” section on the scale symbol and type DB1 it reads “element not found
@katthine5339
@katthine5339 Жыл бұрын
Nice. Please make more structured text videos.
@braincrackz
@braincrackz Жыл бұрын
Im your new follower now. I like the way you shared your knowledge.keep it up. God bless you
@PLCNerd
@PLCNerd Жыл бұрын
Thanks Dear
@benveron
@benveron 9 ай бұрын
Where can I get plc emulator
@mahiracar6364
@mahiracar6364 9 ай бұрын
why video is very low resolution .I could not read what you write
@PLCNerd
@PLCNerd 9 ай бұрын
video is not low resolution buddy. It is in HD. Just change the resolution.
How to Wire a Thermocouple to a PLC
6:30
RealPars
Рет қаралды 69 М.
Despicable Me Fart Blaster
00:51
_vector_
Рет қаралды 23 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:26
CRAZY GREAPA
Рет қаралды 6 МЛН
Now THIS is entertainment! 🤣
00:59
America's Got Talent
Рет қаралды 38 МЛН
Самый Молодой Актёр Без Оскара 😂
00:13
Глеб Рандалайнен
Рет қаралды 7 МЛН
TIA Portal: Analog Processing / NORM_X and SCALE_X
25:29
Hegamurl
Рет қаралды 162 М.
PLC S7-300 Analog input module connect with Pt-100, RTD and TC(Thermocouple)
12:51
General Technology Knowledge
Рет қаралды 10 М.
How to Upload Siemens S7300 PLC Back up using Simatic Manager and MPI Cable ?
9:25
PLC Programming Tutorials Tips and Tricks
Рет қаралды 114 М.
Despicable Me Fart Blaster
00:51
_vector_
Рет қаралды 23 МЛН