Powering My Home With A Wen 3800 Inverter Generator

  Рет қаралды 13,839

Braburgh Farm

Braburgh Farm

Жыл бұрын

Using the WEN 3800 Inverter Generator to power my home. Needed equipment found at Amazon below.
Interlock Kit at Amazon
www.amazon.com/gp/product/B08...
Generator Inlet Box at Amazon
www.amazon.com/Latest-Generat...
30amp to 50amp adaptor at Amazon
www.amazon.com/BrightHome-Fem...

Пікірлер: 38
@spacecoastz4026
@spacecoastz4026 10 ай бұрын
What you are not explaining, which honestly is one of the most important points, is that you are taking a 120v generator output, and splitting that feed, which is feeding both legs of your panel 120v single phase. In turn, all 120v house circuits will then work...but also none of the 240v would work...which is fine in most cases. I would suggest a few changes in your start-up process. Turn off all 240v breakers, turn off all refrigerators and electronics breakers, and keep the generator breaker off until the generator is up and running. Then turn on the generator breaker and then the refrigerator breakers. Keep all 240v breakers off until the generator is removed and normal power restored. Don't crank up the generator with live circuits that will be under load.
@GH-wt7ww
@GH-wt7ww Жыл бұрын
Just received my WEN 3800 inverter generator. I'm looking at fuel conversion kits for natural gas for a endless fuel source. Natural gas has never let me down during outages. You are doing exactly what I've been doing only power necessities. Clean and simple install nice work.
@solden49
@solden49 Жыл бұрын
This is an absolutely awesome video. You have given me a great idea. I have two of the wen 2250s with the parallel kit. This could be a good setup 👌
@jemf
@jemf Жыл бұрын
Hi,I’m not an expert but I think you need to first start the generator, let it warm and stabilize and only after that go to your panel and start loading it one circuit at a time. I have a smaller generator but it can handle all my essentials
@pinkiepie1656
@pinkiepie1656 Жыл бұрын
Correct. It should be started and warmed up a few minutes before flipping the generator breaker.
@weirdowolfstudio5409
@weirdowolfstudio5409 2 ай бұрын
@@pinkiepie1656it’s loud
@ghostofautumnwood6379
@ghostofautumnwood6379 Жыл бұрын
Hi. Great video. Can you share a link to the longer power cord you used?
@reynaldotorres4349
@reynaldotorres4349 11 ай бұрын
nice... question, how is that dog bone inside, it has a jumper in both hots?
@MrTmone2169
@MrTmone2169 Жыл бұрын
For an average house need a 5000w generator to power the whole house. I have two 5000w, one for the house and one for my workshop.
@kenmatthews6476
@kenmatthews6476 Жыл бұрын
Great video. FYI…the new WEN 3800 now comes with remote start/shut off. I sold my inverter like yours and miss it but will be buying the new version on the next sale.
@braburghfarm493
@braburghfarm493 Жыл бұрын
Thanks for the info!
@Confusedsole86
@Confusedsole86 Жыл бұрын
I've been looking for this. I can't find one with remote start and shut off.
@8894larry
@8894larry Жыл бұрын
You need to tell your viewers that that generator only puts out 120VAC! You have a 50/2 pole breaker but you can only put one leg from the generator into it. This means only one phase of your panel is energized! All the breakers/ loads you want on need to be on that phase. Start generator, shed loads, turn off main & 50/2 pole on & turn on breakers. Good luck!
@LocozillaYT
@LocozillaYT Жыл бұрын
I mean he made it pretty clear he wasnt/isn't a Electrician and also said to make sure to consult a Electrician if interested in doing it
@8894larry
@8894larry Жыл бұрын
@@LocozillaYT Oh, well that makes his video very educational!
@mikek8229
@mikek8229 Жыл бұрын
The 30 amp to 50 amp adapter he is using will energize both legs of his panel so he can use any 120 breaker. I know because I do this myself.
@xbleriot
@xbleriot Жыл бұрын
Not clear how you can power a main panel that requires 240V with a generator that only has a 120V output.....
@joshlasceski
@joshlasceski Жыл бұрын
@@xbleriot He is only powering 120V devices with this method.
@thejournalist384
@thejournalist384 8 ай бұрын
How much gas is needed typically for a full load ?
@600tnbobp9
@600tnbobp9 Жыл бұрын
I have purchased a slightly larger wen generator the 4500 W generator. These smaller generators aren’t like normal generators. They only put out 120 V. The much larger and noisier gasoline powered generators usually put out 240 V and 120 V. So my question is I see that you can power both sides of your electrical panel. I was wondering how the electrician wired your generator in to do that? I have my house set up With a larger 240 V 9400 W generator. It’ll power the whole house no problem, everything all at the same time but boy is it noisy. I also would like to hook up my house the same way you did yours and just cut off the items I don’t need , and have it a lot quieter. So if you could reply back and give me some idea how you could split off 120 V generator to power both sides of your electrical panel I would greatly appreciate it. Thanks Bob Phelan.
@spacecoastz4026
@spacecoastz4026 10 ай бұрын
It's very simple. You wire the inlet power box as normal for 240V. You purchase a short converter cord (as shown in this video) that takes the generator 120v output and splits it into two separate 120v feeds. If you won't be needing any 240v circuits this is actually more efficient that running 240v and only using 120v circuits. The reason its more efficient is that you are only having to manage total load, rather than two individual loads (per leg). Hope that makes sense.
@issameQ
@issameQ 4 ай бұрын
The panel is 240 v and the generator is 120v. How did that workout?
@thomabb
@thomabb 2 ай бұрын
I'm sure it didn't work out well. The two legs powered by the generator are in phase, so there will be no voltage across them. None of the electrical that requires 220v would work. A 30 amp RV outlet is only 110v single phase. To do this properly, he needs a generator with a 30 amp 220v outlet and cords that are not for RVs.
@wolfmanjack123
@wolfmanjack123 Жыл бұрын
So what were you able to actually run with this generator? Most of your major circuits were turned off.
@braburghfarm493
@braburghfarm493 Жыл бұрын
During our last outage I was able to run the circuits for both kitchen and garage fridges, septic pumps, all lights interior and exterior circuits, multiple TV's, and use of gas furnace. The one thing I didn't try, that I would like to experiment more with, is the electric hot water heater we've got. But, this is only a 30 amp Gen circuit, so wouldn't attempt with the rest of that load. Handled the rest without problems, and ran it in eco for a few days.
@wolfmanjack123
@wolfmanjack123 Жыл бұрын
@@braburghfarm493 Thanks! Sounds like the perfect little generator that will handle your basic needs for an average power outage. Great video!
@alvincarterm4
@alvincarterm4 8 ай бұрын
@@braburghfarm493​​⁠can you please answer my question. Ty
@thomabb
@thomabb 2 ай бұрын
@@braburghfarm493Don't run anything on a double pole breaker with that setup.
@jerry73j
@jerry73j Жыл бұрын
Wen does have one with remote start 4500
@braburghfarm493
@braburghfarm493 Жыл бұрын
That's what I've heard. Updated model has a few more features that I would love to have.
@alvincarterm4
@alvincarterm4 8 ай бұрын
Any reason you didn’t just buy a 30 AMP intel box instead of the 50 AMP box? Wouldn’t that eliminate the adapter? Getting ready to do this and just wanted to know the reason. Could it be that you wanted the option to upgrade to a generator that requires 50 AMP? Also, is the circuit breaker you are using 30AMP or 50AMP?
@dieseldawg7132
@dieseldawg7132 Ай бұрын
Smart thing to do is obviously go bigger on the inlet you do this incase you need to run a 10000 plus generator to run the hvac system …. A 30 amp wouldn’t be able to start the a/c it’s common sense
@chriseast030691
@chriseast030691 8 ай бұрын
You should never "Hot" start a generator. By that i mean start it with anything plugged in. Fail.
@dellwam7890
@dellwam7890 7 ай бұрын
It’s way lowder than the Champion and predator inverter generators…
@vontrap6942
@vontrap6942 8 ай бұрын
The big problem is this person talks soooo slowly it could be condensed to 3 seconds!!! Ffs
@issameQ
@issameQ 4 ай бұрын
Wana control how he talks? 😂
Powering my house with a 4500 watt 120v generator.
11:50
Big Green Shop
Рет қаралды 26 М.
Just try to use a cool gadget 😍
00:33
123 GO! SHORTS
Рет қаралды 85 МЛН
The day of the sea 🌊 🤣❤️ #demariki
00:22
Demariki
Рет қаралды 94 МЛН
I wish I could change THIS fast! 🤣
00:33
America's Got Talent
Рет қаралды 89 МЛН
Я нашел кто меня пранкует!
00:51
Аришнев
Рет қаралды 1,5 МЛН
The Good, the Bad, and what I've Learned so far with this WEN generator.
4:25
Monkey Woodworks and More
Рет қаралды 33 М.
GENKINS 3800. LOAD TEST ..WOW !!!!
7:44
KD'S INPUT
Рет қаралды 2,9 М.
Unboxing a $350 3600w Wen generator 56360i!! We run this unit thru the paces
8:08
Cogswell Racing - Home of the Blue Collar Bullet
Рет қаралды 3,6 М.
Best budget inverter generator of 2024?!
17:46
Tony Goodman
Рет қаралды 21 М.
Wen DF452iX Dual Fuel Inverter Generator Unboxing and Setup
9:43
TheManCaveVideo
Рет қаралды 12 М.
Best $10 Dollars You Will Spend On Your Generator
24:22
Katy Hill Farmer
Рет қаралды 19 М.
Why smaller generators are better for power outages.
12:55
Mechanical Mind
Рет қаралды 38 М.
WEN 3800 Inverter generator Review  Best generator??? WEN 56380i
8:24
JOHNNY'S WEEKENDS
Рет қаралды 49 М.
I CAN’T BELIEVE I LOST 😱
0:46
Topper Guild
Рет қаралды 70 МЛН
Застрявшее Кольцо 🤯
0:26
MovieLuvsky
Рет қаралды 4,5 МЛН
Турист раскрыл тайну нарисованной Италии
0:15
Короче, новости
Рет қаралды 1,5 МЛН
Jesus vs devil #jesus #devil
0:26
jesus my love
Рет қаралды 19 МЛН
OMG 😂😂😂#funny #rimiufun
0:16
Ri Miu Family
Рет қаралды 2,1 МЛН