Pump Head: Simple Explanation

  Рет қаралды 291,345

R.C. Worst & Co., Inc.

R.C. Worst & Co., Inc.

Күн бұрын

A.Y. McDonald Pump Basics PDF: www.rcworst.com/Shared/conten...
Other Friction Loss Calculators: bit.ly/32v9RoB
Chris take you through a basic explanation of what pump head is and how to calculate it. Topics covered include Total Dynamic Head, lift, loss, flow, pressure, friction loss (head loss), and converting PSI to feet. This is the first video in our new series on buying a pump and the factors involved.
If you need more information or assistance with products, call 855.329.4519 or email Customer.Service@RCWorst.com to speak with an industry expert. Thanks for watching!
Add us to your professional network: www.linkedin.com/company-beta...
Follow us on Twitter: / rcworst
Like us on Facebook: / rcworst
For more industry videos visit our KZfaq Channel: / @rcworstwater
Check out our website: www.rcworst.com/
We are a distributor of pumps, packaged pumping systems, on-site wastewater treatment equipment, on-site wastewater treatment systems, and custom electrical control panels for water and wastewater applications, water well supplies, drilling supplies, and water treatment equipment

Пікірлер: 61
@RCworstwater
@RCworstwater 6 жыл бұрын
Thanks for watching! If you have ANY questions or concerns about your water/wastewater system you can leave a comment, call our experts at 855.329.4519 or you can live chat with them on our website: RCWorst.com
@ersadali998
@ersadali998 5 жыл бұрын
Sir I have a question,plz reply me.. What is the reason of suction line pipe size is bigger than the delivery line pipe??
@EmranHashmi-1316
@EmranHashmi-1316 3 жыл бұрын
How to calculate flow rate if head and pressure given
@thiho5318
@thiho5318 5 жыл бұрын
very clear and simple explanation, thank !
@RCworstwater
@RCworstwater 5 жыл бұрын
Thanks for watching!
@cremaster0
@cremaster0 4 жыл бұрын
This was awesome!!
@TheFouffy
@TheFouffy 8 ай бұрын
Thanks so much for the clear explanation. It was a big help
@RCworstwater
@RCworstwater 8 ай бұрын
Glad it helped!
@mahavirgill3787
@mahavirgill3787 6 жыл бұрын
Thanks for your informative video. To calculate elevation, would the lower point be where the pump is set or where there is the static water line ? Thanks
@RCworstwater
@RCworstwater 6 жыл бұрын
Mahavir: That is a great question. You want to measure from the pumping level. The pumping level is the lowest water level reached during pumping operation. (Static level minus drawdown)
@philstat100
@philstat100 5 жыл бұрын
OK! Lets see if I understand this correctly. If my pump has a 50 ft lift and the water is only 5ft down below ground and my intake hose/pipe is 5 ft below the water level. I would still be able to pump the water 40 ft ft up above the ground level. Please crrect me if wrong. If I do not need to lift the water up the 40 ft, and instead I have to move it for a short distance , Would this affect my psi and flow rate?..If I had to move the water over a long distance then I would have to use the chart for friction loss. Thank You for the great video and information. Just trying to learn and apply it to practical use. Again Thank You. @@RCworstwater
@thth5549
@thth5549 4 жыл бұрын
Hi there can make video for how to choose booster and pipe line and calculate friction loss , when i want transit water from main tank in desert to the city, if elevation is 270 meter and distance is 69 kilometres and i want put water 550 gallon per minute UK gallon. In my city tank.
@Lee-xw5cf
@Lee-xw5cf 2 жыл бұрын
Does the discharge pressure of the pump equal to the total dynamic head (TDH) required by the system ?
@DanSanniti
@DanSanniti 10 ай бұрын
What about if you have loop. Say you have a 5ft of vertical lift, a 10 foot horizontal run into an open tub and then you also have a 5 foot vertical drop and a 10 foot horizontal run back to the start? Does the 5 foot drop negate the 5 foot lift entirely? Partially? Not at all? Does it somehow ADD to the total head?
@winston8022
@winston8022 2 жыл бұрын
My problem is we have a submersible pump 5HP and the tank is about 150 mtrs up sloping(head). What best size of pipe to use to maximize the pump capacity or discharge. Thanks.
@1EliAbby1
@1EliAbby1 3 жыл бұрын
Thanks for the great explanation. I want to make sure I've understood it correctly, and I also have a few questions. We live on an 11-acre property that a developer wanted to subdivide. The developer drilled a well, intending it to be a community well, but it only delivers 10 gpm, and was not suitable to supply 11 houses. We bought the property from the developer and used this well to supply our new house. The well is 800' deep, has an 8" casing, and delivers 10 gpm. The submersible well pump is set at 300' The static water level is at 30'. It is 80' from the wellhead to the pressure tank inside the house The difference in elevation between the wellhead and the house is only 10' (the house is 10' higher than the wellhead). The well has 1" poly pipe. Question#1: If we never consume more than 10 gpm, and the flow rate of the well is 10 gpm, will there still be a drawdown from the static water level? Question #2: Without taking into account any additional head from possible drawdown, or friction losses from fittings, I calculate my head to be 270' (distance from well pump to static water level) +10' (difference in elevation between the wellhead and the house) + friction loss of 300' of pipe in the well + 30' of pipe between the static water level and top of the well + 80' of pipe between the well and the pressure tank in the house. So this would be 270' + 10' = 280' of head + the friction loss of 30'+80' of poly pipe. Am I correct about this? Question #3: If a 1hp, 10 gpm pump is used, but only a 3/4 hp, 10gpm pump is needed because of the amount of TDH, will the overly powerful pump be at risk of damaging its bearings from upthrust, because the head pressure is not adequate to keep impeller of the more powerful pump from banging into the top bearing when the pump turns on? Thanks for any answers to these questions.
@RCworstwater
@RCworstwater 3 жыл бұрын
Great questions, Q1: Only seasonal changes would likely effect the static water level in the instance you described. Q2: You are correct other than accounting for friction loss in fittings. Q3: I will refer to my own made up analogy, a pump is like a shoe, you don't go to large or to small for optimal and reliable performance. We are more than happy to help you size and select a pump if you contact us.
@athulprakash1209
@athulprakash1209 4 жыл бұрын
What is free delivery head in a pump? How can delivery head be zero even when there is flow through the pump?
@basilkhan5153
@basilkhan5153 3 жыл бұрын
thanks
@mohammadadil48
@mohammadadil48 7 жыл бұрын
My question is if height of a building is 40 meter and pumping system is placed at the ground level What will be pressure reading at the suction of the pump and at the discharge of the pump
@lenkastejskalova1769
@lenkastejskalova1769 6 жыл бұрын
Static x Love dub
@hussain7495
@hussain7495 4 жыл бұрын
Thanks
@RCworstwater
@RCworstwater 4 жыл бұрын
You're most welcome!
@thermocoolofficials6499
@thermocoolofficials6499 3 жыл бұрын
Dear Sir.Thank you for the video.Please advise .My question is that elevation still get in to tatal head if the pipe is close loop?
@RCworstwater
@RCworstwater 3 жыл бұрын
Yes, it is
@branchingtraditions9220
@branchingtraditions9220 2 жыл бұрын
Does friction loss get accounted for in the length of pipe (drop pipe?) that is going down the well since that is already getting counted somewhat in the lift/elevation part of the equation? Meaning if the pump is hanging higher or lower in the well, I need to increase or decrease both elevation and total length of pipe that is causing friction loss.
@RCworstwater
@RCworstwater 2 жыл бұрын
Yes, because friction loss and elevation are two separate components of the equation.
@yarzarm
@yarzarm 5 жыл бұрын
Subscription links are not working.
@satrah101
@satrah101 7 жыл бұрын
Hello R.C. Worst & co, great channel well done for putting these videos together. Is pump head the same as suction. Max-head and max suction. Many thanks in advance.
@RCworstwater
@RCworstwater 7 жыл бұрын
Hey Wayne! Suction Lift refers to the difference in elevation measured from the pump's inlet to the water level, and only applies to surface pumps. Think of it like the pump is sucking water straight up out of a cup (well/lake) with a straw (pipe). For shallow well jet pumps, the maximum suction lift is about 25', deep well jet pumps can lift from over 100'. Max head refers to the maximum amount of pressure (PSI) a pump can produce, and is a characteristic of ALL water/wastewater pumps. Thanks for the question!
@satrah101
@satrah101 7 жыл бұрын
Thank you, that makes it clearer. first time working with pumps. i will watch many more from your channel.
@gjmheating8857
@gjmheating8857 6 жыл бұрын
Hello you mention you can have a desired pressure what does this mean exactly
@tylerbrown2938
@tylerbrown2938 3 жыл бұрын
Some systems have a certain flow rate requirement in order to operate properly. So maintaining a pump at a desired discharge pressure helps ensure this is done properly. Also if a pump is not pumping at a desired/required pressure, possible indication of something wrong with the pump or equipment upstream or downstream of it.
@siddheshnaik71
@siddheshnaik71 5 жыл бұрын
What if the pump is situated above a tank will that be called as negative head or something and also how the head of the liquid fuels can be determined in an rocket engine as the pumps are situated above the combustion chamber in which the fuels have to be pumped
@RCworstwater
@RCworstwater 5 жыл бұрын
Suction lift is the term for a pump that pulls water from a lower elevation. I have not dealt with rocket fuel pumps recently, that may be a question for NASA.
@Mike-lx8ll
@Mike-lx8ll 6 жыл бұрын
Hi, how much head loss would a filter sock add to a pool pump setup?
@RCworstwater
@RCworstwater 6 жыл бұрын
It depends on the size, micron rating, and flow rate. Generally though they are sized to lose less then 1 or 2 psi.
@mohsenz8456
@mohsenz8456 3 жыл бұрын
Hi sir, I have a question. How we can calculate the head of a pump when that pump is higher than its consumers?For example,, the pump is on the roof and pumping water for domestic buildings. Thanks
@dubemmba9602
@dubemmba9602 3 жыл бұрын
The static head would be considered the same magnitude as at when you elevate but with a negative value because the reference plane is taking at x=0 at the center of the pipe. So your total head loss or total dynamic head would be Tdh=sh+dh+fl with static head negative
@marcs5790
@marcs5790 2 жыл бұрын
I need help sizing a sewage ejector pump
@ArchieBald38
@ArchieBald38 3 жыл бұрын
"Friction Loss Calculators" - could you please share this file? I am not able to download, seems so the download link is not there anymore
@RCworstwater
@RCworstwater 3 жыл бұрын
Sorry about that! Here is a decent one: bit.ly/32v9RoB
@EPC-ue2ci
@EPC-ue2ci 5 жыл бұрын
I have been very curious as to why Head is given as a distance? Is head simply the extra distance that would be needed to overcome by the pump or pressure from point A? Is that why its given in meters? My question stems from the definition of head loss specifically. Head loss as we know is the pressure lost due to the friction in a pipe. But I am confused as to why its units is meters specifically. From my understanding the reason is friction causes the fluid to lose a certain amount of distance when traveling at a certain velocity and this distance lost must then be overcome by extra pressure from point A? is this correct?
@RCworstwater
@RCworstwater 5 жыл бұрын
That's a good question, here's a link to an excellent article that I think will answer your question: www.pacificliquid.com/pumpintro.pdf
@zacharysylvester8349
@zacharysylvester8349 5 жыл бұрын
Depending on the fluid in question, head can be directly converted from distance to the pressure gradient. It is important to stress that this conversion is for the pressure GRADIENT and not merely pressure at a given point.
@hosams8034
@hosams8034 5 жыл бұрын
1psi=2.31 feet when i use water, what about using other liquieds, like disel for example?
@prabesh321
@prabesh321 5 жыл бұрын
hosam s just multiply by the specific gravity
@hodown1735
@hodown1735 4 жыл бұрын
do you have any animated power-point presentations?
@RCworstwater
@RCworstwater 4 жыл бұрын
Not at this time.
@CBREWORK
@CBREWORK 4 жыл бұрын
How do i convert pump pressure to head? I see two ways people are using P x 2.31 or pump differential x 2.31?
@RCworstwater
@RCworstwater 4 жыл бұрын
1 PSI = 2.31 feet of head
@CBREWORK
@CBREWORK 4 жыл бұрын
Is it better to use pump differential or just gauge pressure?
@rajeshkumar-jo6pl
@rajeshkumar-jo6pl 2 жыл бұрын
What is the worst in case low head
@shishirhowlader7170
@shishirhowlader7170 11 ай бұрын
Pump head 107-45, what does it mean?
@engineerhashimcirrochannel3443
@engineerhashimcirrochannel3443 4 жыл бұрын
Make clip on calculation of flow rate, head, power requirment, friction loss, roar dynamic head
@haduahabeeb4883
@haduahabeeb4883 4 жыл бұрын
The PDF link is not working
@RCworstwater
@RCworstwater 4 жыл бұрын
Thanks for the heads up! I changed it, here's the new link: www.rcworst.com/Shared/content/mfr/a_y_mcdonald_mfg_co/docs/a_y_mcdonald_pump_basics19.pdf
@arun4846
@arun4846 2 жыл бұрын
👍
@mrjones422
@mrjones422 5 жыл бұрын
Not a bad video but it is always a better video if you give a real world example with actual numbers. For the lift, why is there not a difference of head based on pipe size? Surely lifting a 2" diameter column of water a foot takes less force (ie less pressure) than lifting a 6" diameter column of water a foot. I would think a calculation that takes into account the specific gravity of the fluid (ie water) with the volume of water that would be lifted. Maybe this is just for "simple" applications per the title, but lifting a 1" diameter column of water 100 feet cannot be the same as lifting a 16" diameter column of water.
@RCworstwater
@RCworstwater 5 жыл бұрын
Thanks for the comment! The diameter of the pipe is only needed to account for friction loss, the pressure at the bottom of your 1" dia. and 16" dia column are exactly the same -> 43.29 PSI (ignoring friction loss). That is the pressure the pump must be able to produce to push water out regardless of pipe size. You can learn more here: www.rcworst.com/Shared/content/mfr/a_y_mcdonald_mfg_co/docs/a_y_mcdonald_pump_basics.pdf
@joker2712005
@joker2712005 5 жыл бұрын
This was not a simple explanation..
Pressure, head, and pumping into tanks
6:44
Process with Pat
Рет қаралды 264 М.
How to Read Pump Chart and Select Pump
16:15
MEP Academy
Рет қаралды 31 М.
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 60 МЛН
تجربة أغرب توصيلة شحن ضد القطع تماما
00:56
صدام العزي
Рет қаралды 58 МЛН
Looks realistic #tiktok
00:22
Анастасия Тарасова
Рет қаралды 105 МЛН
Checking Pump Performance (Dead Head Check)
6:10
Zen HVAC
Рет қаралды 126 М.
How to Read a Pump Curve: Simple Explanation
15:23
R.C. Worst & Co., Inc.
Рет қаралды 127 М.
What is Static Head Pressure, Friction Head & Total Dynamic Head?
9:03
Sizing a submersible pump: Some things to know to get it right.
6:03
Irrigear® Independent Experts
Рет қаралды 13 М.
Flow and Pressure in Pipes Explained
12:42
Practical Engineering
Рет қаралды 994 М.
Pipe Size Matters - How to Read Irrigation Friction Loss Charts
10:34
Sprinkler Nerd Andy
Рет қаралды 29 М.
Pump total Dynamic Head Calculation
6:01
The Practical Study
Рет қаралды 120 М.
Learn How to Read a Pump Curve in Minutes | Best Simple Explanation
3:38
Flood Protection Solutions Ltd | FPS Group®
Рет қаралды 12 М.
Pump Chart Basics Explained - Pump curve HVACR
13:05
The Engineering Mindset
Рет қаралды 1,8 МЛН