Purpose of Bed Drain and Bed Charging in Boiler? | Bed Drain | Bed charging in AFBC Boiler |

  Рет қаралды 68,325

Power Plant Discussion

Power Plant Discussion

Күн бұрын

Hello friends,
"Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
Email
powerplantdiscussion@gmail.com
Website
/ @powerplantdiscussion (Company Website)
LinkedIn
/ power-plant-discussion...
#PowerPlantDiscussion
#BedDrain
#BedCharging
#AFBCboiler
Thanks to all of you for connecting me.

Пікірлер: 79
@shailendrajadon3599
@shailendrajadon3599 2 жыл бұрын
Sandhar explain sir...
@BAPKP
@BAPKP 6 ай бұрын
You are very knowledgeable person ❤ The way you teach is superb
@amrendrakumarsingh5126
@amrendrakumarsingh5126 2 жыл бұрын
Excellent
@parimalbhavsar2513
@parimalbhavsar2513 2 жыл бұрын
Good job 👍🆗👏👌👍👍👌👌👏👌👌
@ashoktagarisha5168
@ashoktagarisha5168 2 жыл бұрын
Superb explanation sir
@ameeranna5030
@ameeranna5030 2 жыл бұрын
Super explanation sir 👍
@vedprakashratnani3129
@vedprakashratnani3129 2 жыл бұрын
Good
@dhanendrakashyap6323
@dhanendrakashyap6323 2 жыл бұрын
Nice sir ji
@ashokawasthi2959
@ashokawasthi2959 2 жыл бұрын
Very good video sir
@dineshpathak5407
@dineshpathak5407 2 жыл бұрын
t
@gauravkumarpandey67
@gauravkumarpandey67 8 ай бұрын
👌
@rajkumartiwari780
@rajkumartiwari780 Жыл бұрын
Nice sar
@kumararvind3164
@kumararvind3164 Жыл бұрын
Super explain sir j
@vikashkumarsingh8983
@vikashkumarsingh8983 2 жыл бұрын
Very nice video
@dakeshkumar1397
@dakeshkumar1397 2 жыл бұрын
Sir soot blower ke bare me video banav
@tiwariravishankar8967
@tiwariravishankar8967 2 ай бұрын
Sir, everything is correct and we have understood completely but this manual charging is very risky.
@ashishvitekar3474
@ashishvitekar3474 2 жыл бұрын
Very nice explain and informative video's. Sir, what is the density of bed material and density of Ash and how only ash comes at the drain point only. Thanks a lot
@vedprakashratnani3129
@vedprakashratnani3129 2 жыл бұрын
Sir. Downcomer tube furnace ke bahar kyu rakhte hai? And feed water pura waterwall me nahi aata par steam drum se water drum aitha steam drum me aesa kyu?
@DheerajKumar-be5kj
@DheerajKumar-be5kj 2 жыл бұрын
Sir boiler Compressor and condensor pr video bnaiye
@DheerajKumar-be5kj
@DheerajKumar-be5kj 2 жыл бұрын
We are waiting sir
@powerplantdiscussionbengal2525
@powerplantdiscussionbengal2525 Жыл бұрын
Awesome explain
@JitendraKumar-er1yy
@JitendraKumar-er1yy 2 жыл бұрын
Thanks Sir
@vedprakashratnani3129
@vedprakashratnani3129 2 жыл бұрын
Sir. Ek bed me se dusre bed me Ash carryover hota ho to kya reason ho sakta hai
@saswatpattanaik8329
@saswatpattanaik8329 2 жыл бұрын
sir please one vedio for what is the work of furnace internal
@MuhammadFarooq-qk1lk
@MuhammadFarooq-qk1lk 2 жыл бұрын
Sir,Please make a vedio boiler refrectory material
@rattamarengineer6113
@rattamarengineer6113 2 жыл бұрын
Sir mee plant me vacuum drop hone ke kya kya reasons ho sakte hai please video banaye ya comments me answer digiye
@dharmeshkara6419
@dharmeshkara6419 2 жыл бұрын
coal me unburn partical and lime feeding se bhi height high ho sakta hai...right sir
@nishukr5266
@nishukr5266 2 жыл бұрын
If percentage of flyash increased in eco or aph then what should be our thinking .. What are the merit or demerit of it ...
@vimalkumar-xc1sm
@vimalkumar-xc1sm Жыл бұрын
Sir crude palm oil Refinery ke loss ke calculation bata dijiye
@nb-pc4dy
@nb-pc4dy 2 жыл бұрын
Sir coal aur dolo char ka mixing ratio ke bare me bataiye. Kyun ki sab plant me coal 100% use nahi hota hai dolo char se boiler chalate hain. reply dijiye ga sir 🙏 mera jan na bahut jaruri hai.
@PowerPlantDiscussion
@PowerPlantDiscussion 2 жыл бұрын
Dear for this I decided to make separate video very soon got notifications.
@nb-pc4dy
@nb-pc4dy 2 жыл бұрын
@@PowerPlantDiscussion thank you ❤️
@generalknowledge7136
@generalknowledge7136 2 жыл бұрын
Pressure or steam quantity ka kya relation hota hai For example Suppose hum 6kg/cm2 pe 1.6ton steam produce kr rhe per hour (2TPH boiler capacity) Now instead of 6kg/cm2 se pressure ko 8kg/cm2 pe steam generate krne lge To 2kg/cm2 pressure increase hone se steam quantity pe kya effect pdega
@PowerPlantDiscussion
@PowerPlantDiscussion 2 жыл бұрын
As we know as pressure and temperature increases enthalpy of steam increases. So if you increase pressure or temperature steam production with high enthalpy so steam consumption is reduced
@generalknowledge7136
@generalknowledge7136 2 жыл бұрын
Production of Steam will remain constant
@PowerPlantDiscussion
@PowerPlantDiscussion 2 жыл бұрын
Calculate enthalpy at both conditions And we know our turbine is design for desired heat rate, so for short period of time this can't be predict but if you want to see their effect, you should maintain constant parameters in a single shift.
@generalknowledge7136
@generalknowledge7136 2 жыл бұрын
Okk sir
@ompalyadav824
@ompalyadav824 2 жыл бұрын
Sir please bed hight menten AFBC boiler par video bnaeye 🙏
@overthink17
@overthink17 2 жыл бұрын
Sir I have also seen that some of the fuel particle...(like coal) also drain out through drain pipes! How is this possible...if we have AFBC boilers....?
@nb-pc4dy
@nb-pc4dy 2 жыл бұрын
Sir humara plant me bed material charge nahi karte to bed material drain ho ja raha hoga aur charge nahi karte to iss se kya effect padega ya nahi?
@PowerPlantDiscussion
@PowerPlantDiscussion 2 жыл бұрын
Agr bed temperature maintain h to koi dikkat ni h
@nb-pc4dy
@nb-pc4dy 2 жыл бұрын
@@PowerPlantDiscussion per kuchh bed material to. Drain ho ja raha hoga,thoda thoda bed material drain hoga bed material ka percentage to kam ho jayega na.
@gauravpanchal6148
@gauravpanchal6148 2 жыл бұрын
How to specifying top and bottom side in AFBC Boiler.??
@vsaktharhussain
@vsaktharhussain 2 жыл бұрын
Can you please explain that esp not charging , even by pass drain also opened and ash handling system also working..... What's the reason.....
@PowerPlantDiscussion
@PowerPlantDiscussion 2 жыл бұрын
Sure
@vsaktharhussain
@vsaktharhussain 2 жыл бұрын
@@PowerPlantDiscussion thank u
@maheshgoud8876
@maheshgoud8876 2 жыл бұрын
Try to change ESP Controller then charge, if it charges no problem, if didn't get charge it might be the internal problem (emitting electrode might be body)
@44-drashtisolanki81
@44-drashtisolanki81 3 ай бұрын
Sir afbc boiler ke under Loi maintain kaise Krte hay uska detail chaiye
@amitpal6015
@amitpal6015 2 жыл бұрын
Sir boiler par load kam hone par b.f.p section chod de raha h pls reson kya h
@ritucreativity3889
@ritucreativity3889 2 жыл бұрын
Sir please aap ek distillation column ka ethanol and methanol recovery ka bhi ek video banao na
@bijayketanswain6719
@bijayketanswain6719 4 ай бұрын
Sir how line safety check in running boiler
@rajnishtembhekar6899
@rajnishtembhekar6899 2 жыл бұрын
Where is null point in boiler
@purab151
@purab151 2 жыл бұрын
Sir, what is difference between boiler bed material and refractory?
@nesifkadivar7313
@nesifkadivar7313 4 ай бұрын
Hello
@purab151
@purab151 4 ай бұрын
@@nesifkadivar7313 yes??
@rakeshpandey5600
@rakeshpandey5600 4 ай бұрын
Sir jab plant blackout ho jata hai to hume us time kya kerte hai, boiler per
@lyricsworld9958
@lyricsworld9958 Жыл бұрын
Sir fbc boiler main sand ku use ki jati hy?plz
@ompalyadav824
@ompalyadav824 2 жыл бұрын
Sir please furnace tempcture high low par video please sir,,🙏
@mehadihasan1068
@mehadihasan1068 Жыл бұрын
Sir kitna main steam flow pe kitna FD flow rkhte h
@k.gautam3350
@k.gautam3350 Жыл бұрын
600 mw me NH3 treatment (dosing) karte hai, if pH is 11 then what will effect
@nirajpatel-nv4pj
@nirajpatel-nv4pj 5 ай бұрын
Normal bed tamprature kitna hona chahiye
@dharmendarrishidev2341
@dharmendarrishidev2341 Жыл бұрын
mobry fel hojaye to feed pump kese start kare
@abhishekmandal2035
@abhishekmandal2035 2 жыл бұрын
In which powerplant u are working
@PowerPlantDiscussion
@PowerPlantDiscussion 2 жыл бұрын
I can't share my personal info here, Please contact me through powerplantdiscussion@gmail.com
@swapnilpardhi8651
@swapnilpardhi8651 2 жыл бұрын
Sir ji bed me use hone wale sand ko kya kahte hai
@pramodmishra405
@pramodmishra405 Жыл бұрын
What is difference between over bed and under bed feeding?
@vaisahmed5754
@vaisahmed5754 2 жыл бұрын
Sir boiler ka heating surface area se boiler ki capacity kaise pata karenge
@audiobookshindi4877
@audiobookshindi4877 2 жыл бұрын
Sky alloys ka ladka
@dhruvdhimmar144
@dhruvdhimmar144 2 жыл бұрын
Please Use PPE before Bed Drain and Charge Activity.
@PowerPlantDiscussion
@PowerPlantDiscussion 2 жыл бұрын
Yes you are correct
@RakeshKumar-bq9xq
@RakeshKumar-bq9xq 2 жыл бұрын
good morning sir. sir ppe means
@PowerPlantDiscussion
@PowerPlantDiscussion 2 жыл бұрын
Personal protective equipment
@gubbalasatya9723
@gubbalasatya9723 2 жыл бұрын
How much iron% in bedash maintain afbc boiler ?
@VishalKurmi-rz7di
@VishalKurmi-rz7di 9 ай бұрын
Sir muje 267 tph boiler ke liye Ap se class lena he please sir
@laxminarayanapanigrahi1431
@laxminarayanapanigrahi1431 2 жыл бұрын
Good explanation but poor in calculation.
@PowerPlantDiscussion
@PowerPlantDiscussion 2 жыл бұрын
Please suggest me what should be improvement
@rathavabhursingrathavabhus3753
@rathavabhursingrathavabhus3753 Жыл бұрын
Hii
@VishalKurmi-rz7di
@VishalKurmi-rz7di 9 ай бұрын
Sir muje Ap se class lena he
Logo Matching Challenge with Alfredo Larin Family! 👍
00:36
BigSchool
Рет қаралды 21 МЛН
ОБЯЗАТЕЛЬНО СОВЕРШАЙТЕ ДОБРО!❤❤❤
00:45
#AFBC boiler। Bed sluming and bed activation
12:32
A2 technical power
Рет қаралды 1,9 М.
How Boiler PA Fan & FD Fan Blade pitch control work  in Thermal power Plant ?
11:41
Power Plant with Pratyush
Рет қаралды 3,9 М.
CIRCULATING FLUIDIZED BED BOILER
3:03
İymer Group
Рет қаралды 19 М.
Logo Matching Challenge with Alfredo Larin Family! 👍
00:36
BigSchool
Рет қаралды 21 МЛН