No video

Q Exactive

  Рет қаралды 55,497

adrabovich

adrabovich

Күн бұрын

Narrative script and presentation by Ihor Batruch

Пікірлер: 14
@alextrevelian
@alextrevelian 5 жыл бұрын
Finally someone took the job of explaining each step since the original one is without audio and is very boring when you want to show it to students. Thanks!
@violindalola
@violindalola 4 жыл бұрын
I know right! SMDH the original video was useless. This video rules.
@h.k.2511
@h.k.2511 7 жыл бұрын
Good job Ihor.
@jimiwills
@jimiwills 7 ай бұрын
It's actually the frequency of oscillation along the axis that's measured across the pair of outer electrodes though, right? Not the rotation.
@alejandra1888
@alejandra1888 4 жыл бұрын
Hi! Thank you for this video. Your explanations are really clear. But still, I don not understand, in the MS2 mode, once the quadrupole has selected the ion of interest (precursor), where the other ions go? And after the analysis of the first set of ions in the Orbitrap, where do the next set of ions come from? Thank you for your priceless help
@andreidrabovich3921
@andreidrabovich3921 4 жыл бұрын
Alejandra, Quadrupole acts as a filter, so only certain precursor ions, let’s say 500+-0.5 m/z, could pass, while other ions become unstable, hit the wall, turn into neutrals, and cannot move forward. Thus, only packets of 500+-0.5 m/z are proceeding for fragmentation. Also note that one MS1 scan is followed by 10 or more MS2 scans. During the MS1 full scan, the software determines top 10 most intense precursor ions at that point in time. In the subsequent 10 MS/MS scans, the software tells quadrupole to open for 500+-0.5 m/z, fragment that top 1 packet of ions by HCD, and measure fragments in the Orbitrap. Following that, it then tells quadrupole to open for the top 2 precursor, let’s say 600+-0.5 m/z, fragment that packet, and measure. After completion of all top 10, the next cycle of MS1-10 MS/MS starts.
@felipevasquez8393
@felipevasquez8393 4 жыл бұрын
@@andreidrabovich3921 There's still something I don't understand. I have had spectra measured in an Orbitrap, and I see that the software shows the fragments for a precursor ion of exact mass. How can one select a precursor ion of exact mass using a quadrupole analyzer? Thank you.
@andreidrabovich3921
@andreidrabovich3921 4 жыл бұрын
@@felipevasquez8393 Precursor ions (MS1) are indeed measured with Orbi, while quadrupole is nearly fully open. The fast quadrupole analyzer is then used to select the first narrow pack of MS1 ions (for example, 500+-0.5 m/z) for the subsequent fragmentation and measurement of MS2 fragments with Orbi. The quadrupole then goes for the second narrow pack of MS1 ions (for example, 600+-0.5m/z). And so on, to complete the Top20 cycle.
@felipevasquez8393
@felipevasquez8393 4 жыл бұрын
@@andreidrabovich3921 Oh, I see. Thank you for your response!
@jaqsingdo
@jaqsingdo 6 жыл бұрын
thank you for the video.
@erikhenze2339
@erikhenze2339 Жыл бұрын
How does this tandem MS/MS result in having a high-resolution precursor mass ion if the precursor is being selected in the quadrupole instead of the orbitrap?
@ianmatthewkline8279
@ianmatthewkline8279 2 жыл бұрын
Best explanation out there. Very scripted lol but very clear and thorough
@vinceb8041
@vinceb8041 3 жыл бұрын
Quick question: When an orbitrap mass spectrometer records a full MS1 spectrum, does the quadrupole do anything in terms of exclusion? I know that in SIM mode, the RF frequency is ramped to selectively let certain m/z pass and get to the detector, but an Orbitrap can basically record a full spectrum all at once, right?
Quadrupole Ion Trap Mass Spectrometer
15:22
ShortChemistry
Рет қаралды 34 М.
Thermo  Orbitrap Fusion Animation
5:06
jamie humphries
Рет қаралды 163 М.
SCHOOLBOY. Последняя часть🤓
00:15
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 13 МЛН
Parenting hacks and gadgets against mosquitoes 🦟👶
00:21
Let's GLOW!
Рет қаралды 13 МЛН
Happy birthday to you by Tsuriki Show
00:12
Tsuriki Show
Рет қаралды 10 МЛН
Mass Chromatograms
16:34
ShortChemistry
Рет қаралды 25 М.
Overview of the Q Exactive Plus and Ultimate 3000 Instruments
32:41
Environmental Proteomics Lab Tutorials
Рет қаралды 9 М.
Ask the Expert - Orbitrap Exploris 120 mass spectrometer - Resolution
9:52
Chromatography & Mass Spectrometry Solutions
Рет қаралды 3,6 М.
Quickly understand various types of LCMS
7:59
Shimadzu Asia Pacific
Рет қаралды 9 М.
Orbitrap Mass Spectrometer | Dr. Saravanan Kumar | CSI
1:11:13
Chromatographic Society of India
Рет қаралды 8 М.
Take a tour of the new Thermo Scientific Orbitrap Exploris 240 LC-MS flying ions animation video
5:09
Chromatography & Mass Spectrometry Solutions
Рет қаралды 10 М.
Tandem Mass Spectrometry
13:26
ShortChemistry
Рет қаралды 46 М.
SCHOOLBOY. Последняя часть🤓
00:15
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 13 МЛН