Raychem plug-in termination (RPIT)

  Рет қаралды 147,242

All Round Supplies

All Round Supplies

Күн бұрын

Watch how to correctly install a Raychem plug-in termination (RPIT).
For more information or to purchase jointing and termination materials, please visit: www.all-round-supplies.com.au/....

Пікірлер: 19
@metaladder1018
@metaladder1018 7 жыл бұрын
Have a neighbor that does this type of work and I've learned a lot more about electrical.
@PBWillyWonka
@PBWillyWonka 7 жыл бұрын
Impressive!!
@user-sc1nm9uw8x
@user-sc1nm9uw8x 7 жыл бұрын
إبداع وإتقان شكرا على هذا الفيديو
@randihoman2076
@randihoman2076 7 жыл бұрын
علي عiسddيري idjdjdu
@TheSvenerHST
@TheSvenerHST 7 жыл бұрын
The cable for the screen is misprinted. From closed to open is properly pressed
@jiesheng32000
@jiesheng32000 7 жыл бұрын
very interesting but may i know why is a cable termination required? aren't all cables supposed to connect things together?
@AllRoundSupplies
@AllRoundSupplies 7 жыл бұрын
Hi Jackson, for medium and high voltage underground cables (typically 11kV and above), cable terminations are required to control the electrical stress in the cable at the termination point. There are various types of terminations available for medium and high voltage underground cables to suit different types of switchgear and transformer bushings - the Raychem RPIT plug-in termination is one such termination and is used for terminating 11kV to 33kV cables to switchgear with plug-in type bushings.
@godfreypoon5148
@godfreypoon5148 7 жыл бұрын
The cable "terminates" where it connects to the thing.
@saeedpirdehghan5612
@saeedpirdehghan5612 2 жыл бұрын
Very good,
@douro20
@douro20 3 жыл бұрын
Do they make a cold-shrink boot for these nowadays?
@AllRoundSupplies
@AllRoundSupplies 3 жыл бұрын
The Raychem RPIT termination is a cold applied plug in termination - no heat is required for the actual cable termination. A heatshrink sealing sleeve is provided to seal the cable entry onto the cable itself. The heatshrink sealing sleeve is still recommended for this due to the size difference between the cable entry and the cable. The heatshrink sleeve will set in place once it cools, a cold shrink sleeve will continue to try to shrink and could work its way off of the cable entry onto the cable. Hope this helps!
@ziahaq5019
@ziahaq5019 3 жыл бұрын
This is 33 kv plug in termination plz I need its measurements any body help me
@bilawalkhan8404
@bilawalkhan8404 5 жыл бұрын
you forget to put the force spring under the insulation cone
@godfreypoon5148
@godfreypoon5148 7 жыл бұрын
Should have just propped it up on some chopsticks. If it's over 3.3kV, be sure to use clean chopsticks.
@Gameboygenius
@Gameboygenius 7 жыл бұрын
True. For over 20 kV, preferably use plastic chopsticks.
@mudo7948
@mudo7948 7 жыл бұрын
слищком долго...наши побыстрее все это сделают.
@user-jt3nf7in5w
@user-jt3nf7in5w 7 жыл бұрын
Gosh just wrap some electrical tape around it and put it back in the ground lol
@TheJMurray703
@TheJMurray703 7 жыл бұрын
This is an over engineered and expensive option to existing technology that has been used in the USA for decades. What they don't show in the video is the other half of the termination that needs to be part of the switchgear or transformer you are connecting to. That component would need to be installed by the switchgear or transformer manufacturer again in place of bushings that have been the standard in the USA for decades. This too is expensive and would add cost to what is standard equipment for a redesign.
@AllRoundSupplies
@AllRoundSupplies 7 жыл бұрын
Thanks for your feedback, Jim. In Australia some MV switchgear types are supplied with plug-in type bushings which require plug-in type terminations, All Round Supplies stocks a full range of termination options for various bushing types. The plug-in termination is only one type of termination in our range, other termination types include moulded elbow terminations for type A, type B and type C profile bushings, heatshrink terminations for air boxes and pole top applications, and cold applied terminations for air boxes and pole top applications.
Installation of a Heatshrink Termination on a Three-core MV Armoured Cable
16:12
REPL International Ltd.
Рет қаралды 155 М.
HV-CONNEX Installation (short version)
3:01
PFISTERER
Рет қаралды 54 М.
Omega Boy Past 3 #funny #viral #comedy
00:22
CRAZY GREAPA
Рет қаралды 17 МЛН
ELE QUEBROU A TAÇA DE FUTEBOL
00:45
Matheus Kriwat
Рет қаралды 11 МЛН
TE's Raychem Cold Shrink Disconnectable Joint Installation Video
11:43
110kV XLPE GIS Sealing end
12:18
Yingwei Wang
Рет қаралды 42 М.
MXSW Raychem MV 3c XLPE SWA joint
4:59
All Round Supplies
Рет қаралды 25 М.
Medium Voltage Heat Shrink Termination Installation
18:42
3M India
Рет қаралды 25 М.
Heat Shrink Cable Joint - 11kV 3 Core XLPE & EPR High Voltage Cable Joints
19:14
Resin Straight Joint WMB 24kV 3Cx240mm2  Cellpack
18:03
Son Dinh
Рет қаралды 1,3 МЛН
35KV 3 core Cold Shrink Indoor Termination Kit Installation - 9V
9:42
3M™ Standard MV Cold Shrink Joints with Taped Electrode
9:04
3M UK & Ireland
Рет қаралды 1,6 МЛН
🤔Почему Samsung ПОМОГАЕТ Apple?
0:48
Technodeus
Рет қаралды 434 М.