Replacing an Underground Water Line with Trenchless Method

  Рет қаралды 93,730

Zippy Plumber

Zippy Plumber

6 жыл бұрын

Zippy Plumber's professionals have the experience, knowledge, and tools to repair or replace your water line in one day using any trenchless or underground method of repair.
Zippy Plumber: zippyplumber.com/
Water Line Repair: zippyplumber.com/trenchless-w...

Пікірлер: 56
@stacystarnes1449
@stacystarnes1449 2 жыл бұрын
Thats pretty slick! I'm thinking that the home owner saved a ton of money too. Great job!
@rumpstatefiasco
@rumpstatefiasco Жыл бұрын
GENIUS method. This excellent video is a great service to the general public. THANK YOU.
@PL36012
@PL36012 10 ай бұрын
Great video, thanks for taking the time to post.
@db8823
@db8823 Жыл бұрын
Very cool, love those compression fittings.
@Agrofind6161
@Agrofind6161 Жыл бұрын
The video you shared is very helpful! hope to be your companion in the future, thank you for everything!👍🙏🙏🙏🙏🙏🙏
@shudarschway9479
@shudarschway9479 Жыл бұрын
great informative video. Love the procedure and the thorough explanation
@TimHPop776
@TimHPop776 Жыл бұрын
Wow!! Absolutely phenomenal!!
@smokemirrors519
@smokemirrors519 2 жыл бұрын
Brilliant. I’m a Multi-craft Technician but I’m making a career change. This is amazing
@grasshopperfiddler
@grasshopperfiddler 2 жыл бұрын
Thats simply amazing
@TruthfulNews.at.Tell.a.gram7
@TruthfulNews.at.Tell.a.gram7 7 ай бұрын
Excellent work 👍🏻
@mervelmatthew642
@mervelmatthew642 6 ай бұрын
Love that concept
@marilynm8812
@marilynm8812 Жыл бұрын
Very impressive.
@timeorspace
@timeorspace 2 жыл бұрын
Great video! I'm replacing my 1cuft/hr leak, 30+ YO buried copper service line via a home warranty company, and counter to mine and the service technician's suggestion of trenchless replacement, the company wants to spot repair my 30+ YO buried copper pipe. I called the plumbing company, then the warranty company, and I hope a second, third, fourth, etc opinion can deliver trenchless replacement. It does seem like the tools could be paid for with one or two jobs, and the work could last another decade. This video has helped re-affirm my stubborn-ness...I am impressed it made the corner, will this slitter method work for a straight run of Copper too?
@scottwillis5434
@scottwillis5434 2 жыл бұрын
Looking at the new tubing twisting going in, have you considered supporting it with some sort of bearing arrangement? Say, one of those expandable reels like they use at the hardware store when you buy cut-to-length wire. Pay for itself the first time the tubing kinks.
@phishhu
@phishhu 2 жыл бұрын
Can you do that when replacing buried copper?
@nelsonsmechanicalllcnelson9248
@nelsonsmechanicalllcnelson9248 Жыл бұрын
Pretty cool 👍🏾👍🏾
@Junk65
@Junk65 5 ай бұрын
excellent !!!!
@thepsychonaut8212
@thepsychonaut8212 4 ай бұрын
Can they split copper like that?
@greenhouseplumbing7124
@greenhouseplumbing7124 3 жыл бұрын
great job guys , what state was this recorded ?
@ChefDevo1776
@ChefDevo1776 6 ай бұрын
Genius
@slaydesantis294
@slaydesantis294 2 жыл бұрын
I have galvanized pipe. I'm getting an estimate and they do trenchless. I'm glad they won't have to tear up my driveway, and I'm not that far from the curb. So that's a plus.
@davidnewkirk2438
@davidnewkirk2438 Жыл бұрын
How did your replacement go? I have galvanized as well. I’m going to proactively replace my water main before getting new landscaping and sidewalks done. Checking out the different solutions
@slaydesantis294
@slaydesantis294 Жыл бұрын
@@davidnewkirk2438 It went pretty well. They replaced the galvanized that went to the street with a copper pipe (regulations, had to have it copper) and later on, we replaced galvanized inside with pex. When the outside pipe was replaced, the water became clogged up, because there was old pipe inside the house. It happens, I guess. I didn't have a lot of water pressure, until the pex was installed. Love it!
@richardfoister1877
@richardfoister1877 2 жыл бұрын
How did you get the cable threw the old pipe from the meter to the house to pull the pex threw????
@richardt6980
@richardt6980 2 жыл бұрын
probably with a fish tape
@bg147
@bg147 Ай бұрын
Is it safe to assume this won't work with old galvanized pipe?
@redranger518
@redranger518 2 жыл бұрын
Silly to put a PRV that will leak to take off 20 PSI, Should of left water pressure at 80 PSI. I did enjoy the pull in water pipe.
@tylero8595
@tylero8595 Жыл бұрын
80psi is too much. You have to reduce it. At night the city pressure would probably bump up to 100psi. Always a prv.
@redranger518
@redranger518 Жыл бұрын
@@tylero8595 100 psi don't bother me at all, I keep my house around 80. I have seen whole neighborhoods in the 120's. PRV is just another potential leak or break and shut the water pressure down to 20 psi
@redranger518
@redranger518 Жыл бұрын
@@tylero8595 Probably go down in my area, Everyone runs sprinklers for yards almost year round.
@jaimenieto5658
@jaimenieto5658 Жыл бұрын
Around how much is rhis kind of job?
@DaveTheHVACguy
@DaveTheHVACguy 3 жыл бұрын
great way to get the job done. Im in Ohio, I replace water lines..mostly old galvanized..rusted badly...what system do you suggest for this type of material? Where should I look to buy tools needed to pull a line through when there's barely a pencil width of space in the pipe.
@zippyplumber
@zippyplumber 3 жыл бұрын
What part of Ohio, I’m from just outside of Akron.
@Haberdashery1
@Haberdashery1 2 жыл бұрын
Cz z u
@shawndunleavy892
@shawndunleavy892 Жыл бұрын
What state are you in that allows pex underground
@brandonallen914
@brandonallen914 10 ай бұрын
Any way I could figure up the rough cost of this? Currently have 3/4 galvanized underground
@johnpatrickfay5288
@johnpatrickfay5288 2 жыл бұрын
But how did you get pipe puller through system, Information please.
@Casmige
@Casmige 8 ай бұрын
They simply feed a multi-strand pull-cable from the water service supply side up to & over to/through the foundation side & then reverse-pull the pipe splitter through while also pulling the replacement hose.
@billsmith1908
@billsmith1908 Жыл бұрын
I would never have PVC at the wall penetration like that. Asking for future trouble to save $5.
@mervelmatthew642
@mervelmatthew642 6 ай бұрын
Where are u located, and what states do you service
@AbusiveJWsInVentura
@AbusiveJWsInVentura 3 жыл бұрын
Can I run this through galvanized piping? I am desperate as I am working with limited funds? I have a small property in CA.
@cylon5741
@cylon5741 3 жыл бұрын
I do not know the answer to your question. Search for videos on PEX A tubing installation projects by homeowners.
@sislau
@sislau 3 жыл бұрын
I've got galvanized as well. How would a splitter split through metal? I don't see how this method would work. (So back to digging I now go!)
@wendellrountree4899
@wendellrountree4899 2 жыл бұрын
What does something like this cost
@thecinematiccrapalliance
@thecinematiccrapalliance 2 жыл бұрын
I just got an estimate for replacing my service line to the street, and it was $15k. yay
@darktoadone5068
@darktoadone5068 2 жыл бұрын
@@thecinematiccrapalliance How many feet are you from the meter?
@Casmige
@Casmige 8 ай бұрын
WHY…. Did the original build pipe fail??.
@nickgarafolo9359
@nickgarafolo9359 8 ай бұрын
Great video your driver was hauling ass tho
@richarddowns1946
@richarddowns1946 Жыл бұрын
Ha that’s not deep enough where I live!!
@WakeRunSleep
@WakeRunSleep Жыл бұрын
Why use pex over copper?
@readmore3634
@readmore3634 Жыл бұрын
Oh God I count count the ways it's better.
@dustindesalvo
@dustindesalvo Жыл бұрын
If we are pulling a one inch line, we make a 3 inch core hole. And use links seals to make it water tight like a frogs ass. But I like your snatch block. Very nice. Also our water has to be 5 feet deep. Up in NY
@marioreyes6995
@marioreyes6995 2 жыл бұрын
next winter will ne to be replaced again do the same thing with K soft copper, that can be good up to 60 years 😎
@SovaKlr
@SovaKlr Жыл бұрын
why would you let it twist goin in like that... slow down and do a decent job
@pasha_houston
@pasha_houston Жыл бұрын
Thank you for the video. Question: can this be used if the sewage line has a belly ? I am guessing not because that would cause the new line to have a belly as well? Gotta 6-8 ft of a belly on the sewage line causing a back up every once a while. I can't afford to dig a tunnel for it, what would be your advice, what are my choices? Thanks.
Finding and Fixing an Underground Water Leak
21:45
Timothy DC
Рет қаралды 75 М.
home WATER main LINE replacement from meter to house DIY
12:28
Chris Craft
Рет қаралды 74 М.
ПРОВЕРИЛ АРБУЗЫ #shorts
00:34
Паша Осадчий
Рет қаралды 7 МЛН
Trenchless Water Service Replacement
6:13
Zippy Plumber
Рет қаралды 33 М.
Pulling a Service Line With The Service Line Replacement Tool
3:44
New Concept Tools
Рет қаралды 154 М.
Trenchless Experts Install 350' Of New Water Line (Burien, WA)
3:18
Akers Outdoor Plumbing
Рет қаралды 72 М.
How to find an Underground Water Leak?
6:32
Twin Home Experts
Рет қаралды 249 М.
How To Remove OLD Steel Water Pipe And Replace With NEW PEX Piping! DIY
10:48
Trenchless water line replacement + tips and tricks
11:07
KC Plumbing and Rooter
Рет қаралды 30 М.
Bullet Mole Sidewalk Kit
6:35
Bullet Mole
Рет қаралды 959 М.