Here with this video you will learn some of the basic rules of thumb for doing rough in plumbing underground.
Пікірлер: 259
@relerfordable3 ай бұрын
Finally, a simple explanation of the general codes for slab rough plumbing! Thank you. Four years later.
@4PFLikeBaby3 ай бұрын
@relerfordable He touched on good points for codes. But his layout is all wrong.
@relerfordable3 ай бұрын
@@4PFLikeBaby Hahaha! I did my rough the other day. The plumber came in and took most of it apart and said nice try. 🙂
@sawhite27 Жыл бұрын
Good job man. 2 things I learned last year: 1/4" rise is crucial - if you go any higher, you risk having the water run down the pipe faster than the solids do. That means solids will linger and eventually create snag points for further, snags and eventually clogging - possibly. Can reduce this by using the 1/4" rise.
@zhugeliang777 Жыл бұрын
I haven't had luck posting sources so here's a quote that debunks that, you can google it: "Myth To Rest (...) Of course, I found out that the professor was setting me up. This lead to the presentation of a new equation. The equation calculated the minimum flow rate to keep solids in suspension in a sewer system. The inverse of the equation calculated the maximum pitch before the liquids ran away from the solids. Of course, the answer to the maximum pitch was infinity. In other words, you could never reach that point."
@gershambunnell977 Жыл бұрын
Over kill is not always a good thing.
@jguild458 ай бұрын
That's how I remember the rise as well. If you have a rise in excess of 1/4" it could suck you right down the toilet!
@shanetipping24624 жыл бұрын
You are right about simply explained videos not being widely available for the subject. Thank you for this video, very helpful.
@BevinsBuilds4 жыл бұрын
Your welcome and thanks for watching :)
@colleenhammond33772 жыл бұрын
We are looking to build next year and I've been looking for information on this. Thanks so much for sharing - much appreciated!
@stephenorr25292 жыл бұрын
Great tutorial and information. It is nice to have the visuals and the specs as you explained them. Thanks a lot!
@TheRobertralph Жыл бұрын
Thank you. I'm in the same boat. I'm building a barn and want to rough in. Thanks for all of the information! It helped a lot.
@phunwithphiphi80554 жыл бұрын
Great video and excellent tip about the second line on the spirit level, until seeing this I was vague about how to layout my under slab plumbing.
@joshualruby4 жыл бұрын
Use the code recommended slope. Especially if you're getting inspected. They want it to match code, not vary from it. The slope is prescriptive on this for a reason. But it is a good thing to note what the lines mean.
@hlgoodkat96773 жыл бұрын
Well done video, Sir! Thank you. Gave me EXACTLY the info I needed.
@BevinsBuilds3 жыл бұрын
Thanks, glad to hear it.
@msemakweli1332 жыл бұрын
Excellent vid! Great info for my upcoming project. Thanks a lot.
@dylweed243 жыл бұрын
I’m a licensed plumber and this is mostly good advice. Just check the pitch on your pipe. 2in pipe should have 1/4” fall. 3in and 4in pipe should have 1/8” pitch. Also the location of your vent is off. If you’re going to be doing plumbing yourself you should consult with the local inspector before you run any pipe. Depending on your jurisdiction they should allow one free consultation per permit. Also if you need dimensions on the fixtures you’re going to be setting, you can request a submittal page from the manufacturer that should have the recommended dimensions
@VASYL1983 жыл бұрын
Hi ! I don't see ventelation for toilet , only for shower, it's ok?
@christianruvalcaba53323 жыл бұрын
What I don’t understand is when your looking at the plans how do you know where to put your pipes?
@deadstiff64862 жыл бұрын
@@VASYL198 unless that 2” vent picking up the shower is also picking up the toilet. Can’t tell how many feet from toilet In my state it has to be within 8 feet …
@artt92523 жыл бұрын
Excellent job describing this. Ty. Subscribed.
@Kurt63793 жыл бұрын
Great video, built my pole barn/house pre internet days. Used Charlie Wing "Visual Handbook of Building and Remodeling". Different size pipe have different allowed distance to vent. Whole house plumbing under slab. Still works great 26 years later. Your system I'm sure works fine. Glad to see the internet is full of hopeless do it your selfers like myself. Enjoyed the comments.
@Velga-vn7bn4 жыл бұрын
Thank you, very helpful, been looking for this info for a while.
@BevinsBuilds4 жыл бұрын
Your welcome and thank you so much for watching. 😀
@hugoscoaching27113 жыл бұрын
So helpful I’m building my house thank you so much!!
@TheBottomChef2 жыл бұрын
Exactly what I was looking for… I owe you money!
@damedicmt4 жыл бұрын
Not sure if anyone has already made this point…? But you need to stay as closest possible to the quarter-inch fall per foot or rise, as you called it. Any fall that drops faster than a quarter inch per foot you will have liquid separating from solid, and that will create a clog!!!
@BevinsBuilds4 жыл бұрын
Yes and I should have been more clear in the video as when I made the statement I was refering to the shower drain line. But all solid waste lines should stay at 1/4 per foot rise. :)
@halalmeatshophk2 жыл бұрын
i know it is mentioned in code but i do have doubts about it. Why would a more sloped pipe be clog compared to a less sloped pipe? Gravity should also play its role. If the 1/4 per foot rise is really important, then why vertical sewer pipe are not formulated as such?
@MrDW-ei1fe2 жыл бұрын
@@halalmeatshophk the water gets ahead of the turd and the turd slows down and eventually hardens.
@halalmeatshophk2 жыл бұрын
@@MrDW-ei1fe is this an opinion or an established fact? are there any tested made on different slopes of pipes? and does these tests have reports for reference.
@MrDW-ei1fe2 жыл бұрын
@@halalmeatshophk established fact. It’s common place in the plumbing trade to annually run an experiment to insure that gravity is real. 6 months ago at my shop we had the control group put dwv at the proper fall as per code while the experimental group puts it at a greater slope than is recommended. 3 months after we dug up the pipes and cut them open. The ones with greater fall than is required by code had a significant amount of waste build up whereas the ones at proper fall had none.
@southswellsd2 жыл бұрын
Thanks for the great ideas !
@619tbs3 жыл бұрын
I'm subbed. Keep these coming.im building a shoust or pole barn. All the help I can get I'll take
@alejandrovanags4948 Жыл бұрын
Thanks for sharing. Was looking for this information for a while! Good video. Mind the pitch!
@chad3653able3 жыл бұрын
Awesome video very informative.
@keithblue83 жыл бұрын
Depending on state and city ..... some measurements and facts given may vary some....... for example, its ideal to grade trunk line between 1/8" to 1/4" of fall per foot. Any more and your liquids out run your solids leaving them behind which can build up and cause a stoppage. Good video ...... just check local and state regulations and codes.
@adamr16372 жыл бұрын
Not actually proven true.
@ericpierce56743 жыл бұрын
It is insightful and practical. Exactly what I was hoping to find. So easy to follow. No nonsense in between about a cat dog or random useless knowledge. Keeping this video forever. You have an amazing gift for laying out the details so they can be easily understood.
@BevinsBuilds3 жыл бұрын
Thanks I appreciate it.
@benzun96004 жыл бұрын
Excellent help for our project. Thanks
@BevinsBuilds4 жыл бұрын
Yw
@mikeycoleby93914 жыл бұрын
Verrrry helpful!!!!!! and understanding..... great 👍
@BevinsBuilds4 жыл бұрын
I want to add I state a few things wrong in this video. The first is any pipe that has solid waste shoukd never have a pitch greater than 1/4 per foot and the second is that the pipe I referred to as the cleanout will actually be the vent. :)
@user-qe2pf4pb6c8 ай бұрын
Great video, thank you!
@anthonymarafi81602 жыл бұрын
Tanks for sharing the knowledge 🙂🙏
@sabirmoosa3 жыл бұрын
Thank you for sharing since I am doing something on a larger scale and u north where the lines have to be 4 feet underground to prevent freezing. This was a good start. Was wondering if I were to connect 3-4 washrooms and 2-3 sinks how many venting lines would be required. to be installed along the loop.
@MrDaryboy7 ай бұрын
Great explanation. Thanks
@TwistedFilm Жыл бұрын
wow, this video is three years old and today June 9, 2023 I am doing the exact same thing you're doing, and if I did not see this video I would've have done everything wrong. Thank you for the information I can't express how invaluable this video is.
@sonicportal73756 ай бұрын
Everything THIS guy did is wrong though. I really hope you didn’t follow this video’s advice!
@Brough11112 жыл бұрын
Thank you helped a lot!!!!
@wyattthatcher3373 жыл бұрын
Great video
@vegaszen3 жыл бұрын
Thank you!! Great explanation
@BevinsBuilds3 жыл бұрын
Thanks
@christadifaАй бұрын
Thanks man.. useful information.. thank you
@andrey1620009 ай бұрын
Quarter inch rise because you start at the bottom or clean out and go up, not 1/4” fall. The vent on the shower is over pipe diameter for grade, will syphon out probably. And tough to tell in the video, but min 2” wet vent on toilets. Plus toilet is over graded. The poopoo will be sticky sticky on the pipes
@deanberry79784 жыл бұрын
The best video I have seen on plumbing. Lots of Information. Thanks man.
@BevinsBuilds4 жыл бұрын
Thanks for watching. :)
@MrMikeyPayne4 жыл бұрын
Thank you for helpful video. Not sure if anyone mentioned it, but the cleanout looks like it has an elbow to make the 90 degree turn. I think you want a long sweep 90, so a snake can easily make that turn if unclogging in future.
@BevinsBuilds4 жыл бұрын
Thanks Michael, I honestly didnt think of that and your right that would have been a good idea to add. Sadly this video is a year old so its all burried already. 😀
@The85F0X2 жыл бұрын
I'm getting ready to build and I want to do as much as possible on my own to save money, child support is killing me. This was a great video for what I'm planning on building.
@jm395092 жыл бұрын
Same here. No child support but trying to save as much money as possible.
@rockmorales2 жыл бұрын
@@richardmartin2646 Stroke?
@richardmartin26462 жыл бұрын
@@rockmorales sorry
@club-up4 жыл бұрын
As per code you have to have equal going through the roof on venting as you do on the building drain, e.g. 3" out 3" through the roof. Two 2" and one 1/12" minimum. Or one 3" and every other ties in to that based on the fixture unit size.
@BevinsBuilds4 жыл бұрын
The vent is 3 inch but I refered to it as the cleanout and yes it will be ran up and out the roof.
@club-up4 жыл бұрын
@@BevinsBuilds just a thought, good job 😎👍
@andyallen17725 ай бұрын
This is the video showing what you should not do. The slope into main drain from the shower create a S-trap which violate a plumbing code. You should put them on level. Now you need to dig the slab to make it correct.
@danielcroft76984 ай бұрын
Wrong, do not use this layout.
@AnimalFries4 жыл бұрын
I always like when plumbing vids are recommended to me! This was a nice find. I'm seeing a bunch of "too much slope" comments though. This does not apply to plastic piping. Go look inside your pvc/abs piping. Notice it's really smooth and slick. Now wet it. Its gets really slippery, and will not catch anything. Your toilet flushes with a little over a gallon of water. All that water will carry any solids all the way to your city sewer tap or septic tank with proper pitch. Some codes say atleast ⅛" for 3", others say ¼" for 3". Now go look inside cast iron piping. It's not so slick, and actually quite rough on the inside compared with plastic piping. The "too much slope" idea came about with this cast iron piping. Inspectors were worried that with too much slope, water would flow faster than solids, leaving solids behind due to the rough surface of the cast iron. Just something you may consider next time. You're fine with the slope you have. I'm sure you've never had any problems with this rough in.
@BevinsBuilds4 жыл бұрын
Thanks for the comment. As I have also had a lot of extremely rude comments I deleted as well. But this setup did pass inspection and works fine. So I felt maybe a lot of the negative comments were just trolls. 😀 But I do also understand different areas can have different requirements as well. Just all depends on the inspector for that area.
@paulkelley863 жыл бұрын
@@BevinsBuilds honestly it is just how KZfaq is. Miserable people want to go out of there way to somehow one up you by saying you did this and that wrong. I get them too, all day. Still hard to understand what is wrong with those people. I am considering doing my own rough in under slab plumbing so that's why I am here and your video does help. An honest thank you, you did not need to take the time to make and share the video but you did. Tell the haters to make a video of the "right way" they would do it, their nay sayer comments have no value.
@andreguertin6063 Жыл бұрын
Just so you know 1/4 rise is necessary so that some water remains in drain longer to keep paper from sticking to the bottom of pipe if you use 1/2 or worst 3/4 inch the water flows out too fast and leaves the paper behind to build up.
@paulcyr25937 ай бұрын
I did 18" between the centre line of my toilet and the side of my vanity, and it makes it so much when cleaning.
@oOAjjOo2 жыл бұрын
Thank you.
@therag85862 жыл бұрын
Thanks, now if only I could find a video on how to finish the vent
@Flemsas Жыл бұрын
Best Video on rough plumb hands down! Thank you sir this is very much appreciated
@BevinsBuilds Жыл бұрын
Thanks
@topspeederalmond3 жыл бұрын
THANK YOU
@Ana-Junubi2112 жыл бұрын
Thanks very much bro, maybe one day my U tube channel gonna boom
@brettm89702 жыл бұрын
Nice info
@DrMikePosey5 жыл бұрын
This brings back memories! Trust me...in the dead of winter when you’re in the middle of building or a live stream (pun intended!), you’ll be wishing you had a toilet! LOL Are you going to put a sink out there at so you can clean parts and things?
@BevinsBuilds5 жыл бұрын
Lol, yes a winter stream would not be a good thing. I would like to put a full bath in this and a parts cleaning area as well. Thats all going to depend on when and if I am ever able to get a septic field installed. Although from what I have been looking into I dont think it will be to bad at all to do. As they have some smaller holding tank options being this isnt a residence.
@giotambo39754 жыл бұрын
Fix water pipe copper broken
@sebasthiantoyhunterhernand49873 жыл бұрын
can you put the clean up and the vent line outside the slab if you set up the shower and toilet both against the wall ?? TIA
@MarPF Жыл бұрын
Are you using Oatey Medium Clear PVC Cement? How do you find it for working with 2-3" pipes? In case you have also tried the Regular (viscosity) cement, which one do you prefer? I am trying to decide on which one to go with for 2-4" pipes and according to their description both will work fine as Regular can be used up to 4" and Medium up to 6".
@Re5ist_ance4 жыл бұрын
Awesome video .. the one thing i will add (that i got from a plumber once) - is that you don't want to put excessive slope because when you do, the "liquids" tend to leave the "solids" behind. Thought i'd mention that just in case there's any truth to it :) Cheers.
@joshualruby4 жыл бұрын
It's definitely true on toilet lines. (Because they have solids and toilet paper, the greatest culprit). On the smaller line...not typically an issue.
@BevinsBuilds4 жыл бұрын
Yes you dont want to run it on too much of a slope. Sorry I didnt learn that until after I didnthis already. But the plumber friend I have told me that being this is such a short run that the pitch ofnthe line is fine. My finished pitch ended up being roughly 3/8 for 2 ft before the 45.
@josephhoppes3563 жыл бұрын
Nice video! Easy to understand and to watch. Plumbing can be difficult at best for some people tackle. Other than a couple of code violations It should work. Might have a bit of a problem holding trap seals with the changes in height from the trunk line. Hope it all works for you. By the way 3” was a good choice if the septic doesn’t allow for a 4” inlet.
@joeman67302 жыл бұрын
Ina ground up project, what determines if this rough plumbing goes under/within slab or on top of slab?
@yvonnetutanava45733 жыл бұрын
Thanks for the vid. Do yu hav any on setting the shower, toilet n sink all in line against the wall?
@BevinsBuilds3 жыл бұрын
Not as of this time no.
@markhickey56107 ай бұрын
On your bottom treated grade board did you use a 2x10?
@Mr.P-trap3 ай бұрын
instant sub
@chadjohnson3524 Жыл бұрын
Thanks
@Bama74962 жыл бұрын
Your drain and vent going out need to equal the same area per code, minimum drain slope is 1/8" which needs to be engineered. You shouldn't use anymore than 1/4" because your liquid will flow past your solids. That way it will take it all down and not leave solids in your drain line.
@chentevergara28852 жыл бұрын
How's it going boss Now I'm not a licensed plumber but I did a restroom for a client of mine and it turns out his brother-in-law was a master plumber the only thing I got wrong was according to him The 90 from the toilet he wanted me to put a long sweep 90 instead of a short 90 That's all I would change but otherwise it looks good!
@supporterofeverythingyouli62552 жыл бұрын
You can use 90-degree long sweeps
@bretthadley30882 жыл бұрын
The toilet is missing a vent. The shower venting will not work, you broke the plane. If the the 2 inch wye fitting was flat and not on a slant it would work. you do not need a 3 inch cleanout inside of a small cabin or house. The toilet is considered a cleanout since you can remove it. The overall look was good and layout looked straight. 12 1/2 inches from from framing to toilet center is perfect since most people forget about drywall when they say 12".
@mikecarney8023 Жыл бұрын
I believe the code states that vents must connect to a horizontal drain at a minimum 45° angle. Meaning you could not use a tee or a wye to connect a vent to a drain if all pipe connections are coplanar (flat). I think his layout looks good, but if the 2 inch wye were flat, it would be… not good.
@davechapman21952 жыл бұрын
If you use over 1/4 per foot rise the water will flow quicker than the solids. So don't overkill the rise.
@mrwalkyoudown21752 жыл бұрын
Not bad video I would have put my vent in between before the toilet. In Philadelphia you are aloud 1 fixture past the vent
@leslietinyhousebuilderwann38513 жыл бұрын
Thanks for the information. It was really helpful. Where do you live? I live in Texas.
@BevinsBuilds3 жыл бұрын
Your welcome thanks for watching. I live in michigan.
@CW-hq2qr2 жыл бұрын
Can tell a lot of DIY plumbers in here think they know what there talking about 😂 looks good man should work out nice just try to avoid a flat vent. Hard to explain over a KZfaq comment but you can find it on the internet
@BevinsBuilds2 жыл бұрын
Thanks, I actually was in a hurry when I did the video because the concrete was on its way. So I know I didnt describe everything as good as I should have.
@neustif3 жыл бұрын
Toilet should be 12"" to center of pipe, not edge
@dailleztj3 жыл бұрын
13 inch from the unfinished wall to center...
@mikemel9718 Жыл бұрын
I believe it's rise because excavation typically starts at the lowest point so you would be rising to the finish
@jamesrivermd Жыл бұрын
Where can I find the $182, 1,000 gallon holding tank?
@halalmeatshophk2 жыл бұрын
if the main out horizontal pipes are to be sloped at a slight angle, then wouldn't the vertical connecting pipes be also a little slanted and not perpendicular to the ground? what is the technique to install vertical pipes perpendicular to the ground and yet the connecting horizontal pipes be sloped? i do assume here that vertical pipe bonding with horizontal pipe are properly angled at 90 degree to avoid leakage.
@conw5144 Жыл бұрын
Have you ever found an answer to this question? I’ve been wondering the exact same thing and I can not find anything on the internet that addresses this.
@halalmeatshophk Жыл бұрын
@@conw5144 No i didn't find the solution yet. I really wonder how they solve this problem. If you do find any guides or video about it, do share with me.
@conw5144 Жыл бұрын
@@halalmeatshophk I definitely will
@conw5144 Жыл бұрын
@@halalmeatshophk Apparently, the pitch on horizontal drain pipes is not enough to really affect the adjoining vertical pipes. Plus there is a small amount of wiggle room when a pvc pipe is inserted into a hub on a connecting piece. This was told to me by a licensed builder who also has had experience in plumbing. Hope this helps!
@cryptobug75312 жыл бұрын
The vent is not off the main, it's off the branch so that means the toilet is not vented. But it's just a poll barn
@BevinsBuilds2 жыл бұрын
The vent is off the main its what I refer to as the cleanout
@alwynallanКүн бұрын
@@BevinsBuilds I don't think the shower trap is vented either - that 2" wye would have to be horizontal (with 1/4 in/ft slope) to qualify as a "horizontal wet vent" according to UPC, at least. It will probably work, but it's not code.
@Hever734 жыл бұрын
combo fitting or wye wouldn't be better for venting this full bath?
@BevinsBuilds4 жыл бұрын
The actual vent when completed will be where the 3 inch cleanout it located.
@danieljohnson2740 Жыл бұрын
supply lines?
@shenroong4 ай бұрын
is vent up to the code?
@nolantanaka565 Жыл бұрын
I think it might’ve been better to use a long turn 90 on that clean out
@mockcitynl5 жыл бұрын
I would totally put in a toilet. When I am building, I always keep going until I absolutely have to go. I also recommend putting in a sink and counter so you have space to wash Lego or have a coffee maker and stuff.
@BevinsBuilds5 жыл бұрын
I totally agree but its more of a cost issue than anything. As I dont live in the city for me to have a restroom I have to install a septic tank and field. If the tank for my house was closer I could tie into it but its so far away I wouldnt have the correct flow for my drain lines for it to work. But at some point I will have a bathroom in it, just not sure when. :)
@getyourbone Жыл бұрын
Apparently Yer not very old…that’s a hell of a long walk once your digestive system, hips and knees start to go!…some old newspaper, a roll of toilet paper, and a wood stove for disposal works reall well!…so I’ve heard…😊 Thanks for the vid!
@user-ty4km6ef1u3 жыл бұрын
Where do you get the 1000 gallon holding tank for $182.00 ? The price has changed some but where did you find it?
@BevinsBuilds3 жыл бұрын
It is funny I actually just responded to this on another thread. The thousand gallon tank number one I actually missed spoke it was 750 gallons but number to the price tag on that now is considerably higher. This was listed at my local Menards for $182 at the time of purchase and I only paid $182 but it's because they had it mismarked they actually corrected the price the day that I purchased it and now I believe they are between five and six hundred dollars.
@user-ty4km6ef1u3 жыл бұрын
@@BevinsBuilds ok i see ,well thank you so much for replying i do appreciate it greatly,ill have to look for your other channel i like to watxh your videos when i get a chance,again thank you keep up the good work!!!
@alfonsoescoto56113 жыл бұрын
1/4 inch Is good no need for over kill or above and beyond
@annallen58388 ай бұрын
Thats a far walk when you gotta go 😂
@panjangneem2 жыл бұрын
If you install a sand/cement shower or a Schluter shower there is an additional curb you may want. Their dimensions are larger than an acrylic shower base. That would likely be added onto the 30” dimension of the shower. And that would mean your toilet would need to be moved over another 4” or so.
@makitagut24725 жыл бұрын
What about a composting facility? It is quite a walk to your home from my vantage point of view. You know, once you start building even basic needs become 2nd place😄. Will you have a sink? Small kitchen counter? You know for coffee, washing hands or bricks. I would have a small cooler for refreshments. It promises to be quite cozy in the winter.
@BevinsBuilds4 жыл бұрын
Its far but not to terribly far away. From the house im 164 ft :) and yes in the winter I am sure I will desperately want a bathroom lol. I do want a small full bathroom at some point complete with a shower but that will probably be a project that will wait until next year. But the ultimate plan when I can do it is with the shower it will be used as a washing station for lego and then I would also have a toilet and small sink as well. Possibly even a small wet bar/kitchen as well. Just big enough for snacks and maybe some plates and glasses. My priority this year is to get it wired and insulated so I can get back to building lego. Which is going to be a rather large task itself being I will be doing it all solo for the most part.
@makitagut24724 жыл бұрын
Very well planned,@@BevinsBuilds . It does make sense to have all the connections ready. Regarding your electrical. You still have to connect it to your house right. Or are you connecting to the city's line? Thank you.
@makitagut24724 жыл бұрын
Also, how I wish I could volunteer and help. You might get some help from local AFOLs. But it also can take away of your personal experience. At any rate, keep up the amazing job!
@BevinsBuilds4 жыл бұрын
@@makitagut2472 Thanks Makita I appreciate it. If you lived locally I would invite you over :) as for the electrical. I really wanted to have a new service installed but wow the price for new service is pretty expensive. The electrical wasnt to bad (1700) but the natural gas line was outrageous (4200) i still dont understand why it would be such a huge coat difference. As if anything the electrical should have been the most expensive in my opinion.
@makitagut24724 жыл бұрын
Thank you,@@BevinsBuilds! What?! Who would have thought there was such a difference in price. I agree. I would have thought that electrical power is much more expensive. Huge surprise there 😮
@jasonbaker3780 Жыл бұрын
None of that plumbing would be legal in the state of Massachusetts. There's no vent for the toilet. The vent for the shower is choked off by the 45 degree bend. The only legitimate vent in that system is the two in line for the lav. In my state you would also need a full three inch Stack vent, which is not present.
@seanstrickland49703 жыл бұрын
One vent at the beginning? I thought they all had to be vented? Thanks
@alcapirobi29153 жыл бұрын
Vents should be within 5' of fixture, the stack can be used if close enough
@clonify29743 жыл бұрын
Plotting piping and prepping pole barn plumbing. Say that fast.. 😂
@BevinsBuilds3 жыл бұрын
Lol
@christophergould6722 Жыл бұрын
Hey sir , where did you find your holding tank , can’t seem to find any for that price
@BevinsBuilds Жыл бұрын
That price was 4 years ago and it was a scratch dent. With inflation not gonna find it that cheap now anywhere.
@ImYourHucklebery1174 жыл бұрын
The way you have the toilet going up from main line created an strap or improper venting way prohibited
@BevinsBuilds4 жыл бұрын
The main line actually continues past and the 3 inch line will eventually be made into the vent. In the video I just placed a cleanout fitting on it.
@hollythecrossstitchaddict834 жыл бұрын
Do you have to be a qualified plumber to do your own rough in plumbing in Georgia usa?
@BevinsBuilds4 жыл бұрын
I dont live in Georgia so I cant honestly say. But as a home owner you are allowed to pull a permit and do whatever work to your house you want without being licensed. As for general repairs you dont need a permit either.
@hollythecrossstitchaddict834 жыл бұрын
@@BevinsBuilds great! Thank you so much
@BevinsBuilds4 жыл бұрын
Your welcome. 😀
@JLBAZANJR3 жыл бұрын
Do you have a link to the holding tank?
@BevinsBuilds3 жыл бұрын
I got lucky with a scratch and dent, but not even that prices for them over the last year have climbed considerably sadly. But all building supplies have.
@fishenbyfaithoutdoors2589 Жыл бұрын
Enjoyeyed your video. But one thing wrong. The 1/4” rise is so that the water won’t run off and leave the waste. You always need to stay with the 1/4” rise.
@CCNA9112 жыл бұрын
Here in Florida you need a wet vent for your toilet and It cannot be more than 5 feet away from it. please correct me If I'm wrong
@BevinsBuilds2 жыл бұрын
I have no idea on rules for Florida
@randylawing55683 жыл бұрын
Where can I get a 1000 gal. Tank for less than 200 ? Thanks
@BevinsBuilds3 жыл бұрын
Its was a diacounted item at menards, sadly they are no longer that price.
@bullfrog_hollow2 жыл бұрын
Where did u find a 1000 gallon holding take for 180$
@BevinsBuilds2 жыл бұрын
Menards scratch and dent but your not gonna find one that price now.
@Brough11112 жыл бұрын
The problem with going to steep over 1/4 inch per foot is the water will gush out and leave the waste, it needs to float.
@BevinsBuilds2 жыл бұрын
Yes but on a pipe only 2ft long its not a concern.
@willavila90022 жыл бұрын
$182 holding tank of 1,000 gallon. Where did you buy it?
@BevinsBuilds2 жыл бұрын
Scratch and dent at menards. This was 3 years ago though. Prices on everything have skyrocketed
@josephd275 жыл бұрын
Wow your on city sewer way out in the country? I'd put in a small bathroom if I were you
@BevinsBuilds5 жыл бұрын
No i wish I was on sewer. I will have to install a small septic field if I decide to put the plumbing to use. But its cheaper and easier to do the rough plumbing now as opposed to later is why I did it anyway. :)
@josephd275 жыл бұрын
@@BevinsBuilds ok
@SCTL7 Жыл бұрын
You could have ran the drain then use a Wisconsin for vent and catch your shower
@JTTTTx10 ай бұрын
30” showers are sold,but do NOT meet code.
@plowerlife2 жыл бұрын
Curbless shower?. Dont forget to account for curb👍
@ChooChooRooter4 жыл бұрын
Always vent behind your furthest fixture Other than that Don’t listen to these KZfaq plumbers Looks fine
@focalplane30634 жыл бұрын
Furthest fixture from what? Furthest from where the drain comes into the building or?????
@ChooChooRooter4 жыл бұрын
Focalplane He got the clean out and the vent on opposite ends wrong But it will work just fine
@focalplane30634 жыл бұрын
@@ChooChooRooter yeah, I looked at it since my comment and realized the same thing...thanks.
@BevinsBuilds4 жыл бұрын
The clean out will end up being the vent. But this is just roughed in for the concrete to be poured and where the cleanout is placed will eventually be the actual vent and will be extended all the way up through the rough. The system will work though as is though even using the 2 inch line as a vent.