SCHNEIDER Acti 9 THREE PHASE DISTRIBUTION BOARD INSTALLATION

  Рет қаралды 66,891

eFIXX

eFIXX

2 жыл бұрын

We've installed a Schneider Acti 9 isobar P distribution board as part of our industrial unit rewire. We get some top installation tips from electrician Eddie Clemmens.
================================
📍SUBSCRIBE TO THE CHANNEL eFIXX helps electricians, electrical contractors, building services engineers, and electrical apprentices. Watching our videos, you'll discover new products, explore new applications and find answers to your technical questions. So if you've been on the tools for years or just starting your electrical journey, we'll help you stay up to date with the latest regulations and developments in the electrical industry. hub.efixx.co.uk/youtube-subscr... ================================
📺 NEW TO THE EFIXX CHANNEL Watch our essential videos playlist hub.efixx.co.uk/essentials​
📺 CATCH UP ON THE LATEST VIDEOS hub.efixx.co.uk/latest​
📺 ELECTRICIANS' TOOL REVIEW hub.efixx.co.uk/tools​
========================================
eFIXX - EDDY CURRENT MERCH
Now available from an online retailer that doesn't do next day delivery. www.eddycurrent.store/
========================================
🔴 eFIXX LIVE Join us for our youtube live stream twice a month - features product sneak peeks, challenges, giveaways and live electrical banter.
NEXT STREAM HERE 👉hub.efixx.co.uk/next-live-stream​
Catch up on previous episodes 👉hub.efixx.co.uk/livestream​
================================
🆕 FREE CPD Learn about new applications, regulations and best practice with our FREE CPD modules. - New modules released every month covering everything from surge protection to lighting hub.efixx.co.uk/CPD​
================================
📝 APPRENTICE HUB If you're an electrical apprentice, retraining as an electrician or looking to refresh your knowledge, then please check out our apprentice hub. It contains thousands of multiple-choice questions to help prepare for electrical installation exams. hub.efixx.co.uk/apprentice​
================================
📩 eFIXX NEWSLETTER Sign up to find out about our live events, competitions and product giveaways. www.efixx.co.uk/sign-up​
================================
FOLLOW US on your favourite social networks for behind the scenes action, breaking news and competitions.
🟠 INSTAGRAM hub.efixx.co.uk/Instagram​
🔵 LINKEDIN hub.efixx.co.uk/linkedin​
🟣 FACEBOOK hub.efixx.co.uk/facebook​
🟡TWITTER hub.efixx.co.uk/twitter​
==================================
❌ This content on this channel is for electrical professionals.
❌ ==================================
📹 Presented by
Gary Hayers - Editor eFIXX
with
Eddie Clemmens - Pegasus Electrical
===================================
#efixx #electricians

Пікірлер: 74
@Zombie_Longwinger
@Zombie_Longwinger 2 жыл бұрын
You have to give credit where credit is due I’ve been in the Electrical game for over 20yrs and that’s a neat board that guy needs paying in gold bars
@brianwood5220
@brianwood5220 2 жыл бұрын
I would always torque up connections. Lovely job with the board Eddy. You can't beat Schneider gear. Thanks for sharing.
@tombellis186
@tombellis186 2 жыл бұрын
When's the SPD video coming out?
@adambrammeld9286
@adambrammeld9286 Жыл бұрын
These Acti 9 boards are the mutts nuts, very cool little features in the board and generally very nice looking, we’ve been asked to install a few now for this reason 👌👍
@richardpowell181
@richardpowell181 2 жыл бұрын
That's a very good tip for neatening up 3 phase distribution boards. I will use that.
@ianstanley5157
@ianstanley5157 2 жыл бұрын
The new little bosch go (Gen 2) is perfect for this kind of work ... set the torque to make sure you dont over tighten and it makes it quick and easy ... it takes a little getting use but once you get the hang of it .
@electrician247
@electrician247 2 жыл бұрын
Those whia digital drivers are brilliant have some myself. Huge fan. Also great to see Eddie on the channel. Anyone give any grief send them my way as Eddie is a champ!
@efixx
@efixx 2 жыл бұрын
Thanks Mark 🦾💕🦾
@rjb5667
@rjb5667 2 жыл бұрын
Anyone give any grief and send them your way? Cringe 😬
@electrician247
@electrician247 2 жыл бұрын
@@rjb5667 thanks for sharing. Cringe....
@tomorichard
@tomorichard 2 жыл бұрын
@@rjb5667 great input thanks
@darkdepth1991
@darkdepth1991 2 жыл бұрын
Hi mark, they look indeed very beautifull. Maybe I got to order that one for work !
@howsthat5617
@howsthat5617 2 жыл бұрын
Hi Guys, any idea when you will be uploading the stand alone video for the SPD, mentioned on Eddy's Board?
@ianstanley5157
@ianstanley5157 2 жыл бұрын
I find that moving the wire at the bottom from side to side to make sure it is seated properly ... prior to doing the final tensioning of the screw is just as important as the torque ... especially when installing larger gauge wires.
@PHealey1981
@PHealey1981 2 жыл бұрын
Such great kit.
@eastyyx
@eastyyx Жыл бұрын
Great video, did you ever release the standalone video of the SPD connection?
@impactvision
@impactvision Жыл бұрын
The problem with SPDs with TPN boards like these are that the earth bar is at the top, so keeping to the
@sterlingarcher46
@sterlingarcher46 2 жыл бұрын
4 sets of torque screwdrivers , this man is Serious , man don't mess around blud !
@efixx
@efixx 2 жыл бұрын
👍🏻
@callumsimpson7483
@callumsimpson7483 2 жыл бұрын
🤣🤣
@edglue6138
@edglue6138 2 жыл бұрын
Haha
@OneLifeOneShot
@OneLifeOneShot 2 жыл бұрын
Great job. Iam also an electrician. ❤️❤️❤️❤️
@dal1507
@dal1507 Жыл бұрын
Great video, really neat work! When will the video for the SPD be out??
@ianstanley5157
@ianstanley5157 2 жыл бұрын
I noticed he uses the correct bit while using the wiha screwdriver ... but changes to a standard pozi driver while using the torque ? Dont wiha sell the correct bit for the circuit breakers ?
@derrickstableford8152
@derrickstableford8152 2 жыл бұрын
Torque screwdrivers really are an essential piece of sparky kit, esp for industrial work. 80% of faults are down to loose wires.
@yoyoyotooo
@yoyoyotooo Жыл бұрын
Or incompetence, never use a torque and never had a problem
@harryrouts802
@harryrouts802 2 жыл бұрын
I am confused how the neutral is connected to the iso-bars for the double pole breaker for example?
@ianstanley5157
@ianstanley5157 2 жыл бұрын
I noticed on the German machines that I have commissioned ... the sparkies put a red dot on the breaker ... I hear it is to verify that they have torqued the screw ?
@jammyb2008
@jammyb2008 2 жыл бұрын
Interesting video and it just looks like the MCBs are in the wrong way round but they’re not.
@arcadia1701e
@arcadia1701e 2 жыл бұрын
Pretty standard stuff there, decent job. I like that he actually mentions cable grouping inside the board, im sick of seeing bundles of cables tied together so tightly they nearly merge. Loosely spread is the way. Far to many Instagram electricians thinking that pretty means good!!...When in reality ( unless all those cables have been massively upsized ) are making a nice fire hazard.
@hemi4722
@hemi4722 2 жыл бұрын
Thanks for the comment. I've always done it really tight, I don't think in such a large panel the heating would matter. But your comment and the video has made me change my habit.
@timdavison640
@timdavison640 2 жыл бұрын
Plus on the installs cables are mostly stuffed into trunking creating a grouping factor not really any different to the db
@electrician247
@electrician247 2 жыл бұрын
@@timdavison640 spot on trunking is the enemy with grouping especially horizontal runs. Not DBs. Total myth in many cases started by those who sit behind a desk.
@alinili5569
@alinili5569 2 жыл бұрын
Believe me on 3 years old housing development in London I carried out EICR and if I could show you the heat on neutral caused the colour changed where every 5 inches there is cable tie yes looks neat but as you say it is hazard for. Heat dissipation
@tomorichard
@tomorichard 2 жыл бұрын
Unless the circuits in question are run close to max operating temp. I don’t see a problem with grouping inside a dis board
@robertwatt2859
@robertwatt2859 10 ай бұрын
Does anyone know if the stand alone video for the surge install ever came out. I can't seem to find it.
@andrewfenn5287
@andrewfenn5287 2 жыл бұрын
Would have been nice to see boot lace crimps and cable ferries used. Also think be better to slot board and trunking.
@Mladjasmilic
@Mladjasmilic 8 ай бұрын
Why do you put a fuse on Neutral?
@michaeldavies1755
@michaeldavies1755 2 жыл бұрын
Can I ask what the purpose of the double pole MCB is in this installation? I have never installed one and I'm wondering what scenarios would mandate their usage. Thanks
@efixx
@efixx 2 жыл бұрын
That particular breaker is for a test house we are planning to build within our unit. The DP MCB will also serve as an isolator.
@KenhDienDocDaoTranChien71
@KenhDienDocDaoTranChien71 2 жыл бұрын
oh good
@birdie_79
@birdie_79 2 жыл бұрын
Can’t see the M.E.T bolt installed or a main earth ??
@nusermane1076
@nusermane1076 2 жыл бұрын
How does he handle Eddie currents? 😁
@ELECTRICLIFE4U
@ELECTRICLIFE4U Жыл бұрын
👍👍👍👍👍
@kostasfatigas3465
@kostasfatigas3465 2 жыл бұрын
Mechanic interlock must been closed booth when you join tow devices together because they are not join correctly
@user-om2oy4re4d
@user-om2oy4re4d 23 күн бұрын
I have been told cable ties are not allowed inside a board as per the NICEIC inspection? One of our guys had an NICEIC inspector actually make him cut the cable ties on site
@simoncroft9792
@simoncroft9792 2 жыл бұрын
Use releasable cable ties, cost a penny more but easy when adding the inevitable “extras”
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
I don’t see the need for three or four different torque screwdrivers for one DB total cack , why in. God’s name can’t they just have one or two torque settings and one torque screwdriver that covers those settings. My torque screwdriver covers 1Nm to 5.5 Nm so i’am pretty sure I would be covered for that DB . Absolute Madness this is nothing more than the Germans make a bank load of money of the back of the Uk . The world has gone positively gaga I’am telling you. Also I still hear that word required torque , it’s not required it is how ever the manufacturers recommendation nothing more. But tobe fair that is a nicely dressed DB , I have always used cable tie’s when dressing that type of Board but I never took the cables up then fold back down , I like that look a lot neater . Job well done 👍.when it comes to torque settings just dropped the word required. Fantastic video as always Gas 👍👍👍👍❤️
@marcel_ruch
@marcel_ruch 2 жыл бұрын
why not just use a combined mcb/breaker instead of seperated ones?
@acelectricalsecurity
@acelectricalsecurity 2 жыл бұрын
Nothing new really, nice that there's no tails on the rcbo's. Not sure why you need all those torque drivers when the setting cross each other, dread to think how much they cost, I did think they would beep when the level was reached and not click like a standard one with them being digital. Probably controversial bunching them together no matter how tight they are, but it's something I do, and I don't lose any sleep over it.
@howsthat5617
@howsthat5617 2 жыл бұрын
Where is the stand alone video link for the spd? Mentioned at 3.30??
@efixx
@efixx 2 жыл бұрын
Coming soon
@yngndrw.
@yngndrw. Жыл бұрын
@@efixx Are we there yet? :)
@impactvision
@impactvision Жыл бұрын
​@@efixx almost ready? 😂
@johndillon5290
@johndillon5290 3 ай бұрын
Strange that there are no core IDs
@perryhedges2469
@perryhedges2469 2 жыл бұрын
BBG IN A STRANGE ORDER TO ME
@x0MARLOW0x
@x0MARLOW0x 2 жыл бұрын
Bgb?
@michaeldavies1755
@michaeldavies1755 2 жыл бұрын
@@x0MARLOW0x perhaps he means brown grey black
@x0MARLOW0x
@x0MARLOW0x 2 жыл бұрын
@@michaeldavies1755 the three pole with rcd is using l3 - l1 - l2 not l123 6.00 timestamp
@michaeldavies1755
@michaeldavies1755 2 жыл бұрын
@@x0MARLOW0x got ya. Yeah it's got three phases and the conductors are in the right colour phase but how would.you record that on your test results? A three phase device for example would occupy 6L2, 6L3, 7L1, not sure I like that
@sandymcnair5298
@sandymcnair5298 2 жыл бұрын
Discussion - The distribution boards, switches and isolation and the like do not appear to be installed at a height which is maintainable and as such will require steps to perform simple maintenance and switching tasks. The average reach of a person standing on the floor is 2.1m. MOD design and Maintenance Guide 08 which is often used as a reference suggests 2.0 as a maximum height. Unless mitigated by a Designers Risk assessment, all maintenance and switching operations should be undertaken from a maintainable and accessible position, such as floor standing.
@efixx
@efixx 2 жыл бұрын
The board is very long as it’s got a entry box at the bottom with SPD and main switch plus and extension box on top. Under the board is the meter and service head. This is the only realistic option in this installation.
@sandymcnair5298
@sandymcnair5298 2 жыл бұрын
@@efixx it's very difficult to comment on whether this is the only reasonable installation in this case. I do know from the angles presented that the switching parts of this of these DBS is way too high for operation from a floor standing position. I do know from a designer point of view this is something that I see a lot off. I do know from a designer's point of view that often it is not the only reasonable alternative it is usually the most cost effective alternative for the contractor.
@radbot1
@radbot1 2 жыл бұрын
But why?! A single phase RCBO takes one slot, but we need 7 slots for a 3 phase? Why I ask you?! Why not have a 3 module, 3 phase RCBO?! It makes upgrading an older fully populated board impossible without.
@craigjordan5392
@craigjordan5392 6 ай бұрын
And the spd video......
Insane 3 Phase AFDD Distribution Board
23:59
Mike Page
Рет қаралды 21 М.
Қайрат Нұртас & ИРИНА КАЙРАТОВНА - Түн
03:41
RAKHMONOV ENTERTAINMENT
Рет қаралды 511 М.
Nonomen funny video😂😂😂 #magic
00:27
Nonomen ノノメン
Рет қаралды 15 МЛН
APPARENTLY IT'S EASY, CONSUMER UNIT INSTALL. ELECTRICIAN UK
13:12
R Davis Electrical
Рет қаралды 223 М.
Installing my Favorite 3 Phase Distribution Board
27:35
Mike Page
Рет қаралды 57 М.
Terminating a 3 Phase Distribution Board
57:04
Mike Page
Рет қаралды 45 М.
Steel Conduit Bend, Set and Measure AM2s
15:42
Heads Up 4 Sparkies
Рет қаралды 134 М.
Why spend $10.000 on a flashlight when these are $200🗿
0:12
NIGHTOPERATOR
Рет қаралды 16 МЛН
Распаковка айфона под водой!💦(🎥: @saken_kagarov on IG)
0:20
Взрывная История
Рет қаралды 10 МЛН
Infrared Soldering Iron from Cigarette Lighter
0:58
ALABAYCHIC
Рет қаралды 1,9 МЛН