SIEMENS G120 VFD - PROBLEM & SOLUTIONS : TROUBLESHOOTING VIDEO
Пікірлер: 37
@amarnathnsw939211 ай бұрын
Great job
@bishantkumar1258911 ай бұрын
TQ sir 🙏 pl share this channel with your electrical team
@SunilYadav-ed9xt11 ай бұрын
Very nice sir
@bishantkumar1258911 ай бұрын
Thank you. Kindly share this channel with your electrical team 🙏
@shahalijoy83703 ай бұрын
Hello, my sinamics g120 drive BF showing.All over check only cu250s-2pn problem. Maybe ip address change (configaretion ip addrrss) setting given then solve problem. But i don’t understood this setting.pls, help me?
@bishantkumar125893 ай бұрын
Fault number?
@user-fg4cd3ll3j6 ай бұрын
Hello sir please help me. My Siemens Vfd g120c me remote control se reverse Nehi hora he. Me aap se baat karna chahta hun.
@bishantkumar125896 ай бұрын
Reverse movement of motor ??
@kolkurikeerthana49563 ай бұрын
Sir please tell me motor rotation change parameter
@bishantkumar125893 ай бұрын
kzfaq.info/get/bejne/idCUpNmJ0pbNdoU.html
@user_007593 ай бұрын
Sir, most oftenly I faced F1665 & F30665 of my G120C-pn drives. I want to know the reason behind these problems and remedy also. Thanks.
@bishantkumar125893 ай бұрын
F01665 & F30665 - System Is defective - fault. Solution - reboot once. Check ✅ Later. Upgrade the firmware to later version
@user_007593 ай бұрын
@@bishantkumar12589 Thanks sir. But I rebooted,problem not solved. How can I update the firmware? Procedure please? Software Version 4.7 controller CU240E-2.
@SunilYadav-ed9xt11 ай бұрын
Sir dc drive ke full parameters ka details me video banayiye
@bishantkumar1258911 ай бұрын
Ok sir. It will take some time as presently I do not that here
@vinodbankar894211 ай бұрын
New drive ki commissioning kaise krte hai sir starter se??? Basic parameter???
@bishantkumar1258911 ай бұрын
With laptop or with CDP??
@vinodbankar894211 ай бұрын
@@bishantkumar12589 laptop sir... Starter
@cloud_24218 ай бұрын
What is solution in error A30016.
@bishantkumar125896 ай бұрын
Sry for late reply Alarm - Power unit : load supply switched out Solution - check DC link voltage, check AC line supply and voltage
@Fire_palace11 ай бұрын
Sir Auto Tuning par bhi video banayiye with laptop
@bishantkumar1258911 ай бұрын
Okay sir. But we can comfortably do it with CDP
@Fire_palace11 ай бұрын
CDP se aata h mujhe lekin With laptop nhi aata h meri eksha h ki mai apse sikhu Sir
@ArjunKumar-ym6zo11 ай бұрын
sir drive me koi problems ho jata hai to bypass kaise karte hain ?
@bishantkumar1258911 ай бұрын
Alag alag problem pe alag alag part ko bypass karte h. Kya problem face kiya h aapne
@MrutyunjayTelaginamani3 ай бұрын
30021 fault
@bishantkumar125893 ай бұрын
It's a Ground Fault. Check motor and power cable with megger
@infinitevlogs57276 ай бұрын
F08501 fault
@bishantkumar125896 ай бұрын
It's communication board error. I don't have proper idea about that fault sir. Sry
@bishantkumar125896 ай бұрын
Better you change and check ✅
@infinitevlogs57276 ай бұрын
In the line the 24v and 0v got short, so the simens plc gone into error mode and plc was turning on and off again and again so the communication error was showing in the drive. Solved the problem👍
@fansidhumoosewalaka57435 ай бұрын
Sir vfd agr srice pr on ho rha h or drict m trip kr rha h to kya problem hoga
@bishantkumar125895 ай бұрын
Bhai. Itna shortcut samajh nai aa raha hai. Please explain properly
@fansidhumoosewalaka57435 ай бұрын
@@bishantkumar12589 sir agr hm vfd ko 3 phase serice m on kr rhe h to vfd on ho rhi h or agr dirrect 3 phase de rhe h to vfd trip kr rhi h
@fansidhumoosewalaka57435 ай бұрын
@@bishantkumar12589 sir vfd ko agr hm 3 phase serice de rhe h to vfd on ho rhi h or agr dreect 3 phase d rhe h to vfd trip kr rha h