Soft starter|Theory and working principle|How soft starter works|working principle of soft starter

  Рет қаралды 18,771

ELECTRICAL TECHNOLOGY and INDUSTRIAL PRACTICE

ELECTRICAL TECHNOLOGY and INDUSTRIAL PRACTICE

4 жыл бұрын

Soft starter is a scr based starting device which is used to start motor with reduced starting current. the induction motor draws high current during starting. The soft starter intially throws low voltage to the motor, then gradually increases it to full voltage. So the starting current also gradually increases, instead of intial peak.
#ElectricalTechnologyAndIndustrialPractice, #SoftStarter, #InductionMotor
soft starter
how soft starter works
why starter is required to motor
requirement of starter for induction motor
requirement of soft starter
working principle of soft starter
circuit diagram of soft starter
scr based soft starter
fundamental of soft starter
soft starter for induction motor
what is soft starter
motor soft starter
starting method of induction motor by soft starter
soft starting of induction motor
Please like share comment and subscribe

Пікірлер: 29
@ssintx7288
@ssintx7288 9 ай бұрын
Excellent video thank you
@RANBIR970
@RANBIR970 5 ай бұрын
Excellent elaborate Sir. It's very helpful to us as a poor student. No one either our college or faculty gives us this knowledge about this industry related topic. I am your big fan sir.
@RANBIR970
@RANBIR970 5 ай бұрын
And Sir please explain what is Part winding and its principal. If you read my comments, please reply to me so I can assure that you watch me.
@jiyan3146
@jiyan3146 4 жыл бұрын
The best way.. To understanding Thank you sir
@souravbose8115
@souravbose8115 3 жыл бұрын
As always, excellent explanation. Even the basic is rehearsed as well. love it.
@soumenbhattacharjee701
@soumenbhattacharjee701 3 жыл бұрын
That video on Soft Starter was fantastic. Really thank you for that detail technical explanation.
@vineshvinod4603
@vineshvinod4603 4 жыл бұрын
I have seen many in youtube teaching electrical...but no one is good as you...hatss of sir ....continue make videos on more topic in electrical...thanks
@romannevazno5147
@romannevazno5147 2 жыл бұрын
👍
@somasundarpndravid1421
@somasundarpndravid1421 Жыл бұрын
Quite good Explanation.
@arghyanandi6076
@arghyanandi6076 4 жыл бұрын
You cleared all my concert about soft starter
@dtm2448
@dtm2448 4 жыл бұрын
Thank you for making videos on Electrical Technologies. Can you please, make videos on Smart Grid, HMI, SCADA, PLC, IED, DCS and their connection networking. Thank you once again - much appreciated.
@debangshuhaldar8001
@debangshuhaldar8001 2 жыл бұрын
Awesome sir 😍👍
@Invisible_Tri
@Invisible_Tri 3 жыл бұрын
Nice and unique video
@shantanumajhi5408
@shantanumajhi5408 2 жыл бұрын
Very useful 🙏
@Doti_231
@Doti_231 2 жыл бұрын
thank you for sharing sir
@keyurgajjar
@keyurgajjar 4 жыл бұрын
Thanx making this video
@nicolaspillot5789
@nicolaspillot5789 Жыл бұрын
Are the firing of the SCR synchronous cross all phases, or each is fired at N% for each phase ?
@bharathi6898
@bharathi6898 2 жыл бұрын
SCR connection only made in two phases out of three.. I think u missed that topic... Mentioned in soft starter manual sir...
@krishnaRajput-mf4dq
@krishnaRajput-mf4dq 2 жыл бұрын
sir please make a vedio for 12 pulse rectifier
@keyurgajjar
@keyurgajjar 4 жыл бұрын
Can you please make an video about motor protection, say how to do relay setting of ip>, ip>>, unbalancs load etc..
@somasundarpndravid1421
@somasundarpndravid1421 Жыл бұрын
We have observed voltage across motor terminals in Y phase, ln off condition. What could be the reason?
@techyintelo9556
@techyintelo9556 4 жыл бұрын
Is there a math model (mathematical formula) of a soft starter ?
@SanjivKumar-vs1cl
@SanjivKumar-vs1cl 2 жыл бұрын
What is reason behind FCMA Bypass Tripping??
@suryakumars6358
@suryakumars6358 2 жыл бұрын
Sir how to gradually increase the firing angle from zero to max(180 degree).. Because it is completely opposite to three phase ac voltage control where the firing angle set for each SCRs are remains unchanged until the last operation!
@vipulprajapati1580
@vipulprajapati1580 Жыл бұрын
I make final year project in soft starter
@shekharharsha1540
@shekharharsha1540 2 жыл бұрын
S/S once started give rise high Amp in a very short period and get shut. What could be the problem?
@electricaltechnologyandind5335
@electricaltechnologyandind5335 2 жыл бұрын
Check the settings. It should not if properly set
@ravijha2122
@ravijha2122 3 жыл бұрын
Sir current won't be 0 at Ns right?
@shrutimukherjee8378
@shrutimukherjee8378 2 жыл бұрын
Low volume
Setting of soft starter|Soft starter setting calculation|How to determine soft starter settings
17:41
ELECTRICAL TECHNOLOGY and INDUSTRIAL PRACTICE
Рет қаралды 20 М.
VFD and Soft Starter Difference । Electrical Interview Question
9:27
Electrical Dost
Рет қаралды 142 М.
Мы никогда не были так напуганы!
00:15
Аришнев
Рет қаралды 4,9 МЛН
Alat Seru Penolong untuk Mimpi Indah Bayi!
00:31
Let's GLOW! Indonesian
Рет қаралды 13 МЛН
NERF WAR HEAVY: Drone Battle!
00:30
MacDannyGun
Рет қаралды 38 МЛН
What is the Difference between VFD and Soft Starter?
7:30
RealPars
Рет қаралды 2,4 МЛН
Induction Motor Protection& Characteristics|Induction Motor Characteristics|Protection
25:42
ELECTRICAL TECHNOLOGY and INDUSTRIAL PRACTICE
Рет қаралды 20 М.
Soft Starters (Full Lecture)
22:42
Jim Pytel
Рет қаралды 67 М.
How to make a Softstarter and why it is sometimes mandatory to use!
10:31
simple soft start circuit DIY
8:31
Lari Fari
Рет қаралды 43 М.
Impedance Explained.
22:35
PKAE Electronics
Рет қаралды 114 М.
Wiring a Schneider Softstarter for a Motor
18:40
Joel Teaches Electrical
Рет қаралды 53 М.
Seebeck & Peltier Effect - How Thermocouples & Peltier Cells work?
14:22
YOTAPHONE 2 - СПУСТЯ 10 ЛЕТ
15:13
ЗЕ МАККЕРС
Рет қаралды 154 М.
Choose a phone for your mom
0:20
ChooseGift
Рет қаралды 1,9 МЛН