Split System Not Cooling Having Multiple Issues | HVAC

  Рет қаралды 1,908

AB HVAC

AB HVAC

15 күн бұрын

I'm running on fumes on this last service call. I always forget how this time of year can get with these attics, but you gotta try and keep your composure and stay on point either your diagnosis. HAVE A GREAT 4TH OF JULY EVERYONE!!!!!
#airconditioning #hvac #bluecollar #airconditioner #servicetechnician #hvacmaintenance #hvacrepair #techlife #hvaclife #fieldpiece

Пікірлер: 68
@jkmarshall3553
@jkmarshall3553 12 күн бұрын
For hard work like that, I'll take cold any day over that heat!
@myHVAClife
@myHVAClife 13 күн бұрын
That is actually a pretty nice attic for a low pitch roof. I have been in some that you have to belly crawl and lay in front of. Low pitch attics are hot because you are right against the roof. Not uncommon to find larger size air handlers than the outdoor unit in the south especially goodman, helps meet seer rating and dehumidification. Just ask your local goodman rep.
@AB_HVAC
@AB_HVAC 13 күн бұрын
I'm so not used to seeing the mismatched tonnage. My tech school up north taught me to only ever undersize the evap coil by like a half ton for better dehumidification. I've been in worse attics down here but none at this time of day.
@AaronPowellvox
@AaronPowellvox 13 күн бұрын
@@AB_HVAC @myHVAClife is right. For some reason they do that a lot with Goodman. Sometimes it’s like that from the factory, you’ll call and ask for a 2 ton system and you’ll get a 2 ton outdoor with a 3 ton evaporator.
@AB_HVAC
@AB_HVAC 13 күн бұрын
@AaronPowellvox that's so dang confusing
@joeshearer1247
@joeshearer1247 13 күн бұрын
Your eyes must be getting tired that’s not a Goodman air handler.
@MetalDetectingwithCZkidd
@MetalDetectingwithCZkidd 13 күн бұрын
S FL famous for belly crawling.
@Devsfan70
@Devsfan70 12 күн бұрын
People in other parts of the country just don't understand how hot the South gets. I've lived in Georgia my whole life and still hate the summer. Good AC is a must. 🥵
@AB_HVAC
@AB_HVAC 12 күн бұрын
I been here for 5yrs and it's getting hotter and hotter every summer it feels
@Devsfan70
@Devsfan70 12 күн бұрын
@AB_HVAC you're probably right. The older I get, the less tolerance I have for it. I just try and limit going out to do anything in the early part of the day. Yeah it's still hot and muggy but it's not a peak heat.
@AB_HVAC
@AB_HVAC 12 күн бұрын
@@Devsfan70 yeah. I had to swap a gas valve in a low pitch attic on Tuesday for a home up for sale
@justwork_hvac
@justwork_hvac 13 күн бұрын
Cool video, brother. Be safe in those attics they are rough around this time.. i just used that leak seal the other day..
@AB_HVAC
@AB_HVAC 12 күн бұрын
I'm a fan of it, it works either way honestly. Shows you where the leak can be if it can't seal it
@patrickbell4687
@patrickbell4687 12 күн бұрын
I can see in the video it has has to be hot as he'll in that attic. Make sure sure you stay hydrated during the day, especially in the summer. Stay healthy!!!
@jph77
@jph77 12 күн бұрын
I'm from the south and have a walk in attic from the upstairs bonus room.
@AB_HVAC
@AB_HVAC 12 күн бұрын
I love those kinds of attics. Better have that OSHA approved platform 😅
@redneckways1617
@redneckways1617 13 күн бұрын
#8 isn’t big enough for 10 kw heat strips and the blower…needs at least a #6 or unhook half of the strips which you can’t do cause that’s the only source of heat…your only option is to replace the wire with a #6 then run it off of a 50 amp breaker…still has a leak somewhere…that’s the best design for a rental property cause it’s the most reliable but personally I would opt for the inverter heat pump…runs a considerably less amp draw for the same load….
@MoonRambo702
@MoonRambo702 12 күн бұрын
I’d use that same ladder just the shorter one, versatile. I feel u on the basements tho, I was spoiled in Michigan, now I’m in Vegas with these hot ass attics and nobody has a pull down. Ladder needed for every job.
@AB_HVAC
@AB_HVAC 12 күн бұрын
Man, we used to just walk down a flight of stairs, move some totes around and boom got room to work 😅
@MoonRambo702
@MoonRambo702 10 күн бұрын
@@AB_HVAC miss those days, but don’t miss the cold and cheap landlords of Detroit.
@AB_HVAC
@AB_HVAC 10 күн бұрын
@MoonRambo702 🤣🤣 man me and my old bosses had to do some townhouses over off Woodward in highland park. My old boss called me up (owning and working at a new company now) said all the furnaces and condensers were stollen.
@MoonRambo702
@MoonRambo702 10 күн бұрын
@@AB_HVAC 😂 always the neighbors. It’s a huge problem. bro they watch y’all put em in and call the boys the min y’all drive off. It happened a few times to me on the east side. The mgt co. I was working with started having me take the tanks, furnace and ac units to storage, and put em back the day ppl move in. And they have like 3 sitters that are homeless and move em around to nicer vacant properties. They clean and keep up the house too while it’s waiting for a tenant.
@AB_HVAC
@AB_HVAC 10 күн бұрын
@MoonRambo702 🤣 I still remember putting in those units like it was yesterday. Lots of ductwork and pvc being rand for those 90% 'ers
@MetalDetectingwithCZkidd
@MetalDetectingwithCZkidd 13 күн бұрын
Good find on the wire. I would cut the KW in half if the wire size was not sufficient. Then tell the customer to get an electrician out there to change the wire. Most of them were reminded when it got cool out and the house was not heating properly. Disconnect did its job, sort of. To small wire = fire. 10KW at 240v and 8KW at 208v I think is how it works, however, wire a #6, always for anything with 10KW, breaker and fuse size very important as well. I know the heat in attics, S FL was a roaster up in there. The AC was a mix. Carrier AHU with a Goodman Condenser. Zombie AC. If in doubt on the size of the Evap coil, pop the panel and see if there is a manuf tag on it. Usually its there. Nice vid. Enjoyed.
@chrisscott1547
@chrisscott1547 12 күн бұрын
In my experience, leak sealers can work OK on slow leaks (makes them slower) but if refrigerant is gone, you'll get a callback. Oversized evaporators can work OK, but may want to reduce blower speed. Attic work this time of year earns a surcharge...
@joshmason1725
@joshmason1725 11 күн бұрын
I use a little giant king kombo , its light, and unfolds from a 6ft to a 10 ft, they have many sizes...so I recommend a cordless m12 Milwaukee fan .
@ccthepope
@ccthepope 13 күн бұрын
Have a great 4th!
@AB_HVAC
@AB_HVAC 13 күн бұрын
@@ccthepope You too!!!
@isaiahramsey4043
@isaiahramsey4043 11 күн бұрын
Looks like the classic loose lug on the disconnect. Although the wire size is cutting it close.
@AB_HVAC
@AB_HVAC 11 күн бұрын
After stripping it back I was leaning towards the incoming power being 6gauge while the whip was 8gauge but I'll wait till it gets approved to dive deeper into it
@techfive7202
@techfive7202 9 күн бұрын
In Florida I call that a really nice attic
@AB_HVAC
@AB_HVAC 9 күн бұрын
130° or the size 😅? I just didn't like the way the access hole was.
@jrsmyth9761
@jrsmyth9761 13 күн бұрын
per the install instruction, minimum wire size for single feed is 6AWG. minimum 60 amp breaker/fuse. max wire length 80'. leak seal should be a last resort and ALWAYS mark the unit, in multiple places, that you put that crap in. I, for one, will not connect to a unit that has that crap in it!!! I will buy a set of gauges and hoses that is charged to the customer if I run across a unit with leak seal, UV dye or similar product.
@danielzertuche9893
@danielzertuche9893 12 күн бұрын
Your HEATH is more important and your safe too first thing in the morning.
@Dmcbigboy8687
@Dmcbigboy8687 12 күн бұрын
8 gauge wire is good for 40amps and 6 gauge is good for 60amps. I think the 8 should be ok for 10kw heater but would like 6 gauge to be much more safe.
@myHVAClife
@myHVAClife 13 күн бұрын
Can't pull a vacuum on a unit with a leak, will suck in humidity through the hole. Can't add sealant because it will react to that moisture and create restriction. Need to fix the leak and with a goodman it is probably the evap coil.
@AB_HVAC
@AB_HVAC 13 күн бұрын
It's not a Goodman match indoor but I can try and use a lil 410a vapor and then pressurize more with nitrogen to find the leak with my fieldpiece leak detector
@tphvac87
@tphvac87 4 күн бұрын
410A is garbage wish the EPA just stuck with R-22 now we got this new higher pressure trash R-32 and R-454B they just keep screwing us over, mildly flammable gas that runs at same pressure as 410A. Wild stuff man! Let’s replace a TRUE refrigerant with something that runs at double the pressure and leaks a lot faster than 22. Idk what they’re thinking? Lemme know what y’all think?
@AB_HVAC
@AB_HVAC 4 күн бұрын
I wasn't around enough with R22 systems to truly be able to compare the two. But I do find a lot more customers say they were happier with their R22 equipment than R410a
@HAWKTUAIT2024
@HAWKTUAIT2024 13 күн бұрын
Home depot has 6fters for about 60 bucks
@HAWKTUAIT2024
@HAWKTUAIT2024 13 күн бұрын
Holiday? I'm working the 4th the 5th and the 6th
@Mo4Honesty
@Mo4Honesty 12 күн бұрын
What about the 7th and 8th?
@BallSnack5.56
@BallSnack5.56 13 күн бұрын
I've never heard of the right hand rule??? Only rule i followed when taking out disconnects was to make sure i was not leaning on the unit or touching anything with my other hand.
@AB_HVAC
@AB_HVAC 12 күн бұрын
Right hand so if somethings not wired properly the voltage won't go through your heart just the right side of your body down to ground...I think
@BallSnack5.56
@BallSnack5.56 12 күн бұрын
@@AB_HVAC Well that makes sense, i'll have to try to make it a habit of using only my right hand then, the more you know haha
@AB_HVAC
@AB_HVAC 12 күн бұрын
@BallSnack5.56 I said the same thing when someone in the comments mentioned it to me
@coastalcarolinarocks
@coastalcarolinarocks 13 күн бұрын
8 gauge wire can hold like 50 amps max I think
@AB_HVAC
@AB_HVAC 13 күн бұрын
@@coastalcarolinarocks yeah I think that 10k around 60. The incoming wire had to be 6 gauge. Was a pain to strip back and had thicker strands of wire than that 8 gauge had
@drewtab18
@drewtab18 13 күн бұрын
You said you were up north where did you use to live
@AB_HVAC
@AB_HVAC 13 күн бұрын
Michigan. Metro Detroit area
@jkmarshall3553
@jkmarshall3553 12 күн бұрын
Attic air handlers should be illegal anywhere south of Ohio. LOL
@gund89123
@gund89123 11 күн бұрын
I have air handler in garage. I am upgrading my home. My HVAC contractor was suggesting that we should move the air handler to attic, I said no. I live in San Jose, CA. It gets hot here in the summer.
@AB_HVAC
@AB_HVAC 11 күн бұрын
How can we make this federal law 🤣
@AB_HVAC
@AB_HVAC 11 күн бұрын
@gund89123 maaaaaan keep that thing in the garage 🤣 any service tech (and probably future installers) will love you for it. Just make sure it's sealed tight so that way if you use your auto start it's not sucking up exhaust fumes into the air stream. I heard that's a major reason why they try to move them from the garage
@deshevldmusic
@deshevldmusic 13 күн бұрын
I would carry a 12 and a 6 ft ladder then
@AB_HVAC
@AB_HVAC 13 күн бұрын
Just a basic lil fiberglass 6ft or should I look for an aluminum one
@deshevldmusic
@deshevldmusic 13 күн бұрын
@@AB_HVAC fiberglass is OSHA approved. I run a Werner 4footer but I'm 6ft 1.... Get a 6 footer and whatever your highest customer height requirement is. It'll sit on your rack most of the year but you'll be happy with a nice light one until you need to wrestle the big fucker
@AB_HVAC
@AB_HVAC 13 күн бұрын
@@deshevldmusic bet, gonna start looking on the home depot app now
@osvaldomcs1213
@osvaldomcs1213 13 күн бұрын
I went in white. Know I'm dark brown. 🎉🎉🎉😂😂😂😂😂😂
@osvaldomcs1213
@osvaldomcs1213 13 күн бұрын
Harbor freight those expandable ones.
@osvaldomcs1213
@osvaldomcs1213 13 күн бұрын
California attic today. 146 in attic. 😂😂😂
@AB_HVAC
@AB_HVAC 13 күн бұрын
WHAT?! Was it fairly small?
@osvaldomcs1213
@osvaldomcs1213 13 күн бұрын
@@AB_HVAC lol kinda
@AB_HVAC
@AB_HVAC 13 күн бұрын
@osvaldomcs1213 bruh, I swear I sweat off so much weight this time of year
No A/C Service Call That I Will Not Forget | HVAC
18:58
AB HVAC
Рет қаралды 3,2 М.
Home Maintaining 80° During Heat Wave | HVAC
22:14
AB HVAC
Рет қаралды 3 М.
تجربة أغرب توصيلة شحن ضد القطع تماما
00:56
صدام العزي
Рет қаралды 53 МЛН
ТАМАЕВ УНИЧТОЖИЛ CLS ВЕНГАЛБИ! Конфликт с Ахмедом?!
25:37
No A/C, Attempting to Repair Hacked System | HVAC
22:21
AB HVAC
Рет қаралды 1,5 М.
Hacked Systems With Terrible Duct Design | HVAC
20:51
AB HVAC
Рет қаралды 854
I tried to install my own heating and cooling system Pt. #2
26:04
Great Scott Homes
Рет қаралды 3,9 М.
No Cooling - Very Low Suction !
22:29
HVAC GUY
Рет қаралды 33 М.
HVAC.  RIDE ALONG FOR 3 NO AC SERVICE CALLS
22:18
HVAC OTJ
Рет қаралды 9 М.
There just ain’t NO WAY | HVAC |  Amana heat pump low on refrigerant
20:10
Koolin’ with Krauss HVAC
Рет қаралды 6 М.
Mix And Matched Equipment Not Cooling Properly | HVAC
14:49
AB HVAC
Рет қаралды 2,5 М.
The Toughest Central AC Units I Have Ever Seen
8:40
HVAC Shop Talk
Рет қаралды 3,1 М.