Testing Water Heater Spillage: Backdrafting Combustion Fumes from Natural Draft DHW

  Рет қаралды 24,808

Home Performance

Home Performance

Күн бұрын

Пікірлер: 41
@billcunninghame8554
@billcunninghame8554 3 жыл бұрын
Another easy way to determine if there's an ongoing backdrafting issue is to look for rusting around the flue or any melting of plastic components on top of the WH.
@billcunninghame8554
@billcunninghame8554 3 жыл бұрын
@@publicmail2So true...
@sudipadhikari926
@sudipadhikari926 Жыл бұрын
Can I get info on the smoke pencil you are using in the video?
@blueman5924
@blueman5924 Жыл бұрын
Won’t exhaust fans, such as bathrooms and the range hood, change the air pressure dynamics of the house and possibly the gas venting ?
@jaimedpcaus1
@jaimedpcaus1 6 ай бұрын
I wonder, in this case he opened the door to change that air pressure. Do ppl have to create a permanent door to stay open to fix the issue?
@HomePerformance
@HomePerformance 6 ай бұрын
Get a louvered door and you're all set
@sedtronlynn5699
@sedtronlynn5699 13 күн бұрын
What door you open
@mts7274
@mts7274 Жыл бұрын
What about when newer, efficient water heaters just short cycle, and there is just too much cooler air along the entire run of of the flue venting? There is just not enough time for the water heater exhaust to warm that air and create a proper updraft.
@HomePerformance
@HomePerformance Жыл бұрын
Interesting idea, but I'll add that flue diameters should be sized according to need. Manufacturer hopefully has recommendations.
@Foche_T._Schitt
@Foche_T._Schitt 3 жыл бұрын
The pipe should be 12 inches in length before the elbow. If they have a 200 amp service they should just switch to a tankless electric water heater.
@WreckingCr3W2
@WreckingCr3W2 2 жыл бұрын
Do you know the code number in NFPA?
@Foche_T._Schitt
@Foche_T._Schitt 2 жыл бұрын
@@WreckingCr3W2 It's a defacto code. You must comply with the heater's manufacturer's installation instruction which require a 12" rise. If not then I would question it if it was an off brand.
@MosesIvlerMiracleBabyVlog
@MosesIvlerMiracleBabyVlog 7 ай бұрын
What if exhaust from the kitchen stove is on is there any backdraft will happen?
@nyrider8396
@nyrider8396 7 ай бұрын
If you have carbon monoxide detector, will backdraft set it off?
@HomePerformance
@HomePerformance 7 ай бұрын
It better- that’s why you have it! Wear it at your neck level, not down by the belt just in case.
@sunnyd6019
@sunnyd6019 Жыл бұрын
I would cut a high low grille into the room or leave door open.
@spotlightinspect5540
@spotlightinspect5540 5 ай бұрын
Does anyone know the brand of this smoke gun?
@HomePerformance
@HomePerformance 5 ай бұрын
This one is the Dragon Puffer, I prefer the Cirrus Wind Indicator
@marvingarcia8982
@marvingarcia8982 Жыл бұрын
True...whats the smoke tool called..very nice tool
@HomePerformance
@HomePerformance Жыл бұрын
That is called a dragon puffer, but I prefer the Cirrus Wind Indicator
@sunnyd6019
@sunnyd6019 Жыл бұрын
They are smoke pencils. I snagged one off Amazon for 30 bucks, fantastic tool to have. I was checking for duct leaks and draft issues and its a tool you should own.
@leathercheerio1
@leathercheerio1 Жыл бұрын
Just get a vape
@jaimedpcaus1
@jaimedpcaus1 10 ай бұрын
​@sunnyd6019 Thanks Sunny. I just saw it on Amazon.😊
@jimmyphilip2340
@jimmyphilip2340 3 жыл бұрын
What is the best solution? Keep your water heater in an open space ? Or keep your mechanical room open ?
@johnwhite2576
@johnwhite2576 3 жыл бұрын
no combustion within the house ! all electric !
@patrickcowan8701
@patrickcowan8701 3 жыл бұрын
Old mechanical rooms used to have a vent grate in the door, probably not allowed now for fire code.
@HomePerformance
@HomePerformance 3 жыл бұрын
Now they put the vent to the outdoors, which is crazy making for home performance
@sepertude
@sepertude 3 жыл бұрын
You can get a fan that mounts at the top of the water heater that pools air out..
@HomePerformance
@HomePerformance 3 жыл бұрын
Noooooo @sepertude, this is a negative draft system. Please don’t put any fans on it.
@fixitchuck4808
@fixitchuck4808 2 жыл бұрын
This video is junk. If building code and fuel gas code are followed this doesn’t happen A. Opening the door is doing what the hack who constructed the room failed to do. Supply adequate combustion make up air. Hire professionals. B. If you’re producing “toxic gasses” aka CO over 100 ppm, then there’s burner problem. Hire professionals. C. NFGC allows 5 minutes for the chimney to prime before measuring draft. Hire professionals.
@HomePerformance
@HomePerformance 2 жыл бұрын
Haha Chuck I don’t think you have any idea what a ‘professional’ is really trained and equipped to do in US homes these days.
@HomePerformance
@HomePerformance 2 жыл бұрын
Also, you completely overestimate the ability of prescriptive codes to predict and prevent dynamic changes in homes. That’s why performance testing exists.
@fixitchuck4808
@fixitchuck4808 2 жыл бұрын
@@HomePerformance good luck with that, goof.
@fixitchuck4808
@fixitchuck4808 2 жыл бұрын
The “prescriptive code” you’re dismissing requires 50 cf of volume for each 1000btuh of input. In lieu of that, generally 2 sq. in. of free air ventilation is required per 1000btu. I’ve been doing this stuff for 30 years.
@HomePerformance
@HomePerformance 2 жыл бұрын
Good luck to all of us I guess
Water heater draft testing
7:23
Structure Tech Home Inspections
Рет қаралды 36 М.
Backdrafting Water Heater - SIGNS and CAUSES
4:28
Rigid Inspections, LLC
Рет қаралды 9 М.
SPILLED CHOCKY MILK PRANK ON BROTHER 😂 #shorts
00:12
Savage Vlogs
Рет қаралды 47 МЛН
👨‍🔧📐
00:43
Kan Andrey
Рет қаралды 10 МЛН
طردت النملة من المنزل😡 ماذا فعل؟🥲
00:25
Cool Tool SHORTS Arabic
Рет қаралды 11 МЛН
What is Air Lock?
9:46
Practical Engineering
Рет қаралды 5 МЛН
30 Minute Secret Makes Your Water Heater Last Decades
13:03
LRN2DIY
Рет қаралды 2,1 МЛН
How to Tell If There’s a Gas Leak Inside Your Home
1:51
Inside Edition
Рет қаралды 164 М.
The Genius Of Hot Water Heat Pumps
11:39
Undecided with Matt Ferrell
Рет қаралды 664 М.
Is Your Water Heater Backdrafting?
4:55
Wilder Home Inspections
Рет қаралды 26 М.
How This New Heat Pump is Genius
18:03
Undecided with Matt Ferrell
Рет қаралды 855 М.
Improper venting of water heater
2:53
Compass Heating and Air Conditioning Inc.
Рет қаралды 74 М.
SPILLED CHOCKY MILK PRANK ON BROTHER 😂 #shorts
00:12
Savage Vlogs
Рет қаралды 47 МЛН