Honda EU6500is No Start - Carburetor - No Start, Old Fuel Left In Machine. Taking you through a basic carburetor disassembly and cleaning. Quick small engine repair tips.
Пікірлер: 46
@texaslawdawg19024 жыл бұрын
Crystal clear audio and video. I wish others would follow suit. Amazing what you can learn from someone who puts in the extra effort to actually make an informative video
@MrRaffaro5 жыл бұрын
REAL MECHANIC YOU CAN TELL BY HIS HANDS!
@VoltageDropDiagnostics3 жыл бұрын
This video must have been before I knew you! This was a heck of a video, Chris!
@jefflambert75133 жыл бұрын
Excellent video, thank you for taking the time to make this...very much appreciated. Thank You !!!
@immortalengines16055 жыл бұрын
excellent video!
@chrisa90533 жыл бұрын
Thanks for taking the time to make this video. You saved me a bunch of money and having to haul this beast down to the shop again. Now I also know how to drain the fuel when storing this thing so hopefully I don't have such frequent problems keeping it running.
@tristanschaper2814 жыл бұрын
Excellent video, well done!
@howardcrow3 жыл бұрын
super clear video and explanation
@TrailblazinRZRs4 жыл бұрын
thank for the video, do you know if there is a kit for the two o-ring the big one and the smaller one thank you let me know
@JorgeGarcia-hf7jb3 жыл бұрын
You need to change SCREEN SET, FUEL STRAINER and the lane gas to the carburator have another small filter on the pipe.
@jsavoy13 жыл бұрын
Help please! Trying to get generator running before hurricane comes. Got the carburetor off and cleaned. But what is the secret to getting those 2 springs back in place?
@Gummy19914 жыл бұрын
so i am running one of these generators and one day i just couldn't get the engine to run... i can hear it cranking... it wasn't the battery or anything. My uncle told me to add a couple drops of gasoline fuel inside the spark plug hole (the little insert where you screw the spark plug inplace) When I added some couple of drops into the spark plug hole and started the generator after... voila the engine starts... but i gotta do this every time i need to start the engine. Is there a way you could explain why that works? or what is wrong with my generator? I have the same exact model as well.
@cornholius Жыл бұрын
I have a Honda 7000is. Was over 5k and has 200 hours on it. Maintained meticulously and always treated right. Imonitor displays with main switch on. It cranks but won't start. Error codes:e-2e, e-22, and e-12 are all related to inverter protection. I don't know if that's just in reference to times when the generator tripped from too much draw or if it's related to my issue. Everything looks new as far as fuel pump and fuel filter goes. It's fuel injected vs carborated, and my gut tells me that is the likely issue if fuel gummed up in the ports. Have you dealt with this?
@iancairncross50764 жыл бұрын
Have cleaned the carb but the engine still cuts out and loges a eo4 fault coad is ther ant electrical test I can do to find the fauilt am a diesel mechanic and small engine repairer but are unable to find any test proseders
@sfyie2 жыл бұрын
can i use wd-40 on a rusty crankcase(fuel tank) of my Honda generator. Please reply🙄
@michaelmartinez3944 Жыл бұрын
Good video but it would have been nice to see how you put together the top part with the little springs underneath the choke and idle electronics. That is a vital part of finishing the job.
@edwardanstett22975 жыл бұрын
Thank you sir! Where is the best place to buy replacement carb just in case I mess up?
@ScienceOfDiagnostics5 жыл бұрын
Depends on the manufacturer of the generator. Aftermarket carbs can be found all over but I have had some issues with them. I prefer OEM, you can purchase that from whoever is a dealer for that brand.
@seangething45074 жыл бұрын
I didnt watch any video of the carb removal and made the mistake of leaving the wiring on and separating the auto choke and throttle motors from the top of the carb. There are 2 tiny springs that of course fell off and I have no idea of how to realign the motors to hook back up with the throttle and and choke. Any ideas?
@luzyalfredoforever3 жыл бұрын
You got the solution for this?.
@dj57523 жыл бұрын
Thank You for the video. Great Information. Question: A friend of mine has the same generator. I must admit I have never seen this generator up close before. The problem I noticed with his generator is when idling with the Eco off it reads approx 3300 rpm. No problem. When I put the Eco on with no load it does not reduce speed at all, it remains at 3300 rpm's. I believe it should reduce to around 2400 rpm's. When I put on 500 watt work light then put on the eco It lowered to 3180 rpm's Shut off the Eco and it goes back to 3300. Shouldn't the rpm's with no load reduce to approx 2400 rpm's? Have you ever had to research problems with the Eco? Any Ideas would be helpful. Thank You.
@TOURMANBOB2 жыл бұрын
You are correct; it sounds like there is some sort of problem with the ECO switching on your generator.
@dj57522 жыл бұрын
@@TOURMANBOB it turns out the idle was set to high. Once I set the idle to normal specs the eco worked as it should.
@TOURMANBOB2 жыл бұрын
@@dj5752 Good ! Its great when problems are simple
@bloodborne62 жыл бұрын
Why does my generator of the same exact model (6500) only start with a pull but not the key switch? I checked fuses, and battery connections. Thanks
@EdibleArrangementsGrandP-xw2rv6 ай бұрын
great question i hope someone can answer
@jeremyanthony93005 жыл бұрын
what kind of chemical did you have in that ultra sonic cleaner?
@ScienceOfDiagnostics5 жыл бұрын
Jeremy , I'm just using distilled water and dawn dish detergent. Works like a charm for most usages.
@seymourscagnetti14133 жыл бұрын
WATER IN FUEL: STEP 1) BEAT THE SHIT OUT OF CUSTOMER. JOB DONE.
@ztiling56465 жыл бұрын
Hi dear; I have a Honda generator model EU03000is;I didn't have used it for more than 4 year,two days ago I checked up ,it wase difficult to start, I cleaned up carburettor,air cleaner,all of the petrol hosts,and replaced the spark plug with new one, but still have that problem, whe the generator starts ofter ten seconds automatically becomes off,and also during the ten seconds running the machine, generator having quakes and smoke comes out from the sensor,what's the fault with it.could guide me please?
@phildern62034 жыл бұрын
Clean idle jet
@vincentolivieri95613 жыл бұрын
You sound like Ray Liotta
@alaingrenier91283 жыл бұрын
To avoid all of this start your generator at least once every 2 weeks for 10 mins and with a load on it and regular maintenance
@TOURMANBOB2 жыл бұрын
Informative video but I bet the unit would have started and run well by just changing out the old gas. I do believe bad gas is the cause of endless problems with generators of all types simply because they sit for long periods of time without being used and the gas goes bad. My solution is...only use premium non ethanol gas (just like in outboards) and mix some methyl hydrate in the gas for water absorption. I have three generators including the EU6500 and they always start immediately even after being stored some times for more than a year. Just sayin......
@SlavaKolesnikov4 жыл бұрын
U haven't cleaned pilot jet and pilot needle
@darkwood7773 жыл бұрын
But it worked, so not an issue.
@SlavaKolesnikov3 жыл бұрын
@@darkwood777 oh, you really think so?
@Thomas-zh4dy6 ай бұрын
Way to mash that guys door whilst pull starting it.
@srlykistle4 жыл бұрын
My generator runs fine the green light is on when starting but goes out after about 10 minutes? Then generator continues to run but no power to home .Can anyone help me?
@ScienceOfDiagnostics4 жыл бұрын
If the generator itself keeps running but the output voltage drops off then their is likely a fault occurring within the generator section itself. The potential high voltage inside there gen-set really dictate that you take the unit to someone qualified to work on it, otherwise you are risking personal health.
@srlykistle4 жыл бұрын
Science Of Diagnostics thank you for your quick response..stuck without power in calif winds..
@alaingrenier91283 жыл бұрын
Buy a new generator 👍
@darkwood7773 жыл бұрын
It could be a defective inverter on the generator, or you might be simply overloading it so the circuit breaker for the inverter shuts itself off with the motor still running. If your generator has two 110v circuits you are plugging extension cords into, if always helps to balance the load between them. If you are feeding 220v into a panel on the house, It helps to balance the load there so any 110 circuits being used are distributed across both phases. You will need an electrician to advise you on setting up a subpanel to allow the generator to feed into balance circuits in the house. Keep track of what each circuit needs in terms of watts or amps and don't overload the generator running more appliances than needed at one time. Some things like a refrigerator or an A'/C compressor pulls a lot of amps to start, which can throw the circuit breaker on the generator. You may also need a larger generator to run everything you need.
@ct4cf3 жыл бұрын
Less than 1min in& what do I see. A technician pushing off of the door to recoil start. OMG
@darkwood7773 жыл бұрын
The generator case is very sturdy. Not sure why he isn't using the starter motor though.
@ct4cf3 жыл бұрын
@@darkwood777 it’s not the case I spoke of. It is the hinges door. If u look again@ recoil start attempts #2  @20sec &24sec u will see him grab the top of the flapping hinged door2 brace himself &pull the recoil starter. This is why I work on my own equipment This guy would never b trusted 2work on my equipment because he can’t be trusted. Technicians routinely break something else because they aren’t careful. I’ve seen people behave like this4 years.