This Diesel Heater Installed In My Workshop Was So Easy

  Рет қаралды 231,689

retrorestore

retrorestore

Күн бұрын

UK Vevor Diesel Heater This is the 8kw version s.vevor.com/bfP4wU as the 5kw is out of stock
Vevor built In Diesel Heater s.vevor.com/bfP4LU Special discount code for all heaters to save 6% off [ VVheater6 ]
VEVOR USA 8kw heater: s.vevor.com/bfP4OQ
VEVOR UK 8kw heater (open version): s.vevor.com/bfP4O2
VEVOR UK 3kw heater (build-in): s.vevor.com/bfP4LU
VEVOR EU 8kw heater: s.vevor.com/bfP4O4
Exhaust wrap amzn.to/3tObr1X
Power supply for diesel heater amzn.to/3CSR4pq
I decided to install this Vevor 5kw diesel heater in my workshop. Check out my installation video and see how easy it was to install. It gives off great heat and warms up my workshop in a short time.
USA Vevor Diesel Heater s.vevor.com/bfP35W
Discount code VVheater6 can save 6% off
Join me here at kzfaq.info...
The music in my videos is from www.epidemicsound.com/referra...
Stuff I use
The Powder Coating equipment is from Electrostatic Magic and they have kindly supplied me with a discount code for anyone wanting to buy a system from them. Just visit their website www.electrostaticmagic.co.uk/ and when you purchase, Just include the discount code - RetroRestore1 and you will get a 5% discount for all their products.
When customers enter the code when buying a system, they also get free shipping by entering the additional code FREESYSTEMSHIPPING Thus you need to enter both codes separately before making payment.
Sealey Go through socket set amzn.to/3tZtwsC
Respirator Mask amzn.to/3p3MKKs
Clarke King Pro Vac amzn.to/2WDoeT4
Sealey CP1202KIT 12V Ratchet Wrench Kit 3/8 amzn.to/3dgdXa0
Cyclone Dust Separation Collector amzn.to/2S8guKA
Media blasting cabinet amzn.to/2ADpv3c
Dremmel tool amzn.to/2Rcnfuh
Clarke Mig Welder amzn.to/2QwTgrx
A Good quality Makita battery drill amzn.to/2QKcfPy
My Camera Equipment
Gopro Hero 10 Black amzn.to/3Gp1nkE
Gopro 10 Media Mod Cradle (The 9 fits the 10) amzn.to/3q9SRQY
Rode Wireless Go Microphone kit amzn.to/37Et48E
Camera light amzn.to/3ncnLGp
Studio lights amzn.to/2TGzDza
Check out our other channel RETROHAX at / @retrohax
Music
Intro Martin Butler www.totallyroyaltyfreemusic.co.uk
Brushes - www.obsidiandawn.com
Main Tracks Credited to Epidemic Sound (www.epidemicsound.com)
/ retrohax
Twitter at / martinbutleruk
email inquiries: retrorestoreuk@gmail.com
PRIVACY POLICY and FULL DISCLOSURE:
Retrorestore is a participant in the Amazon Services LLC Associates Program (UK)
DISCLAIMER: The product links in this video description contain affiliate links, which means that if you click on one of the product links, I’ll receive a small commission if you purchase. This helps with my channel and allows me to continue to make videos. Thank you for your support.
Retrorestore
MMXXII
All Rights Reserved

Пікірлер: 525
@Tman1969
@Tman1969 6 ай бұрын
It's so refreshing to see a proper man with great knowledge and integrity inspiring younger fellas and girls to use your brain and make things happen in life. We need more of this from us real men and women on this planet.
@stephenroberts4155
@stephenroberts4155 9 ай бұрын
You should run the burner air intake to the outside. You are currently sucking warm air from the air and blowing it out side via the exhaust. On top of that you are creating negative air pressure in the house, sucking cold outside air into the house.
@retrorestore
@retrorestore 9 ай бұрын
No negative air pressure here, its not a sealed cabin, its full of gaps
@stephenroberts4155
@stephenroberts4155 9 ай бұрын
@@retrorestore the burner running creates the negative pressure, so you definitely do. Not running the air intake to the outside is 100% drawing in cold air through the gaps. You’re wasting oil sucking warm air into the burner and out the exhaust. I am talking about the small black intake pipe with filter. 20+ years HVAC experience installing and servicing heating equipment here.
@retrorestore
@retrorestore 9 ай бұрын
@@stephenroberts4155 Thanks for your comment.
@tonystacey3347
@tonystacey3347 Жыл бұрын
You’re in danger of gassing yourself there - couple of improvements. Lay the unit on it’s side and have the first joint and the whole exhaust outside. This joint is notorious for failing and CO leaks. In campers they have a turret plate to allow that joint to go outside. Better to site the unit outside and pull the intake inside if you want the warm air to be heated. If you place inside you can put it on its side needs glow plug on top but the unit first exhaust joint would be sealed outside. Good luck ! You MUST get a carbon monoxide monitor/alarm. Videos are great
@mangebbange
@mangebbange Жыл бұрын
Nice video! A tip is to run them at max setting about 10 minutes before turning of, to reduce soot build up and clogging. Have 3 of these heaters, and first one got clogged up. Can be cleaned up and restored , but that is a booring task. Trust me :) cheers from Sweden
@whoisthis3512
@whoisthis3512 Жыл бұрын
That's a great tip. Thank you!
@davestatham812
@davestatham812 Жыл бұрын
Fantastic Martin, well tidy install and well out of the way too, great little heater is this, just the ticket to keep warm through the winter jobs in the workshop, great video Martin, 👍🏻
@melike1984
@melike1984 Жыл бұрын
Great set up Martin.... WELL DONE ! will make your workshop more enjoyable to work in. and helps others that want to install one.
@evojigger
@evojigger Жыл бұрын
Martin, be careful with the silencer inside, the ones I have had have a drain in the bottom seam to allow water to drip out, not 100% sealed.
@mkroach59
@mkroach59 Жыл бұрын
Also they are only spot welded together and not sealed ....allowing carbon monoxide to escape ! Please mount them outdoors only ! ( Try filling it up with water, you'll find they leak everywhere . )
@VanlifeHQ
@VanlifeHQ Жыл бұрын
Yeah that exhaust 100% needs to vent out completely, them pipe are renowned for braking down leaking exhaust gases inside, I’m sure you can mount them on there side also battery is a must ! not power pack mate if you have a power cut your melt the inside ect buddy they can’t go off when hot
@davidelliott5843
@davidelliott5843 Жыл бұрын
Run the exhaust through a domestic heating radiator angled to drain condensation outside. Corrugated stainless gas pipe will connect the heater to the radiator. Ordinary 22mm plumbing will take the exhaust outside.
@steveclark..
@steveclark.. Жыл бұрын
@@VanlifeHQ What happens when the battery voltage drops? Won't the heater still burn itself out??
@davidgibson4840
@davidgibson4840 Жыл бұрын
I was going to say the same
@jacklucas7265
@jacklucas7265 Жыл бұрын
The oxygen for combustion is being drawn from inside the heated space. As the oxygen is depleted the heater will draw oxygen in from outside and with it cold air. The air/oxygen intake should be placed to the outside to prevent the drawing of cold air into the heated space. This is why fireplaces that are not using combustion air from the outside create cold in the extremities of the heated space, ie: a draft.
@nikoloko5561
@nikoloko5561 Жыл бұрын
Great setup and you explained each part of the demo well done and thank you 👌👍😎
@DiabloOutdoors
@DiabloOutdoors Жыл бұрын
Very clean installation. Exactly what I needed because I'm building a small tiny house next summer.
@sidknowles3467
@sidknowles3467 8 ай бұрын
There is a small hole in the bottom of the silencer for condensation so they can let fumes out into your shed.
@richardmounfield7822
@richardmounfield7822 Жыл бұрын
Great video Martin . You have done a neat and thorough job installing it . Great asset for winter months if you want to do a bit of painting .
@retrorestore
@retrorestore Жыл бұрын
Thanks 👍
@STTC
@STTC Жыл бұрын
Great video Martin, a good installation as expected.
@jlucasound
@jlucasound 9 ай бұрын
Great review! Thanks!
@DiecastPowderCoating
@DiecastPowderCoating Жыл бұрын
You've set that up beautifully Martin. My shed one is a god send and the family are impressed with the house one. Thanks for your advice the other day. Take care, Jeff
@retrorestore
@retrorestore Жыл бұрын
Nice one Jeff, I have the other type as well now.
@DiecastPowderCoating
@DiecastPowderCoating Жыл бұрын
@@retrorestore That's great, I look forward to seeing you installation.
@wardope
@wardope Жыл бұрын
you should use the exhaust to heat water or for steam for a put it trough a Double Convex Radiator mounted on the wall. the exhaust on these things easily hits 200C. so hot enough to boil or heat water.
@mickpurcell272
@mickpurcell272 Жыл бұрын
Very nice setup will deffo keep the workshop nice and warm over the winter period 👍👍👍👍
@retrorestore
@retrorestore Жыл бұрын
Thanks 👍
@gmiller-ls6hz
@gmiller-ls6hz Жыл бұрын
Thank you for this EXCELLENT video, you saved me ALOT of time and trouble with setting mine up. The manual we get in the US it pretty sad, really. You presented all the info I needed in a very clear, efficient manner.
@Babybugex
@Babybugex Жыл бұрын
Thanks for showing the finish job. Well done mate.
@stuartgrant1547
@stuartgrant1547 Жыл бұрын
Looks good martin well happy with the one I got for the shed
@ronschoales2549
@ronschoales2549 7 ай бұрын
Thanks for your install. It will help me to install mine. Appreciate the help ! Ron - Canada
@Alandixon88
@Alandixon88 Жыл бұрын
Been waiting to watch this!! Nice one Martin. Ive ordered one up
@ericmetcalf6419
@ericmetcalf6419 Жыл бұрын
Thank you for the video. I had a camper furnace in my 3 meter by 6 meter shop but it died last year this is going to be a great replacement
@stevo4649
@stevo4649 Жыл бұрын
thankyou Martin a great set up,,have a good weekend,👍👍
@davidquarles5965
@davidquarles5965 8 ай бұрын
I'm glad you showed the exhaust and talked about it. I keep seeing these online where people run the exhaust into their building, to save fuel--a huge problem and asking for trouble, in my opinion. It is difficult to convince some people that you can't burn fuel in an enclosed space without venting to the outside.
@georgedeaney7270
@georgedeaney7270 Жыл бұрын
FYI for others that want to install these. With a single wall shed, the heater should have been mounted on its side with the exhaust and combustion air external and glowplug at top. The golden rule is big pipes inside and small pipes outside. Under certain fault conditions there is always a chance of combustion air exiting the inlet, so another reason for keeping the small pipes outside. Always fit a CO detector.
@cfcyayaya
@cfcyayaya Жыл бұрын
Well said George. Any idea how to avoid the power cut failure mode?
@georgedeaney7270
@georgedeaney7270 Жыл бұрын
@@cfcyayaya Just depends how many power cuts you might get. There is a argument by some for having a battery capable of starting and shutdown with a smart charger. The what if scenario then comes into play. For there to be any chance of damage( I don't subscribe to the theory) the heater would have to be flat out for a while at exactly the same time as the mains fails - bookies odds?. The battery and smart charger could cost more than the motherboard. For me I assume that those that advocate a battery etc have a standby generator to power the fridge, freezer, boiler etc just in case the mains fails. Backup water supply and so on.
@whoisthis3512
@whoisthis3512 Жыл бұрын
So does the unit automatically enter the power down mode when the fuel runs low? Also if my power goes out and I have the battery setup will the heater just keep running or will it enter the power down mode? I want to install mine with the battery and tricke charger.
@normangibson9907
@normangibson9907 Жыл бұрын
@@whoisthis3512 hi I ran mine on a battery and trickle charger in a mobile home for 2 years with no problems. I now have the unit in a van that charges my second battery from main battery when van is running. It's a bit more fiddly setting it up as you should run inline fuses between the 2 batteries and a switch to stop charging so you don't flatten your van start up battery but well worth it, i would highly recommend these units for cheap and easy way to heat garage mobile home caravan and campers. I also have been running it on kerosene which is half the price of diesel here and I think in my own opinion it burns cleaner than the diesel and just as warm.
@haydenuk02
@haydenuk02 Жыл бұрын
Nice diesel heater. Thanks for sharing this with us take care
@MsMicheal12345
@MsMicheal12345 Жыл бұрын
hi martin had one in my mancave for past 2 years and it works a treat, same here what evojigger just mentioned with the exhaust box having a hole in / drain hole .i put the exhaust pipe through the shed with the box on the outside
@ShadowzGSD
@ShadowzGSD Жыл бұрын
i have really got to get me one of these, would go lovely in my workshop, probably get a bit of use in my bathroom first until i get my boiler replaced.
@johnobiro5202
@johnobiro5202 Жыл бұрын
Nice one Martin. I’ll be fitting mine in the garage next weekend. I’m going to try the one with the Bluetooth. 🔧👍
@ericharris3728
@ericharris3728 Жыл бұрын
2 things i would put the combustion air intake outside. having it inside means that you have to suck cold air from outside for combustion. 2: i would probably un cover the exhaust, cant hurt the little extra heating. :D
@darrick9302
@darrick9302 Жыл бұрын
I'm confused. Why does it suck combustion air from outside if the combustion air intake is inside?
@fixitorstripitGardenmachines
@fixitorstripitGardenmachines Жыл бұрын
Nice one Martin does the job which is the main thing and very well explained
@paulp96275
@paulp96275 Жыл бұрын
Martin very tidy installation previous comment on silencer is right about the fumes coming from the drain hole great vid stay safe top lad 👍👨🏻‍🏭
@motorcyclewild5873
@motorcyclewild5873 Жыл бұрын
Cheers for the update video. Think Iam going have to invest in one
@Stefanos.Tsokaras
@Stefanos.Tsokaras 5 ай бұрын
Very nice video, I think that I will install my new vevor heater like this. Thank you Sir!
@alandykes2519
@alandykes2519 Жыл бұрын
Spot on Martin nice and warm now look forward to the portable one coming up as i have got a brick garage attached to my property and I don't think the council would like me drilling a hole through the wall for the exhaust pipe 👍👍👍👍
@derekbevan7145
@derekbevan7145 Жыл бұрын
The next experiment would be to build a heat exchanger around the exhaust.
@haroldbell1097
@haroldbell1097 Жыл бұрын
I fitted a cab heater (Eberspacher) in my workshop over 25 years ago before the cheap versions were available, as others have pointed out it is preferable to run the instalation via a 12v battery and battery charger, this will ensure correct shut down procedure in the event of a mains powe failure. Even if its running when the power fails eventually the low battery voltage wiill shut the until down correctly without damage.
@whoisthis3512
@whoisthis3512 Жыл бұрын
Thank you. Now I'm definitely going to run mine on a battery with a trickle charger. Do I need a marine battery or just a regular battery since I'll be using a trickle charger? Just a regular battery right?
@haroldbell1097
@haroldbell1097 Жыл бұрын
@@whoisthis3512 .Any 12v lead acid battery will do the job, just find the cheapest popular battery, even a lawn mower one would do the job.
@cidercecil
@cidercecil Жыл бұрын
@@haroldbell1097 would a 12v, 12Ah one from a mobility scooter be ok? Many thanks 😊
@paulhands2763
@paulhands2763 Жыл бұрын
A solid piece of advice for anyone buying these cheap heaters be very careful they don’t go up in smoke, a number of these have, I work for a major manufacturer of air and water heaters.
@spaceportseven
@spaceportseven 8 ай бұрын
Would be good to know for safety reasons what it's it that causes them to do this , is it bad fitment or mechanical failure, or design flaws? There must be ways to eliminate or reduce the risk
@spaceportseven
@spaceportseven 8 ай бұрын
Maybe because these heaters are so good and you work in the competing UK traditional heating industry Mr @paulhands2763 your talking shyte as your see these heaters as a threat
@timw4926
@timw4926 Жыл бұрын
Fantastic insulation Martin. Very good indeed.. you do such a fantastic job.... well done...
@retrorestore
@retrorestore Жыл бұрын
Thank you! Cheers!
@derbyjohn972
@derbyjohn972 Жыл бұрын
Amazing bit of kit. Have one in the T5 camper 😍😍
@paulhaywood5197
@paulhaywood5197 Жыл бұрын
The exhaust bandage holds the heat in the system, which saves on fuel, plus the machine warms up quicker than without. Thanks for your vidios, very helpful, Paul.
@Rustbox306
@Rustbox306 Жыл бұрын
No, it prevents a portion of the heat transfer from going inside the heated zone, reducing the system efficiency.
@MurderNeal
@MurderNeal 9 ай бұрын
Well done!
@davidshelton876
@davidshelton876 Жыл бұрын
Such a useful video. Thank-you so much.
@jeffrob5791
@jeffrob5791 6 ай бұрын
Great description thanks i built a garden gym for me and grandson its got a electric fan when other appliances are on in house such as kettle tumbler dryer oven it jumps from 79 pence a hour to over 2 quid an hour , Ive got a friend coming to fit me one of these in gym im not clued up on this luckily he comverts camper vans lookin forward to it hopefully it should stop him getting damp air on lungs and me too. Thanks
@johnclamshellsp1969
@johnclamshellsp1969 Жыл бұрын
Always great videos as always Martin. I just installed my Diesel air heater as well, they work amazingly for the price. Since your running the exhaust through the wall, just straight pipe it outside with no muffler. You will find much better airflow, wth about a 5"F/8''F increase. Noise is hardly increased with that little muffler removed. For my setup, I used 3/4 copper tubing, and zero back pressure. The Flexi pipe in the kit makes many ripples in the flow due to the ribbing. 60107 USA says hi.
@retrorestore
@retrorestore Жыл бұрын
Thanks John
@whoisthis3512
@whoisthis3512 Жыл бұрын
Copper is a good idea. Thank you-
@Turleyswheels
@Turleyswheels 8 ай бұрын
Brilliant mate absolutely ace
@acurrentname
@acurrentname Жыл бұрын
Thanks for the video, it will be nice and toasty on cold days in there. You could improve efficiency more by running the air intake for the burner to the outside of the cabin, that way you aren't using the warm air inside for the burner..
@georgedeedsnotwords2162
@georgedeedsnotwords2162 Жыл бұрын
Great video bud . I think I'm going to mount my fuel tank on a board with hinges on back edge . That way I can swing it out from wall for easy filling . Hope it works as well as anticipate .
@davidpriestley3268
@davidpriestley3268 Жыл бұрын
I would definitely consider moving the silencer outside. The less joints you have inside, the less chance of leaks and there is a small hole in the bottom of the silencer for condensation drips so they can let fumes through. Enjoy your vids too much to loose you.
@barrymills1196
@barrymills1196 Жыл бұрын
Nice job. I've got a Chinese one I've been meaning to fiit in my workshop, this might just spur me on, that and the cold weather. You might want to fit a carbon monoxide alarm, keep yourself safe!
@thornwarbler
@thornwarbler Жыл бұрын
Great follow up👍👍
@rodkirt9273
@rodkirt9273 Жыл бұрын
One suggestion : Replace the full line from the pump to the heater with ridged plastic fuel line . The green line softens up a bit and you will eventually get a “ low fuel “ error from the controller . The pulse pump only produces 0.02 mm of fuel per pulse and the green tubing expands a little bit and the sensor will turn off the heater with a “ low fuel “ warning .
@shannonbalgaard4494
@shannonbalgaard4494 Жыл бұрын
Yeah the correct fuel line diameter is very important on those units it won't work if you don't have the right size hole you'll get too much or not enough fuel, the hole inside that fuel line is so small it's like a pin can barely fit in there it's it's incredibly small
@bethwills5878
@bethwills5878 8 ай бұрын
What are the specs for the fuel line if you were to replace it with sturdier line
@curtwuollet2912
@curtwuollet2912 6 ай бұрын
2 mm id​@@bethwills5878
@davidvickers9029
@davidvickers9029 Жыл бұрын
Nice job Martin👍
@acegolfman3203
@acegolfman3203 Жыл бұрын
Very well explained. Interesting
@edwardbroomhead4463
@edwardbroomhead4463 Жыл бұрын
Very tidy install Martin, bet it’s lovely and warm in there now and will make doing jobs in the workshop that bit more enjoyable. Definitely sort a carbon monoxide detector though for the few pounds they cost to keep yourself safe 👍
@retrorestore
@retrorestore Жыл бұрын
Absolutely
@mikeb3010
@mikeb3010 Жыл бұрын
Nice job mate, going to commission mine this afternoon (portable) I did notice the silencer only had a few little spot welds around it, when I blew through it, it leaked like a sive, so I brazed around the edge, I’m trying my luck with a 15A 200w power pack, the type with jump leads, up rated the Cig lighter to 15A fuse, I’ve decided to fit the unit externally (water proofed) with ducting coming in as I do a lot of woodwork. Great vid mate 👍
@retrorestore
@retrorestore Жыл бұрын
Nice 👍
@tray8411
@tray8411 5 ай бұрын
Nice work!!!!!
@thisnthat3530
@thisnthat3530 Жыл бұрын
Those silencers leak like sieves. Not just the drain hole but the ends are only tacked on. Sucking combustion air from inside will exacerbate the leakage by lowering the pressure in the shed. Make sure to have a working CO detector. Also, put a battery in the supply so a sudden power interruption can't damage the unit.
@fredfred2363
@fredfred2363 Жыл бұрын
Yes, This. So many people don't realise and are getting gassed with CO...
@itsallfabrication
@itsallfabrication Жыл бұрын
Nice one Martin, good installation.
@retrorestore
@retrorestore Жыл бұрын
Thanks 👍
@robertbarbour7017
@robertbarbour7017 Жыл бұрын
Good video mate.
@alanjackson4646
@alanjackson4646 Жыл бұрын
Those silencers are to make the exhaust noise quieter outside the habituated space as they leak like sieves. I am going to do the same in my garage.Regards AJ
@crazy-diamond7683
@crazy-diamond7683 Жыл бұрын
Mine is pretty much the same set up, I run mine on red diesel with a 50/50 mix of kerosene it burns slightly hotter and i always leave mine on H2 and use the "alpine" mode when it's warm enough. Every Man and his dog will tell you "how you should have fitted it" I say if it works for you then its a win win! I do agree the silencer should be outside and a change of fuel line to the rigid type. Embark on a CO meter for your own safety my friend and maybe you can cut and push one of the hoses through the wall to heat the other side.
@TurboTimsWorld
@TurboTimsWorld Жыл бұрын
Nice install but the burner side "air in" supply for safety should be also taken from outside (the black tube above the exhaust) that means any risk of CO goes in and out from outside and your inside "air heat in and air out" from inside. If you look how its mounted to the floor of a camper it makes sense, burner air from under the van heat air from inside. BUT also your setup as per the video is sucking warm workshop air burning it and throwing it outside you may create a negative pressure (pos not in a wooden workshop) but you could in perfectly sealed space get poor combustion and CO levels build up. You also could "harvest the heat from the exhaust" by using metal air duct tube over the top of it and blowing air through it. great video I had a camping gas powered heater like this one so if you don't want diesel camping gas versions are available.
@thermos750
@thermos750 Жыл бұрын
Nice work mate!! From watching 4-5 videos today from these heaters, it is "not" recommended using "copper" with diesel heaters. The two don't mix and you can create some bad CO2 from the copper as the oil exhaust does not mix well.....I see that there is other kits you can get to extend your current exhaust that is the same piping as you have.
@royevans4581
@royevans4581 Жыл бұрын
Just a suggestion. I would run the combustion air intake (thin pipe) from outside, as particularly in winter, when you need it most, the air is cold and therefore more dense, making for a more efficient burn. Think intercoolers in turbo engines. Where you have it at the moment, it will be flowing less dense air the warmer the inside space becomes. If you choose to do that with the cold air inlet, make sure it is a good distance away from the exhaust outlet. You don't want to be sucking in exhaust gases! Cheers mate. All the best.
@retrorestore
@retrorestore Жыл бұрын
Thanks Roy
@LOGIBEAR01
@LOGIBEAR01 Жыл бұрын
That's not exactly correct. I work with large power and recovery boilers. They are 10 stories tall. We pre-heat the combustion air with heat exchangers fed by the boilers flu gas to recover the heat leaving the boiler. We also use the flu gas to pre-heat the feed water going into the boilers to recover even more flu gas temperature that would otherwise be wasted. The boilers also draw warm indoor air from that plant. This make them more efficient because you don't need to waste heat by buring more fuel per unit of work output to heat cold outdoor air and cold feed water. If you don't have to burn more fuel to make up for the cold air and water, you can generate steam with less fuel. Having the air intake with in the room being heated, drawing heated air the unit is producing, will decrease fuel consumption per BTU of effective heat entering the heated space. Forced induction engines are more efficient in terms of power generated per unit of displacement. They are not, however, nessisarily more efficient in terms of the unit of fuel burned vs unit of work output. The math is very well understood on this matter. There are whole perrfessions to do with thermal dynamics.
@josephsmuckatelly8767
@josephsmuckatelly8767 Жыл бұрын
You might consider not wrapping the exhaust pipe to help get more heat in the shop, as long as there is little possibility of personally getting burnt on it. Nice job.
@ologhai8559
@ologhai8559 Жыл бұрын
i am wondering if you could put the exhaust pipe into the sand to make "sand battery" to keep the warmth for even longer
@michaeldibb
@michaeldibb Жыл бұрын
Looks a nice install. Just be aware the silencer is only spot welded together. So it isn't gas tight around the edges, meaning some exhaust will end up inside.
@retrorestore
@retrorestore Жыл бұрын
I'll be moving it outside
@dancaissie3486
@dancaissie3486 8 ай бұрын
i was going to say this exact thing, but decided to read the comments first. good job @@retrorestore
@LordFalconsword
@LordFalconsword Жыл бұрын
The manufacturer has done an incredible job increasing quality of build and reducing fuel use, especially when you consider the commercial version is well over $1,500!
@paulbutterworthbillericay
@paulbutterworthbillericay Жыл бұрын
Great job, attach the air intake to the outside then you won't burn off your warm air inside, could direct one of your blow out vents towards your other 4x4 workshop whack a hole though the wall, is it big enough to heat both?, might have to get one myself
@madcyborg
@madcyborg Жыл бұрын
As someone who also relies on a diesel heater for workshop warmth... may I suggest (humbily) a CO detector? For not much money, it could be a great edition. Over time the gaskets can seep - it's rare but does happen.. Good video and be well. ( I wrote this before watching the whole vid, You mentioned getting one ;)
@mickydint
@mickydint Жыл бұрын
Hi Martin, just fitted one in my garage and didn't like the idea of the silencer so I was going to fit it outside. However I decided to try it without the silencer thinking that it's not an engine as such . So I fired it up and I found without the silencer there is no appreciable noise at all out of the end of the exhaust!!. I did try it with the silencer on the end first but as I said on taking it off there was no difference! .
@You-can-fix-it-yourself
@You-can-fix-it-yourself Жыл бұрын
Nice rig, well thought out. If you want to scavenge the heat from the exhaust, then route the exhaust tube through a 4" duct, and put a small fan at the end of the duct. more heat, less loss, less fuel.
@newyork1655
@newyork1655 6 ай бұрын
the comment I was looking for ! Tnku , there are other wraps I was thinking about , w fingers like sticking in all directions, …exhaust is soo hot! We need to find a way how to use that heat , tnku!
@garywalker3818
@garywalker3818 Жыл бұрын
good blog martin keep them coming Gary from Crewe 👍👍👍👍👍👍
@petervantonder2965
@petervantonder2965 Жыл бұрын
Nice video, thank you, what Disel do you use, thinking of getting one of these
@davidcalder8912
@davidcalder8912 Жыл бұрын
Hey there - just wanted to say that this video (and your previous one) have persuaded me that this is the way to go to heat my workshop over winter. I was looking at a log burner, but it was so expensive, and a pain to install. We have a diesel generator, so always have red diesel "on hand" - it makes so much more sense than a log burner, particularly when I'll probably only use it 4 months in a year. Thanks mate.
@cross13000
@cross13000 Жыл бұрын
Great vid , thanks.
@retrorestore
@retrorestore Жыл бұрын
No problem 👍
@FRUGALWITHJOHN
@FRUGALWITHJOHN Жыл бұрын
Nice setup, I just did a 5 year review video on mine. I use it to heat a 2 car garage.
@bettylovell173
@bettylovell173 Жыл бұрын
😃love it. have ordered the power supply for mine as well the pipe wrap. going to be using mine in my pollytunnel & use a used short scaffold pole to extend the exhaust to the outside. hoping it works but love your ideas & have used yours links.
@retrorestore
@retrorestore Жыл бұрын
Nice 👍
@davidlean2879
@davidlean2879 Жыл бұрын
Nice neat job !
@retrorestore
@retrorestore Жыл бұрын
Thanks!
@roystheboy
@roystheboy Жыл бұрын
Nice setup martin my friend has one and when it's the cold part of the year he leaves he's running at temp 63 all the time
@roystheboy
@roystheboy Жыл бұрын
Thanks
@stephenthomas729
@stephenthomas729 Жыл бұрын
Absolutely love your videos sir
@retrorestore
@retrorestore Жыл бұрын
Thank you kindly
@Honky_Konky_Phooey
@Honky_Konky_Phooey Жыл бұрын
Nice install Martin hopefully a fire extinguisher close by too 👍
@yodasith4941
@yodasith4941 Жыл бұрын
Just installed one in my office, it's great but I installed mine outside due to noise, not sure the plugged-in power supply is 100% safe, if you have a power cut you could have a meltdown (i know this does not happen often)! Got mine connected to a battery with a battery maintainer plugged in, like my office in one piece and not producing heat having been set on fire!
@redauwg911
@redauwg911 Жыл бұрын
good video thank you
@simonkershaw8201
@simonkershaw8201 Жыл бұрын
Martin , you could put one outlet in each half of your cabin and warm the whole lot up .
@glynwilliams1225
@glynwilliams1225 Жыл бұрын
Nice installation Martin “👌
@retrorestore
@retrorestore Жыл бұрын
Thanks 👍
@shanepowers7566
@shanepowers7566 Жыл бұрын
Thanks, from Oklahoma, USA.
@retrorestore
@retrorestore Жыл бұрын
Thanks for watching!
@chrisharrell2449
@chrisharrell2449 Жыл бұрын
Looks good, but you might consider what may happen if you get a powercut while using heater. It could cause the electronics to over heat . Lots of people take the risk, But I found this on aliexpress. A power supply with a battery charger built in, and UPS, if there is a powercut it automaticaly switches to battery power. link will be bellow. This works a treat for my emergency house heating. Mounted outside but in a insulated metal cabnet, with flow and return holes through house walls. so as the same as you have warm air is recyled not drawing cold outside air in! plus the tank is outside completely, I may have think about anti gelling stuff if it gets very cold diesel. but no worries of spilling diesel indoors it only been fitted for a short while already I am using it instead of central heating, Its direct into living room. and on lowest it is hotter than the central heating, even leaving doors open to rest of house. In think this will save me on energy bills Link. 180W Switching Power Supply 12V 24V Monitor Universal AC DC 13.5A UPS/Charge Function Input 110/220v Battery Charger SC180W
@SwedenLover090
@SwedenLover090 Жыл бұрын
Nice video... thank you.
@garyphillips7993
@garyphillips7993 Жыл бұрын
Nice tidy installation Martin. I used the same exhaust tape on mine - it works a treat, the exhaust barely gets warm now. Nice to see you went down the power supply route 👍 Don’t know if you realise this, but those vent pipes expand to about twice the length they are when supplied?
@retrorestore
@retrorestore Жыл бұрын
Yes I know Gary. Cheers
@cupcakecontent2226
@cupcakecontent2226 Жыл бұрын
Nice job
@djmarine4499
@djmarine4499 Жыл бұрын
You need to remove the silencer from inside the building the condensation drain at the bottom also allows combustion gases out as well such as carbon monoxide you can get a marine silencer for inside use if you wish to have one that's fully sealed and room safe a cracking addition to any space that needs heating cheaply and easily though
@smitcher
@smitcher Жыл бұрын
I was about to say the same about the silencer and condensation drain being moved to outside. Also, the point you touched on about not turning of the power to the unit - this is why it's best to have a 12v battery being trickle charged and powering the unit because then in the event of a power failure (brownout, blackout or just RCD trip) your unit is still powered and can be shut down safely... Nice little setup though and you should get some good use out of that...
@PeterAndersons
@PeterAndersons Жыл бұрын
Looks great Martin, my shed gets freezing as well! At 12C you're in a T-shirt? Today our top temperature was 14 and I was in a jumper and jacket haha, cheers.
@normsmowers4758
@normsmowers4758 Жыл бұрын
Great idea top job
@retrorestore
@retrorestore Жыл бұрын
Thank you! 😊
@yolandeportor6800
@yolandeportor6800 Жыл бұрын
Love watching
@BorisJonsson
@BorisJonsson Жыл бұрын
cool video and a cool guy 👍
@MCscarfacematt
@MCscarfacematt 6 ай бұрын
the remote works from a fair distance away too ive got an all in one unit in my shop i use the remote to turn it on let it warm up for a bit before i head out there mines hooked up to a battery but thats because i also use the battery to power a winch i use to pull my project in the shop and qith a snatch block hanging from the ceiling it doubles as a crane because lifting stuff post stroke sucks
@billienomates1606
@billienomates1606 Жыл бұрын
Nice setup, although I did see several vid's saying the fuel filter needs to be vertical to maximise getting rid of any air bubbles supposedly. Like n sub.
@Jutulind
@Jutulind Жыл бұрын
One little tip on power supply too from here - it's better to use car battery with smart charger. Why? Because in case of power outage your burner with battery backup will not stop abruptly. And it actually needs this cooldown cycle. If the fan stops running while burner has been on full power it can melt the plastic as there is no cooldown.
@PAULSWorld131
@PAULSWorld131 Жыл бұрын
Heat always travels up. You need to install the heat outlets just above the floor, otherwise you only heat up the area at the cealing.
My Diesel Heater Runs On This - Cheaper Than Diesel
13:55
retrorestore
Рет қаралды 187 М.
10 GENIALE MÄNNER GADGETS, die jeder Mann haben sollte in 2024
14:01
I wish I could change THIS fast! 🤣
00:33
America's Got Talent
Рет қаралды 119 МЛН
Can You Draw A PERFECTLY Dotted Line?
00:55
Stokes Twins
Рет қаралды 101 МЛН
Дибала против вратаря Легенды
00:33
Mr. Oleynik
Рет қаралды 5 МЛН
버블티로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 111 МЛН
FORT MONDEO POLEN FİLİTRESİ DEGİŞİMİ.
0:59
Tekin Katırcıoğlu
Рет қаралды 575
Installing a small diesel heater in the workshop
47:05
Ants Pants
Рет қаралды 168 М.
LOW SETTING AND ALPINE MODE TEST ON 5kw DIESEL HEATER .
10:27
Vanflippingtastic
Рет қаралды 79 М.
My Vevor Chinese Diesel Heater Stopped Working. Can I fix it??
36:32
Alaskan Homesteading
Рет қаралды 22 М.
Unfiltered 100% Waste Oil Vs Stock Diesel Heater
19:38
SteinFab Garage
Рет қаралды 273 М.
Shocked - Using This Diesel Heater In My Workshop
19:42
retrorestore
Рет қаралды 360 М.
Chinese Diesel Heater Buyers Guide & Tried and Tested Heaters 2023/2024
48:49
Van Life Uk A Complete Survivors Guide
Рет қаралды 99 М.
three feet under the keel   #offroad
1:00
Nivulin 4x4 video
Рет қаралды 995 М.
W truck driver #edit #trollface
0:20
TRET1
Рет қаралды 5 МЛН
Ninja H2 Moto Tourist Bogey Biker Highlights -Ride4 Isle Of Man Drive Motorcycle Race Crashes #crash
0:20
DIY Bike Wheel Fixing
0:12
For Crafts Sake Shorts
Рет қаралды 2,8 МЛН