Toilet Ventilation, Oatey Sure Vent Install

  Рет қаралды 44,952

SRTPCC

SRTPCC

Күн бұрын

Please Consider Subscribing & Liking, Big Thanks!

Пікірлер: 54
@randyriggs5463
@randyriggs5463 2 жыл бұрын
That 3" combination serving that toilet should have been a 3" long sweep. Before that combination, you could have put a 3" wye to serve your sink. That would have been your vent to. Then make sure that you are not close than 15" center to center of your fixtures.
@SRTPCC
@SRTPCC 2 жыл бұрын
That's a 4" long sweep to the toilet, hard to see. But I like the Y idea. I like the comments on how to make it better
@chiefeagle5882
@chiefeagle5882 3 ай бұрын
that vent is required to be above the flood level of the fixture! It will leak in the future.
@randydemars3734
@randydemars3734 Ай бұрын
Cutting off a sewer pipe just above his canned good storage! Not eating at his house!
@SRTPCC
@SRTPCC Ай бұрын
Hahahaha
@sonnynguyen8012
@sonnynguyen8012 Жыл бұрын
Thank you so much for useful video ❤
@SRTPCC
@SRTPCC Жыл бұрын
Glad it was helpful!
@sonnynguyen8012
@sonnynguyen8012 Жыл бұрын
@@SRTPCC ❤️
@elmono3939
@elmono3939 2 жыл бұрын
There is so much wrong with plumbing in this video that I don't know where to begin. To everybody who is watching this - please do not follow this DYI's instructions. Consider yourself warned. Thank you
@vicschauberger2737
@vicschauberger2737 9 ай бұрын
Agree. Do not follow this demonstration .
@4doorsmorewhores674
@4doorsmorewhores674 9 ай бұрын
lol im fixing to do it lol that lower vent he is putting in is only a problem if there is ever a clog right?
@mouuseygb
@mouuseygb 9 ай бұрын
@@4doorsmorewhores674 Technically yes. But do you want to chance that?
@gildardomerancia5818
@gildardomerancia5818 9 ай бұрын
Hey buddy just keep both vents it will probably work better .
@SRTPCC
@SRTPCC 9 ай бұрын
Truth
@randolphrussell1751
@randolphrussell1751 2 жыл бұрын
Does not look like this would pass a plumbing inspection. Never thought it was a smart idea to put a Studor vent BELOW the fixture it was supposed to vent. It the under sink Studor was installed correctly then a 2" vent would be enough to vent the crapper. Total distance from the centerline of the flange doesn't look to be over 5 feet or so. Please follow up in the future when you have a sewer line blockage and the effluent backs up to your vent.
@brianczuhai8909
@brianczuhai8909 2 жыл бұрын
Potential clogs is the reason the air admittance valve vent needs to be above the top water level of a fixture. It's also the problem using them UNDER sinks. The one way valve on them may fail.
@vicschauberger2737
@vicschauberger2737 9 ай бұрын
This is wrong . You need a 3"x 2" wye before and within the code distance of the 3" toilet 90 or a 3" x 2" side outlet 90 at your toilet . The the 2" of either of those configurations runs to your Lavy ( sink ) . The in-line vent should be 6" above the flood level rim of your lavy to prevent debris from clogging your vent in case of a drainaige back up . . Now , with what you did , the sink also has no vent . This is supposed to be a wet vent configuration . Where the lavy can vent the toilet . It's best to run the 1 -1/2" lavy vent thru the roof . That's just the beginning of what's wrong with this . Sorry .
@user-fg8ns5ud9l
@user-fg8ns5ud9l Жыл бұрын
What did you put on (like a cap) at the last step right before the flush test?
@SRTPCC
@SRTPCC Жыл бұрын
That is a threaded clean out plug from where the vent was originally
@happysunflower4586
@happysunflower4586 2 жыл бұрын
Thank you! My vent is letting moisture come into the cabinet underneath my kitchen sink. I think I will replace the vent and see if that helps. I have a feeling the vent might be all in this faulty???? Any suggestions?
@SRTPCC
@SRTPCC 2 жыл бұрын
I believe they are open to air by design. From what I know water is what it won't let out.
@bwrick21
@bwrick21 Жыл бұрын
Can you hook up a studar for all bathrrom fixtures?
@SRTPCC
@SRTPCC Жыл бұрын
I'm no plumber but I think one does the trunk line for all three fixtures, Toilet/Sink/ & shower
@amandawallace105
@amandawallace105 2 жыл бұрын
My kids restroom toilet is doing the same thing and has a nasty smell no matter how much a clean it. Is that a sign it needs to be vented?
@SRTPCC
@SRTPCC 2 жыл бұрын
If there's a smell I'm thinking there's already a air leak somewhere that needs to be tracked down. I'm not certain a vent install would fix your prob but there's way smarter ppl on here than me on this, sorry
@amandawallace105
@amandawallace105 2 жыл бұрын
@@SRTPCC the toilet does move around, could it be the wax ring ?
@SRTPCC
@SRTPCC 2 жыл бұрын
@@amandawallace105 Yes Ma'am
@SRTPCC
@SRTPCC 2 жыл бұрын
Check for toys down there also with kids maybe
@amandawallace105
@amandawallace105 2 жыл бұрын
@@SRTPCC 😆🤣 my kids are teenagers , I really hope no toys are in the drain
@user-nn1lo8sj9y
@user-nn1lo8sj9y 4 ай бұрын
bad bad jobber !!!!!!!
@SRTPCC
@SRTPCC 4 ай бұрын
IKR
@Mybattlefieldlife
@Mybattlefieldlife 28 күн бұрын
Code ? Never heard of her 😂
@SRTPCC
@SRTPCC 27 күн бұрын
Hahaha right
@georgetsetsakos6088
@georgetsetsakos6088 2 жыл бұрын
"It's a little pasty!" That's legit. lol
@ABOULBARAHEM
@ABOULBARAHEM Жыл бұрын
What if you install the vent on the 100mm pipe not the 50mm does it still do the same work ?
@SRTPCC
@SRTPCC Жыл бұрын
I believe that would be the correct way between the toilet & the sewer
@steved2510
@steved2510 2 жыл бұрын
That toilet is wet vented thru the lavatory and a toilet can be unlimited distance from a vent because it’s a self siphoning fixture.
@SRTPCC
@SRTPCC 2 жыл бұрын
Right on
@brianczuhai8909
@brianczuhai8909 2 жыл бұрын
That's because the toilet bowl keeps filling after the flush and reseals the trap. However, if vented properly you won't get that glug, glug, glug sound of air being sucked into the bowl right after the flush. Since there's a vacuum pulling the air through the trap in the bowl, it also pulls back the flush going down the pipe.
@MarkMinistries
@MarkMinistries Жыл бұрын
How big is that Oatey vent 3 inch or 4 inch?
@SRTPCC
@SRTPCC Жыл бұрын
It fits 1 1/2" or 2" both
@sarahmangone7785
@sarahmangone7785 Жыл бұрын
Also, it's installed too low. After watching it fully, I see you moved it up.
@haitong7305
@haitong7305 2 жыл бұрын
Can you put the air vent side way or it have to be up right?
@SRTPCC
@SRTPCC 2 жыл бұрын
It needs to be up for valve to work right
@arlenmargolin4868
@arlenmargolin4868 2 жыл бұрын
It looks like you went way down in pipe size you need to keep a large vent the same size otherwise I think it will have that problem
@SRTPCC
@SRTPCC 2 жыл бұрын
Still working great
@sparky3869
@sparky3869 2 жыл бұрын
The plumbing is done wrong. If it were pipe correctly, it would not have been a problem.
@SRTPCC
@SRTPCC 2 жыл бұрын
Seems to work good but yes I just pieced it tog myself
Air admittance valves for plumbing venting explained, [just over 4 minutes]
4:19
Rising Tide Plumbing
Рет қаралды 101 М.
Air Admittance Valves
9:27
Structure Tech Home Inspections
Рет қаралды 237 М.
Yum 😋 cotton candy 🍭
00:18
Nadir Show
Рет қаралды 7 МЛН
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 47 МЛН
Мы сделали гигантские сухарики!  #большаяеда
00:44
小丑把天使丢游泳池里#short #angel #clown
00:15
Super Beauty team
Рет қаралды 47 МЛН
Washing Machine Box
11:26
Plumbing Solutions, LLC
Рет қаралды 443 М.
How To Vent & Plumb a Toilet (in 2024)
6:59
Hammerpedia
Рет қаралды 2,4 МЛН
What are plumbing vents for...and why you NEED them
8:01
Roger Wakefield Plumbing Education
Рет қаралды 51 М.
How to install a toilet flange! Plus finishing up the bathroom flooring! #543
18:42
The Kelley's Country Life
Рет қаралды 735 М.
How to identify and correct a venting problem with a shower drain.
8:11
Bearman the Handyman
Рет қаралды 177 М.
How To Vent Plumbing Pipe - Toilet, Bathroom Sink, and more!
28:30
The Excellent Laborer
Рет қаралды 341 М.
Bathroom Extractor Fans - a DIY Guide
26:38
Charlie DIYte
Рет қаралды 868 М.
Air Admittance Valve Installation
3:26
Apartment Maintenance Pro
Рет қаралды 51 М.
Yum 😋 cotton candy 🍭
00:18
Nadir Show
Рет қаралды 7 МЛН