COOKER VENTILATION PROBLEMS. gas tutorial on the correct ventilation need with no openable window.

  Рет қаралды 7,919

Tomkat Gas Training

Tomkat Gas Training

Күн бұрын

Derek takes us through cooker ventilation problems and reviews the building regulations document f, bs 5440 part 2 and gas safe technical bulletin 005(a) on the correct ventilation needed when installing a gas cooker or hob. He looks at the problems engineers can be faced with when a conservatory has been built across the kitchen opening and how the engineers can rectify these problems..

Пікірлер: 55
@donwalker9767
@donwalker9767 3 жыл бұрын
Hi Derek just passed all my gas reassessment exams and wanted to say Thankyou. Your videos have been fantastic for preparing me to take the exam and practical again. Brilliant you take the time to make these videos. Thankyou 👍🏻
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
Congratulations on passing 👍🏻
@Smiley-vp2pn
@Smiley-vp2pn 3 жыл бұрын
very helpful videos Derek . Thank you for your time and energy . love all the videos i have seen so far and look forward to all that follows. Keep up the good work
@mj0n4id36
@mj0n4id36 3 жыл бұрын
Interesting. One to get your head around. Looked *REALLY* confusing at first. However, like always, after watching your videos from start to finish I find that you explain it well with great examples. I’m glad I can access these videos at any time. Much appreciated. Thanks Derek 👍🏻 Asian Jon. Training.
@sodig876
@sodig876 3 жыл бұрын
Well explained 👍 I had a conversation with gas safe regarding this in. gas safety check, and they confirmed it as NCS as the room size was correct. Problem is the appliance can't be replaced As it currently is!
@russellbird2246
@russellbird2246 3 жыл бұрын
Just heads the dilemma on a land lord, thanks again on deciphering the TB05a in working practical form
@mohammednadeem7274
@mohammednadeem7274 3 жыл бұрын
Another excellent video Derek & well explained, your maths is brilliant I'm not that Good with maths so we're in the same boat, why are building regs making things complicated, the 2 windows was a better idea. Good video.. 👍😁👌
@jasongittoes7299
@jasongittoes7299 3 жыл бұрын
Nice easy way of working out fractions have a good week
@WeShowMemes537
@WeShowMemes537 3 жыл бұрын
Awesome lecture about grey area of ventilation
@gazmondo1971
@gazmondo1971 3 жыл бұрын
Thanks for taking the time to do this it's appreciated
@frankdunham6051
@frankdunham6051 3 жыл бұрын
Another great video, thanks Derek 👍
@mohammednazir8307
@mohammednazir8307 2 жыл бұрын
Very helpful video. Thanks again
@ArmstA79
@ArmstA79 2 жыл бұрын
Thanks for this, I've been struggling with internal kitchens for the past 8 years! If the door is big enough can this cover the ventilation requirements alone or does there have to be a window/vent? I was to install a cooker in a kitchen last week that had a conservatory to the rear and a porch to the front and living room off to one side. There were no windows or vents into any of the rooms, combined floor area was probably 36m².
@ltpltp7472
@ltpltp7472 3 ай бұрын
What are the new/amended regs as gas safe have withdrawn all version of TB 005?
@huyongquan6554
@huyongquan6554 3 жыл бұрын
Good work. Many thanks.
@joeanybody9357
@joeanybody9357 2 жыл бұрын
I love the videos but I have to correct a mistake.TB 005(a) I believe says that the extractor fan must be capable of moving 30 litres per second not a minute and 60 litres per second if not adjacent the cooker or hob. My question is if the extractor is connected to a class 1 chimney is that considered as going to outside? My thinking it would very likely not work as the fan would not be powerful enough to force the flumes up the chimney any thoughts.
@Marcus1954s
@Marcus1954s 5 ай бұрын
I just removed a window to get the installer to fit the gas cooker, then reinstalled it when he left.
@Ragnarok14107
@Ragnarok14107 Жыл бұрын
What if you remove the door between the kitchen and conservatory?
@suewarrington8155
@suewarrington8155 2 жыл бұрын
👍 Sue Warrington
@saidhissoufi277
@saidhissoufi277 3 жыл бұрын
Thank you for your video. Always top. Can you tell please where I can download these British standards for ventilation and chimneys. Many thanks
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
You will have to have a look on the internet you might be lucky as we have to pay for the standards
@henrybartlett1986
@henrybartlett1986 3 жыл бұрын
Very useful.
@abchannel3737
@abchannel3737 3 жыл бұрын
Excellent 💐💐
@MrKrzyni
@MrKrzyni 3 жыл бұрын
Got this on my ACS guys 😁
@paul_my_plumbs_uk
@paul_my_plumbs_uk 3 жыл бұрын
I was taught recently at college part F is for FANS
@stevesanders4071
@stevesanders4071 3 жыл бұрын
Very good vid
@joncoke8208
@joncoke8208 3 жыл бұрын
Hi mate have you done a video of how to correctly analsyer a cooker to get the ratios?
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
Yep it’s in how to use an analyser and understand the results
@Loonzartist
@Loonzartist 3 жыл бұрын
For to watch this video a couple of times to understand but thanks
@paulsmith2931
@paulsmith2931 2 жыл бұрын
If you can still get an air vent fitted direct to outside air or a ducted vent to outside air of 100cm cubed wouldn’t that satisfy?
@tomkatgastraining
@tomkatgastraining 2 жыл бұрын
You can use ducted air
@paulsmith2931
@paulsmith2931 2 жыл бұрын
@@tomkatgastraining thanks for the reply
@Loonzartist
@Loonzartist 3 жыл бұрын
Kitchen between 5and10 and haven’t got ventilation with a door direct to outside nil and without a door is 50cm2 right? You said 100 I’m looking in the viper am I wrong?
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
Kitchen between 0 and 5 is 100cm2, 5 to 10 is 50 cm2 but door direct to outside between 5 and 10 no vent required just windows
@Loonzartist
@Loonzartist 3 жыл бұрын
@@tomkatgastraining that’s what I thought I must of heard you wrong
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
@@Loonzartist I have just watched it and I didn’t say it wrong
@gjmheating8857
@gjmheating8857 2 жыл бұрын
@@tomkatgastraining 5 and 10 m3 50cm but 5 and 10 no vent?!?!
@paul_my_plumbs_uk
@paul_my_plumbs_uk 3 жыл бұрын
👍👍👍 Del boy
@M20DAN
@M20DAN 3 жыл бұрын
Tomkat👍🏻
@samchappell233
@samchappell233 3 жыл бұрын
👍👍
@leaturk11
@leaturk11 3 жыл бұрын
This is always a pain in the backside for customers.
@uklifestyle9494
@uklifestyle9494 3 жыл бұрын
👍
@aaronjoyce1980
@aaronjoyce1980 3 жыл бұрын
Just watched Aaron trainee 😁
@hatemmimouni7015
@hatemmimouni7015 3 жыл бұрын
Thank you
@jon-paulward4580
@jon-paulward4580 2 жыл бұрын
Jon-Paul Ward
@buxvan
@buxvan Жыл бұрын
What a weird one !
@georgiecollins9615
@georgiecollins9615 2 жыл бұрын
Callum Collins - Tomkat Training
@SuperWayneyb
@SuperWayneyb 3 жыл бұрын
👍🤓👍
@marcinmasalski4183
@marcinmasalski4183 2 жыл бұрын
Marcin Masalski
@razakhaliq8441
@razakhaliq8441 2 жыл бұрын
Raza watched 22/04/2022
@craighurst3599
@craighurst3599 3 жыл бұрын
CH👍
@mikefahy4960
@mikefahy4960 2 жыл бұрын
Mike Fahy
@gjmheating8857
@gjmheating8857 2 жыл бұрын
I didn't think extractor fan is acceptable means of ventilation it's taking air from room whilst appliance is on
@tomkatgastraining
@tomkatgastraining 2 жыл бұрын
Thinking and knowing are completely different things
Ventilation tutorial for trainee gas engineers PART 1
31:26
Tomkat Gas Training
Рет қаралды 55 М.
Harley Quinn lost the Joker forever!!!#Harley Quinn #joker
00:19
Harley Quinn with the Joker
Рет қаралды 23 МЛН
Magic trick 🪄😁
00:13
Andrey Grechka
Рет қаралды 32 МЛН
Survive 100 Days In Nuclear Bunker, Win $500,000
32:21
MrBeast
Рет қаралды 148 МЛН
ACS Fire Types and their ventilation
9:03
Pass Your Gas
Рет қаралды 2,7 М.
How to diagnose problems on gas stovetop or cooktop hob and how it works.
22:12
ACS Ventilation Made Easy
9:41
Pass Your Gas
Рет қаралды 2,1 М.
ACS Gas Training Ventilation Room Sealed Gas Appliances
12:03
Allen Hart
Рет қаралды 5 М.
Harley Quinn lost the Joker forever!!!#Harley Quinn #joker
00:19
Harley Quinn with the Joker
Рет қаралды 23 МЛН