Total Load Computation

  Рет қаралды 168,717

Jun Aux TV

Jun Aux TV

4 жыл бұрын

Welcome to Jun Aux TV if you enjoy watching this video don't forget to subscribe, like and hit notification bell thank you!
Also visit my FB pages and group:
JB Handyman Services
✓If you’re looking for the right person to fix the problem your facing in your home you can find it here, License Electrical Practitioner is available here, visit us
Jun Aux TV
✓all about Electrical installation and Electrical devices reviews and safety awareness on Electrical
JB Online Shop
✓you can buy product such as Electrical devices mostly on industrial devices
842821366072...
Electrician For Hire
✓group of Electrician looking for a job and giving and taking ideas in one another
JBLyricsVideo
✓its all about lyric video on popular music now a days
Thanks for Watching hope you enjoy. God bless

Пікірлер: 435
@AngkolTV1984
@AngkolTV1984 4 жыл бұрын
New subcriber here!!!Nice video sir dagdag kaalaman to Lalo na sa Amin mga Tesda graduate lng na electrician..more power sir and god bless...pa shout out sa next video mo..salamat!!!
@junauxtv
@junauxtv 4 жыл бұрын
Thank you sir...God bless po..
@leoawag578
@leoawag578 4 жыл бұрын
Thank you po sirJun sa maliwanag mong explaination,
@junauxtv
@junauxtv 4 жыл бұрын
Salamat din po sir
@wkk8835
@wkk8835 4 жыл бұрын
Same computation ng total load and sub branch ang 30sq.m. na studio type apartment?
@rodrigomosqueda1525
@rodrigomosqueda1525 4 жыл бұрын
Tuloy m lang pag vlog nyo sir, hanga ako sa inyo,, bago p lang ak sa channel nyo, ang linaw po ng explaination,,,
@junauxtv
@junauxtv 4 жыл бұрын
Opo sir... hanggang nanjan po kayo handang makinig sakin tuloy2 lng tayo...salamat po
@rubenaledia5706
@rubenaledia5706 4 жыл бұрын
Sir gumagamit na ba tayo ng GFCI/AFCI CB dito sa atin instead of common CB especially sa mga residential wiring?
@jetgamez643
@jetgamez643 2 жыл бұрын
Sir sa computation ba na ito(Area method), pinagsasama ba talaga ung load ng gen lightning at load ng convenience outlet? at pano po madetermine kung ilang small appliance branch circuits ang kelangan ng isang residential house?
@neriomorta5865
@neriomorta5865 3 жыл бұрын
sir,.,ano poba ang kdalasang main circuit breaker sa residential house wiring.,.yung maliit na bahay lang.,.,like mga sampung ilaw,.,na 10 watts ang isa,7 outlet.,.at saka may isang refrigeretor,.,.,.at ilan po ba ang CB ang ilagay dito ?thankyou
@jimdarrendelacruz3732
@jimdarrendelacruz3732 4 жыл бұрын
Nasa pec ito, mga examples. Nice video sir! Thanks for sharing to others. Keep it up po 🙂💯
@junauxtv
@junauxtv 4 жыл бұрын
Yes sir...pangalawang example yan sir...tnx din po
@rtagactac
@rtagactac 3 жыл бұрын
@@junauxtv what page po sa PEC makikita po yung example?
@charlouespaldon8982
@charlouespaldon8982 3 жыл бұрын
Boss tanong lng po.pwd ba maki series ng ilaw sa breaker ng aircon? 20 A sya ang gawing kng ilaw tatlo lng.at yung gamit q 2.0 lng po.hnd ba dilikado? Salamat
@WREVMSTECH
@WREVMSTECH 4 жыл бұрын
Lakasan lang ng loob yan. Gagaling ka rin nyan bro. Ipagpatuloy mo lang yan bro.
@junauxtv
@junauxtv 4 жыл бұрын
Sana sir.... salamat sir ah...
@WREVMSTECH
@WREVMSTECH 4 жыл бұрын
Walang anuman bro.
@29mredwin
@29mredwin 4 жыл бұрын
sir jun pwede kaya yung wala ng main breaker? gamit ko ay 20amp circuit breaker para sa convenience outlet at 10 ampher naman po para sa ilaw.
@withlovemotovlograndomvide107
@withlovemotovlograndomvide107 4 жыл бұрын
Sir magandang hapon! 60Amp Main Breaker Mag jumper po ako ng 30Amp para sa 3 lights,2 Outlet ok lang po ba?
@aglandcebu
@aglandcebu 4 жыл бұрын
Sobrang haba ng video mo pero actually nagbasa ka lang. As a piece of advice, mas maganda rin siguro study your subject matter first before conducting your visual explanation. Lahat ng viewer mo marunong magbasa kaya hindi muna kailangan ipakita paano magbasa ng texts. Mas importante cguro doon ka nakafocus sa expectation ng viewer mo like: paano gagawa ng computation by showing sample computation, ilang load (lightings/convenience outlet) sa bawat breaker, etc, etc. para mas maintindihan masyado kahit sa walng background sa electrical wiring na katulad ko kasi gusto ko lang matuto kahit thru you tube man lang at malaking tulong na rin yon sa akin. But anyway ur effort is much appreciated. hoping this comments here would enlighten or inspire other would be Vlogger to be more concise, accurate and be more detailed in presenting their future videos. Ciao!
@junauxtv
@junauxtv 4 жыл бұрын
Thank you sir...noted po
@julitocm964
@julitocm964 4 жыл бұрын
Sir Maganda yan explanation may natutunan ako
@junauxtv
@junauxtv 4 жыл бұрын
salamt po sir
@jay-armendoza7376
@jay-armendoza7376 4 жыл бұрын
boss okey lang ba kahit mas malaki ang total computation ng Sub Circuit breakers natin sa panel board kesa sa Main Breaker? atsaka ano maging epekto pag ganyan ang set up? maraming salamat boss.more power sa channel mo.
@era1308
@era1308 4 жыл бұрын
interesting po house wiring part 3 ..tamang tama po...salamat mr.electrical
@junauxtv
@junauxtv 4 жыл бұрын
Salamat din po sir
@bobbyfrommindanao4184
@bobbyfrommindanao4184 4 жыл бұрын
Idol, topic mo naman tungkol sa paano pumili ng tamang power generator size at single & three phase load computation. Thanks
@junauxtv
@junauxtv 4 жыл бұрын
soon sir....tnx po sir..
@nyarogaitnas6388
@nyarogaitnas6388 4 жыл бұрын
Mga master katanong lng po sa acu isang 1hp at 1.5hp nagkabit ako ng #10 awg wire tapos ang separate branch circuit breaker dalawang 20 ok lng po bayon kahit malaki ang wire ?sana po masagot salamat
@roelalintv1421
@roelalintv1421 2 жыл бұрын
Good day sir, solid supporter mo ako sa iyong channel, magtanung lang po ako, halimbawa sir iyong floor area Ng bahay nasa 50 square meter lang tapos Ang daming appliances, Sabihin natin na 3 washing machine, 4 na rice cooker, 3 electric fan, Isang Aircon, Ang tanung ko, floor area parin ba Ang pagbasihan? Salamat po sa iyong sagot, God bless
@beberlyngalvez6553
@beberlyngalvez6553 4 жыл бұрын
Maraming salamat talaga na nakapunta ako sa bahay mo...dagdag kaalaman po sir..
@daniloperez5067
@daniloperez5067 4 жыл бұрын
Sir gud pm halimbawa 100amp sa lima 3 r at sa panel board kung no . 2 na wire ano nman sa outlet at ilaw anong pwedeng wire na iinstall na wire.?
@jomarcallos7563
@jomarcallos7563 3 жыл бұрын
gd pm po sir jun itanung q lng po , panu kung hindi namn umabot ang sq.m ng bahay sa 150 o 145 , lessthan 100 , kailangan po ba i times sa 24 or familu dwelling salamat po more power
@ramilyap4501
@ramilyap4501 4 жыл бұрын
Sir sana meron kang website or mga screen shot PEC Documents guidelines para sa mga electricians incase na may plano silang mag wiring sa isang dwelling unit para mayroon silang pagbabasihan at para makita kung pasok pa ang computation nila sa Standard requirements ng PEC. Para mas lalong makatulong sir. Maganda po ang ganyang video para ma well inform ang mga less skill sa computations but they know the hard work.👍👍👍
@junauxtv
@junauxtv 4 жыл бұрын
Meron po sir sa Facebook page pero hindi po lahat soon magkakaroon po tayo ng complete lahat ng mga ginagawa ko at gagawin ko palang ilalagay ko na din po sa KZfaq kaso need nyo po mag join sa paid membership
@seb1553
@seb1553 4 жыл бұрын
@@junauxtv sir e libre muna..hahah
@junauxtv
@junauxtv 4 жыл бұрын
Pambili din yan ng materials sir for our tutorial haha
@seb1553
@seb1553 4 жыл бұрын
@@junauxtv supportahan po namin mga ads mo dito sa yt sir.😁
@junauxtv
@junauxtv 4 жыл бұрын
@@seb1553 malaking bagay yan sir....malay mo sir pag umabot na tayo ng 50k subscriber may paraffle na tayo at modern at high tech na mga gamit ituturo ko sa inyo..sana umabot tayo jan sir...
@heroknaderi
@heroknaderi 4 жыл бұрын
Thanks for sharing I enjoyed it you explained everything perfectly I understood everything you said thanks 🙏
@junauxtv
@junauxtv 4 жыл бұрын
Maraming salamat po sir
@ferdinandresuena2269
@ferdinandresuena2269 4 жыл бұрын
Salamat sayo sir may natutunan ako
@junauxtv
@junauxtv 4 жыл бұрын
Salamat din sir....basta pag may hindi po kayo naintindihan sir... comment lng po kayo... tulungan ko po kayo
@rafaelmejia5505
@rafaelmejia5505 3 жыл бұрын
Sir 3rd class BUILDING WIRING ELECTRICIAN po ako. Anong school po kaya na pwede ko pasukan na kaya ng budget ko to be a MASTER ELECTRICIAN?
@rolandcadiao3973
@rolandcadiao3973 3 жыл бұрын
main line circuit breaker sir ok maba yan sa 2 floor house..
@roderickrecimo5069
@roderickrecimo5069 4 жыл бұрын
boss saan galing yung sub-total na 6480 va. tsaka bakit po di mo sinama yung sa general lighting and receptacle load sa total load
@ryantumangan6573
@ryantumangan6573 4 жыл бұрын
Ohms law lang computation yan sir.....madali maintindihan ng manunuod
@yakult4544
@yakult4544 4 жыл бұрын
Thanks sa video mo, very helpful po. Tanong lang po, saan ba ma babasa sa PEC yong not more than 6 lang na circuits ang kailangan i install sa bahay na merong less than 150sqm floor area?
@junauxtv
@junauxtv 4 жыл бұрын
Page 1046 sir....2017 edition
@ecks347
@ecks347 3 жыл бұрын
@@junauxtv Pano sir kung marami akong ilaw na gusto install sa bahay ko or marami akong loads, it would be more than 6 circuits na. like sa Ref ko, hiwalay ang breaker nyan, motor pump ko, hiwalay, ilaw sa fence lighting, pero nasa 110 sq m lng house ko?
@fernandoagapitojr6361
@fernandoagapitojr6361 4 жыл бұрын
boos gling thx sa information about sa tinuro nyo
@junauxtv
@junauxtv 4 жыл бұрын
Salamat din po sir
@bjorn149
@bjorn149 4 жыл бұрын
master ask ko lang ano po dpat gamitin ko na breaker pag ang appliances ice cream maker 1.7kw blender (2) - 1500w each ref 78w lights 100w.
@junauxtv
@junauxtv 4 жыл бұрын
Base don sa binigay mong load sir may total ka na amps na 21.21...kaya na ng 30amps cb 3.5 wire THHN stranded wire Phelps dodge or Philflex
@TreasureSign2023
@TreasureSign2023 3 жыл бұрын
Gud evening sir Wala po ba kaung vlog about sa mga malalaking wire tulad nang THHN na 250mm or 150mm or 300mm na kapag mabawas ang wire ay Alam mo rin Kung ilang mtrs and natira, salamat po
@tomasteres8296
@tomasteres8296 3 жыл бұрын
General lighting load doesnt include convenince outlets. This class of computation is applicable only for electricians because they dont have the right to design legally.
@cristinemae3073
@cristinemae3073 3 жыл бұрын
Sir! Good evening, pwede po bang mag kabit ako ng mas mataas na ampere kesa sa main breaker?
@roweldeontoy1094
@roweldeontoy1094 4 жыл бұрын
Ayos yan master keep it up
@junauxtv
@junauxtv 4 жыл бұрын
Thank you sir...
@isaganimartin3096
@isaganimartin3096 4 жыл бұрын
good eve new member po.. nxt tym po question po ako. salamat sa tutorial..
@junauxtv
@junauxtv 4 жыл бұрын
Salamat sir....pwd na po kayo magtanong sir no probs po
@hatchiretchistudio5148
@hatchiretchistudio5148 4 жыл бұрын
tanong ko lang po idol pwede po ba yun ' yung load service entrance sa meter na 5.5 mm dudugtungan ko ng #6 na wire papuntang main circuit breaker? Kasi yun po idol ang nkalagay sa load service entrance eh 5.5mm 🙏 sana matulungan nyo po ako idol ,maraming salamat po🙏
@AweRepublic
@AweRepublic 2 жыл бұрын
Hi Sir, Pwedi po bang magpagawa ng load schedule sa inyo? We will pay for your service po.
@benitadagatan6095
@benitadagatan6095 4 жыл бұрын
Thanks sa lessons mo, magagamit ko sa trabaho ko. Puede mag - request? Sana wala ng background music, para madaling mka -concentrate, salamat.
@junauxtv
@junauxtv 4 жыл бұрын
Noted po sir
@domsrequino3865
@domsrequino3865 3 жыл бұрын
boss yung SMALL APPLIANCE LOAD para san yun at anu mga sample na appliances nyan boo...thank you po nag aaral palang ako boss gus2 ko atuto..slamat po
@jeffdelarosa9960
@jeffdelarosa9960 4 жыл бұрын
Master lodi tanung kulang po sana my videos kyu kung gnu kadaming autet at swecsh ang kyng dalhin nang bawat breaker at ung wiring na gagamitin .. bguhan lng po kc ako ..slmat po
@junauxtv
@junauxtv 4 жыл бұрын
Meron na po sir....check mo sir ung ibang video natin...
@viajebyahelang4043
@viajebyahelang4043 3 жыл бұрын
Nice video thumbs up
@xtinct1716
@xtinct1716 4 жыл бұрын
Sir ask ko lng over ba 30 amp na circuit breaker sa isang floor ng bahay?
@junauxtv
@junauxtv 4 жыл бұрын
Depende po sa magiging load nyo sir...if hindi po lumalampas ng 16amps ang load nyo at walang mga special purpose outlet pinapayag po ng PEC na isang breaker lng po...
@GameOP890
@GameOP890 2 жыл бұрын
sir ilan flloor area kapag 2-storey? times 2 ba ng ground floor area?
@aeij91
@aeij91 4 жыл бұрын
Sir ask ko po if need pa ba seperate ang breaker para sa ilaw and c.o?in which case pwede nman as one nalang..ricemill man lang nman
@junauxtv
@junauxtv 4 жыл бұрын
sa standard po sir dapat po hiwalay..
@unavita8158
@unavita8158 4 жыл бұрын
Wag pagsamahin
@sheilaygot4324
@sheilaygot4324 4 жыл бұрын
.master yong sa small appliances na 20amps breaker na may 1500VA nasa pec ba yun?? Or standard naba yun master?? Tanong lng po, salamat master.
@junauxtv
@junauxtv 4 жыл бұрын
As per PEC mam for small appliance 180VA per outlet mam..
@roelalintv1421
@roelalintv1421 3 жыл бұрын
Ask Lang po ako sir, saan po ninyo kinuha iyon 35 percent?
@papajesussaviour102
@papajesussaviour102 4 жыл бұрын
Jun...laki ng pakinabang ng PEC hehehe
@akosipogi23
@akosipogi23 3 жыл бұрын
Boss jun anu ung ginagamit mung book
@joyescarletbagayan6619
@joyescarletbagayan6619 4 жыл бұрын
boss idol ask ko lang sana kung panu ang singilan sa electrical at kung anu anu ang dapat singilin sa electrical sana matulongan mu aq boss idol thanks and godbless
@danteramos7910
@danteramos7910 3 жыл бұрын
Boss kaya ba nang aircon at ref sa 20a?
@sannylozada2114
@sannylozada2114 4 жыл бұрын
Hello sir Good morning. Advice lng sir nakabili q ng panel board s riyadh ang main switch 100 ampere ang circuit breaker 30 ampere tapos nakabili din q ng wire N.H ang size 12 pwede b gamitin s aircon at iba p ang size 14 naman pwede s lahat n ilaw.thanks
@junauxtv
@junauxtv 4 жыл бұрын
Ilang hp ba sir ang aircon mo sir?
@torcrame4183
@torcrame4183 4 жыл бұрын
Mahirapan ata ang vlogger sagutin ang tanong mo dahil kulang ang detalye na binigay mo. Main 100A, at tama dapat malaman muna kung ilan at anong rating ng aircon ang gagamitin mo. Ang mga wire kasi na ginagamit natin at may ampacity rating depende kung anong size ng aircon gagamitin mo.. kung 1HP na WAC ay possible ang nabili mo na 12AWG sa abroad. Isa akong RME.
@junauxtv
@junauxtv 4 жыл бұрын
Salamat sir....
@danilogo235
@danilogo235 8 ай бұрын
Sir jun dapat ang main breaker, para sa akin ay volt on. Para nka seperate ung 6 branches na plug in.
@nielgab2731
@nielgab2731 4 жыл бұрын
alin po ba yung mas updated or latest revision, yung "24 VA/sq.m or 33 VA/sq.m"?
@junauxtv
@junauxtv 4 жыл бұрын
24VA sir
@nielgab2731
@nielgab2731 4 жыл бұрын
salamat
@robertjrsitjar3133
@robertjrsitjar3133 4 жыл бұрын
wala ba magiging poblema sir kung mas malaki ang total ampherage ng mga sub CB kumpara sa main breaker? many thanks po. God bless! and more power.
@junauxtv
@junauxtv 4 жыл бұрын
Wala po sir....tnx din po sir
@shupingyao3885
@shupingyao3885 4 жыл бұрын
Master magkaiba po ba ng circuit breaker ang ref, washing mashine, at outlet ng pra sa oven?
@junauxtv
@junauxtv 4 жыл бұрын
Yes sir as per PEC iba ang sa ranges at laundry mo sir
@shupingyao3885
@shupingyao3885 4 жыл бұрын
Salamat po master sunod yun na gagawin ko😁,, mag ksma kc sa compute ko na 200watts per co ang ref at oven,,, ung aircoin lng nabubukod ko
@jojopenaborja9798
@jojopenaborja9798 3 жыл бұрын
Tanong ko Lang po Kong ang main breaker 60A,service entrance ay #6 pano po yon eh ang service drop #8 ok Lang ba yon?paki sagot Naman po.tnx
@junauxtv
@junauxtv 3 жыл бұрын
Ok lang yan sir...basta from service entrance papuntang bahay yan ang concern natin sir...si power provider na bahala sa service drop
@jerryjavier5899
@jerryjavier5899 4 жыл бұрын
Sir jun ask ko lang, kung ilang amp na cb ang gagamitin sa welding machine
@junauxtv
@junauxtv 4 жыл бұрын
ilang amps welding machine mo sir..
@jerryjavier5899
@jerryjavier5899 4 жыл бұрын
@@junauxtv 300 amps po
@leinx8024
@leinx8024 4 жыл бұрын
Sir, puede bang malaman kung ano table yun 100% para sa 3000 volt-amps, at yun excess ay para sa naman sa 35%..? salamat at God bless.
@junauxtv
@junauxtv 4 жыл бұрын
Demand factor po sir....
@ljcrudz4269
@ljcrudz4269 4 жыл бұрын
boss, yung One branch circuit of "20-ampere", sa video you change it to 15 ampere.. mali po ba yung PEC?
@junauxtv
@junauxtv 4 жыл бұрын
Ako mali jan sir....20 po dapat yan sir...
@ljcrudz4269
@ljcrudz4269 4 жыл бұрын
@@junauxtv ngwonder lang po. . . sana may tutorial using actual na design. kahit isang floor lang. anyways, thank you sa video. malaking tulong po.
@junauxtv
@junauxtv 4 жыл бұрын
Salamat din po sir....
@twilightzone2651
@twilightzone2651 4 жыл бұрын
Ayos lakay!
@rolanballero228
@rolanballero228 3 жыл бұрын
Stepbystep sna boss😊😄
@joelitojrdelacruz978
@joelitojrdelacruz978 4 жыл бұрын
Sir kung 20 amp CB ang gamitin pati Sa mga ilaw it means number 12 na wire gagamitin po?.
@junauxtv
@junauxtv 4 жыл бұрын
Yes sir tama po
@richardmatuguinas2898
@richardmatuguinas2898 4 жыл бұрын
nice sir...napakinabangan mo din...maganda na topic yan...dapat inayos mo ung paliwanag mo.....good job pa din...hehehehehehe
@junauxtv
@junauxtv 4 жыл бұрын
Yan lng kinayanan sir...hahaha.... salamat po sir
@tristan3281
@tristan3281 4 жыл бұрын
Sir jun, ilang amp po ba na circuit breaker para sa 1hp na aircon?
@torcrame4183
@torcrame4183 4 жыл бұрын
1HP @ 230V use 20AT. Why I said it. FLA or Full Load Ampere of 1HP is 8 Amp only, then add the starting current so 20AT is enough.
@junauxtv
@junauxtv 4 жыл бұрын
20AT sir
@hatchiretchistudio5148
@hatchiretchistudio5148 4 жыл бұрын
idol pwede po ba 5.5 mm at 60 amp yung ginamit kong main circuit breaker? Yun po kasi yung nakalagay na load service entrance. kaya po ba yun sa second floor na bahay? Salamat po 🙏
@urstillrighthereinmyheartd7521
@urstillrighthereinmyheartd7521 4 жыл бұрын
Master not allowable ang 5.5mm sa 60 amp n breaker maxado na syang malaki bka sunog na ung wire mo hnd pa nagtitrip ung cb mo.ang 60amp ay pra sa size na 14mm/#6 Pag 5.5 dpt 30 amp lng ikaw ung main cb mo.dpt tugma ang breaker mo sa wire mo pra iwas sunog master.
@hatchiretchistudio5148
@hatchiretchistudio5148 4 жыл бұрын
@@urstillrighthereinmyheartd7521 salamat po idol sa pag advice, tanong ko lang po idol, pwede po ba dugtungan ng #6 wire yung 5.5 mm wire na galing sa metro po? yun po kasi nkalagay papuntang bahay idol hindi din pwede buksan yung metro 🙏 salamat po idol sa pagsagot 🙏
@24thanix
@24thanix 3 жыл бұрын
Pano po sir kung lumampas ng 150 sq.m ang total floor area?
@BISDAK370
@BISDAK370 4 жыл бұрын
Sir pwd papasa ng general lighting load by occupancy at c.o ?
@junauxtv
@junauxtv 4 жыл бұрын
Hindi ko pa napasa sa cp ko sir..pag open ko uli ng pc sir pasa ko sau
@BISDAK370
@BISDAK370 4 жыл бұрын
Ok sir salamat ng marami
@boycircuit6850
@boycircuit6850 4 жыл бұрын
Saan yan pwedi makabili ng panel board idol at magknu
@introvertedsapiophile5255
@introvertedsapiophile5255 4 жыл бұрын
Mas maganda kung maturo mo tlaga yung mga actual load hindi yung rule of thumb.. Kasi pag ganyan pag my dag dag at my circumtances na hindi pasok. Dun magkakamali ka. Pero pag alam mo yung talaga yung logical reasoning kung bakit naging ganyan decision ng pec mas madali mo matatandaan. Kaya kahit ikaw na may binabasa na, still cofused ka pa rin. Kasi na memorize lang yung paano eh solve. Kahit sa demand factor. Rule of thumb yan mga ganyan.
@junauxtv
@junauxtv 4 жыл бұрын
Noted po sir.... salamat po
@emersonulpindorn9725
@emersonulpindorn9725 4 жыл бұрын
Napakagandang video neto sir! Medyu nalito lng aq sa panel board, mei napanood kc aq na nagsabing hindi dapat lumagpas ang total ng sub-breaker sa main breaker. Sa inyu po sir 60 amp ang main nyu na mei limang 20 amp sub na base sa total load computation. So meaning ba neto i can still use a 100 amp main, basta hindi aq lalagpas sa total of 6 circuits? Please enlighten me sir! Thank you in adcance!
@junauxtv
@junauxtv 4 жыл бұрын
Ganto yan sir...may computation para sa main breaker.yan ung kasunod natin na video....hindi ko po alam san nya nakuha ung sinabi nyo po..ang reference ko sir PEC Philippine Electrical Code which is yan yong sinusunod ng mga Electrical Practitioner throughout the Philippines, standard kumbaga.... taposin lng natin ung mga video natin sir...jan malalaman mo sir kung nasa standard ba ang panel board nyo sir
@emersonulpindorn9725
@emersonulpindorn9725 4 жыл бұрын
Ayun! Maraming salamat sir! Malaking tulong talaga eto, at aabangan q series ninyu all the way! Responsibility din kc nating malaman ang tama hindi yung asuming pra sa safety ng lahat. Sir kung pwd sana if mei pag kakataon gawa din kayu video about how to install manual transfer switch para sa backup generator to safely connect sa selected circuit sa bahay. More videos to come po!
@junauxtv
@junauxtv 4 жыл бұрын
@@emersonulpindorn9725 cg sir pag nakabili po ako ng mts sir...ang meron palang tayo sir ATS...ayaw mo ba ng ATS sir?
@junauxtv
@junauxtv 4 жыл бұрын
@@emersonulpindorn9725 salamat sir ah sa pagsupport sa channel natin....tnx tnx
@emersonulpindorn9725
@emersonulpindorn9725 4 жыл бұрын
Jun Aux TV ang nabili ko po kc n generator portable lng which is yung bosco 2300 watts inverter from handyman. Typically designed sa small load lng kaya q namention MTS. Ang nasa isip ko is by using DPDT knife switch to prevent backfeed. I got this idea from this blog myphilippinelife.com/philippine-electrical-wiring/. Cguro pag nakabili nq ng generator that can suport the entire house i will go for ATS.
@marlonestoya1109
@marlonestoya1109 4 жыл бұрын
sir kulang ka last step po..yong total v/a mo i aad mo pa yon sa 25% nang largest motor mo po w/c is aircon...tapos yong sum non divide mo po sa 230v yon na po net v/a mo..tapos computation na po for service entrance..
@junauxtv
@junauxtv 4 жыл бұрын
Hiwalay na video sir...main cb computation po
@ryanjayawitan4551
@ryanjayawitan4551 4 жыл бұрын
Master dapat cinasabi modin kung saan naggaling ung ibang VA kc meron naman table or section na pinagbabasehan nyan...nalilito ang manonood nyan!
@junauxtv
@junauxtv 4 жыл бұрын
Separate ko nlng yan sir...ng video
@coachpepz777
@coachpepz777 4 жыл бұрын
Sir, pwede po bang gamitin na lang yung wattage imbes na va sa total load? Kasi kpag total load e watts ang computation ko o ang ibig sabihin, nalilito kasi ako kapag puro va. Tama po ba ako? Paki correct din ako, thnk you sir.
@junauxtv
@junauxtv 4 жыл бұрын
Volt x ampere= VA sir
@dwanedavid4997
@dwanedavid4997 4 жыл бұрын
Va=watts
@junauxtv
@junauxtv 4 жыл бұрын
May nagsabi sakin sir VA is not equal to watts Watts=VIPf
@doods4301
@doods4301 4 жыл бұрын
@@junauxtv just use watts instead of VA.mga ordinaryong electricians lang ang mga nagtatanong parang madaling maintindihan.
@johnwalterjeminez7856
@johnwalterjeminez7856 4 жыл бұрын
Sir sa PEC sir ung ilaw para sa braeker talagang 20 amphere na ? Binago na ba sir hindi na 15 amp breaker
@junauxtv
@junauxtv 4 жыл бұрын
Either 15amps or 20amps depende sa floor area ng bahay sir...
@dariusbactol4776
@dariusbactol4776 4 жыл бұрын
20amps na po ung updated
@Elmaintenancetv08
@Elmaintenancetv08 4 жыл бұрын
Master tanong ko lang. May isang circuit para sa ilaw, may para sa convenience outlet, sa laundry, at sa air-conditioning? Tama po ba?
@junauxtv
@junauxtv 4 жыл бұрын
Add mo pa sir small appliance
@observeronly
@observeronly 3 жыл бұрын
pwede po magtanong? sobra po taas ng electric bill namin. kalilipat lang po namin dito. dati po konsumo namin hindi tumataas ng 900 pero ngayon po umabot kami ng 3k. ang appliances namin, basic lang. isang 7 cu ft na ref, dalawang computer, 2 electric fan and isang rice cooker na bihira namin gamitin, washing machine na 2x a month lang gamitin. dalawa lang po maliit na kwarto. isang electric water heater na once a week gamitin. wala po kami aircon. dalawa lang po kami sa bahay. wala naman po naka jumper kasi pag pinatay namin yung main switch, patay naman po lahat. hindi po kaya dahil yung wire na naka connect papunta sa metro ay dugtong dugtong at luma na? ano po kaya dapat gawin? 4 months pa lang po kami dito pero umabot na mahigit 10k binabayaran namin. help naman po. salamat
@xtinct1716
@xtinct1716 4 жыл бұрын
Kaya ko natanong ung 30 amp un ung common na ginamit sa mga small houses, ask ko na rin ilang air-conditioning ang kaya ma hold ng 30 amp na circuit breaker kac ung ibang ng electrian 1 / 1 ang set up nila, mali ba un sir?
@junauxtv
@junauxtv 4 жыл бұрын
Pag aircon po sir 1:1 po talaga tayo jan sir as standard depende sa rated ampre ng aircon para don sa ampacity ng breaker na ikakabit sir
@BordzAbyanJumong
@BordzAbyanJumong 4 жыл бұрын
Ganun din napanood ko bro, kay maharlikan channel.. 60 main 30 at 15 ang sub... Sabi nya di dw dapat lalagpas ang sub sa main
@junauxtv
@junauxtv 4 жыл бұрын
@@BordzAbyanJumong iba ung skin sir standard po tayo from PEC 60 main 5 20amps na cb...
@charlsnorveescrupolo1182
@charlsnorveescrupolo1182 4 жыл бұрын
Nkaka CONFUSED yung ganito..may naririnig ako na di dapat lumagpas total load ng sub breaker sa main breaker..pero sa nakikita ko na mga panel lagpas ang total load ng sub breaker sa main breaker...hope this issue will tackle...
@junauxtv
@junauxtv 4 жыл бұрын
Confused ka pa rin ba sir?ang sample na yan sir from PEC Electrical Code...ang Philippine Electrical Code po sir yan po ang sinusunod ng mga PEE,REE at RME...kung sino man nagsabi sa inyo sir tanongin nyo po kung ano or sino reference nya?saan nya nakuha ang computation nya?
@israelvillar3510
@israelvillar3510 4 жыл бұрын
kua jun saan po galing ung 1500va ,bat sya naging computed load nito.
@junauxtv
@junauxtv 4 жыл бұрын
for small load appliance sir 1500va as per PEC
@errikempio9107
@errikempio9107 4 жыл бұрын
Sir, how about assumptions po? may iba kasi na nag aassume ng wattage ng load. For example, 180W per socket, and if 3 gang po sya magiging 540W, at ito na rin ang dinidivide ng 230V. Ito na rin nagiging basehan nila sa wire size at breakers na ginagamit. ano po opinion ninyo regarding dito? advisable po ba sya? TIA po.
@junauxtv
@junauxtv 4 жыл бұрын
Sa code book kasi sir 180va ang per outlet sa mga small load appliance...take note sir small load appliance..
@errikempio9107
@errikempio9107 4 жыл бұрын
Thanks for answering sir. More power po sa channel ninyo.
@rolanballero228
@rolanballero228 3 жыл бұрын
Boss pwed pkilinaw,bagohan pa ako eh😊
@user-we1kr6lh8d
@user-we1kr6lh8d 2 жыл бұрын
Nominal voltage ang 230V?
@jadigumera3110
@jadigumera3110 4 жыл бұрын
Sir ask ko lng 2hp ng ac lan po ba amps dapat na breaker?
@junauxtv
@junauxtv 4 жыл бұрын
20 amps 3.5mm wire sir
@charlesaugust9219
@charlesaugust9219 4 жыл бұрын
30A using 5.5mm². Refer to pec table sa power rating ng mga motor load.
@charlesaugust9219
@charlesaugust9219 4 жыл бұрын
30A @ 5.5mm² Cu wire.
@jubeleoluspo184
@jubeleoluspo184 4 жыл бұрын
Sir paano pag ang size ng Bahay is 25'x21' lang pede naba yan iapply or meron pang another computation?
@junauxtv
@junauxtv 4 жыл бұрын
inches ba to sir?
@jubeleoluspo184
@jubeleoluspo184 4 жыл бұрын
Ft' po yan sir 21×25ft'
@maDDzu
@maDDzu 4 жыл бұрын
sir meron po ba kayong example ng multi family?
@junauxtv
@junauxtv 4 жыл бұрын
Wala pa sir kung magkakaroon man sir baka sa paid membership po natin sir...
@hernandezcarding6
@hernandezcarding6 4 жыл бұрын
Sir, pano po kung 250sqm floor area? Ilang circuit po allowed? Kindly share nmn po reference nito gling sa PEC.
@markmacatuno3218
@markmacatuno3218 4 жыл бұрын
wala naman pong required na circuit. Yung nasa PEC po guide lang yung for safety. Depende napo sa designer at sa client kung ilang circuit ang kailangan. Basta ang priority pag nag dedesign ay safety.
@ruelabanid479
@ruelabanid479 4 жыл бұрын
May vedio kba sir pano malaman na overload na ang isang circuit breaker anu mga test ang gagawin?anu dapat ang mga pamamaraan pra hnd mag overloading..
@junauxtv
@junauxtv 4 жыл бұрын
Wala pa sir...eh...try ko dagdag sa topic na pwd nating gawan ng video sir
@ruelabanid479
@ruelabanid479 4 жыл бұрын
Thank you sir
@ryg9522
@ryg9522 4 жыл бұрын
Kung more than 6-circuits ba ay iba na ang magiging process ng computation? Do you mean kung above 150-square meter na ang area ay mababago ang computation considering residential pa rin or dwelling unit pa rin peru larger lang ang floor area? Sana masagot to avoid confusion Sir
@junauxtv
@junauxtv 4 жыл бұрын
Opo sir kung ang pagbabasihan natin sa computation is total square meter po ng bahay sir..para mas madali sir...total load nlng sir ng mga appliances
@ryg9522
@ryg9522 4 жыл бұрын
Jun Aux TV Sir, if ever mayrun pa akong idagdag na electric range...pwede ko bang idagdag dito as Other Loads? Para masama ko sa pag sum-up sa pagkuha ng Net Total Computed Loads for Main CB and wire sizing for Service Entrance. Yung computation ko ba sa Electric range ay the same sa video niyo about electric range?
@sannysorianojrbat-ao8935
@sannysorianojrbat-ao8935 4 жыл бұрын
Master anung size pvc or rsc gamitin para sa Lo at CO
@junauxtv
@junauxtv 4 жыл бұрын
1/2 sir madalas...pero depende din sa no. Of conductor
@sannysorianojrbat-ao8935
@sannysorianojrbat-ao8935 4 жыл бұрын
Salamat sa pag sagot master.. Ok lang na Pag samahin sa isang pvc ang LO CO para dina ako gagawa pa ng saring pvc pang outlet
@junauxtv
@junauxtv 4 жыл бұрын
@@sannysorianojrbat-ao8935 no problem sir if tingin mo sir hirap ipasok ang wire pwd ka mag 3/4 sir
@ericksonserviano5821
@ericksonserviano5821 4 жыл бұрын
Pwd po sir. Sna un mas malinaw n paliwanag. Ska sna paki actual n lng paano m nakuha sna may calcutalor. Slamat sir.mganda sna kaso diko ma gets maigi slamat sir
@junauxtv
@junauxtv 4 жыл бұрын
Noted po yan sir.... salamat po
@seb1553
@seb1553 4 жыл бұрын
Sir gusto ko makita full installation mo sa buong bahay at ang computation mo yung nasa 2 storey sana sir..thank you po.😊
@junauxtv
@junauxtv 4 жыл бұрын
Matagal pa ung two story sir...hehe... installation muna tayo pero sa wiring board lang ididisccuss lng natin mga important guildlines sa installation ng mga devices and equipment
@seb1553
@seb1553 4 жыл бұрын
@@junauxtv ok po sir, thank you po.
@mhackytario1335
@mhackytario1335 4 жыл бұрын
Sir kapag 2 or 3 story residential, 24 parin ba ang multiplier???
@junauxtv
@junauxtv 4 жыл бұрын
Yes sir basta dwelling sir...
@mhackytario1335
@mhackytario1335 4 жыл бұрын
Okie po tnx
@markinz2162
@markinz2162 2 жыл бұрын
Sir pano po ang computation ng load current ng three face motor.
@ryanignacio105
@ryanignacio105 3 жыл бұрын
San nkuha yun 6480 VA??
@danverlangote9760
@danverlangote9760 4 жыл бұрын
Sa kakamadali mo ang hirap. Mong intindihin.. Walang klaro turo mo
@ronelrayos3720
@ronelrayos3720 4 жыл бұрын
Sir pag nag install kaba ng outlet ng aircon kailangan may sariling circuit breaker yun?? Tnx
@junauxtv
@junauxtv 4 жыл бұрын
Dapat po sir
@ronelrayos3720
@ronelrayos3720 4 жыл бұрын
Ilang amp. Pwede gamitin sa 1.5hp na aircon sir? Tnx!!
@junauxtv
@junauxtv 4 жыл бұрын
@@ronelrayos3720 20amps po sir
@dondonracingpigeonlofttv7463
@dondonracingpigeonlofttv7463 4 жыл бұрын
@@junauxtv ilang aircon na 1.5hp ang Kaya ng 20ams sir?
@junauxtv
@junauxtv 4 жыл бұрын
1:1 po pag aircon sir....1aircon 1 cb
@alvingonzales6895
@alvingonzales6895 3 жыл бұрын
Ano po iyon 6 circuits tinutukoy ninyo?
@ryanmuli0331
@ryanmuli0331 4 жыл бұрын
Sir sana po masagot nyo po kc po nagpatayo ako maliit na bahay Meron po 4 na bulb at 6 na outlet Sabi po 30amp na breaker ang ilalagay at ung wire dw po #10 lahat,ok lng po ba un sir,salamat
@junauxtv
@junauxtv 4 жыл бұрын
20 amps lang sir..mula breaker papunta sa ilaw at saksakan 3.5mm or no. 12, mula sa source mo sir papunta sa breaker 5.5mm or no.10 sir...
@ryanmuli0331
@ryanmuli0331 4 жыл бұрын
@@junauxtv ah cge po sir maraming salamat po
@junauxtv
@junauxtv 4 жыл бұрын
@@ryanmuli0331 welcome po sir.. salamat din po
@torcrame4183
@torcrame4183 4 жыл бұрын
20AT is sufficient to carry the load. 4pcs x 100W = 400VA ( assuming 100w gamit mo ilaw which is malaki na yan) 6pcs x 180VA/outlet = 1,080VA Total = 1480 VA / 230V = 6.43A
@junauxtv
@junauxtv 4 жыл бұрын
Tnx for sharing your thoughts sir...
@oninonion4628
@oninonion4628 4 жыл бұрын
sir pakilinaw lang paano mo nakuha yung 1500 na total load
@victorvillena8908
@victorvillena8908 4 жыл бұрын
How did you convert #12 awg wire to 3.5 (mm)
@junauxtv
@junauxtv 4 жыл бұрын
I just used two types of measurement american wire gauge and metric measurement
@victorvillena8908
@victorvillena8908 4 жыл бұрын
@@junauxtv but according to NEC chart (and other charts) the #12 is 2.05 mm/3.3sq mm. Can you please show us your chart.
@torcrame4183
@torcrame4183 4 жыл бұрын
@@victorvillena8908 PEC equivalent of #12AWG is 3.5sqmm whllst NEC is 4.0sgmm. Since nasa pinas tayo ay we follow PEC. NEC is american standard aneway. Though PEC is copied from NEC.
@mervinlim8028
@mervinlim8028 4 жыл бұрын
@@junauxtv suggestion lang po. Sana sinama mong pinkita ung wire table chart para malaman nila san yung reference ng pagkuha ng wire size based on the computed ampere. Para yung mga newbie t students e hindi magtanong how you ended up on the wire size.
@junauxtv
@junauxtv 4 жыл бұрын
Yes sir meron na po nakapost sa Facebook page natin sir para pwde nila isave or download...tnx sir
General Lighting And Convenience Receptacle Load Computation
9:20
Tamang Size ng Service Entrance Conductor
17:30
Jun Aux TV
Рет қаралды 151 М.
Alex hid in the closet #shorts
00:14
Mihdens
Рет қаралды 11 МЛН
A teacher captured the cutest moment at the nursery #shorts
00:33
Fabiosa Stories
Рет қаралды 7 МЛН
Allowable Ampacities of Insulated Conductors
15:27
Jun Aux TV
Рет қаралды 30 М.
ANO ANG TAMANG MAIN BREAKER SA HOUSE WIRING
19:52
Buddyfroi
Рет қаралды 82 М.
ANO ANG TAMANG MAIN BREAKER.
5:05
SAYDE TV
Рет қаралды 36 М.
Paano mag compute ng TOTAL LOAD para sa MAIN CIRCUIT BREAKER? | Tagalog
10:15
Electrical Pinoy Tutorial TV
Рет қаралды 151 М.
Computation of Light and outlet (tagalog)
9:16
eduard D.I.Y
Рет қаралды 42 М.
Ilang Amperes at Watts ang 1 HP motor single phase ?
18:12
Regie Marinay
Рет қаралды 179 М.
Aircon outlet computation and installation tutorial
14:59
eduard D.I.Y
Рет қаралды 399 М.