Tuning a 2kw diesel heater to run efficiently using a LCD controller

  Рет қаралды 62,508

James Frawley

4 жыл бұрын

This video is designed for people who want to tune their diesel heaters so that they work efficiently and on the correct settings. This is the settings for a 2kw heater.

Пікірлер: 122
@yotagang3705
@yotagang3705 4 ай бұрын
holy jesus you freakin did it!!!! my guy!!!! you have fixed my heater, i have this 2kw heater i cleaned the fxker , changed the glow plug, put in a 200w inverter, cleaned everything and nothing, this bastard starts up on the first time, no smoke, nothing nada, u uave saved me bro thank you so much !!!!!!! u r doing gods work
@Shipfixer
@Shipfixer 3 жыл бұрын
Very good advice and info James. I haven't come across any other videos that specify 2kw or 5-8kw when it comes to setting up the controller. You've saved a lot of headaches for folks. Good man! Instant LIKE. Greetings from Alaska.
@garyclarke5426
@garyclarke5426 2 жыл бұрын
Prior to me watching this vid my heater was turning my garage into a 80's disco with all the smoke but now its great, cheers mate
@nickpritch3152
@nickpritch3152 4 жыл бұрын
At last... Someone's come up with solutions running mint now thank you 👍
@downdroneservices8910
@downdroneservices8910 2 жыл бұрын
Brilliant! Simple easy to follow video. Thank you
@lionelp1944
@lionelp1944 2 жыл бұрын
Finally I found some information on the two kw and exactly what I was wondering about , the settings. I will try that and see how that works. I had been playing around with it and it wouldn't ignite property then I got that problem solved but it was still shutting off after 10 minutes
@jimmyray2008
@jimmyray2008 Жыл бұрын
i’m so glad you made this video. I was having the exact same issues man and you solve my problem. Thanks a lot appreciate the video.
@allanmumby
@allanmumby 4 жыл бұрын
Thanks James, i hope this cures my problem, its a brand new heater and smokes like a coal train. it did come with the old dial up switch, hoping the lcd works better
@Lucentlens
@Lucentlens 2 жыл бұрын
Excellent effort sir - always appreciated! 👍🏽 Related note - all that's happened with these particular settings, is that the heater has in effect been 'detuned' to guarantee full combustion. This is great whilst full combustion & therefore no soot is the paramount concern. However - the heater's maximum temperature has been held back by almost 50% here. Here are the parameters occupying your decision-matrix (& note here that the combustion air intake-rate is literally directly connected to the heater fan speed - so to play with one key parameter (blower speed), directly affects another key parameter (combustion airflow)). So - if you have too little combustion airflow for a given pump speed (fuel-rate), then you will get sooting. This is the same as too much fuel for a given combustion airflow rate. So, both over-fuelling & under-airing the combustion process, will cause sooting. What guarantees no sooting (& also virtually no CO emission)? A definitely sufficient combustion airflow, for a given fuelling rate does. So - why not just whack up the airflow to a 'little beyond' what might be optimal - to guarantee no sooting? Because this will 'blow' on the flame too much, cause it to burn cooler than it could (should) - & this will lead to **higher fuel consumption** (for a given output of heat). And therein lies the trade-off - zero sooting but lower temp & higher fuel consumption. Or - some sooting & max heat available. Of course - you can avoid all of that & tune it with a CO monitor to-hand, & keep an eye on sooting at the exhaust pipe. With that extra effort, you'll be getting the most out of the heater. I learned much of the above from another commenter elsewhere on KZfaq.
@pastorjustin824
@pastorjustin824 2 жыл бұрын
Your confusing as the chinese
@thanh-thomasnguyen7969
@thanh-thomasnguyen7969 2 жыл бұрын
What would the ideal airflow and fuel ratio be? (I can manually test obviously) but just wondering if you knew off the top of your head? Since it’s below freezing here the air is blowing on the fire too much
@Lucentlens
@Lucentlens 2 жыл бұрын
@@thanh-thomasnguyen7969 I'd say a safe & reliable starting point is - lowest pump speed 1Hz, lowest fan speed 1500RPM, max pump speed 5.4Hz, max fan speed 4500RPM. All these are settable within the 'service' menu, of course.
@Lucentlens
@Lucentlens 2 жыл бұрын
@Shep VanDelay This sounds quite plausible, & exactly the sort of thing 'ordinary users' might think of, to dramatically improve a product! 👍🏽👍🏽 (And before anyone says it - no, just because the manufacturer didn't do it, doesn't mean it's not there to be done, with great improvement. Like any manufacturer, they will make the most-profitable product, balanced with quality & efficacy hopefully. Here - we are seeking to completely shift the efficacy part of that compromise).
@Lucentlens
@Lucentlens 2 жыл бұрын
@Shep VanDelay They're fantastic devices, & indeed - the price - such a game-changer! Last I had these, was before any of this (20 years ago), an Eberspächer (Airtronic). That was about £3k fitted, at the time. What I'm happy about now, is that by buying these Chinese diesel heaters - we're not supporting 'counterfeits' or illegal clones. They've just taken an expired-patent scenario & run with it - to fantastic end! Eberspächer & Webasto used to apparently/allegedly collude to keep prices artificially high.
@timcarr4636
@timcarr4636 3 ай бұрын
Thanks for posting this James, top man. I just sorted my 2kw with this.
@johnwood7650
@johnwood7650 Жыл бұрын
Short and sweet. Thanks for this
@anthonylunt4098
@anthonylunt4098 3 жыл бұрын
What a great video I had a lot of trouble this has got me out of .
@george12954
@george12954 2 жыл бұрын
Thanks James. My new heater smokes like crazy also drips diesel from the muffler drain hole. The seller sent me a new glow plug and pump despite me saying they were both tested and working fine. Needless to say no improvement Hopefully a controller reset will fix the problem Thanks again
@Supernice65
@Supernice65 2 жыл бұрын
I’ve had to remove and dismantle my 2kw heater twice after only small use and clean loads of soot out. Beefed up the cable from the rear leisure battery and used your settings. It’s been good as gold since, no smoke at all, running dead clean. Many thanks.
@Guggu3d
@Guggu3d 2 жыл бұрын
You running it in hz or temp mode?
@Supernice65
@Supernice65 2 жыл бұрын
@@Guggu3d Temp mode. Been away the last few days in the van and it’s not been too cold so ran the heater for what it’s meant for, keeping the temp about right in a van space at night. Good as gold on a leisure battery with fridge, lighting and water pump being used.
@Guggu3d
@Guggu3d 2 жыл бұрын
@@Supernice65 Thanks for the reply! Been messing around with it in my car, so far so good! Definitely seems to take a while to get the interior warm and toasty though, ran for 30-45 minutes and only the upper half got warm 😂
@Supernice65
@Supernice65 2 жыл бұрын
@@Guggu3d Shouldn’t be taking that long to heat up. We get hot air within minutes, 30-40 mins and we’re too hot in a LWB converted Ducato van. Are you getting any exhaust or smoke from the exhaust pipe?
@Guggu3d
@Guggu3d 2 жыл бұрын
@@Supernice65 Yeah exhaust temps are good! Core temps are good too, think it's just bad insulated car, because the top half gets toasty and the bottom half is quite cold, if I could route the pipes to blow down at the floor, that should do the trick I believe, warm air goes up and the cold air probably drafts through the door panels. Will take a look today and make sure they're well sealed! 👍😊
@waynecollins6741
@waynecollins6741 3 жыл бұрын
Thanks for that help with everything I needed to know
@petecoventry6858
@petecoventry6858 2 жыл бұрын
Thanks for the video. I am about to instal one in a Mazda Bongo
@longdaynosee
@longdaynosee 10 ай бұрын
THAAAAAAAAAANK YOUUUUUU, OOOOOOOW MYYYY GOOOOD, I COULDN'T MAKE MY HEATER WORK FOR DAYS, NOW IT RUNS SOOOOOOOO SMOOOOTHLY OOOOOW MY GOOOOOD THANK YOU
@leeedwards9043
@leeedwards9043 Жыл бұрын
brilliant mate will try it out. thanks😁👍
@terryedmondson3563
@terryedmondson3563 4 жыл бұрын
good James well explained
@jameshogan2733
@jameshogan2733 3 жыл бұрын
Great video!
@eivindlindefjell5602
@eivindlindefjell5602 8 ай бұрын
Pf = stongness on glowplugg. Thats full power on 6. I use 4. But i have 1.2hz low. Have 3.6hz at topp. Fan speed i have low 2200. High 4500. Fan high can go up all way to last red light goes of. Then back litle so light comes on. Lights have first 2 green. 2 yellow. 2 red in end. Fanspeed can be moved up and down. But all 6 lights have to be on. I think 1hz at low is litle to litle. But if it not clogs up it is ok for you. Have bean using this for years and live in a boat there i use this 24/7 winter time. So after i fine tuned mine 8kw (same same as 5kw ) i did see diesel consume gat waaaaay down. Exteme. I had 5liter tank i cud see then. But Fan speed up and Hz down made same heat, but lower consume on fuel, and alsow lower consume in watt. Start and stopp is not good for this burners. Only use more diesel and very much more fuel. Mine is use 10 12 watt on full speed. But as i told my Hz low is 1.2 high max 3.6hz. And i do regulate Fan speed. Fan speed only blows true house around heater anyway and dont use power almost. And i have bean opening Mine many times. Locking like new inside. If to low at Hz then it can make more carbone inside them say. Best of luck. Good explaining 🎉
@joshsipma623
@joshsipma623 3 жыл бұрын
Wonderful video. Cant wait to try this on mine (I am getting a e08 code for flame extinguished). What size pump do you have?
@bmartinot
@bmartinot Жыл бұрын
Hi, thanks, super helpful. did you only swap the controller or did you need to swap the motherboard too?
@johnmilner6375
@johnmilner6375 3 жыл бұрын
Awsome.
@annelinskill6730
@annelinskill6730 Жыл бұрын
Thanks for all this info, great video. But (and I know this is off at a tangent) but I'm desperate for info on how to set up using the 3 button type LCD switch type. There's ZERO info videos anywhere other than priming the pump. Grateful for any instructions for that
@ericgossger2200
@ericgossger2200 Жыл бұрын
Check out Trail Medic
@hikitech218
@hikitech218 3 жыл бұрын
My small block 2kW came with 'new design' blue round shape LCD controller, Factory settings were 1.7-5.5 Hz and 1600 -4500 RPM. It gives very low C0 readings at tail pipe @1.7 Hz: 10 ppm but at full speed 5.5Hz/4500 CO goes up to 200 or more (10 cm from pipe). I dropped the low end to 1.4Hz@1500 RPM, and it still gives low CO there. The 5.5Hz is probably too much fuel for 4500RPM air.
@3dmixer552
@3dmixer552 2 жыл бұрын
Thats the settings of the 5kw not the 2kw
@hikitech218
@hikitech218 2 жыл бұрын
@@3dmixer552 OK! Do You have the 2kW values ?
@3dmixer552
@3dmixer552 2 жыл бұрын
@@hikitech218 1.2hz 1450RPM 3.2hz 4300RPM. No matter how you set it it will produce more co on High settings. :(
@hikitech218
@hikitech218 2 жыл бұрын
@@3dmixer552 Thanks! I'll try those values. Actually it has been doing fine with the 5 kW factory settings, but I havent'y been running it over 3.5 Hz very much. Too hot in the van....
@3dmixer552
@3dmixer552 2 жыл бұрын
@@hikitech218 Do you have the small 2kw heater or the fake sold 2kw but the same size as 5kw?
@897aa33
@897aa33 2 жыл бұрын
Would they have variable speed according to temp setting or goes on and off? I know webasto ebersprscher does that wonder of chinese is the same? Thanks
@graemewright5827
@graemewright5827 2 жыл бұрын
great video James, thank you, stopped the black smoke instantly. one question though, at low revs my burner makes a whooooo noise, like roaring, it goes away when the revs increase, i've set the low revs to 2500 to overcome this, but still get it at start up and shut down?
@chrisrichardson4992
@chrisrichardson4992 2 жыл бұрын
I had that roaring noise too until I connected the small hose to the combustion air suction port. Made it much quieter.
@searchinglife6122
@searchinglife6122 2 жыл бұрын
good info. i have a 2kw heater. I will be at. High Altitudes. 9-10k ft Would you happen to know the settings for High Altitude ? Cheers
@Anthony-lg6wl
@Anthony-lg6wl Жыл бұрын
Anyone have a list of settings that would work for each model?
@HostileHST
@HostileHST 2 жыл бұрын
Speed Sensor Type There are two configurations of fan speed sensor on the heaters which can be controlled by these displays. Select one or the other according to the sensor type fitted. The original instructions say that if this is set incorrectly then the fan speed is doubled. As ever, select using arrow keys and press OK. It seems that different sensors are used, some with 1 and some with 2 magnets - speed could also be halved I guess! SN=1: If fan has 1 magnet attached to it, to give the RPM signal SN=2: If fan has 2 magnets attached to it, to give the RPM signal
@alexrossmann7672
@alexrossmann7672 2 жыл бұрын
This is incorrect info. Sn 1 vs sn2 has to do with single or double polarity of the magnets. All heaters have two. A good test is to take another magnet and hold it up to your existing fan magnets. One fan magnet should attract the magnet in your hand and one should push it away for the sn1 setting.
@HostileHST
@HostileHST 2 жыл бұрын
@@alexrossmann7672 I was only quoting or sort of quoting what I had read on a forum and as far as the two heaters I have, you are right, both have two magnets. Thank you for the great info mate! BTW, any idea what affect is has on our heaters when that setting is changed? I personally h ave not noticed any difference between the two so curious if there is some subtle affect it may have.
@tnargdonald
@tnargdonald 9 ай бұрын
I run .9 and 1500 for hundreds of hours on my 2kw. What size pump do you have? 22 or 16?
@webbyn
@webbyn Жыл бұрын
Hi James. I have exactly same unit. Works every time once primed and started BUT if I turn the power off for the controller once turned off and back on E-4 code error comes up and I must reprime the pump again. I stopped and started at least 6 -8 times without turning power off perfect results. I have cleaned all contacts, replaced filter, replaced clamps, no leaks. What is the current draw when power is on but unit not running? I have ordered 2 pumps and filters as spares? I may have to leave the power switch on when travelling for the convenience of instant ignition. Are there any alternatives? Thanks Neil
@mingiasi
@mingiasi Жыл бұрын
how well does the 2kw unit do in below 0c conditions?
@lyonscultivars
@lyonscultivars 3 жыл бұрын
I've noticed I can't click the buttons that.fast without having to await the screen to catch up after each click. Any info
@whitevanman9500
@whitevanman9500 4 жыл бұрын
cheers...
@paulshannon1890
@paulshannon1890 4 жыл бұрын
Thanks very much do you recall if had in 15ml or the 22ml fuel pump
@wilvandendoel6782
@wilvandendoel6782 Жыл бұрын
Hi James, these settings are oké if you are using the 0.022 ml pump, there are a lot 0.016 ml pumps supplied with the 2 kw, then settings are rather low, it wil still work but outlet temperature would be low. With the small pump my settings are 4 and 1,3 hz at 4500 and 1500rpm. But it all depends on the power you need, less fuel means less fauling, but don’t go to low, then the heater wil flame out.
@deoranjed8118
@deoranjed8118 Жыл бұрын
On these settings my heater has a little white smoke coming from the exhaust and never seems to light up. I can't feel any heat either end. What did you mean 4 and 1.3 Hz, what's the 4?
@wilvandendoel6782
@wilvandendoel6782 Жыл бұрын
@@deoranjed8118 Did you check your pump size? With the 22 pump your settings are fine. And why use my settings if yours are oké. 4 is 4hz.
@deoranjed8118
@deoranjed8118 Жыл бұрын
@@wilvandendoel6782 I don't know the pump size, I don't think it says. I had the pump the wrong way round, I feel very daft LOL
@allanmumby
@allanmumby 4 жыл бұрын
you beauty, running like a 2kw diesel heater, no smoke or smell. thank you very much, one thing, does the fan have to run at 4550rpm on high or is that the proper settings
@gordonb2011
@gordonb2011 3 жыл бұрын
Allan running the fan at 4550rpm is a little high so you can drop it down to 4300 or 4400 ram. However if you adjust it you may need to adjust your P-3mhz setting as well.
@joedodsworth4301
@joedodsworth4301 3 жыл бұрын
I have a brand new 2kw, chuffs out loads of white smoke fails to start e10, takes four times to start done everything going to it to make it start first time so will try these setting tomorrow
@jamesfrawley7481
@jamesfrawley7481 3 жыл бұрын
Let me know how you get on👍
@joedodsworth4301
@joedodsworth4301 3 жыл бұрын
@@jamesfrawley7481 will do mate, i have had this unit 2 weeks, and always suspected it was over fuelling on start up
@jamesfrawley7481
@jamesfrawley7481 3 жыл бұрын
@@joedodsworth4301 it sounds like it. It's all down to the settings 👍
@joedodsworth4301
@joedodsworth4301 3 жыл бұрын
@@jamesfrawley7481 well mine was already on these settings, all i did was change pf6 to pf5, thats the glow plug temp, then set the fan, and rpm, and it fired up straight away, so mabe the fan apeed helped me out
@enoeno3178
@enoeno3178 3 жыл бұрын
thanks for this. I just came back from a long trip visiting many places and relying on a similar heater for the first time. If you observe the color bars on the lcd, at different altitudes you need different settings. I was worried every time both red bars are on, wasnt sure if it is running too hot. I increased min rpm and lower pump speed for higher alt, andt try to run it with only one red bar. Any thoughts on this anyone? I was told that it auto adjusts for altitude but it doesnt seem that it does so properly. Therefore i was afraid to run it in temperature mode but ran in pump freq mode instead. Is it possible to run these too hot or do they have safety built in?
@HostileHST
@HostileHST 2 жыл бұрын
the two red bars means it's fully up to temp, so that's not a concern, it's needed or something isn't right, aka, takes too long to get to the two red bars, or never does, but ya, full 6 bars is GOOD. Sorry for the edits, late here and very tired, but trying my best, but if its running too hot and the safety's are working, it should stop the fuel pump, so far I have not had this issue, but what can happen, the next day you go to start it, it might be grumpy at first, might start the pump, shut the pump off, but let it do it's thing, might thump hard on second attemp, but shoudl fire up as long as the system is clean.
@MuddyBootz
@MuddyBootz Жыл бұрын
I tuned my heater a similar way but instead of just input figures for high and low frequencies, Iowered them 0.1 each time and repeated this until the 6 burner icons changed to 5. I then added 0.1 to the figures and set these as default. I am now running on 1.3 - 3.6 Hz. 2300 - 4500 RPM. The figures at the end after 12-24v setting is to change the number of magnets in your heater… these can vary depending on model 😊👍🏻
@indi_goexplore9669
@indi_goexplore9669 2 жыл бұрын
Tried my 2kw heater tonight whilst its starting to freeze outside to get an idea on performance before we set off on a road trip to cold places in Europe. Got these settings punched in and I have to admit it seems to run really well although its the only settings I use as I have not long installed it. No smoke and no error codes etc. I put it on flat out and it went from 2.2 degrees to 11 degrees in just under an hour. I have a MWB high top camper decently insulated and opted for the 2kw as most people said the 5kw would be to much, wondering if this is not powerful enough as not sure if its normal to wait so long to get the van warm?? can anyone advise? front of the cab windows are not covered though so I know that would not help! if its 8 deg outside takes about 20-30mins to reach a comfortable 16-17deg.
@flor2543
@flor2543 Жыл бұрын
Just get the most powerful you can fit. If it's too much you can always turn it down, but when cold gets serious you want the big boy.
@steveprice1014
@steveprice1014 2 жыл бұрын
Hi, great video. Don't suppose you know where I can find similar settings for a 5kw heater. Cheers Steve
@ARVIthereyet
@ARVIthereyet 2 жыл бұрын
If you get it, please post here also. Thanks from Estonia 🙂
@Foodmeow
@Foodmeow 6 ай бұрын
Could someone provide a link? I see links for 5kw and 8kw, is it compatible? One review said it did not work for their 2kw.
@lionelp1944
@lionelp1944 2 жыл бұрын
Is there a way to delete the codes. I seem to have the same issue after changing controllers. I get error code 7, 8 + 10
@pastorjustin824
@pastorjustin824 2 жыл бұрын
Is the 1688 your personal lock number or the device number to allow setting changes??.
@goraplx22
@goraplx22 Жыл бұрын
All devices has 1688 as default
@hungpham
@hungpham 3 жыл бұрын
These settings really depend on the fuel pump size and the tolerance of each unit. Show people how to tune, not just copying your numbers.
@jamesfrawley7481
@jamesfrawley7481 3 жыл бұрын
Thanks for your message Hung, your point has been made in previous comments. I don't know the size of the fuel pump but it works for mine. I figure if it works for a handful of people with little or no knowledge of this then I am happy 👍
@jamesfrawley7481
@jamesfrawley7481 3 жыл бұрын
@hung pham. Perhaps you have a video showing people "how to tune"? If so, please share it
@lorrainesankey172
@lorrainesankey172 3 жыл бұрын
Hi I'm trying to get my settings right for 5kw . Do you have a link I can access to find out how to do this ?
@hungpham
@hungpham 3 жыл бұрын
@@lorrainesankey172 I learned a lot on this facebook group: facebook.com/groups/146837062640024. I tuned by sticking a thermocouple from the outside to touch the combustion chamber, keeping the fan speed the same while varying the pulse rate looking for maximum temperature. I also have a CO meter to monitor and minimize carbon-monoxide output. These heaters are apparently shipped with different version of fuel pumps. Some pump out fuel faster than others, so you want to tune for the ideal fuel / air ratio. Most units run fine as arrived, so if your unit runs fine and put out a lot of heat then don't touch it. But if you feel you need to tune it then do your own research and not just copying someone else's setting. IMHO.
@cliffordjava4658
@cliffordjava4658 3 жыл бұрын
Great vid. I have a question. How can I adjust the screen's brightness, if possible? Thx
@compasstrans
@compasstrans 3 жыл бұрын
Not possible
@faffybubs9099
@faffybubs9099 3 жыл бұрын
has it gone dim
@Jestey6
@Jestey6 3 жыл бұрын
The 2 backlight LEDs are wired without current limiting resistors. It is strongly suspected that this allows too much current to flow though the LEDs and over a year they get dimmer and dimmer. There are at least 2 videos showing how to replace them. The alternative is to replace the controller, about £10, of course you will have to do this again a year later, either way is not difficult.
@livinglifemyway7349
@livinglifemyway7349 3 жыл бұрын
Hello , Could you tell me what the diameter is of the outlet port? is it 75mm?
@randydicotti3975
@randydicotti3975 3 жыл бұрын
On TRUE 2kw heaters it is 60mm. If your outlet is larger then most likely you were sent a 5kw heater advertised as a 2kw heater. It is actually a bit harder to find a true 2kw heater.
@irishrover63
@irishrover63 3 жыл бұрын
My heater is a 2kw with those same settings, but my display only shows 2 green,2 yellow and 1 red segment, don't think my heater is throwing out enough heat.
@jwgmail
@jwgmail 3 жыл бұрын
This video kzfaq.info/get/bejne/obWRhK6Xks-Wlmg.html&ab_channel=Italjohn says you can change the glow plug power - that's what the "PF" setting means: "The PF-5 stands for "glow plug 80W. (PF-1-2-3-4-5-6 = 35-40-45-80-90w glow plug power)" So maybe turn that up?
@Enviros
@Enviros 2 жыл бұрын
I believe the "bars" are for efficiency, I could be wrong. Also I've tunes this while it was operating with np. Just some FYI.
@Komfobia
@Komfobia 7 ай бұрын
Do you know the setting for the 8kw full power?
@CS-uc2oh
@CS-uc2oh 6 ай бұрын
8kw is just a 5kw being sold as 8KW. you've been scamed
@extropy1
@extropy1 3 жыл бұрын
Is that the fan or pump noise? I'd rather put a jumper on than listen to that xD
@Gunter8571
@Gunter8571 3 жыл бұрын
Anything on the 5kw?
@ARVIthereyet
@ARVIthereyet 2 жыл бұрын
If you get them, please post here also 🙂
@FreeFinca
@FreeFinca 2 жыл бұрын
Video on Colorado Safaris channel shows the settings for 5kw 👍🏻
@Cementhead48
@Cementhead48 3 жыл бұрын
I cannot access settings on my controller. Same controller as yours. Any ideas? Thanks
@christopherpeary7290
@christopherpeary7290 3 жыл бұрын
I've got the Same problem I have just ordered a new one.
@Cementhead48
@Cementhead48 3 жыл бұрын
@@christopherpeary7290 I ordered another heater with the newer (4 button) controller. I want tobuild a compact portable one. Since mine at least wor,ks good I,m gonna keep mine. Mine only has 3 things to look at. TempC. hz. 1.0 to5.5 which i can adjust. And the battery voltage. Remote works too.
@randydicotti3975
@randydicotti3975 3 жыл бұрын
The problem with many of these units is poor Quality Control. Recently I received a controller with a new diesel heater that was not soldered properly on the board. It was very erratic and often didn't work. After reflowing the solder connections it worked perfectly.
@13yearsaprepperr.jtilbury.51
@13yearsaprepperr.jtilbury.51 3 жыл бұрын
there are 2 controlers that look similar see the big battery symbal at the top right , ONE HAS IT ONE DONT If yours hasnt its the controller you CANT set up ,
@xdickjohnsonx
@xdickjohnsonx 3 жыл бұрын
9009 also works, mine was 1688 and then I paired the key fob controller and the code changed. These are the dumbest heaters.
@garywright8846
@garywright8846 3 жыл бұрын
Great vid, but how did you find the parameters and what are they for different heaters. The instructions are frankly useless.
@tammydavis5511
@tammydavis5511 2 жыл бұрын
Can someone help me out? I have the 5k one ☝️ and it keeps giving me the E06 error Not sure 🤔 what it means? check the polarity of the magnet, the position of the hall sensor or the loose cable clamps Is what the translation is. We’ve checked these they all seem fine everything is level any ideas
@oojimmyflip
@oojimmyflip Жыл бұрын
E-06 says motor failure in my manual. check the plug on the ecu inside the heater cover.
@martinpanks992
@martinpanks992 9 ай бұрын
I hope the location of the heater close to the fridge freezer isn't going to cause the fridge to work harder..
@nixonsmateruby1
@nixonsmateruby1 Жыл бұрын
Why won't my controller do anything that I see on KZfaq?
@captrichgalbraith2553
@captrichgalbraith2553 6 ай бұрын
Perhaps you should put out a printable English version of the operating manual as whoever translated it from Chinese had NO command of the English language.
@marcass100
@marcass100 8 ай бұрын
This way it can run 24/7 no point on and off just keep your window cracked open
@rupertboston4571
@rupertboston4571 2 ай бұрын
Hi, thanks for the info, you say that all 6 lights have to be on, is this only when the heater is on high setting or low as well? I get all 6 lights on when running high, but only 4 lights on the lowest setting, do I need to turn the fan speed down on the low setting to get it hotter?
@wallacegrommet9343
@wallacegrommet9343 3 жыл бұрын
Those thermostats have a short life span
@Michael-it6gb
@Michael-it6gb 3 жыл бұрын
Damn this is a dumb design. What were they thinking? Don't tell me webasto is this cumbersome.
@dansmith6990
@dansmith6990 3 жыл бұрын
Your face is dumb looking too.
@stevepope5484
@stevepope5484 8 ай бұрын
Please dont try operating that simple piece of crap while driving!
1❤️
00:17
Nonomen ノノメン
Рет қаралды 13 МЛН
The child was abused by the clown#Short #Officer Rabbit #angel
00:55
兔子警官
Рет қаралды 24 МЛН
The day of the sea 🌊 🤣❤️ #demariki
00:22
Demariki
Рет қаралды 106 МЛН
1❤️
00:17
Nonomen ノノメン
Рет қаралды 13 МЛН