This video is a step-by-step tutorial on how to install Hive active heating and hot water thermostat including for wiring on S and Y plans and basic set up and testing procedure.
In the video I explain how to quickly and easily replace your existing programmer with your new Hive receiver without the need for any wiring and how to remove your existing wired thermostat and swap 2 wires in the wiring centre to make your new Hive thermostat receiver work.
Chapters of the video:
Music: www.bensound.com
My website: www.urbanplumbers.co.uk

Пікірлер: 152
@jdog3558
@jdog3558 Жыл бұрын
This is the only video I have seen that explains the wiring centre! I was struggling so much with that,but thanks to your video it now works! Thank you so much!
@adamharland7716
@adamharland7716 2 жыл бұрын
Thank you for this video. I was struggling with the hive install as it wasn't clear whether I exchanged the old wireless thermostat or the whole programmer for the hive receiver; you made that clear from the start which was great. The second crucial point you made was the small wiring change in the wiring centre. None of this is mentioned in the instructions so once again thank you so much for sharing this info....Adam
@jackboardman7988
@jackboardman7988 Жыл бұрын
Saved me getting an engineer as hive instructions didn’t include this info. Thanks a lot!
@ben76green
@ben76green Жыл бұрын
Was having trouble with the installation and found this video. It was exactly what I needed, thank you!
@GayorgVonTrapp
@GayorgVonTrapp 3 жыл бұрын
Fantastic, clear , concise explanation at an excellent pace. I found this video extremely helpful. This is what KZfaq is about. Many thanks.
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Glad it was helpful!
@peterdalby7245
@peterdalby7245 Жыл бұрын
Great video but there's no mention of connecting the WiFi box to connect to the app. That would have been nice 👍
@stuartdea844
@stuartdea844 2 жыл бұрын
Great Video, have just installed my Hive in new home using this all working perfectly. Had the white wire with one three way valve 👍
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
Thanks for the comment
@ilovemyvfr
@ilovemyvfr 3 жыл бұрын
Thanks for another great video to compliment your nest installs, I do agree with a previous comment about joining the wires together with a connector at the thermostat end which could be pushed back into the hole in the wall if you are going to position the hive in the same position. This would then leave all the wiring in place should you ever want to go back to a wired set up.
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Yes good idea
@galaxy8818
@galaxy8818 2 жыл бұрын
Want to thank you for this great video, I replaced mine to hive,
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
No worries, good it helped
@shakirhussain2700
@shakirhussain2700 3 ай бұрын
Easy to follow, thanks
@louisrichardson3828
@louisrichardson3828 3 жыл бұрын
Very clear instructions 👍 fantastic job
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Thanks so much 😊
@tahirsiddique5307
@tahirsiddique5307 9 ай бұрын
Great video! Very helpful. Thank you.
@Sweatydave1
@Sweatydave1 2 жыл бұрын
I do a lot of heating installs and this video is a top quality walk through. Well done👍
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
Thanks !
@manjsingh6500
@manjsingh6500 3 жыл бұрын
Really well explained clear n precise
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Thanks a lot
@Mr_Reaper
@Mr_Reaper 8 ай бұрын
Thank you - Worked perfectly
@kelvinellis9155
@kelvinellis9155 3 жыл бұрын
Brilliant video as usual thanks & keep up the good work 👍👍
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Thanks 👍
@buxvan
@buxvan 2 жыл бұрын
Very good & well explained video. Thanks a lot.
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
You are welcome
@hashimanwar243
@hashimanwar243 Жыл бұрын
Fantastic video
@Shandybrother
@Shandybrother 3 жыл бұрын
Excellent video thank you!
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
you are welcome
@thepenetrator2006
@thepenetrator2006 2 жыл бұрын
Finally got mine installed. Called hive as thought I messed up. No matter what the hot water boost button would not work on thermostat or in the app. Ended up a faulty thermostat. It was programmed as a single channel when it was meant to be dual. Screw fix exchanged came back with another and high presto it worked. I could now work for hive after my install ha
@chandreshvarsani2190
@chandreshvarsani2190 2 жыл бұрын
Great video, very easy to understand, please could you make a similar video for Hive multi-zone, eg. Hot Water, multiple CH zones and Underfloor Heating. thanks!
@garyshrimpton1134
@garyshrimpton1134 Жыл бұрын
Very informative
@Yorkshirewild
@Yorkshirewild 4 ай бұрын
Fab Video, Thank you.
@imnotamused
@imnotamused 2 жыл бұрын
Excellent video thankyou
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
Thanks
@manjeetsingh-ec3ki
@manjeetsingh-ec3ki Жыл бұрын
Thank you so much
@rjcraine
@rjcraine 3 жыл бұрын
Great video!
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Glad you enjoyed it
@cyberfingers
@cyberfingers Жыл бұрын
Hi - I love your video. It has given me some confidence to self install the very same unit to my conventional OIL boiler with hot water tank that has the same controller unit as your video (except it has the double size back plate.. . Question - my current set up has as wireless analogue dial type room thermostat so apart from checking the connections on the controller back plate match up is there anything else I need to be aware of ?
@simonmurray2554
@simonmurray2554 3 жыл бұрын
nice and simple, thanks :-)
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
You're welcome!
@chrisliassides7642
@chrisliassides7642 Жыл бұрын
Great Video, well explained with good wiring references. I have a qeuestion: my system has a Standard Hot Water Circuit (with a 3-port Honeywell Valve) and TWO Heating Circuits (Downstairs & Upstairs) that each drive an ON/OFF Valve for the respective area. Would you be kind enough and add any comments of what extra changes I need to do to convert over fully to Hive Smart Heating. Oh! I should I add that there are also TWO Thermostats (one downstairs for the Downstairs Heating, and one upstairs for the Upstairs Heating). Thank you!
@adriatikqypi9356
@adriatikqypi9356 3 жыл бұрын
Great video
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Thanks!
@vernondublin1013
@vernondublin1013 3 жыл бұрын
Thanks for you video. I have a BG model UP2 controller which has a spur off to a BG WR1 wireless receiver. I need to replace with dual receiver as shown in this video. If I were to remove the spurred wire from the UP2 and therefore disregard the WR1, would that be the correct starting point? I only have wires in N, L, 1 & 3 in both units. I hope that makes sense👍🏽
@manofcastle
@manofcastle 3 жыл бұрын
Great video , I have a question can I fix hive with old storage system running with system boiler with only one diverter valve fixed close to the tank .Thanks
@Awobiogun
@Awobiogun 2 жыл бұрын
Thank you for the video. Can I remove the hallway thermostat cable completely and insert a wire link between the terminals from which the brown and black cable has just been removed, so that they are electrically joined together.
@user-bp4yl5yy2q
@user-bp4yl5yy2q 2 жыл бұрын
hi great video ,iv seen a lot of videos on installing hive ,some dont make the wiring correction in the wiring conection box ,they just make sure in the modual the hw on and heating on is conected whats your thoughts on this , also i have a 2 zone house the living room has its own programer ,can i leave it there on it own , so the rest of the house on the hive thank you
@mazikaman4804
@mazikaman4804 2 жыл бұрын
Thanks for your patience.do you give training?
@waheedjalali1618
@waheedjalali1618 10 ай бұрын
Hi I have always been watching you videos they r really helpful Thank u so much I am an apprentice and I want to wire a hive on s plan There are 4 motorized valves . Hot water. Heating. Towel rail.and underfloor heating Could u guide me a little bet on how to wire them thanks
@ianc1097
@ianc1097 Жыл бұрын
Great video. Seems simple enough but I don’t have a thermostat at all. That’s the reason I’m getting one of these. Do I simply need to replace the old control unit with the hub and then just instal the WiFi thermostat. It seems to me to be a simpler installation for me because I don’t need to remove a thermostat. Please advise me.
@BeyondMajestic
@BeyondMajestic 9 ай бұрын
Hi mate, Spot on, did exactly as you showed as I was stuck on the day! Only thing is that I couldn't rack my brain around is that the heating works when requested but when calling for hot water, the boiler is not firing up. Any ideas ??? Replaced ideal classic with Worcester Regular. Existing S Plan with unvented cylinder. Only omitted room stat and linked brown heating valve with programmer call wire. Can't find anything on this issue of hot water not firing up!
@deansharpe6527
@deansharpe6527 Жыл бұрын
Do I need to mess around with wiring centre if I don’t have a thermostat?
@tonyenrico9350
@tonyenrico9350 12 күн бұрын
Just subscribed. Can you please make a video on hive two zones heating
@Cezartravel24
@Cezartravel24 11 ай бұрын
Top man
@rafiahmadzai9442
@rafiahmadzai9442 2 жыл бұрын
Great 👍
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
Thank you! Cheers!
@JEZMAN1971
@JEZMAN1971 3 жыл бұрын
Great video and helped with confirmation of what I was doing as had to rewire a control centre. I need to multizone hive a second thermostat for my underfloor heating, (s plan) it has the zone valve connected to zone 1 at the minute. Can you do a video for multi zone please?
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Yes will do it, good idea!
@anooppatel4818
@anooppatel4818 2 жыл бұрын
Hi When I remove the thermostat from the control panel do I also remove the neutral from the thermostat aswell? And what do I link where the wire that it is connected to in the control panel.
@dominicames9533
@dominicames9533 2 жыл бұрын
My system has a wireless thermostat controlled by a honeywell r6660d, would the process be the same with the call for heat wires and then eliminate all other wires from the Honeywell box ?
@lactobasilio
@lactobasilio 2 жыл бұрын
Hello, great and clear instruction! How about for multi zone? Thanks
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
that is definitely... not coming - LOL
@mattmoloney7746
@mattmoloney7746 Жыл бұрын
I have a Hive installed like you showed currently but want to switch to Nest. I tried mimicking the same wiring for a Nest receiver for my system boiler but it didn’t work, so I had to connect the Hive back up. Is there any additional steps needed when switching from a Hive system boiler setup to a Nest system boiler setup? Thanks!
@manjsingh6500
@manjsingh6500 3 жыл бұрын
Thank you great video. Please please can you do a hive multizone. Installation video. Would help me greatly. Again. Thanks. Urban
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
I don't think I will be doing one anytime soon. Got other projects on the go right now.
@manjsingh6500
@manjsingh6500 3 жыл бұрын
Would it be possible for you to do one one your. Installation board.
@vitalieb.8886
@vitalieb.8886 6 ай бұрын
Hi, you have great videos. Quick question. If a get a Hive V3 heating and hot water, can I wire it to use one channel for a combi-boiler only? Cheers.
@beaugoespro
@beaugoespro 2 жыл бұрын
I am looking at installing Hive but I appear to have an older heating system that does not have an existing programmer, it instead has only a spur which runs direct into the boiler, the temp is then controlled by the radiator TRV's How easy is it to install the programmer on my system ? Assume it could be bridged between the spur and my boiler ?
@MrSpankathon1
@MrSpankathon1 3 жыл бұрын
Do I have to disconnect my old thermostat? We never used it and it no longer seems to have power? Would this impact Hive install in any way?
@RayMurtagh
@RayMurtagh 3 ай бұрын
Hi, I have just purchased and fitted a dual channel HIVE system for my oil fired central heating and it is almost working 100%....but there was no wire behind my old analogue Honeywell controller for water....just 3 wires...L N and the common for live transfer so in effect if I hit the hot water option it just comes on at the switch as I can't heat water separately and never could unless it was the immersion in the hot press. Does this system require additional wiring to the receiver to turn on the immersion? Otherwise am I right in saying that the water option only is redundant? Hope all that makes sense. So when I turn on the heating the oil burner fires up outside and heats both radiators and water simultaneously but I just don’t see anyway of heating water separately with only 3 wires at the controller. Any advice appreciated. Thanks in advance.
@matthews8377
@matthews8377 3 жыл бұрын
Can you do one on how to install a nest. That would be of great help 🙏👍🏼👍🏼
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Check my channel - there are around 5 videos on how to install nest there
@bobwhittaker4433
@bobwhittaker4433 3 жыл бұрын
@@UrbanPlumbers and very good they are too
@amandam8858
@amandam8858 3 жыл бұрын
Hello I have a hot water cylinder/tank and can't control my temperature if I put it on programme/schedule. Any tips. This morning I had luke warm water after I had put it on schedule.
@massimodinoia6627
@massimodinoia6627 2 жыл бұрын
Hi, great video and very well explanatory. My wiring centre is a Honeywell Smartfit it has a circuit board and very few cables going in, would it be possible to install an Hive thermostat? Thanks
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
I am sure it would !
@playid69
@playid69 6 ай бұрын
I have just purchased a new hive hot water/central heating controller with hub & thermostat. Do I need to remove the old manual thermostat? If I wanted to remove it should I just disconnect the wires and terminate them safely? If I do terminate them do I then need to go to the old main controller and disconnect the same coloured wires? I currently have a a Drayton controller and the back box connectors look the same. Does this mean that I can just slot in the new hive controller as it is a 6 pin fitting. I am relatively proficient with electrics but have never installed a wireless system. Thanks
@samjbadhan
@samjbadhan 3 жыл бұрын
Hi thanks for video it’s great, however our thermostat has 3 wires going in and out Honeywell switchboard doesn’t have any wires that are connected together they’re all individual. Can we just disconnect the stat from the wall end?
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
I don’t think I understand your question !
@99thruth
@99thruth 3 жыл бұрын
I ordered by mistake a Dual Channel receiver which doesn`t have COM....but my old thermostat was wired to NO and COM...is there a way to fix it quick?
@jim384
@jim384 2 жыл бұрын
Can you help please. Since installing, heating works fine but hot water cylinder just continues heating, the cylinder thermostat seems to have stopped working. With hot water on all the time should the cylinder stat kick in and override hive?
@antoniogalluccio4213
@antoniogalluccio4213 8 ай бұрын
Can the hive for system boiler be connected to combi as well and you just use the ch feature?
@mutleyuk1794
@mutleyuk1794 10 ай бұрын
Hi - Am i able to use a dual channel on a combi? My boilers being replaced and changed from system to combi.
@miles2home
@miles2home 3 жыл бұрын
hi there thanks for a great advise and training .. i bout the hive thermostat used then i bought the hive hun used from another seller not knowing that it can only be register ones .. is there anyway deregistering the hive hub so new user can register in a new account ? any help would be great thanks
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
I dont know as I never fitted a 2nd hand Hive
@antoniogalluccio4213
@antoniogalluccio4213 8 ай бұрын
And if the oranges from the zone valves were joined into the same elctrical connection,vhow xan a zone valve not cause the other one to open as well?
@Mambo1701e
@Mambo1701e 4 ай бұрын
Have a question in hive multi zone I stallation I am replacing Danfoss TP9000 Programmer Danfoss TP5000SI Danfoss TS2 Sensor I have 2 zones upstairs and downstairs Downstairs was straightforward as the Danfoss TS2 Sensor linked directly to the Danfoss TP9000 Programmer, so all I needed to do was disconnect it and replicate all the other wires in the hive and it works perfectly However the second zone uses the Danfoss TP5000SI and there is no power connected, so I therefore have no power for the hive multi zone reviever Question is where should I get the power from? Will this have to be routed from the boiler control box? Or can this run off a mains or lighting circuit? And I presume I will need a 3 amp spur switch like the main unit?
@benlomax7513
@benlomax7513 4 ай бұрын
If I have hive fitted to a hot water and heating system and replace the boiler for a combi, will that hive system work still or would I need to replace for the heating only version?
@prabchandhok
@prabchandhok 5 ай бұрын
Have a Hive 2, My stat's button has stopped being able to be pushed to select anything. Everything works from the app, I just cant use the dial to select anything the left right turning works. If I want to move it to another property will that still be possible or do I need the push button to work? In that property I dont need to be able tp push it just use the app. Whereas I will get a new one for here. Any advice from someone thats done the installation recently on this stat with the big round push button appreciated, thanks
@timroberts2919
@timroberts2919 2 жыл бұрын
@urbanplumbers if you left the wires as they are in the Junction Box but connected the wires together as shown at the now defunct thermostat end wouldnt that create the same circuit anyway? effectively connecting the two wires together? Great Guide and thank you
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
You can do that, but then you have live wires in a stat that looks like it is no longer used
@balbs11
@balbs11 2 жыл бұрын
@@UrbanPlumbers Agree with UP...you can do that but I would regard it as bad practice - a new owner could redecorate not realising that there are live wires in place.
@amiraziz-music
@amiraziz-music 4 ай бұрын
I have installed hive mini, do I still need the old room thermostat?
@antoniogalluccio4213
@antoniogalluccio4213 8 ай бұрын
So the old programmer was only firing up the boiler on cylinder stat demand as the room stat wires were connected to the common of the programmer? How was the hot water demand separated from the heating demand, how can the zone valves not open each other and give all the time heating and hot water at th3 sake time?
@helenmatfin4842
@helenmatfin4842 2 жыл бұрын
Hello, I am getting constant hot water from my new system boiler which I don't need. Why then has the Hive thermo got a hot water only setting which would indicate to me that I can heat the water up only when I need it. This is frustrating me, can you advise please?
@antoniogalluccio4213
@antoniogalluccio4213 8 ай бұрын
If 3 and 4 are switched lives to ch and hw it means that 1 and 2 are permanent lives but I don't see a link between L,1 and 2 why?
@kgrassek
@kgrassek 2 жыл бұрын
Could You please tell which and how many devices do I need to System boiler with hot water tank, 2 heating zones and UFH? I'm confused with how many HIVE receivers I need....
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
call Hive help line. I am getting lost myself in this system. It can be confusing.
@kelvinellis9155
@kelvinellis9155 3 жыл бұрын
I'm a bit confused on the y plan one can you show hiw to do a u plan with hive please
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Exactly the same just follow the white wire from to 3 port zone valve and connect it to the wire coming from the programmer call for heating
@Mambo1701e
@Mambo1701e 4 ай бұрын
Question. My main control unit has 2 extra wires for remote sensor, they are the same colour as the thermostat so does this mean I don’t need to change any wires in the big wiring box?
@peterbroderick5942
@peterbroderick5942 4 ай бұрын
These will be connected to terminals 5&6 in your existing receiver for the remote sensor ! These will not longer be needed so can be left disconnected ! You wont need to change anything in the central wiring system.
@sally3445
@sally3445 2 жыл бұрын
Where is my wiring centre likely to be. I cant find it!!
@al-azimahmed1188
@al-azimahmed1188 3 жыл бұрын
Great video dude. There is a question I've asked many people but never seem to get a straigt answer, maybe you can help. Im going to install a S paln system in my house. So it will have 1 hot water and 3 heating zones. I'm going to assume that the three heating zones will need there own thermostat, that seems logical enough. But can I hard wire them????? (the house is back to brick and while it's in a state I would like to a avoid using wireless where possible) If I can hard wire them what cable should I run to each thermostat Is 1.5-5 core enough??? Any answers would be great, thanks Do you work in and around London by any chance
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Yes you can hard wire stats. 0.75 is enough. Usually you will need L,N,E + SL so 4 cores are enough but you can run 5 if your want a spare one
@AndrzejPyka84
@AndrzejPyka84 2 жыл бұрын
Hi. So basically you don’t control the hot water temperature? Just on and of am I right?
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
Cylinder thermostat controls how water temperature, hive only sends switched live
@vladimird3575
@vladimird3575 7 ай бұрын
How hot water is working if connected only heating?
@andrewflint1735
@andrewflint1735 2 жыл бұрын
I was wondering for a hive install can I leave the old thermostat on cranked to max (always calling for Central heating and place the hive thermostat somewhere else
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
No you can't. You need to wire Hive receiver in place of existing thermostat wiring in the wiring centre.
@andrewflint1735
@andrewflint1735 2 жыл бұрын
@@UrbanPlumbers I thought you wired the receive in place of the old programmer
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
Apologies - you are correct, thermostat can stay
@larmckenna
@larmckenna 5 ай бұрын
I have the same question. Crank the hallway stat to max so it becomes a normally open switch and use the hive stat somewhere else. My hall always gets hotter than our larger spaces so I want the wireless stat somewhere else. Can you conform this worked in the end as I intend on leaving the wired hall stat in place just dialled to maximum.
@andrewflint1735
@andrewflint1735 5 ай бұрын
@@larmckenna yes mate it works ours still is like that we just leave the old thermostat set to maximum and the hive is on a stand in the living room dead simple as the receiver box on our installation didn't even require a different back plate
@Sukhdeepsaar
@Sukhdeepsaar 3 жыл бұрын
Question, why can’t you just connect the wires together at the old thermostat end?
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
You can but then you have to leave the old stat or wires on the wall.
@Sukhdeepsaar
@Sukhdeepsaar 3 жыл бұрын
Best video I’ve found after months of researching. Well done mate.
@StuHNomadBiker
@StuHNomadBiker 2 жыл бұрын
That's all I did with mine, linked the wires, protected them and left in the wall 👍
@balbs11
@balbs11 2 жыл бұрын
@@StuHNomadBiker Thats ok but a new owner might not realise what has been left behind.
@rognevs5695
@rognevs5695 Жыл бұрын
Brilliant vid as usual
@vladimird3575
@vladimird3575 7 ай бұрын
Don't need wiring for water?
@nigelw4596
@nigelw4596 2 жыл бұрын
I have no wall thermostat will I use the same hive?
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
yes, Hive is RF so no need for any wiring
@superkingpaco
@superkingpaco Жыл бұрын
I have no thermostat. Do I need to rewire anything in the wiring centre? Thanks.
@Will-rq9lw
@Will-rq9lw 7 ай бұрын
Have the same setup. Pity you didn't get an answer 😕
@superkingpaco
@superkingpaco 7 ай бұрын
@@Will-rq9lw I just went for it and turned out to be a really easy install. Just replaced the old programmer in the boiler cupboard with the hive box and that was it.
@eddyjawed4871
@eddyjawed4871 3 жыл бұрын
OK I'm stupid amatuer here dumb question. If black programmer wire is only connected to brown wire from central heater valve, then how does this control the hot water valve?
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Are you saying you have only one wire going from the programmer to the wiring center?
@eddyjawed4871
@eddyjawed4871 3 жыл бұрын
@@UrbanPlumbers Hi, no sorry I gathered from the video that you used the program wire and connected it to the live of the central heater zone/valve. This made me wonder how it is able to then heat the hot water tank because that is a separate valve? Sorry if I'm thick have I missed something. You are great in the video btw, I just have concentration issues lol
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Terminal 3 from programmer connects to cylinder stat and stat fires the zone valve and valve fires the boiler. Terminal 4 connects to heating zone valve directly
@eddyjawed4871
@eddyjawed4871 3 жыл бұрын
@@UrbanPlumbers Thank you so much for explaining that to me cheers
@haribo1468
@haribo1468 2 жыл бұрын
Can it be wired so that it isn’t priority hot water on a Y plan?
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
Y plan is not hot water priority
@haribo1468
@haribo1468 2 жыл бұрын
@@UrbanPlumbers thanks for the reply. I have a hive hot water and heating,fitted on my gravity fed system. It’s a Y plan. When heating gets turned on if the water cylinder isn’t up to temp the 3 way valve stays in the mixed position allowing water and heating, only when the cylinder is up to temp does the valve move to heating only. The problem is the heating can take an age to heat up. Can I stop this? Sorry for the long message.
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
@@haribo1468 Y plan has independent hot water and heating, Just turn hot water off on the hive itself?
@meyerwhite1427
@meyerwhite1427 Жыл бұрын
You say at one point “if you are on a Y-Plan”? Could you explain? I’ve never heard of Y-Plan.
@correctconnection8417
@correctconnection8417 Жыл бұрын
A "Y plan" system only has 1 valve. A 3 port valve. This means the valve can either close off either end or sit mid position. If its mid position then heating and hot water are applied if it sits on one side it supplies heating and if it sits the other it supplies hot water. 3 port valves have 2 extra cores in their flex white and grey. Depending what is energised will depend on where the valve moves to.
@sambilton8114
@sambilton8114 Жыл бұрын
Can you do one for combi?
@UrbanPlumbers
@UrbanPlumbers Жыл бұрын
no, you should not be opening the boiler up yourself.
@aliatas6647
@aliatas6647 3 жыл бұрын
How do you decommision a thermostat with 4 wires from the wiring center? This video shows only 2 wires connecting to thermostat
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
If you have 4 wires those 2 additional ones are earth and neutral. Just disconnect both ends or terminate safely at thermostat end
@aliatas6647
@aliatas6647 3 жыл бұрын
@@UrbanPlumbers will the 2 additional wires (neutral and earth) trace back to the wiring center ?
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
Yes
@aliatas6647
@aliatas6647 3 жыл бұрын
@@UrbanPlumbers thanks man. I appreciate it👍🏻
@lucianogambino7987
@lucianogambino7987 3 жыл бұрын
Can I controll the thermostat in the way I can only use myself by my phone my tenant thy keep the temperature high with window open even when is summer, Please help
@UrbanPlumbers
@UrbanPlumbers 3 жыл бұрын
I would rather not answer this question.
@pasgas12safe58
@pasgas12safe58 3 жыл бұрын
@@UrbanPlumbers 🙈😂😂👍👍
@phil_jc_dev
@phil_jc_dev 2 жыл бұрын
Same as all other videos. Very flaky in the wiring on the receiver. Just say you don’t know how to do it.
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
Show us your video then mate
@user-if4qd2ol7d
@user-if4qd2ol7d Жыл бұрын
The information about proving a circuit safe to work on is incorrect. First test your meter on a known live circuit or proving unit. Secondly, test the circuit you wish to work on. Thirdly re test your meter on the known live circuit or proving unit. Then and only then can you be certain the circuit you wish to work on is dead. Your meter could have failed following proving on the initial test. From an authorised person for LV and HV systems
Best Toilet Gadgets and #Hacks you must try!!💩💩
00:49
Poly Holy Yow
Рет қаралды 21 МЛН
Каха заблудился в горах
00:57
К-Media
Рет қаралды 9 МЛН
Эффект Карбонаро и нестандартная коробка
01:00
История одного вокалиста
Рет қаралды 10 МЛН
Hive Active Heating and Hot Water Thermostat - Review
3:37
Lee Thompson
Рет қаралды 45 М.
How To Install A Hive Smart Thermostat - Combi Boiler
14:22
ToolBox Talk For Electricians
Рет қаралды 3,1 М.
How To Use Your Standalone HIVE Thermostat - Pro-Tect Heating & Plumbing Ltd
11:42
Pro-Tect Heating & Plumbing Ltd
Рет қаралды 125 М.
How to Wire an S Plan Heating System
20:19
Boiler Boffin
Рет қаралды 51 М.
Hive Active Heating Y Plan Installation
11:16
Hive Home
Рет қаралды 21 М.
Hive Controller Features
3:15
LCD Heating & Gas Services Ltd
Рет қаралды 73 М.
Best Toilet Gadgets and #Hacks you must try!!💩💩
00:49
Poly Holy Yow
Рет қаралды 21 МЛН