No video

Walk in freezer getting warm

  Рет қаралды 3,976

Curious HVAC Guy

Curious HVAC Guy

Күн бұрын

What the heck is going on here, I'm back at this same location for a very similar issue
Please consider subscribing to my channel and follow me below
Social Media
Facebook www.facebook.c...
Instagram / curioushvacguy
For any inquiries please contact me at
curioushvacguy@gmail.com

Пікірлер: 17
@Brisket9392
@Brisket9392 Жыл бұрын
That evap looks real nice. Guessing the original one was leaking from the coil and got replaced. I would have thrown a peanut on this one. We back in the low 30s in Michigan. LOL.
@Matthew456E
@Matthew456E Жыл бұрын
"Summer time has finally arrived" lol back in the 50s, low 60s for high.
@mekyleavacadogaming7354
@mekyleavacadogaming7354 Жыл бұрын
Sounds like a Monday call
@kurtweck2276
@kurtweck2276 Жыл бұрын
So here's an old school rule we usta use, this is so old I'm taking r12, r22, r502 stuff and it always worked with condenser fan cycling switches. What ever pressure corresponded with 105' F you set the switch to close at 25# over, and open at 5# under. Fan cycling causes head pressure to swing up and down, not good for can compressors. Gives them a short life. That compressor your working on looks like an old Copeland semihermetic. Those things were nearly bullet proof . I've seen those flipped upside down on a roof from the wind and were still running and maintaining temp.
@shine-cg9uf
@shine-cg9uf Жыл бұрын
❄️💪🇺🇸👍 tough times in restaurant biz. Maybe just swap out fcs b4 fall /winter. 404a is a blend n they can show bubbles n during low load conditions.
@bigdaddy4975
@bigdaddy4975 7 ай бұрын
Anytime there’s a hot box a load on the box the sight glass will flash until that temp comes down to around 45 degrees
@oldmetalguy4577
@oldmetalguy4577 Жыл бұрын
All this Waygu talk has me wanting a steak.😀
@amadeusrocks4967
@amadeusrocks4967 Жыл бұрын
wago connectors do pop apart sometimes. have had issues with them
@markcotter2355
@markcotter2355 Жыл бұрын
good job. I enjoyed the diagnostic. That is a crusty old B. hopefully they will upgrade soon.
@winkhvac62
@winkhvac62 Жыл бұрын
I have a call back on wego connector
@R290s_biggest_fan
@R290s_biggest_fan Жыл бұрын
Wouldn't the efficiently be greater at night with a lower temp liquid?
@analogmoz
@analogmoz Жыл бұрын
Wagyu nuts are for effete technicians. I am an effete tech.
@jasonjohnsonHVAC
@jasonjohnsonHVAC Жыл бұрын
Put an ICM fan speed controller on it. Much better than off/on. Nothing is as good as a headmaster though. Just a thought.
@bigdaddy4975
@bigdaddy4975 7 ай бұрын
Give it 15 mins or so
@juan251100
@juan251100 Жыл бұрын
How do you like that adjustable wrench? I’ve seen them but hesitant to buy them.
@HVACRNorth
@HVACRNorth Жыл бұрын
🤘🙌
Walk in freezer not running
20:56
Curious HVAC Guy
Рет қаралды 6 М.
Quick emergency calls
22:53
Curious HVAC Guy
Рет қаралды 9 М.
ISSEI & yellow girl 💛
00:33
ISSEI / いっせい
Рет қаралды 22 МЛН
الذرة أنقذت حياتي🌽😱
00:27
Cool Tool SHORTS Arabic
Рет қаралды 20 МЛН
OMG what happened??😳 filaretiki family✨ #social
01:00
Filaretiki
Рет қаралды 13 МЛН
DIY Cascade Refrigeration System (Part III)
13:12
Hyperspace Pirate
Рет қаралды 108 М.
HURRY THE BEER WALK IN COOLER IS TOO WARM
27:59
HVACR VIDEOS
Рет қаралды 38 М.
Carrier AC Fan not spinning
16:45
Let's fix stuff!
Рет қаралды 3 М.
Air Conditioning isn't free... but we're close.
25:45
Tech Ingredients
Рет қаралды 1,1 МЛН
Lots Of Work To Do!
35:25
HVACR Survival
Рет қаралды 31 М.
Walk in freezer gets warm
17:39
Curious HVAC Guy
Рет қаралды 4 М.
No AC in the Kitchen, please help
19:42
Curious HVAC Guy
Рет қаралды 6 М.
TXV TROUBLE, ICE ON EVAPORATOR, HOW TO ADJUST THE TXV?
10:29
leckyjake
Рет қаралды 184 М.
How To Maximize Your Bosch Heat Pump Performance
14:30
Tim DeStasio HVAC
Рет қаралды 2,1 М.
June 7, 2022
28:39
Curious HVAC Guy
Рет қаралды 7 М.