What's involved in a Boiler Service?

  Рет қаралды 144,279

Village Heating

Village Heating

Күн бұрын

Here's one of our engineer explaining all about Boiler Services and what they do during a Boiler Service.
We work all over London and surrounding home counties, give us a call on 020 8102 9898 to enquire about a free quotation.

Пікірлер: 105
@pjezdik3591
@pjezdik3591 3 жыл бұрын
Handy to also check the Gas Rate and Expansion vessel pressure when cold.
@richardthorpe1741
@richardthorpe1741 2 жыл бұрын
I have never seen any two people do the same service testing. The way they get done depends on which way the wind blows I think.
@justsendmelocation5068
@justsendmelocation5068 4 жыл бұрын
why have you removed the combustion chamber case when doing the FGA?
@andyrichards4802
@andyrichards4802 5 жыл бұрын
We carry out a Safe isolation before touching the boiler, and check it has a 3amp fuse, then carry out the service according to manufacturers.
@zLiies
@zLiies 3 жыл бұрын
just commented this, thank you. it is a part of the service
@kelvinellis8312
@kelvinellis8312 5 жыл бұрын
How did you use that manometer without a reducer I've got one & the hose you used is too big for it
@whome5810
@whome5810 2 жыл бұрын
@Village Heating Great video! When you stick the probe into the flu to do the combustion analysis does the probe go into the exhaust part of the flu only? But when you test the air intake of the flu does the probe come out of the exhaust and go into the air intake part of the flu only?
@zLiies
@zLiies 3 жыл бұрын
Am new to the gas world but isn't safe isolation a part of the procedure
@JakeMadz
@JakeMadz 3 жыл бұрын
Do you not need the front case on to check Air quality?
@conorbreakwell9689
@conorbreakwell9689 5 жыл бұрын
No working pressure and standing pressure at the meter? Also no operating pressure? Or no Gas Rate...
@Kingkongkirk1234
@Kingkongkirk1234 2 жыл бұрын
case should be fitted when carrying out FGA and clean condense trap after cleaning burner
@tnt9861
@tnt9861 2 жыл бұрын
Can I ask how u used to TESTO to carry out tightness test.. do you just connect it & read figures ? I have bought one but can’t find any tutorials
@michaelbegley5548
@michaelbegley5548 6 жыл бұрын
As a heating & gas engineer for 18 years this is terrible glad I didn't do my training where this guy did his !
@ahms8689
@ahms8689 5 жыл бұрын
How long wojld you say a standard service for a combi boiler would take?
@sarunassurvila7857
@sarunassurvila7857 3 жыл бұрын
@@ahms8689 I would say about 1,5 hours.
@steventhomson2104
@steventhomson2104 2 жыл бұрын
@@sarunassurvila7857 1.5 hours for a standard service?? No chance!
@sarunassurvila7857
@sarunassurvila7857 2 жыл бұрын
@@steventhomson2104 how long according to you?
@steventhomson2104
@steventhomson2104 2 жыл бұрын
@@sarunassurvila7857 Providing your flue gas analysis is within tolerance etc, a service should be around 30 minutes on a combi. If you have to clean the heat exchanger or anything additional, then slightly longer, but a standard service would be around 30 minutes easily. Strip down service would be longer but would only be done according to Mis. 1.5 hours for a service is wild. I'd be sacked if I took that long.
@steroy69
@steroy69 2 жыл бұрын
Which manometer is he using? Looks a hand size
@AdrianBordoy
@AdrianBordoy 6 жыл бұрын
Didn't carry out electrical safety checks how do you know the boiler wasn't live? You should always check the vessel make sure it's charged at 0.8 bar Analyse with the combustion door on not off
@mrbachittarsingh9243
@mrbachittarsingh9243 6 жыл бұрын
Sniff the knickers when checking rads
@kb5057
@kb5057 5 жыл бұрын
what a load of shit. Always check vessel. Non of us carry nitrogen, granted, but air is better than fuck all if its empty...@PlumbRevs
@superwhites5870
@superwhites5870 5 жыл бұрын
bob bob yep how the fuck did he miss that one 😂😂🤣🤣🤣🤣
@farobenz6144
@farobenz6144 4 жыл бұрын
You are doing servicing not fixing
@sarunassurvila7857
@sarunassurvila7857 3 жыл бұрын
@PlumbRevs you are so incorrect about not needing to check vessel
@lance4613
@lance4613 5 жыл бұрын
No standing or working pressure test at the boiler gas valve inlet either ?
@zuriskable
@zuriskable 4 жыл бұрын
I thought that
@TheHairyHound
@TheHairyHound 4 жыл бұрын
How many "First of all" 's can you have? I would think only one 🤔
@waheedjalali1618
@waheedjalali1618 4 жыл бұрын
Thats what i noticed ;;; About 4 times first of all 🤔
@mob9334
@mob9334 Жыл бұрын
Every plumbing video I watch, in the comments it's just other plumbers slagging their work off. Worries me as I'm looking to get work done.
@AmerKhattabMujahid
@AmerKhattabMujahid 4 жыл бұрын
No Gas rate check?
@jaxmar88
@jaxmar88 6 жыл бұрын
Are you allowed to use a digital manometer now for soundness testing ?
@dee6962
@dee6962 3 жыл бұрын
Why would you not ? Just curious as I've just bought the same unit
@dzmalekvali1110
@dzmalekvali1110 6 жыл бұрын
Check your expansion vessel air charge , flow /return temp deferential, air intake with fga while appliance on for back flow, 20. air or 19.9, boiler safety cut out..flue termination..ect I worked for village heating...rubbish
@bolajieletu6165
@bolajieletu6165 6 жыл бұрын
Mel Makavali VILLAGE HEATING ARE SHIT COMPANY AND NOT ORGANISED
@dzmalekvali1110
@dzmalekvali1110 6 жыл бұрын
Rubbish what should the air intake be?? Have you checked the seal on the burner plate? Have checked the termination of the flue? Gas Pipe sleeved or not?
@proteus1
@proteus1 5 жыл бұрын
Mel Makavali perhaps you should show us how it's done.
@davidbrown7988
@davidbrown7988 4 жыл бұрын
DZ Malekvali he also most crucial thing I think he never electrically tested the boiler or meter to begin with he touched the boiler without testing if it is live a lot of engineers have died due to this
@sarunassurvila7857
@sarunassurvila7857 3 жыл бұрын
@@davidbrown7988 can you tell us more about this?
@jamesives1
@jamesives1 4 жыл бұрын
Where did you get the gloves from, they look very practical
@harryonthetop
@harryonthetop 3 жыл бұрын
Black mamba...toolstation
@heatz2484
@heatz2484 3 жыл бұрын
Do you have to replace the burner seal if you open it ?
@pjezdik3591
@pjezdik3591 3 жыл бұрын
Not on the Baxi Potterton range
@factorclassic
@factorclassic Жыл бұрын
these are all gas safety & combustion related tests. How about boiler efficiency test, would be nice as part of annual service. Efficiency is degraded because of scaling inside heat exchanger, particularly in hard water areas. Now the question is, why is descaling not part of regular service then? Some would call it maintenance. Couple of hours of boiler descaling plus system power flush would certainly extend boiler life, reduce chances of sludge blocking diverter valves, pressure sensors, air vents etc. Not to mention magna filter cleaning which should be part of service anyway.
@dee6962
@dee6962 3 жыл бұрын
You didn't change the burner seal after removing
@slider3215
@slider3215 3 жыл бұрын
its good practice
@tomaszignielnicki4320
@tomaszignielnicki4320 3 жыл бұрын
My gas boiler service took gas engineer approx 5 minutes.Charged me 40 pounds.Am I missing something here? or next time should I show him FIRST THINGS FIRST what to do?
@thecarpetman7687
@thecarpetman7687 3 жыл бұрын
Well then all he did were readings and didn’t check expansion vessel, safety valve or pressure test while running….if your boiler is going over 3 bar then you may need to get the expansion vessel re- pressurised and the Safety valve checked.
@jongraham8751
@jongraham8751 4 жыл бұрын
Bet this lads a laugh on a night out!!
@hakimvlogs6579
@hakimvlogs6579 6 жыл бұрын
Do you have to open the burner to check it? Someone told me that when doing a boiler service you only have to open the main heat exchanger and do a strip clean every 5 years
@25007kris
@25007kris 6 жыл бұрын
On A rated boilers or premix burners if you like, you decide based on your analyser test! If combustion is ok and gas rate spot on then no need to take that burner off! Regardless of years!
@simonharper4199
@simonharper4199 2 жыл бұрын
Viessmann insist on a burner strip/clean annually (replace seal every 5 years) regardless of readings (and clean stainless exchanger with a soft cloth (never polish it! -looks wonderful but this introduces micro scratches on the metal which increase its surface area and life expectancy) and vinegar. Vaillant always used to want a burner strip annually . Had a customer who had a new patio laid in the winter. This combustion chamber was covered in indian sandstone dust that had been sucked in from outside
@dzmalekvali1110
@dzmalekvali1110 6 жыл бұрын
VHL are rubbish...worked with them short cutting alot
@gang-gang8325
@gang-gang8325 4 жыл бұрын
Is it easy being a gas engineer
@kryptoniteee
@kryptoniteee 5 жыл бұрын
First thing? For how many things lol
@bigdave1493
@bigdave1493 6 жыл бұрын
Wow that was terrible!! You shouldn't analyse a boiler with the case off also if the burner is removed the graphite seal must be changed
@tarquinbiscuit-barrel5871
@tarquinbiscuit-barrel5871 6 жыл бұрын
Yep, you can't check the integrity of the flue if the burners taking it's air from the room!
@tarquinbiscuit-barrel5871
@tarquinbiscuit-barrel5871 6 жыл бұрын
But not all boilers need a new seal when the burner is removed, just fit a Viessmann!
@25007kris
@25007kris 6 жыл бұрын
Spot on Big Dave Must have comb chamber cover on to check air intake Absolutely no need to disturb that G10 if you’re first analyser test passes! Just making all others look bad cause now customers will think it’s a must... Terrible video
@jaxmar88
@jaxmar88 6 жыл бұрын
Thats not the combustion chamber cover, its the balanced compartment cover which also need to be fitted when you analize appliance.
@fulwell1972
@fulwell1972 6 жыл бұрын
I just watched a video of a cockney geezer promoting an extended bi annual service his firm does on vokeras. Apparently the manufacturers instructions aren't necessarily wrong but they're not right because of blah blah blah, it looks like they strip the bloody things down and replace stuff that don't need changing. I'm torn between them just being old school or just taking the piss, I'll go for taking the piss..... If said cockney geezer was a doctor he'd have ignored my test results which indicated I was fine then replaced my perfectly good liver... I paid a tidy sum for my analyser and if says that boiler is running fine I don't mess with it..
@dionisienatea3137
@dionisienatea3137 5 жыл бұрын
I checked the expansion vessel, controls, gas rate, ignition and detection electrodes and was fine. i like the way this guy checked the air intake and flue integrity with the case open. But as said on 4:00, this is a typical service.
@user-zb1iu5io1u
@user-zb1iu5io1u Жыл бұрын
Can’t this just be used by criminals to break into cars (and houses)?
@aghasahib4703
@aghasahib4703 5 жыл бұрын
Burner graphite seal needs to be replaced everytime you service a boiler but he did not.
@Urban_Revert
@Urban_Revert Жыл бұрын
Not required on every boiler.
@sammiejane6241
@sammiejane6241 4 жыл бұрын
Woo he's cute 😍
@lilyclarke5985
@lilyclarke5985 6 жыл бұрын
Not changing the seal whattttt??
@dzmalekvali1110
@dzmalekvali1110 6 жыл бұрын
List is long
@manofweed1
@manofweed1 6 жыл бұрын
I had to buy a crap boiler like this last week, after my 38 year old boiler had a rubber seal that perished. Of course all the thieves in the trade joined the resounding chorus of.................It's obsolete mate !..........So 2500gbp down for want of a rubber seal.
@25007kris
@25007kris 6 жыл бұрын
Well after 38 years it’ll be hard to find parts especially rubber as even sitting on a shelf they go brittle in that long a time, also nobody wants to pay the time engineers invest in searching for something that might not be out there any more. Talking from experience! And lastly on cast iron heat exchangers you’ll have to drain your most likely open vented system as the isolation valves will be seized as well and you’ll pay for a whole days labour for a gas engineer and still have a E rated boiler with less than 50% efficiency! They have done you a favour by replacing it!
@manofweed1
@manofweed1 6 жыл бұрын
There you go. Wouldn't find anything like that nowadays. Just put in a new bulb yesterday, today it's blown !
@manofweed1
@manofweed1 6 жыл бұрын
Ok, two bob.
@manofweed1
@manofweed1 6 жыл бұрын
Of course it's dangerous without that seal. You sound like one of those low grade heating bods.
@jaxmar88
@jaxmar88 6 жыл бұрын
I cant think of many 38 year old boilers that had rubber seals in the flueways, yes rubber seals on waterway joints & manifolds etc, what make/model was it?
@paulkramer2599
@paulkramer2599 4 жыл бұрын
Let me try to help you as someone who has worked in the gas industry for many years..............If you are testing the Air Intake of the flue for products of combustion on a Room Sealed appliance you will need to have the Combustion Door ON and SEALED !!........If not then the test is absolutely pointless as the boiler will pull it's combustion air from the point of LEAST RESISTANCE......i.e. THE ROOM !.........If you are Still struggling to understand this then maybe you should be looking for a new career in something that will not endanger people's lives !!
@justsendmelocation5068
@justsendmelocation5068 6 жыл бұрын
Young man, there's no need to feel down I said, young man, pick yourself off the ground I said, young man, 'cause you're in a new town
@Jumpeyuk
@Jumpeyuk 4 жыл бұрын
There's no need to be unhappy Young man, there's a place you can go I said, young man, when you're short on your dough You can stay there, and I'm sure you will find Many ways to have a good time
@KpopLabPro
@KpopLabPro 2 жыл бұрын
Other than cleaning out the little pot with deposit is really nothing, £80 for visual inspection and having couple of tools plugged in does seem like a rip off tbh
@mob9334
@mob9334 Жыл бұрын
That's why I serviced my boiler recently after 4 years, engineer said boiler all good lol
@Bilal-wj7bh
@Bilal-wj7bh Жыл бұрын
@@mob9334 you should be gas engineer registered to service it first thing Second thing did you knew how to do tightness cumbusion ,pressures tools and stuff ?cos If you dont do it right this can create carbon monoxide which could result in death worst case scenario Third thing abut price I agree with you it should be around 50 and your boiler strips down and most engineer clean it properly unlike some out there And also we go through 4 year graft to get the qualification not that easy otherwise you won't see a shortage and plenty of work out there you don't pay it they go somewhere else don't matter
@dannyhoey9856
@dannyhoey9856 Жыл бұрын
I can see Gas Safe pulling them Up for this………. Remove the burner but not replacing the seal, testing for back syphon products of combustion with the burner door open? No gas rate to see if the appliance is over / under gassed. No electricity check to see if appliances is safe, check to see if 3 amp fuse, to protect boiler and PCB. Co Alarms list goes on, no LDF after gas testing. No expansion vessel pressure check.
@ragingbearbull
@ragingbearbull 7 жыл бұрын
Excellent presentation. Pity the condensate trap & burner are clean. Pity you aren't using an Anton or Kane analyser. and run through the tests. Never seen the one you were using.
@mrsayef1059
@mrsayef1059 6 жыл бұрын
Christian Pereira exactly my thoughts as well lol
@stephensmith5648
@stephensmith5648 6 жыл бұрын
Testo I think.
@paulkramer2599
@paulkramer2599 6 жыл бұрын
Nothing wrong with Testo mate....German engineering......Just the guy using it ! LOL
@geotj58
@geotj58 5 жыл бұрын
NOT WORTH COMMENTING ON IT'S SO BAD, BUT I WILL , NO ELECTRICAL TESTS, WHY REMOVE BURNER IF CO/CO2 IS OK AND NOT REPLACE SEAL, NO FAN FAIL CHECK, NO LOSS OF WATER CHECK, NO IGN CHECK, NO VESSEL CHECK, NO SOUNDNES TEST ON BOILER AFTER REMOVING BURNER , DIDN'T CHECK FLUE TERMINATION, DIDN'T CHECK CORRECT 3AMP FUSE, AND IT GOES ON MORE LIKE VILLAGE RIPOFF
@justsendmelocation5068
@justsendmelocation5068 6 жыл бұрын
More like Village people!
@twigthewonderkid1
@twigthewonderkid1 6 жыл бұрын
Village Idiot
@bolajieletu6165
@bolajieletu6165 6 жыл бұрын
Sorry mate How did you get your job. You seriously don’t know how to service a boiler. Let me correct you if your employer can’t Anytime you break into combustion must replace the seals G10 and more also you can’t removed the case of a boiler and used flue analyser your reading will be wrong.
@afifuddinh
@afifuddinh 5 жыл бұрын
Adib malas tgk, dia dh bijak
@mrbachittarsingh9243
@mrbachittarsingh9243 5 жыл бұрын
muhamad afifuddin my thoughts also
@vincentneale2620
@vincentneale2620 3 жыл бұрын
Don`t get SSE they are crap
@slider3215
@slider3215 3 жыл бұрын
Village Idiot Heating...no safe isolation, no working pressures, gas rate, no checking operation of FSD.
Boiler sequence of operation
5:24
CP Utility Solutions
Рет қаралды 17 М.
How To Service Your Boiler
2:16
Deco Bliss
Рет қаралды 75 М.
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 62 МЛН
Spot The Fake Animal For $10,000
00:40
MrBeast
Рет қаралды 165 МЛН
Alex hid in the closet #shorts
00:14
Mihdens
Рет қаралды 13 МЛН
You Won't Believe What This Boiler service uncovers! THIS WILL SHOCK YOU
14:14
Blue Bulldog Plumbing
Рет қаралды 17 М.
Boiler Service - Ideal - Baxi - Worcester Bosch - Vokera
8:13
Allen Hart
Рет қаралды 28 М.
Vaillant Boiler Service - Plumber
11:20
Allen Hart
Рет қаралды 44 М.
Vaillant Boiler Service (Hertfordshire)
14:36
Boiler Boffin
Рет қаралды 34 М.
What should a gas Boiler Service include? 🔧
9:33
Gas Angel Heating
Рет қаралды 11 М.
Worcester Bosch Boiler Service - Leeds Plumber
19:22
Allen Hart
Рет қаралды 53 М.
Worcester Bosch Greenstar 8000 fitted after a full system conversion!
16:23
Hartley heating and plumbing
Рет қаралды 34 М.
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 62 МЛН