Why suction line diameter is bigger than discharge line diameter in centrifugal pumps? (Part - 3)

  Рет қаралды 45,106

Core Engineering

Core Engineering

Жыл бұрын

In this video we are going to discuss about the ;
Why discharge line diameter of centrifugal pump is smaller than the suction line diameter?
Why is the discharge pipe diameter of a centrifugal pumps smaller than the suction pipe diameter?
Why diameter of discharge line is smaller than suction line in centrifugal pump
Discharge line size in centrifugal pump
Why suction line is bigger than discharge line in centrifugal pump?
suction or discharge line bigger?
What is the difference between suction line and discharge line?
Why is pump inlet bigger than outlet?
Centrifugal pump sizing
Pump sizing
Centrifugal Pump Series:
• Centrifugal Pump Series
Industrial Pump Videos:
• Industrial Pump Videos
Process Engineering Series Videos:
• Process Engineering
Industrial Engineering Series:
• Industrial Engineering
Unit Conversion Series:
• Unit Conversion Series
Instrumentation Engineering Series:
• Instrumentation Engine...
Engineering Shorts Series:
• Engineering Shorts
#CoreEngineering #centrifugalpump #pump #engineering #refinery #powerplant
About the Channel :
Core Engineering is a KZfaq Channel for those Engineering Students, Engineers i.e. Chemical Engineer, Process Engineer, Instrumentation Engineer, Mechanical Engineer(those who are already working in a Industry) who want to learn about the Engineering Concepts from the scratch, want to know the WHY behind the every concept and those chemical engineers, Process Engineer, Instrumentation Engineer as well as Mechanical Engineer who are already working in a Industry. I would like to try to upload the videos related to Industrial concepts i.e. heat exchangers, valves, reactors, plant shut down and plant start up, process safety during plant startup and shutdown and process engineering related videos. Therefore You may Subscribe the Core Engineering KZfaq Channel and our other social media handles.

Пікірлер: 64
@Coreengineers
@Coreengineers Жыл бұрын
Watch Industrial Engineering videos 👇 kzfaq.info/sun/PLrqNx2OqGF51_BYmmF_z2TrR2x0EkVH3z
@sen-ow7ub
@sen-ow7ub Жыл бұрын
The concept you have mentioned about the pipe in this video was amazing and you have made various videos like this.
@saudagarkumar6193
@saudagarkumar6193 Жыл бұрын
Informative video....👍
@darshanajoshi118
@darshanajoshi118 Жыл бұрын
Today my concept got cleared thank you!
@tesusinha6038
@tesusinha6038 9 күн бұрын
Now finally clear my doubt ❤
@anilpal5947
@anilpal5947 9 ай бұрын
Most knowledgeable video thanks for sharing valuable knowledge
@Sarchitta
@Sarchitta 9 күн бұрын
i have a doubt, Q=AV, then how throttling valve controls the flow, please clear my queries.
@louzazaza3819
@louzazaza3819 Жыл бұрын
Available and required? Not related to the reel npsh without the dead volum?
@texture6
@texture6 Жыл бұрын
I love the way you start to explain in simple terms then jump to trigonometry. Then you come back to simple terms and jump back to calculus. All over the spectrum with one brush stroke
@chandrasekharviswanadhuni9591
@chandrasekharviswanadhuni9591 2 ай бұрын
😮
@ashishsharma2375
@ashishsharma2375 Жыл бұрын
Bro really excellent video.
@Coreengineers
@Coreengineers Жыл бұрын
thank you ashish!
@darshanajoshi118
@darshanajoshi118 Жыл бұрын
How recycle line impact the pump performance please make one video about it
@AhmedRamada1995
@AhmedRamada1995 9 ай бұрын
Amazing explanation Can you make a video about which is greater losses in suction line or discharge line for pump Thanks
@Coreengineers
@Coreengineers 9 ай бұрын
sure! I will upload that video soon
@ReactionBabuOfficial
@ReactionBabuOfficial 2 ай бұрын
Pressure is inversely prapotional to area hota he
@rajendrapatane5712
@rajendrapatane5712 Жыл бұрын
Pressure is inversely prepositional to area 😊
@atifjamalmsstudentmechanic8330
@atifjamalmsstudentmechanic8330 10 ай бұрын
It is for solid not for fluid
@auslinasirtn-7434
@auslinasirtn-7434 8 ай бұрын
How about diaphragm actuators..say Shutdown valve air actuated where pressure inverse proportion to area applies...with less area force is more thereby u can actuate such a huge valve 30 inch valve too
@chemicalengineer1985
@chemicalengineer1985 Жыл бұрын
Good explain
@Coreengineers
@Coreengineers Жыл бұрын
thanks dear
@sumitkatkar2019
@sumitkatkar2019 Жыл бұрын
NPSHa is difference between suction pressure and vapour pressure of pumping fluid at that temprature provided by process engineer during pump sizing and NPSHr is provided by pump vendor. NPSHa > NPSHr to avoid cavitation due to vaporization of pumping fluid which is caused due to frictional loss between source tank to pump suction as a result suction pressure falls below vapour pressure and cavitation occur.
@ammar2140
@ammar2140 7 ай бұрын
why NPSHr (from vendor) is have to be smaller than NPSHa (calculated by process engineer), shouldnt it be the higher the difference of suction pressure and vapor pressure, the less the cavitation will occur?
@anilpal5947
@anilpal5947 9 ай бұрын
Sir request to you please upload about mechanical seal of reactor and pump seal
@sen-ow7ub
@sen-ow7ub Жыл бұрын
We kindly ask you to make all your videos piping related and as far as possible you must post at least one piping related video per day.
@affanbhaijaan65
@affanbhaijaan65 Жыл бұрын
But if at discharge, velocity is increasing then as per bernoulli eqtn the pressure will decrease at discharge, will it not cause back pressure sir....
@Coreengineers
@Coreengineers Жыл бұрын
No It'll not create back pressure as pump is used to increases the pressure of the fluid and at suction side we increase the dia because of cavitation prevention. For back pressure we use the nrv btw
@AzmiGameTV
@AzmiGameTV 9 ай бұрын
what if suction head is 1", then enlarged to 2" using a reducer, and then back to 1" when connecting to pump, then goes out of the pump at 1"?
@moganapriyaav1281
@moganapriyaav1281 Жыл бұрын
Could you please explain about end of curve operation of pumps
@Coreengineers
@Coreengineers Жыл бұрын
Will upload the video soon!
@NIRAJKUMAR-xu6yw
@NIRAJKUMAR-xu6yw Ай бұрын
But in some cases suction and discharge are equal in size.
@chemicalengineer1985
@chemicalengineer1985 Жыл бұрын
Make turbine related topics information sir
@Coreengineers
@Coreengineers Жыл бұрын
yes! I'm planning about it
@stiker3852
@stiker3852 5 ай бұрын
If area increases pressure decreases
@fearlessandflawless..9254
@fearlessandflawless..9254 Жыл бұрын
When area increases pressure increases????
@rajendrapatane5712
@rajendrapatane5712 Жыл бұрын
Pressure is inversely prepositional to area
@selvamaniselvamanitechian8431
@selvamaniselvamanitechian8431 Жыл бұрын
Very
@TULSIPAINTS64
@TULSIPAINTS64 8 ай бұрын
Is there any formula between suction dia and discharge dia
@Coreengineers
@Coreengineers 8 ай бұрын
Will cover in upcoming videos
@ardaizzet5
@ardaizzet5 11 ай бұрын
thx for the video but how come when A is increasing the P is increasing??
@Coreengineers
@Coreengineers 11 ай бұрын
Please watch bernaulli's principle videos
@harshptl1
@harshptl1 9 ай бұрын
this video is misleading. Increase in area lead to decrease in pressre drop.
@TheHaimoud
@TheHaimoud Жыл бұрын
I think that the NPSH is the sum of the pressure head and the velocity head in the suction of the pump minus the Vapor pressure of liquide .so this sum is still constant if we applie Bernoulli equation so the variation of npsh it’s from aspiration pressure losses that’s why we use bigger diameter to reduce the velocity only
@nagmanikushwaha7448
@nagmanikushwaha7448 5 ай бұрын
How areas increases then pressure increases.
@Coreengineers
@Coreengineers 5 ай бұрын
See please refer Bernoulli equation I completely understand your point.
@vanzmendiola5358
@vanzmendiola5358 Жыл бұрын
What would happen if the suction line is smaller than the discharge line? Suction line is 3" and discharge of pump is at 2 1/2" but a reducer is used so it becomes 4".
@pankajpatel5121
@pankajpatel5121 Жыл бұрын
Pls explain
@GALLARAJESH-yn2xu
@GALLARAJESH-yn2xu Жыл бұрын
If Area will increases, then pressure will be decreases...
@Coreengineers
@Coreengineers Жыл бұрын
Please relate here with bernaulli's principle not P=F/A, A increase Velocity decreases then P increases
@GALLARAJESH-yn2xu
@GALLARAJESH-yn2xu Жыл бұрын
Tq❤
@suvendusukla5307
@suvendusukla5307 3 ай бұрын
Sorry,bro if area increase then Pressure will be decrease.
@afnangillani5243
@afnangillani5243 2 ай бұрын
No, you're wrong it's vice-versa
@letslovenature6701
@letslovenature6701 Жыл бұрын
@core engineering : Sir are you sure that Area increase then pressure increase? If it is so than kindly answer that area of 8" pipe is higher or 6" pipeline . I am surprised that people are still comments nice explanation and all. What you explain is totally wrong. If area increase then pressure decreases that's all.
@Coreengineers
@Coreengineers Жыл бұрын
Don't get confused , simple thing is here …..according to Bernoulli's equation when we increase area so pressure will increase. For example we all use water pipe to give water in garden so In this situation we push a pipe so water will fastly go as far away, Hence when we push pipe it means we are decreasing area of pipe so pressure will decrease and velocity will increase.
@letslovenature6701
@letslovenature6701 Жыл бұрын
@@Coreengineers Dear sir, Yes now you are correct that if area decrease then pressure increase. Kindly review your video because in video what you are explaining is totally Opposite. That's why I comment. Bernoulli equation is right and I am not confused but kindly check what you explained in your video. You will come to know that in video you explained wrong.
@manishankarraju5354
@manishankarraju5354 Жыл бұрын
your point is right when considering a pressure of liquid at rest(P=F/A),but in motion always pressure is directly proportional to Area.(As per bernoulis Law)
@stefanvalchev8066
@stefanvalchev8066 Жыл бұрын
@@manishankarraju5354 in rest pressure is the same everywhere.
@stefanvalchev8066
@stefanvalchev8066 Жыл бұрын
@@letslovenature6701 mate u are very wrong.very very wrong.this video is legit .and you are very wrong
@nasibur1
@nasibur1 3 ай бұрын
Very narrowly missed the concept. By your logic if you directly suck water from a reservoir, pump will not cavitate.😅😅😅
@pranali6meshram707
@pranali6meshram707 4 ай бұрын
Npsha- npshr =1
Alex hid in the closet #shorts
00:14
Mihdens
Рет қаралды 11 МЛН
50 YouTubers Fight For $1,000,000
41:27
MrBeast
Рет қаралды 190 МЛН
A clash of kindness and indifference #shorts
00:17
Fabiosa Best Lifehacks
Рет қаралды 115 МЛН
PIPE SIZING | LINE SIZING | EXAMPLE | HYDRAULICS | PIPING MANTRA |
12:37
Cavitation in Centrifugal pump, NPSH available, NPSH required, Calculation of NPSH, NPSH3
14:18
CENTRIFUGAL PUMP PIPING LAYOUT | PART-1 | PIPING MANTRA |
9:15
Piping Mantra
Рет қаралды 40 М.
Pump Piping Stress Analysis - Centrifugal Pump Piping Design
8:27
PipingStress
Рет қаралды 10 М.
Advanced Process Control - Minimum flow control for centrifugal pumps
7:10
WR Training Contact
Рет қаралды 22 М.
Alex hid in the closet #shorts
00:14
Mihdens
Рет қаралды 11 МЛН