Once again perfectly explained nice and simple thanks as always
@BoilerMend2 ай бұрын
My pleasure! 😌👍
@user-li8gr8ur8l3 ай бұрын
Thank you that was very helpful hopefully this will help going forward
@BoilerMend3 ай бұрын
Hi you're very welcome 🫶
@raul8358 ай бұрын
Brilliant vid
@seanb-ol3up8 күн бұрын
Great video mate 👍
@BoilerMend8 күн бұрын
Thanks 👍
@b1h2u3p48 ай бұрын
Nice explanation.
@waseemkhaliq9338 ай бұрын
You could also do a short circuit test at the board to the fan gas valve pump etc
@BoilerMend6 ай бұрын
🫣
@mrnsp50138 ай бұрын
Good video Phaji
@jonathanwhitlock51865 ай бұрын
Top man thank you , I got same problem 😊
@BoilerMend5 ай бұрын
No problem 👍
@BoilerMend5 ай бұрын
🫶
@Carl-re6zb8 ай бұрын
A good sign of the transformer blown is the smell it gives off. I strip old boilers and have a large stock of parts which saves the customer a new boiler or expensive parts.
@garethdavid78278 ай бұрын
This happened to me . Worcester said needed new board and transformer. Got reconditioned one for £6 . Saved my customer a fortune
@charliewillis85278 ай бұрын
Happens a lot on the Ri could have saved your fuses I always look at that first on them strongly it never normally damages the pcb I just change the transformer