[YANMAR] Alarms and Trips Testing of Auxiliary Engine | Marine Engineering | Technical Vlog : 096

  Рет қаралды 5,429

MOE MYINT SHEIN 🇲🇲

MOE MYINT SHEIN 🇲🇲

5 ай бұрын

(1) Overspeed trip
(2) Jacket Water High Temperature Alarm
(3) Fuel Oil Leakage Alarm
(4) L.O low pressure alarm
(5) L.O low pressure alarm and trip
(6) Priming fail alarm
(7) Manual emergency stop
Such safety alarms and trips testing can be seen in this video.
#marineengineering #overspeed #marineengine #auxiliary
More Videos for Auxiliary Generator Engine 👇
AUXILIARY GENERATOR ENGINE
• AUXILIARY GENERATOR EN...

Пікірлер: 36
@user-ve1lw7qq4p
@user-ve1lw7qq4p Ай бұрын
Thanks a lot ! Great job!
@MoeMyintShein1987
@MoeMyintShein1987 Ай бұрын
Welcome !
@ashishmishra2144
@ashishmishra2144 5 ай бұрын
As always, thanks for all efforts 🙌👌
@MoeMyintShein1987
@MoeMyintShein1987 5 ай бұрын
My pleasure ! Please share to your marine engineers friends. Thanks.
@ashishmishra2144
@ashishmishra2144 5 ай бұрын
@@MoeMyintShein1987 Sure sir, will do the same. This is really a nice channel for a practical insight which is not given in book. Will definitely share. One suggestion from my side- If you keep interacting with people by coming yourself in camera, it will create much more impact and will increase more subscribers. much love from india
@user-nf3me5wj4u
@user-nf3me5wj4u 5 ай бұрын
Thank you Sir for sharing knownledge
@MoeMyintShein1987
@MoeMyintShein1987 5 ай бұрын
Welcome !
@thihakyawswar2274
@thihakyawswar2274 4 ай бұрын
thanks brother
@MoeMyintShein1987
@MoeMyintShein1987 4 ай бұрын
Welcome !
@rupanjansaha4788
@rupanjansaha4788 4 ай бұрын
VERY NICE ..
@MoeMyintShein1987
@MoeMyintShein1987 4 ай бұрын
Thank you, Saha 😊
@zbihgtv9864
@zbihgtv9864 Ай бұрын
Next boiler sir. Thank you for your video.
@MoeMyintShein1987
@MoeMyintShein1987 Ай бұрын
Many Boiler Videos On My Channel. Appreciate.
@AshiqHussain-lo1ph
@AshiqHussain-lo1ph 5 ай бұрын
Did all alaram tested while running the generator ?
@MoeMyintShein1987
@MoeMyintShein1987 5 ай бұрын
Except F.O Leakage and Manual Emergency Stop. (Prefer Man. Emergency Stop to be tested while engine is running.)
@ashishmishra2144
@ashishmishra2144 4 ай бұрын
Hey sir, What is the suction and discharge pressure that we usually maintain in sewage vacuum pump for 30 people STP ?
@MoeMyintShein1987
@MoeMyintShein1987 4 ай бұрын
Did you mean vacuum setting for Vacuummarator in Vacuum Toilet System? Clarify.
@ashishmishra2144
@ashishmishra2144 4 ай бұрын
@@MoeMyintShein1987 Sir, suction pressure, I got , cut-in we do: - 0.4 bar vacuum and Cut out we do: -0.55 bar vacuum for pressure switch. But what is the discharge pressure of sewage vacuum p/p to STP that we usually maintain?
@MoeMyintShein1987
@MoeMyintShein1987 4 ай бұрын
@ashishmishra2144 One side of the pump is vacuum (negative pressure) and other side of pump is positive pressure. 😊
@ashishmishra2144
@ashishmishra2144 4 ай бұрын
@@MoeMyintShein1987 yes sir, I understood, but what positive valve we usually maintain !!
@MoeMyintShein1987
@MoeMyintShein1987 4 ай бұрын
@ashishmishra2144 Discharge Pressure of Vacuumarator Pump to STP (or) other points is maximum 0.3 Bar. Depends upon capacity (m3/hr) of Pump, discharge pressure (back pressure) can differ, slightly.
@ashishmishra2144
@ashishmishra2144 5 ай бұрын
Hey Sir, what is suction pressure and discharge pressure of aeration blower that we maintain in STP ?
@MoeMyintShein1987
@MoeMyintShein1987 5 ай бұрын
I didn’t see any suction pressure gauges for aeration blower. Depends upon Model of Plant, discharge pressure varies. In general, between 0.015MPa and 0.02MPa. For 15 to 25 persons, it is around 0.015MPa. For 40 to 65 persons, around 0.02MPa.
@ashishmishra2144
@ashishmishra2144 5 ай бұрын
@@MoeMyintShein1987 Sir since it is sucking engine room air. so its suction pressure should be 1 bar, is ths correct ? and thus discharge pressure should be more than 1 bar , but as you said discharge pressure is 0.015-0.02 Mpa which is less than 1 bar.. This thing i do not understood
@MoeMyintShein1987
@MoeMyintShein1987 5 ай бұрын
@ashishmishra2144 That’s right ! It take suction from Engine room. Not much pressure is required for aeration of bacteria. If air pressure is higher, overflow can occurs and also fault high water level alarm can activate. If air pressure is high, force acting on each side of plant is high. (Ref. Pressure = Force / Area.) Safety valve is fitted and set at 0.025MPa for Discharge 0.02MPa blower. Pressure drops because of passing suction filter with silencer and design of impellers that are used in blower.
@ashishmishra2144
@ashishmishra2144 5 ай бұрын
@@MoeMyintShein1987 Okk sir, i got. Sir as suction pressure gauge is not fitted but whenever aeration blower is taking suction of engine room air, then at the time of suction- is this thing sure that suction pressure will be in negative value ?
@MoeMyintShein1987
@MoeMyintShein1987 5 ай бұрын
@ashishmishra2144 Correct !!! Suction is negative pressure. That’s why you palm gets sucking from silencer when you touch.
GENERATOR TROUBLESHOOTING, NO STOP OPERATION
9:53
leckyjake
Рет қаралды 29 М.
Самое Романтичное Видео ❤️
00:16
Глеб Рандалайнен
Рет қаралды 6 МЛН
Final muy increíble 😱
00:46
Juan De Dios Pantoja 2
Рет қаралды 53 МЛН
WHO LAUGHS LAST LAUGHS BEST 😎 #comedy
00:18
HaHaWhat
Рет қаралды 18 МЛН
DIESEL GENERATOR CYLINDER HEAD OVERHAUL| FULL PROCEDURE.#marine
16:37
Main Bearing & Thrust Metal Overhauling- Of Auxiliary engine (YANMAR SERIES)
10:23
Basic Marine Engineering Knowledge
Рет қаралды 30 М.
OIL MIST DETECTOR ROUTINE AND ALARM TESTING
9:31
Marine Info Tech
Рет қаралды 6 М.
21_Disassembly of MET18SRC YANMAR GENERATOR 6EY18L
11:15
Khan Jawaid
Рет қаралды 15 М.
Generator Reverse Power Protection Test | Pinoy ETO
7:36
Lecky Louie
Рет қаралды 9 М.
Спутниковый телефон #обзор #товары
0:35
Product show
Рет қаралды 2,2 МЛН
Первый обзор Galaxy Z Fold 6
12:23
Rozetked
Рет қаралды 383 М.