Please can someone add instructions for setting the timer for forced charging on the new app as the inverter has disappeared
@SolarKitEurope2 күн бұрын
Explore Tongwei Solar's role as a leading polysilicon supplier and their commitment to sustainable energy solutions. 🌞🌍
@SolarKitEurope3 күн бұрын
Thanks for watching! 👍 If you found this helpful, check out our channel for more inverter setup videos and visit our webshop at shop.solar-kit.eu for all your solar needs.
@SolarKitEurope3 күн бұрын
Interested in C&I PV solutions? Stay tuned for our upcoming Huawei C&I webinar! In the meantime, explore our solutions on the webshop: shop.solar-kit.eu
@SolarKitEurope16 күн бұрын
🌍Creating a sustainable future is our core mission at SolarKit.
@Chris-hw4mq20 күн бұрын
Why would I let you give me access to my equipment. I am the admin not you.
@SolarKitEurope28 күн бұрын
Test us for best prices! Register on our webshop: shop.solar-kit.eu/en/aboutus#registration-form
@cybostampile4308Ай бұрын
hello, I can't find the answer in the manual: for connecting a SM Eastron SDM230, which colors from rs485 / inverter go to A and B / 5 and 6 from SM? possibly the grounding... thank you very much!
@asadiqbalengineeringservic7680Ай бұрын
Great job sir ❤❤❤ I am Asad iqbal from Pakistan. I have+9 years experience solar installer in Pakistan 1kw to 800kw solar deferent solar projects. youtube.com/@asadiqbalengineeringservic7680?si=mdo9BUJF_KCDmJtT
@AftabAhmad-ei2skАй бұрын
Nicely explained
@SiBex_ovhАй бұрын
6:25 best way is say it's a order of 3 phase like proper L1+L2+L3 or L1+L3+L2 what have impact on rotate direction of electric 3phase motors and everyone say... ohh Now I see, nice to have that.
System work mode > zero-export power: 20. What is this actually? I'm a little bit confuse but from my understanding it will use the grid (build in CT) power to sense the voltage, current and frequency to match with generated AC power by the inverter. However, my meter still detect I'm using about 1.2 A from grid all the time. I've battery connected everything should run by the battery but not sure why. There's people also reported this on the forum. I've set this zero-export power to 0 but still my enerygy meter is showing I'm using about 1.x A all the time to power the inverter (mine is 8kw and grid is 240VAC) so means I'm using about 300w from grid all the time. All my house power connected to smart load. In deye app it showing 1A but on graph it showing I'm importing 0.
@SolarKitEurope4 ай бұрын
As load amount changes quickly when a device is shut down, the inverter cannot reduce the power at the same rate. So, to avoid injecting electricity back to the grid when it is not allowed, there is a given consumption that is always drawn from the grid first before the inverter starts up. Depending on the amount and type of electrical appliances, this number could differ. If the meter shows that the system is injecting back to the grid when it should not, then this number needs to be increased. We suggest starting with 20 W, as it is usually sufficient for many households and won't significantly affect performance. This adjustment serves regulatory purposes only.
@nt4hx4 ай бұрын
@SolarKitEurope Let me rephrase again - here is the scenario: during the day, My PV is generating enough power to charge my battery bank and to supply house consumption (connected to inverter smartload output). the rest of excess power generated by PV are being sell to the grid. This is good. When turns evening, night or PV not generating enough power to supply, battery will supply power to smart load. Grid should remains idle as there's are not enough power to sell, however grid consumption is at 1A I'm importing 1A all the - not sure why? The inverter should be powered by the battery as well. I've set this configuration. If it's using maybe 0.2 A i don't mind but, 1A is about 300W (depending on pf) for standby.. x24 hrs x30 days that's about 200kwh which is quite substantial.
@odoohub50102 ай бұрын
@@nt4hxyou can turn off grid charge, if that does not work, then do it manually by installing an isolator between your grid and inverter grid input, then switch the grid off.
@paweljandobruk17916 ай бұрын
Witam czy na pewno deye może pracować tylko na 100 % off grid . I mając aku 48 v . Ile z aku idzie a na kazda fazę . . Jak deye to dzieli Jak to praktycznie wygląda ?. Mając na przykład deye 12 kw 3 fazowy
@SolarKitEuropeАй бұрын
Dear Pawel! Are you sure that deye can work 100% off grid? Having 48v battery, how many from battery goes to each phase? How deye splits/divide it? How this looks in practice? Having as an example 3phase 12kw inverter
@SolarKitEurope7 ай бұрын
😱 We're at Construma with our wholesale! Solar panels, inverters, mounting gear… ☀ … and a user-friendly wholesale webshop! Check out our B2B page to offer top quality to your clients! ➡ shop.solar-kit.eu/en ⬅
@SolarKitEurope7 ай бұрын
👍 High-quality professional presentations from leaders at Huawei and SolarKit. ✅
@SolarKitEurope7 ай бұрын
Would you find a residential complex powered by renewable energy more appealing?
@SolarKitEurope7 ай бұрын
When work becomes a pleasure 🥳 because the view is breathtaking, the structure is professional, and the team is great. What do you think is the most crucial component of a solar panel system? For more references, check out our website: solar-kit.hu/
@SolarKitEurope7 ай бұрын
👋 Deye inverters and batteries are available through Solar Kit's official distribution. Future-proof off-grid systems, market-leading technological solutions. solar-kit.hu/deye-inverterek-es-akkumulatorok Read our entire article and feel free to reach out if you have any questions.