At 21:14 on Your presentation "NPSHr > NPSHa " . it is not correct for the NPSHr (Net Positive Suction Head required) to be greater than the NPSHa (Net Positive Suction Head available). In fact, for a pump to operate properly and avoid cavitation, the NPSHa must be greater than or at least equal to the NPSHr. This can be expressed as: NPSHa≥NPSHr If the NPSHa is less than the NPSHr, the pump will likely experience cavitation. Cavitation occurs when the pressure in the pump falls below the vapor pressure of the liquid, causing the liquid to vaporize and form bubbles. These bubbles can collapse violently when they move into higher pressure areas within the pump, potentially causing damage to the pump impeller and other components, reducing efficiency, and causing noise and vibration. To ensure safe and efficient pump operation: NPSHa: The actual pressure head available at the pump suction, considering atmospheric pressure, static head, velocity head, and subtracting vapor pressure and friction losses. NPSHr: The minimum pressure head required by the pump to avoid cavitation, specified by the pump manufacturer. Always make sure that: NPSHa≥NPSHr Anyway your presentation is excellent .... Thank you so much.
@elanchezhian.selanchezhian23748 күн бұрын
அருமை, நன்றி.
@freshpipes3817 күн бұрын
Great effort for animated presentation. For correction, rotation arrow is supposed to be counter flow or backward-inclined flow. As per Bernouli's principle when the velocity increases the pressure should decrease to balance the flow. And to avoid cavitation pump NPSH-R should be less than to what is available (NPSH-A)..Ergo NPSH-A > NPSH-R..Nicely presented just need some corrections.
@MechStudies15 күн бұрын
Thanks the error is at last few seconds and we have already acknowledged thanks
@mohamedouda2350Ай бұрын
Thanks for your remarkable efforts brother 💯
@MechStudies17 күн бұрын
Thank you
@KakaKaka-s6oАй бұрын
many thanks for This video and all information but i have a notice NPSHA always bigger than NPSHR
@MechStudiesАй бұрын
Correct, it’s a line at the last moment .. error.. we will make second part in details
@user-dh1tm6pl4iАй бұрын
ஆன்சர் 😊
@shafeeque556566Ай бұрын
Simplified presentation
@MechStudiesАй бұрын
Thank you
@shafeeque556566Ай бұрын
Well presented
@MechStudiesАй бұрын
Thanks a lot
@shafeeque556566Ай бұрын
Useful presentation
@MechStudiesАй бұрын
Thanks
@adisaseyi19452 ай бұрын
Best video I have watched on refrigeration cycle. Thank you
@MechStudies17 күн бұрын
Thank you
@sudhakarreddy45362 ай бұрын
❤❤
@MechStudies2 ай бұрын
Thanks a lot
@caiobraga34253 ай бұрын
Very good!
@MechStudies2 ай бұрын
Thanks a lot
@shortskills76123 ай бұрын
Great video 👍
@MechStudies2 ай бұрын
Thanks a lot
@anilpal59473 ай бұрын
Please upload more videos about mechanical seal, and glass lined reactor
@8016tm3 ай бұрын
Appreciation for this nice explanation
@MechStudies3 ай бұрын
Thank you so much for your words
@8016tm3 ай бұрын
Beautifully explained. Anyone can understand each basic concepts.
@MechStudies3 ай бұрын
Thanks a ton
@brokenarrow55904 ай бұрын
How come velocity and pressure can be increased at the same time 🤔
@MechStudies4 ай бұрын
😄
@freshpipes3817 күн бұрын
He is not following Bernouli's principle. He has his own principle..lol
@howardalexander67854 ай бұрын
Shouldnt be killing humans though
@MechStudies4 ай бұрын
🙃
@Nuttu8574 ай бұрын
Please tell me what is valve
@MechStudies4 ай бұрын
Thanks for visiting us, will make a video on valve too, thanks
@jamishrahman73554 ай бұрын
Very clear, thankyou ❤
@MechStudies4 ай бұрын
Thanks a lot, stay blessed
@aliabdulqader28815 ай бұрын
Suction pressure is P2 and not th total pressure ...the dynamic pressure V²/2g should be not added but subtract from Pa🙏
@MechStudies4 ай бұрын
Thanks for visiting us
@MechStudies5 ай бұрын
At time 21.14 : please read NPSHa>NPSHr: we will make a detail video on relationships
@EAR.Pakistan5 ай бұрын
In last, You said the NPSHR must greater than NPSHA. If available is less than required, how it works?
@MechStudies5 ай бұрын
This is a mistake … at the last second…🙏 will make second video for all these details
@gosula.amaralingeswararao86985 ай бұрын
Ur explanation is also sup
@MechStudies5 ай бұрын
Thanks a ton❤️❤️❤️❤️ for your nice feedback
@gosula.amaralingeswararao86985 ай бұрын
Good information ji sir tq so much for giving this information
@MechStudies5 ай бұрын
Stay blessed
@MohamedFathy-gr9cg5 ай бұрын
Great effort .. hanks for the information .. one point to be corrected if possible: NPSHa > NPSHr
@MechStudies5 ай бұрын
Rightly pointed out, it’s an error at the last minute, actually we have a plan to post second video where these details will be captured, thanks
@MohamedFathy-gr9cg5 ай бұрын
Good Luck and waiting for your new video :)
@fairuzsrozza58715 ай бұрын
Is it possible to obtain saturated air from unsaturated air without adding any moisture?
@MechStudies5 ай бұрын
Thank you for visiting us, yes surely you can do it. You can cool until the temperature equals to the dew point temperature.
@keirangrant16075 ай бұрын
Great video and information man. Really helps.
@MechStudies5 ай бұрын
Thank you soooo much🥰
@tilahunberihane16485 ай бұрын
Wow keep it up
@MechStudies5 ай бұрын
Thank you so much for visiting us❤️❤️❤️
@ayyubkhan71245 ай бұрын
I don’t find any use of background music..it’s annoying…edit that
@MechStudies5 ай бұрын
It’s our initial video, and later on we have changed the concept, thanks for your feedback
@mallikarjunan92076 ай бұрын
At last you told unsaturted air contain more water vapoure that may be wrong , unsaturted air contain less water vapoure
@MechStudies6 ай бұрын
Entire concept is less vapor or beyond the saturation for unsaturated vapor and that is concept, I am not able to remember if I said , but I hope you understand the whole concept
@mallikarjunan92076 ай бұрын
At video 5.31, while telling difference
@JohnLucas-se5wo6 ай бұрын
How many meters can absorb the water in down in pipe
@MechStudies6 ай бұрын
If you are somehow able to create a perfect vacuum, you can only lift a column of water 32.8 feet (9.997 meters) at sea level due to the atmospheric pressure that exists there. Not sure if you looking for the same, thanks a lot for visiting us
@abdulraheem.a97746 ай бұрын
Nice Explanation, Thank you
@MechStudies6 ай бұрын
Thank you so much
@royeaton31486 ай бұрын
Promo sm
@MechStudies6 ай бұрын
Thanks for visiting
@nusaibashakir90976 ай бұрын
Good explanation 👏
@MechStudies6 ай бұрын
Thank you so much , stay blessed
@antoniorivera9056 ай бұрын
Good explanation!
@MechStudies6 ай бұрын
Thank you so much🙏🙏
@etukudoodungide80687 ай бұрын
Very easy explanation
@MechStudies7 ай бұрын
Thank you so much
@vanhoangtran87837 ай бұрын
Thank you very much, the explication is very clear.
@MechStudies7 ай бұрын
Thank you so much for your feedback, stay blessed
@insani0w07 ай бұрын
good!
@MechStudies7 ай бұрын
Thanks for your feedback , stay blessed
@abdulwali99397 ай бұрын
NPSHa > NPSHr
@K_Jai208 ай бұрын
well explained, i was literally struggle for 2 days, but with your explanation was able to creat a hamburger model of the water pump in less than 15 mins, you really deserve a like and subscribtion
@MechStudies8 ай бұрын
Hi dear, thanks a ton for your valuable feedback, stay blessed😘
@anilpal59479 ай бұрын
I request to you please upload video on reactor mechanical seal configuration
@MechStudies9 ай бұрын
Thank you
@anilpal59479 ай бұрын
Excellent to understand very easy, thanks for this .
@MechStudies9 ай бұрын
Thank you so much,
@user-wu1hr1qm5h9 ай бұрын
Nice explanation.
@MechStudies9 ай бұрын
Thanks a lot
@anilpal59479 ай бұрын
Very very thanks for sharing valuable knowledge , I request to you please upload about mechanical seal configuration and plan
@MechStudies9 ай бұрын
Thanks a lot
@dr3ww._10 ай бұрын
Is that how dew and fog forms as well?
@MechStudies10 ай бұрын
Exactly 🙏 thank you for visiting us, stay blessed
@raziawi7710 ай бұрын
What animation u r using? Thanks
@MechStudies10 ай бұрын
It’s a combination of adobe after effects, photoshop, SOLIDWORKS (if 3D), premier PRO (for editing) thanks
@user-fb8ch4cy4x10 ай бұрын
Thanks so much my name is Med Signal i love the teachings about pumps centrifugal and positive displacement pumps I work in the mining section i work with this pumps pls friends I will follow-up with this teachings each and every time nice to meet.
@MechStudies10 ай бұрын
With a great pleasure… really feeling good that you liked it… appreciate, many more videos to come , stay tuned🥰🥰
@islamismayilov968810 ай бұрын
thanks for such a brilliant explanation and background music
@MechStudies10 ай бұрын
So nice of you, stay blessed...
@user-wu1hr1qm5h10 ай бұрын
Wow!very very nice video. Please make videos on interview questions. It will be very helpful for all the job seekers.
@MechStudies10 ай бұрын
Noted and thank you, we will keep it in our bucket list, thank you so much