@GuardianLords
@GuardianLords 4 күн бұрын
This is inspection and validation not calibration. Calibration is correcting and setting the range.
@ZakisHereNow
@ZakisHereNow 5 күн бұрын
You’re just trading the time of a CMM programmer/QE for the time of a designer/engineer. Thats why he says “oh there is some upstream work but we aren’t getting into that today”. 😂😂
@KamiCrit
@KamiCrit 10 күн бұрын
Denatured alcohol! Glad to know Mitutoyo uses something off the shelf.
@jobinbaby3558
@jobinbaby3558 11 күн бұрын
how you got that tolerance value? is it same for both digital and mechanical micrometer?
@jpf1950
@jpf1950 11 күн бұрын
Thank you Jim. That was so instructive.
@BurnedLeo
@BurnedLeo 13 күн бұрын
I never knew its so complicated
@sonikesarwani1770
@sonikesarwani1770 16 күн бұрын
I am interested in the specifications of the Mitutoyo surface roughness tester machine, particularly the range of Ra (Mean Roughness value) that it can measure?
@MitutoyoAmerica
@MitutoyoAmerica 15 күн бұрын
You can check out all of our current Surface Roughness products and their ranges by going here: www.mitutoyo.com/products/form-measurement-machine/surface-roughness/ If you do not find the information you are looking for there, for further assistance, please call us at 888-Mitutoyo (648-8869).
@KrazyGoodMods
@KrazyGoodMods 18 күн бұрын
Thank you! I just replaced the battery on my Mitutoyo caliper and it would not stay at zero after it was powered off. Holding the "init" button zeroed it out properly.
@gajanank3812
@gajanank3812 19 күн бұрын
Nice
@ramses512
@ramses512 21 күн бұрын
Where can i find replacement parts for mitutoyo blade micrometers?
@MitutoyoAmerica
@MitutoyoAmerica 15 күн бұрын
For replacement parts, you can use this link to find a local US distributor to you: my.mitutoyo.com/General/FindDistributor. If outside of the US you can find your nearest business: www.mitutoyo.com/about-us/worldwide-locations/ If you do not find the information you are looking for there, please call us at 888-Mitutoyo (648-8869).
@ramses512
@ramses512 15 күн бұрын
@@MitutoyoAmerica Thank you very much
@DarkGT
@DarkGT 22 күн бұрын
In other words learn how much force to use until you get a result you like, rather than the result that is in reality. It should be a blind test, use mechanical spring type of force to ensure equal force each time.
@MrWwiilliiaann
@MrWwiilliiaann 25 күн бұрын
Is there any update for Windows 11? when updating the computer the app stopped working, it must not be compatible
@miguelarturog.r.315
@miguelarturog.r.315 27 күн бұрын
Hi, which kind of cable did you use to data transmission? I know is a RS232 but what configuration.
@tomcox5063
@tomcox5063 27 күн бұрын
In my opinion and most others interapid is vastly superior.
@eccentricaste3232
@eccentricaste3232 29 күн бұрын
Pretty straight forward and easy. Thanks.
@FinnMcRiangabra
@FinnMcRiangabra Ай бұрын
Why standardize laziness? That is all it is to "short-cut" discussion of measurements. "One thou" means nothing. "One ten thousandths of an inch," actually means something and is not so hard that you need to be lazy about it. And why be lazy and say a "micron" instead of micrometer? It is not that hard to say micrometer. What is a "mil" is at millionth of something or a thousandth of something? Be specific and ignore this oaf. If you are specific and correct, misunderstanding is not your fault, but you may need to educate your listener so that they don't make a mistake. "unwritten" and "unofficial" slang has no place in any industry that relies on precision.
@FinnMcRiangabra
@FinnMcRiangabra Ай бұрын
One element of my job is scanning electron microscopic analysis. The scale of features is often in the range of 1 micrometer to 100 micrometers. I have never found it to be useful to be a lazy person and report measurements in "microns." Why be a lazy jerk and write "microns"? Look how easy it was for me to use actual units in the intro.
@darkmatter3538
@darkmatter3538 Ай бұрын
My old Job instead of using the word "Thou" for 1/1000 of an inch, they would use the word "mil" where "5 mils" would mean 5/1000 of an inch. and "mil" for 1/1000 of an inch is not to be confused with "mil" as in shortening the word "millimeter".
@luis_rico
@luis_rico Ай бұрын
Is it possible to add data automatically to an excel line by line after every end of program?
@strshooter7399
@strshooter7399 Ай бұрын
Gosh, I thought he was going to break the micrometer in half trying to open the plastic packaging! I figure these micrometers are well made and most likely pretty tough, but if I just plucked down $200.00+ > $300.00 bucks for a brand new digital micrometer, I'd be a bit more gentle with it just trying to get it out of the plastic! I like idea that it opens and closes faster, but for a backyard mech who needs a micrometer once in a blue moon, is it worth the extra money? Not for me, but if money were not a factor, I'd try a slice of that pie.
@D-FENS_
@D-FENS_ Ай бұрын
Gauge*
@markmoorhead1442
@markmoorhead1442 Ай бұрын
Is there a way to remove the 5th. decimal point? I have always used the old school style micrometers and tenths was always accurate enough. The company recently bought digital micrometers. I like them but the 50 millionths decimal place can throw me off.
@danielfelipeariasgomez6816
@danielfelipeariasgomez6816 Ай бұрын
Por
@michaelcheruiyot8855
@michaelcheruiyot8855 Ай бұрын
How you you get that 2 x 0.25...?😢
@abiramisub5935
@abiramisub5935 Ай бұрын
Please Do more QVPAK software tutorial. How to use measure tools one by one for the beginner.
@sushmautnoori5596
@sushmautnoori5596 2 ай бұрын
What is the applied pressure from the stylus?
@josephlecheminant2231
@josephlecheminant2231 2 ай бұрын
what are example applications of the .75mN detector vs the 4mN detector?
@josephlecheminant2231
@josephlecheminant2231 2 ай бұрын
would these units work well on non-machined surfaces? such as cast, or powder bed fusion 3D printing?
@mariocovarrubias9093
@mariocovarrubias9093 2 ай бұрын
And how to use them
@mariocovarrubias9093
@mariocovarrubias9093 2 ай бұрын
New tools
@alocin110
@alocin110 2 ай бұрын
He needs to calibrate his MOUTH. Advertiser like him are not appreciated. He should have titled this video "Take our Courses for Calibration", one simple dumb looking instrument he was showing, was not necessary. But there are con artist like him. I disliked your video and put your channel ID in my firewall to never to watch unproductive, meaningless, and garbage ever again.
@md.aa730
@md.aa730 2 ай бұрын
As you said about ASME b89.1.14, there is a table there containing the MPE values for checking and comparing our measurement errors like 'E'. So if E is less than the MPE value, but not zero, must we add the value of the measured E to the next measurements we take when measuring???
@freestyla101
@freestyla101 2 ай бұрын
So if I understood correctly, calibration is essentially an accuracy test? There is no other adjustment aside from zero.
@pirminkogleck4056
@pirminkogleck4056 2 ай бұрын
Dear Mitutoyo USA , i have a question regarding the Metrology handbook 2nd edition. i am based in Austria and i can not get this book in my Country, even thru official Mitutoyo Vendors its not accesible. is there a chance to somehow get this book ?
@bmwn5238
@bmwn5238 2 ай бұрын
is there a metric digital caliper with resolution 0,001? . for example to mesure 49.094 mm
@pirminkogleck4056
@pirminkogleck4056 2 ай бұрын
I wish I could work for such an amazing company! I love all my Mitutoyo products and treat them with respect. It just so happens that I ordered my first granite surface plate, and of course, it's a Mitutoyo. :)
@JGD444
@JGD444 2 ай бұрын
Me too! I love Mitutoyo.
@pirminkogleck4056
@pirminkogleck4056 2 ай бұрын
@@JGD444 The Best of the Best ! its everytime a Joy to use my Quantumike and the Calipers...it doesnt get old !
@EvelOttos
@EvelOttos 2 ай бұрын
Given your outside calibration data test points, what minimum measurement would you be comfortable declaring this caliper be used for and how would you back up that declaration? I will tell you from experience that when presented to modern medical device auditors, they will have issues with this caliper being used for measurements smaller than the lowest calibration point (1.0").
@hawks9142
@hawks9142 2 ай бұрын
You know you've made it when an international standard is set because it's convenient for you
@wemcal
@wemcal 2 ай бұрын
Great video and great information
@eprohoda
@eprohoda 2 ай бұрын
Mitutoyo. Super,very epic -have a nice day- 📢
@severedlightning
@severedlightning 2 ай бұрын
How do you get the 1 back on your 1-2?
@9twogaming
@9twogaming 2 ай бұрын
How can I download the software I uninstalled by mistakely
@MitutoyoAmerica
@MitutoyoAmerica 2 ай бұрын
To best assist you, please call us at 888-Mitutoyo (648-8869).
@stevencuriel2748
@stevencuriel2748 2 ай бұрын
❤ that’s a nice TI
@robbybakhtiar2433
@robbybakhtiar2433 3 ай бұрын
Hola.. I just changed the battery but it can't turn on. How to fix it?
@MitutoyoAmerica
@MitutoyoAmerica 2 ай бұрын
To best assist you, please call us at 888-Mitutoyo (648-8869).
@alberthendricks342
@alberthendricks342 3 ай бұрын
I think it is the van der waals force that holds the blocks together.
@FRJ1982
@FRJ1982 3 ай бұрын
So this may sound like a dumb question, but so if the calipers do not come within specification would they just be considered trash? Or is there a possible way to correct them
@KennedyNdumba-sb6tc
@KennedyNdumba-sb6tc 3 ай бұрын
THANKS FOR LETTING ME KNOW THIS 👏
@magnusklahr8190
@magnusklahr8190 3 ай бұрын
Exellent programs! Very informative and educationel. Greatings from a metric guy!😀
@albertluca7753
@albertluca7753 3 ай бұрын
your videos is more about outside micrometers, how about inside micrometer?, you didn't know how to calibrate it?
@albertluca7753
@albertluca7753 3 ай бұрын
inside micrometer calibration sir
@rjbrown1
@rjbrown1 3 ай бұрын
Very nice!