Biasi Combi boiler. No heating
2:40
New radiator install
15:59
3 ай бұрын
Ferroli Optimax 25C. Boiler repair
14:59
Toilet repair. DIY.
39:25
6 ай бұрын
Vaillant Ecotec Pro. F75 Fault
3:26
Пікірлер
@zenastronomy
@zenastronomy 16 сағат бұрын
my fan keeps turning on every 8min for 10sec for no reason, no taps turned on or anything. any ideas why?
@northwestgascertificates
@northwestgascertificates 13 сағат бұрын
Difficult to say without seeing the boiler. Maybe you have pre heat on which turns the boiler on every so often to heat a small store of hot water within the boiler...
@zenastronomy
@zenastronomy 8 сағат бұрын
@@northwestgascertificates I switched everything to off. the actual flame doesn't turn on. Just the fan or pump.
@northwestgascertificates
@northwestgascertificates 2 сағат бұрын
@@zenastronomy so difficult to say without being there. However if you phone the boiler's technical line, they will tell you if that is correct for that boiler. They will know for sure...👍
@northwestgascertificates
@northwestgascertificates 2 сағат бұрын
What brand of boiler is it??
@zenastronomy
@zenastronomy 16 сағат бұрын
why would a dead leg cause the fan to turn on in boiler?
@northwestgascertificates
@northwestgascertificates 13 сағат бұрын
Its possibly the air trapped there. You turn the cold tap off and you get some movement which tricks the flow sensor in thinking you ve put a hot tap on...
@Peejue
@Peejue 2 күн бұрын
Perfect, thank you
@stephenpollard6902
@stephenpollard6902 4 күн бұрын
Just wanted to say thank you
@northwestgascertificates
@northwestgascertificates 3 күн бұрын
👍
@jjohnson-stoker
@jjohnson-stoker 6 күн бұрын
Mine is 12 years old, always serviced it myself and it has just broken down for the first time with a gas valve failure. Cant really fault intergas boilers, they are well designed.
@justmemimi7338
@justmemimi7338 7 күн бұрын
This is very helpful, thank you. I suspect this is the issue affecting one of my gas jets. The woman offering a cup of tea is adorable. So British!
@daz3745
@daz3745 12 күн бұрын
Glad to see you're still using your old plastering skills. Skills pay the bills and it doesn't matter which ones you use.
@davidnjoroge5576
@davidnjoroge5576 13 күн бұрын
Does oil work
@northwestgascertificates
@northwestgascertificates 13 күн бұрын
I would always use specific gas cock grease. There are many available and not expensive
@Noname4now2025
@Noname4now2025 13 күн бұрын
If i press - and + together what s happend?
@northwestgascertificates
@northwestgascertificates 13 күн бұрын
It states it will go into chimney sweep mode. However in the manufactures instructions and whenever I've been with a Vaillant service engineer, they always use the P.01 test mode to put it into high service mode. Therefore i have always done that as well...
@Noname4now2025
@Noname4now2025 13 күн бұрын
@@northwestgascertificates the temperature raise instantly...IT îs problem?
@northwestgascertificates
@northwestgascertificates 13 күн бұрын
@@Noname4now2025 hello. Yes do not press these together. This is just for a gas engineer to do
@jessm9274
@jessm9274 15 күн бұрын
Were getting an E1 errors on this boiler. No drop in pressure though still at 2 bars? Generally if i reset the boiler it seems to start working, but then itll go again a day or so later
@northwestgascertificates
@northwestgascertificates 15 күн бұрын
Check the pressure guage needle isn't stuck on 2 bar. Does it go up when the heating is put on. The pressure sensor inside the boiler maybe at fault as it is this that will generate the E1 code if the pressure is to low not the actual dial on the front of the boiler...
@dr.sravanthysunder941
@dr.sravanthysunder941 17 күн бұрын
I sawbyour video and fixed fire alarm batteries.thanks a ton
@adreenryan2901
@adreenryan2901 18 күн бұрын
Would high pressure stop the boiler from running.
@northwestgascertificates
@northwestgascertificates 18 күн бұрын
If the pressure ever goes over 3 bar, the pressure relief valve opens up and then often needs replacing. You don't want that. If the pressure starts cold at 2 bar, when the radiators start to heat up, the water in them expands and the pressure will always go up and there is a chance it could reach 3 bar...
@chumber05
@chumber05 20 күн бұрын
Thank you for video
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos 21 күн бұрын
Nice one NWGC
@northwestgascertificates
@northwestgascertificates 21 күн бұрын
Cheers. You ve been busy lately with your videos 👍
@rashtheplumber
@rashtheplumber 21 күн бұрын
Is that an opening within 300mm of flue outlet?
@northwestgascertificates
@northwestgascertificates 20 күн бұрын
I think its just a mark on it. Ive re watched but can't really tell to be honest. I didn't notice it at the time...
@bikusmoto59
@bikusmoto59 25 күн бұрын
That's a deep bath trap. In what circumstances would a shallow bath trap be used?
@northwestgascertificates
@northwestgascertificates 24 күн бұрын
Only if a deep one was going to hit the floor below. Often there isn't a lot of room so a shallow one is needed 👍
@bikusmoto59
@bikusmoto59 25 күн бұрын
Can you use Plumber's Mate instead of ghastly smelly silicone?
@northwestgascertificates
@northwestgascertificates 24 күн бұрын
You possibly can but i never use plumber's mate for anything to be honest...
@bamaketsemochedisi6062
@bamaketsemochedisi6062 26 күн бұрын
🎉
@Arsenal-81
@Arsenal-81 26 күн бұрын
it works, thats the main thing 😂
@paulyoung6165
@paulyoung6165 29 күн бұрын
How do you change the boiler set up from Nat Gas to LNPG once the adaptor kit has been fitted and installation is completed. thanks
@northwestgascertificates
@northwestgascertificates 29 күн бұрын
I won't lie. Ive never done it plus ive not got my lpg. I would phone Ideal👍
@kirren7255
@kirren7255 Ай бұрын
Top tip 👍🏻
@madmaycon2531
@madmaycon2531 Ай бұрын
😮😮😮😮😮
@Primexelite8680
@Primexelite8680 Ай бұрын
I love viessmann.. rinnia = 20 torq screws for simple diagnostics + random chinese letters lol. Germany has been the innovativers of plumbing for a while.
@bobnoxious1983
@bobnoxious1983 Ай бұрын
Top man. Great explanation 👍
@STEVES7EVE
@STEVES7EVE Ай бұрын
When it's your first day on the job and you realise there's a tool for everything
@northwestgascertificates
@northwestgascertificates Ай бұрын
😄
@quratulainmalikquilling9864
@quratulainmalikquilling9864 Ай бұрын
Thankyou so much was cleaning with tooth pick gas was not coming through
@aliderisi8656
@aliderisi8656 Ай бұрын
You didnt say turn the radiator off
@goffyglos5675
@goffyglos5675 Ай бұрын
Try a grill..
@daz3745
@daz3745 Ай бұрын
😆
@jasonowen8000
@jasonowen8000 2 ай бұрын
Why take vessel out ? Just replace top, unscrew the top clean the body no need to take the whole brass part out 2min job
@madmaycon2531
@madmaycon2531 2 ай бұрын
😅😅😅Proper Job!!!😂😂😂😂
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
🤣🤣
@kennydaniels6285
@kennydaniels6285 2 ай бұрын
My bath is leaking and you have given me the confidence to tackle it in my own, brilliant video mate and well explained, thanks 👍👍
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
No worries. Glad it was a help to you 👍
@TheDickPuller
@TheDickPuller 2 ай бұрын
Using Coke or Irn Bru is great for cleaning the HX, but you do need to flush it with water after, a good flush!! The Vokera Easiheat is a great wee budget boiler👍👍👍 We look after about 150 here in the West of Scotland. They do need a ‘strip down’ service every couple of years. You also must clean the Condy Trap & Check the Co2, adjust as required. Wee Tip; When don’t your Hi & Lo tests on these. Run the HW & remove the Diverter Valve Actuator. The boiler will remain fired up even on the smallest systems.👍👍👍
@aivarasc7525
@aivarasc7525 2 ай бұрын
What there is no pipe like that or taps like that?
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
A lot of times the taps are under the boiler on the vokera. It will be 2 little taps
@mrt227zxr
@mrt227zxr 2 ай бұрын
Horrible boilers
@rjkelectrical6086
@rjkelectrical6086 2 ай бұрын
Could you not of wired a 3 core and earth, And wire Live supply of the boiler terminal to the live terminal of the receiver then linked L and 1 together in receiver Then from 3 of the receiver to the switch live return To boiler?
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
Im unsure. The other end of that 5 core literally joined the live, neutral and earth at the boiler supply. Then the normally open and common went where the link wire originally was in the boiler. Im not going to lie, i need more education when it comes to electrics...
@zaczac3024
@zaczac3024 2 ай бұрын
Built in thermistor in heat exchanger, cannot be replaced When this $5 part fails the boiler is scrap, guess how I know this 😂
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
I don't know but Alpha have the same problem. If the flue thermistor goes it is also a new main heat exchanger 🤦‍♂️
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos 2 ай бұрын
Bumped into one of these recently and was wondering about hi and lo. Nice one
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
Viessmann do make things complicated...
@rigel8755
@rigel8755 2 ай бұрын
Didn't need to go so hard on the soundtrack bro, DJ Shadow is just for special occasions :)
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
🤣🤣👍👍
@leonapater6071
@leonapater6071 2 ай бұрын
You helped me a lot
@victorvacari6884
@victorvacari6884 2 ай бұрын
Hi, I've got CFS message and beeping every 10 mins, i know its due for service, howevere can i meantime to get rid of this mesaage? Thanks.
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
Hi. I had the same and phoned Vokera. They talked me through removing this. It was pretty complicated and i wish i had captured it all on a video. You will have to phone them im afraid 👍
@zxcherry7356
@zxcherry7356 2 ай бұрын
How do u get it on low fire
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
Same as high fire but you turn either the water temperature control knob right down or the radiator temperature control knob right down 👍
@zxcherry7356
@zxcherry7356 2 ай бұрын
@@northwestgascertificates 👍👍
@user-hm9fg6jl8t
@user-hm9fg6jl8t 2 ай бұрын
Thanks for the video. I had the same one. No display fan running constantly. Called ideal they said PCB. But the customer wanted a new boiler instead as they have spent lots on it already.
@brahimaitoukharaz3039
@brahimaitoukharaz3039 3 ай бұрын
hello, I have a vaillant ecotec plus vcw 356 3-5 boiler that works with natural gas and I would like to run it with propane gas. Sincerely
@northwestgascertificates
@northwestgascertificates 3 ай бұрын
You will need to buy a conversion kit to change from natural gas to lpg. Propane i am not sure. I would ask Vaillant technical about that 👍
@ElectricRootz
@ElectricRootz 3 ай бұрын
Mine doesn't reset when I do this. It keeps going back to A01. There is a 💧 symbol with an x going through it. No flame either. It's doing my head in. I've had a couple of plumbers to check it out and none of them can seem to fix it.
@northwestgascertificates
@northwestgascertificates 3 ай бұрын
Sometimes it works out cheaper to just call out Vokera. They will do a one price fix all deal. Its guaranteed to be sorted...
@raj080288
@raj080288 3 ай бұрын
Hi, do we have to release any air that is left in the schrader valve before we replace it?
@northwestgascertificates
@northwestgascertificates 3 ай бұрын
No. As you start removing the Schrader valve any air will come out anyway..
@raj080288
@raj080288 3 ай бұрын
@@northwestgascertificates thanks mate
@perryplacey9318
@perryplacey9318 3 ай бұрын
Thanks always have to come back to this video 😅
@northwestgascertificates
@northwestgascertificates 3 ай бұрын
Glad it helps 👍
@raj080288
@raj080288 3 ай бұрын
Great video. What is that spray called you sprayed on the valve to check for leaks?
@northwestgascertificates
@northwestgascertificates 3 ай бұрын
It is rothenberger leak detection fluid. You can use a bit of fairy liquid though as well...
@raj080288
@raj080288 3 ай бұрын
Diluted fairy liquid or pure?
@northwestgascertificates
@northwestgascertificates 3 ай бұрын
Diluted. Just to make sure it is not letting any air out. It will bubble a bit if it is leaking..
@raj080288
@raj080288 3 ай бұрын
​@@northwestgascertificates thank you so much, appreciate the prompt response
@amansukoon
@amansukoon 3 ай бұрын
How can i put timings for heating to turn on on specific times?
@northwestgascertificates
@northwestgascertificates 3 ай бұрын
You need to wire in an external thermostat. I have done another video on that 👍
@userscott
@userscott 3 ай бұрын
Thank you. This was exactly what I needed - spent about an hour on it. 😂
@christophergould4013
@christophergould4013 3 ай бұрын
I found this very useful as I have just had a new boiler fitted with this very problem so will investigate thanks