Ceramill DRS Pre-op Workflow
6:00
Ceramill Software Manager
1:42
Ceramill Software Manager
1:42
Ceramill DRS Pre-op Workflow
6:00
Ceramill DRS Pre-op Workflow
6:00
Ceramill DRS Pre-op Workflow
5:59
Ceramill DRS Pre-op Workflow
6:00
Ceramill DRS Pre-op Workflow
6:00
Ceramill Software Manager
1:42
Ceramill Software Manager
1:46
Ceramill Software Manager
1:46
Ceramill Software Manager
1:46
Пікірлер
@Sophie-um4vz
@Sophie-um4vz 10 күн бұрын
Super! Vielen Dank!
@Zona-rr2zp
@Zona-rr2zp 12 күн бұрын
For connectors aint it way better to first separate crowns with a disc for example disc diameter of 0.6mm(if your smalest burr is 0.6) bcz if is like yours the cam software will block it(bcz 0.6 mm bur cant fit ) ..and if you dont do that correctly after that you gonna need to separate teeth in green state(white zirconia) Second i see you are using a trimmed model (demmo case) i dpnt trim models ..theres no point i will not create coppings manualy but by scanning them (second when you treem models you lose details and there will be always some inaccuricy..(plaster particle preventing the pin ho sit on his original space (even byn 1/20 of mm... Third: ..when we were working in analogue way we used either gold or silver spacers (gold is 0.1mmband silver 0.15mm ..golden one we used only when wanted a super tight fit with crowns made either from Gold or metal(eg flexible materials ) ..theres no reason to go below 0.1mm to 0.05 ..(those 0.05mm aditional gap for cemment wont affect transparency of crown) ... Forth what about Tangentional preparation of teeth ? Majority of doctors do work like that ..
@vernicebrown-griffin4443
@vernicebrown-griffin4443 16 күн бұрын
Thank you for this video. It is really informative.
@Queenssss87
@Queenssss87 25 күн бұрын
Thankyou
@Queenssss87
@Queenssss87 25 күн бұрын
Thankyou
@GgGg-ip9ps
@GgGg-ip9ps 3 ай бұрын
Sehr schön präsentiert!
@nattiorpaz6772
@nattiorpaz6772 3 ай бұрын
Consider choose Ceramill Gen x for my crowns / veneer restoration ❤
@jamshidkhan913
@jamshidkhan913 6 ай бұрын
Please upload vedio in English so that everyone can understand
@AmannGirrbachHQ
@AmannGirrbachHQ 6 ай бұрын
Hi! Thanks for your comment. This product is currently only available in Germany, Austria & Switzerland, therefore no English version exists.
@janderlacerda6933
@janderlacerda6933 6 ай бұрын
Estou precisando do software ceramil map
@AmannGirrbachHQ
@AmannGirrbachHQ 6 ай бұрын
Please turn to your Amann Girrbach distributor.
@Bor.der.Collie
@Bor.der.Collie 6 ай бұрын
War der weiße Schleifkörper ein Arkansasstein?
@AmannGirrbachHQ
@AmannGirrbachHQ 6 ай бұрын
Ja genau, es ist der Arkansasstein - Art. Nr. 875536
@Xydorf
@Xydorf 7 ай бұрын
The sintering oven can also glaze? Or do you need a separate oven for that?
@AmannGirrbachHQ
@AmannGirrbachHQ 7 ай бұрын
Hello! Thank you for your comment! Yes. The Ceramill Therm DRS can also glaze.
@amirmo6615
@amirmo6615 8 ай бұрын
Thanks very much for posting this. Cheers!
@AmannGirrbachHQ
@AmannGirrbachHQ 8 ай бұрын
glad you liked it 🙂
@lisu7110
@lisu7110 9 ай бұрын
perfekt
@elouistano4857
@elouistano4857 9 ай бұрын
Das System sieht sehr vielversprechend aus. Ich habe jedoch in keiner Broschüre gefunden, welche Auflösung der Intraoralscanner hat. Neben der Auflösung interessiert mich dann natürlich noch mit welchem Spektrum der Scanner arbeitet. In ein paar Videos sah das Licht am Intraoralscanner sehr blau aus, aber das kann ja täuschen. Ich hoffe ihr könnt mir bei meinen Fragen weiterhelfen. :)
@AmannGirrbachHQ
@AmannGirrbachHQ 8 ай бұрын
Hallo elouistano4857 entschuldige die späte Rückmeldung und vielen Dank für das Interesse an unserem Produkt :) Häufig werden die Auflösungen der Intraoralkameras nicht angegeben, weil 3D Daten durch eine Technologie errechnet werden und die Technologie entscheidet dann die Genauigkeit. Was wir aber als relevantes Feedback zu deiner Frage sagen können ist: Wir nehmen bis zu 60 3D FPS (Bilder pro Sekunde) auf und haben eine Genauigkeit mit dem Scanner von: - Einzelkrone: 10.0μm ± 0.84 - Quadrant: 17.8 μm ± 0.80 - Vollkiefer: 27.3 μm ± 6.28 Beim Spektrum arbeiten wir mit RGB Farben im Rahmen von 400 - 700 nm Wellenlänge und das blau liegt bei 450nm Hoffe wir konnten dir damit weiterhelfen :)
@UIWGHAGBVARLIG
@UIWGHAGBVARLIG 10 ай бұрын
Wie verhält es sich denn, wenn die äußeren Gehöreingänge asymmetrisch zueinander sind? Wie richte ich den Gesichtsbogen dann parallel zur Bipupillarlinie aus?
@AmannGirrbachHQ
@AmannGirrbachHQ 10 ай бұрын
Mit dem Anlegen des Gesichtsbogens wird die Lage des Oberkiefers in Relation zu den Kiefergelenken und der Schädelbasis ermittelt. Mit den ermittelten Werten kann das Oberkiefermodell Lagerichtig zu den Kondylen, in einen Artikulator eingesetzt werden. Dadurch minimieren wir Anpassungsprozesse der fertigen Arbeit im Patientenmund. Ansatzstellen des Gesichtsbogens sind die Gehöreingänge, die ein arbiträres Ausrichten des Gesichtsbogens zulassen. Dies ist auch möglich bei asymmetrisch angelegten Gehöreingängen (was fast immer der Fall ist). Im frontalen Bereich findet die Abstützung auf der Glabella statt unabhängig der Lage der Bipupillarlinie. Die sagittale Ausrichtung richtet sich je nach Methode an der Frankfurter Horizontalen, oder wie bei uns im Artex System , an der Patientenhorizontalen aus. Beim Anlegen des Gesichtsbogens spielt die Position der Bipupillarlinie keine Rolle. Diese wird erst später benötigt um den richtigen Verlauf , bzw. transversale Ausrichtung der Schneidekanten der Oberkieferfrontzähne aus ästhetischer Sicht festzulegen. Das ist bei uns auch möglich. In unserem Ceramill System benutzen wir hierfür Patientenbilder, die in die CAD Software integriert werden, oder den digitalen Gesichtsbogen Zebris.
@ripper_luchalibre
@ripper_luchalibre 10 ай бұрын
Mi dispositivo no dispensa el agua solo el yeso
@AmannGirrbachHQ
@AmannGirrbachHQ 10 ай бұрын
Hola, por favor póngase en contacto con su distribuidor Amann Girrbach si su unidad ya no dispensa agua.
@jeanpierrecazeaux239
@jeanpierrecazeaux239 Жыл бұрын
zirconia wet milling a complete non sens, especially with direct ultra speed sintering
@AmannGirrbachHQ
@AmannGirrbachHQ Жыл бұрын
Hi and thank you for your comment! Our Ceramill Therm DRS offers a super speed sintering including Auto-Dry of 25min for wet milled restorations.
@dorisbest7580
@dorisbest7580 Жыл бұрын
Why ta patent's jaw has been manipulated? Patients just do not move their jaws as has been manipulted,won't register natural patent's movements be beter than artificial robotic manipulation? What's th esense of such "registration"?
@AmannGirrbachHQ
@AmannGirrbachHQ Жыл бұрын
Dear doris best, thank you for your comment. The essence of the jaw movement registration is to register the natural movement of the jaw, so the needed dental prosthesis can be adjusted to the individual needs of the patient. It provides the dentist with an automated patient documentation and helps the dental technician to ensure the perfect fit of the restoration.
@dorisbest7580
@dorisbest7580 Жыл бұрын
@@AmannGirrbachHQ yes,that's waht I thought,but if you move patient's jaw in different directions iy is not as patient do it by himself,you manipulate patient's jaw,and this artificial move might not be the same when patient performs it his own way...that's weird you think that by moving patient's jaw with you hands you register patient's natural movements .
@AmannGirrbachHQ
@AmannGirrbachHQ Жыл бұрын
@@dorisbest7580 Yes you are right , the movements of the jaw should be the natural movements of the patient. Usually, the dentist practices the movements before the digital recording with the patient, to show how the movements should be performed. During the digital recordings itself the patient should move the jaw naturally. For the recording, the dentist supported the “patient” for demonstration purposes for the video.
@Retroguitarist
@Retroguitarist Жыл бұрын
Top, vielen Dank!
@foolishpanda8271
@foolishpanda8271 Жыл бұрын
The plate you have attacked to the Articulator, how would you remove it to readjust it?
@AmannGirrbachHQ
@AmannGirrbachHQ Жыл бұрын
Hi! We have a video, which shows the process: kzfaq.info/get/bejne/jJ6oq9yBzJrGfWQ.html Otherwise, here's a quick explanation: you need to remove the magnet at the bottom splitex plate with the magnetic lifter. Then the magnetic pot, in which the magnet was located, is turned out with the provided key. Then the now visible screw is loosened with the Allen key and the lower glued splitex plate with holder can be removed from the articulator. The splitex plate and the glued splitex plate holder are then placed in hot water for 10 minutes, which allows the two parts to be separated and then glued together again. The magnet and magnet lifter as well as the pot extractor are part of the splitex plate set.
@DentalProfile-uj3mx
@DentalProfile-uj3mx Жыл бұрын
can i ask what size was your softbox for the portrait shots at 26 mins?
@AmannGirrbachHQ
@AmannGirrbachHQ Жыл бұрын
Hi, the softbox is the Godox P120L (⌀ 120cm)
@DentalProfile-uj3mx
@DentalProfile-uj3mx Жыл бұрын
@@AmannGirrbachHQ Thanks for that info! Would you say the parabolic makes a significant difference compared to regular softbox? was looking at getting at godox SB-UBW 120 with a grid to help direct the light better
@x4ex
@x4ex Жыл бұрын
Is it applicable to other dentition defects like several teeth in a row, anterior bounded or posterior free-end defects?
@superdentist8662
@superdentist8662 Жыл бұрын
Just perfect
@mohamedalzoriqyy324
@mohamedalzoriqyy324 Жыл бұрын
Error while calbrate axis b.. Can you tell me why and fix it
@AmannGirrbachHQ
@AmannGirrbachHQ Жыл бұрын
Hi, Thank you for your message. For technical support please contact the Amann Girrbach partner you bought the machine from. Thank you!
@mohamedalzoriqyy324
@mohamedalzoriqyy324 Жыл бұрын
Please help.. How to fix error axis b
@AmannGirrbachHQ
@AmannGirrbachHQ Жыл бұрын
Hi! Please turn to your Amann Girrbach Reseller to fix the issue.
@arminsegovic9919
@arminsegovic9919 Жыл бұрын
Can you sterilize that plastic tray? If not, how do you clean it?
@AmannGirrbachHQ
@AmannGirrbachHQ Жыл бұрын
Hi! Thank you for your comment. The trays are only used once and will be disposed after one patient.
@mauritzhorn412
@mauritzhorn412 2 жыл бұрын
Sehr cooles und informatives Video
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Vielen Dank!
@andiavdiu3229
@andiavdiu3229 2 жыл бұрын
I can't believe it can be this good
@JMRAWS
@JMRAWS 2 жыл бұрын
Do you really mill Zirkon with water? 😅
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Hi! Thank you for your comment! Yes. The Ceramill Motion DRS is a wet mill only and the zirconia can also be milled like that.
@aminamri6614
@aminamri6614 2 жыл бұрын
hi, why the condylar inclinations in the first results ( 1:46 ) were 57° right and 51° left then in the report ( 2:03 ) it became 38.2 left and 45.1 right ?
@amauriguerrodutra3919
@amauriguerrodutra3919 2 жыл бұрын
Hj mandei mensagem muito bem
@katjaschwegler7157
@katjaschwegler7157 2 жыл бұрын
geniales Logo
@sinistar7778
@sinistar7778 2 жыл бұрын
lux
@hananfaour7144
@hananfaour7144 2 жыл бұрын
sehr hilfreich😊
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Danke, das freut uns! :)
@eprohoda
@eprohoda 2 жыл бұрын
Amann~ very incredible recodring! 🤞
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Thank you!
@mohamedelgon204
@mohamedelgon204 2 жыл бұрын
what the shrinkage factore of this matrial
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Hi! Thank you for your question! The shrinkage factore is different for each blank. It is shown on the packaging of each blank.
@cirkinkral2905
@cirkinkral2905 2 жыл бұрын
anlatım için saolasın kral
@olafkutschmann4589
@olafkutschmann4589 2 жыл бұрын
Es kommt häufiger vor, dass sich das KBS-Oberteil nicht mehr vollständig absenken lässt, weil das Modell auf dem Übertragungstand so hoch sitzt. Viele Kolleg:Innen senken dann den Tisch einfach ab. Führt das nicht zu Ungenauigkeiten? Gibt es eine andere Lösung für das Problem?
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Hallo Herr Kutschmann, vielen Dank für Ihre Anfrage. Wir werden sie intern an unseren Produktspezialisten weiterleiten und uns wieder bei Ihnen melden.
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Hallo nochmal Herr Kutschmann, hier die Antwort und der Tipp unseres Produktspezialisten: "Ja, das würde zu Ungenauigkeiten führen. Am Übertragungsstand darf man nichts verändern. Wenn man das Modell nicht in den Artikulator bekommt, sperrt man den Stützstift um 10 mm und artikuliert dann den Oberkiefer ein. Danach senkt man den Stützstift wieder um 10 mm und artikuliert den Unterkiefer ein. Dann stellt man die mittelwertige Kondylenbahnneigung von 35 Grad auf 45 Grad."
@olafkutschmann4589
@olafkutschmann4589 Жыл бұрын
@@AmannGirrbachHQWenn auch etwas spät: Vielen Dank für die Antwort, auch im Namen meiner Schüler*innen.
@obusventer4798
@obusventer4798 2 жыл бұрын
Love the SA Springbok rugby shirt at 24:39!!!
@cindyw.8877
@cindyw.8877 2 жыл бұрын
Habt ihr das auch auf Deutsch? Untertitel?
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Hallo! Leider nein - aber in unserer Academy haben wir einige Vorträge zu Zirkonoxid, die auch spannend für Sie sein könnten. Einfach registrieren und on demand schauen: academy.amanngirrbach.com/de/webinar/
@majdielmhdwi5472
@majdielmhdwi5472 2 жыл бұрын
Is the sintron needs oxidation and sandblasting after sintering and before wash application ? Thanks for the video
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Hi! Thank you for your request! Please check the instruction manual for Ceramill Sintron for further details on the processing: www.amanngirrbach.com/fileadmin/_agweb_2013/media/mediathek/Print/Instructions/Material/CAD_CAM/Ceramill_Sintron_INT.pdf
@doctoredable
@doctoredable 2 жыл бұрын
Very elegant and detailed lab work! I wanted to point out that even with the most accurate fitting restoration the restoration will fail because of contamination during the cementation procedure. Blood and or saliva will easily contaminate the surface of the tooth when cementation procedures are not done with respect for this very critical step in the restorative process. I always use retraction cords when cementing crowns that have margins that are equi or sub gingival. Total isolation is essential to long term success. Most failures of crowns are the result of contamination with blood or saliva during the insertion appointment. Proper cementation of a crown is often more difficult to achieve than the preparation and impression phase of the process.
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Thank you for sharing your experience and know-how with us and the rest!
@rodrigolucena7601
@rodrigolucena7601 2 жыл бұрын
How long does the collet usually last? Approximately
@pickosify
@pickosify 2 жыл бұрын
English subtitles will be much appreciated!
@joebeier5470
@joebeier5470 2 жыл бұрын
Unsere Geräte sind unerträglich laut, woran kann das liegen ?
@AmannGirrbachHQ
@AmannGirrbachHQ 2 жыл бұрын
Hallo Joe Beier, Das ist schwierig von hier aus zu beurteilen. Bitte wenden Sie sich an Ihren Amann Girrbach Reseller.
@ripper_luchalibre
@ripper_luchalibre 10 ай бұрын
Mi dispositivo no dispensa el agua , solo el yeso , a que se debe
@shighafmohammed4544
@shighafmohammed4544 2 жыл бұрын
Sehr schön präsentiert!