Пікірлер
@sallen900
@sallen900 13 сағат бұрын
Is the problem with the furnace that you are trying to pump from 500kPa into a pipe that is 8MPa? My guess is that you needed to pump in more fuel before igniting the furnace. I typically add the ices directly. with the furnace sideways and something in both hands and standing right up at the furnace input door, splitting from the mining bag drops the ice directly into the furnace even when the sun is out or in a warm atmo.
@sallen900
@sallen900 15 сағат бұрын
The heat was from welding the door, right? Almost no pressure, so adding any temperate gas would quickly drop that temperature I think.
@charlesheath7571
@charlesheath7571 21 сағат бұрын
For the filtration yea you can it’s slot index slot 0 is right filter slot 1 left. If you wana check for filter druribitly that is Quantity and the other viarable should be Occupied Ie: Ls r0 db 0 Qunatiry Div r0 r0 100 S diodeslide Setting r0 This will send a viaual red/green bar to a diode slide that you can set to one of the pins on the filter. Then slap the chip in it. You can also have the filter go from active to stand by via Mode 0 inactive 1 active with InputPressure or RatioInput(gas) commands you can automate it to go in and out of standby mode, standby uses 10W More options: Lbs r0 db Quantity Average Sub r0 r0 33 (this chip slot is a slot) Sgt r0 r0 5 S db Mode r0 Ls r0 db 0 Quantity Ls r1 db 1 Quantity Add r0 r0 r1 Div r0 r0 2 Sgt r0 r0 5 S db Mode r0
@charlesheath7571
@charlesheath7571 22 сағат бұрын
This might be a beta thing, but I can access the staionpedia (F1) .while in a code if screen . And yes it’s so NICE!
@sallen900
@sallen900 Күн бұрын
Looking forward to seeing him learn about the Sensor Lenses for finding ores/ices.
@mostrealtutu
@mostrealtutu Күн бұрын
holy shit, we got lights :)
@dwsage_
@dwsage_ 2 күн бұрын
There maybe some pipes ain’t connected in the basement ceiling?
@MultiGhostslayer
@MultiGhostslayer 5 күн бұрын
Sorry told you wrong. Pressure regulator on out put on stirling is for cooling off gas for eks water making. If you put regulator on the in port then you can save gasses and get most out of it and out put to free tru Cowell or passive vent . 1,5mp generate on 1500 degrees around 4 to 6 kwt whit lovely power.
@charlesheath7571
@charlesheath7571 6 күн бұрын
For the gas mixer u installed I have it auto adjust via a analyzer on the output pipe set to read ratio oxygen. It auto adjusts the setting by adding or sub depending on the ratio above or below the range I set. It keeps changing untill it’s the right ratio and adjusts if it starts to go the other way. As well ut turns it on/off if the fuel line drops below 20MPa The suit rack also fills ur jet pack 2 it’s the bottom in pipe on the back
@sallen900
@sallen900 7 күн бұрын
I about fell out of my chair when I saw you add the second can to the packaging machine since that is not a store for cans. Clearing them saved you since you would have added 5 tomatoes and lost them since 2 cans is not the recipe, right? But then you tried microwaving all 5 at the same time!!! Oh man! Loving this pain you cause for yourself. It couldn't have been better even if it was planned for entertainment.
@sallen900
@sallen900 7 күн бұрын
Anyone else wondering how much fuel is left in the welder? 35 days so far. Guess I'll have to keep watching to find out! Loving this play through Xero!
@peterward2875
@peterward2875 7 күн бұрын
The intentional move of suit items to the rack may be a failsafe. Say you're building out a room, and it's not liveable yet; or there's been an accident and it vented... Clicking on that giant hitbox for the helmet or suit on the rack by accident would be a disaster.
@sallen900
@sallen900 8 күн бұрын
He is a pro by now, but for us new and watching, he has N2 in the white O2 canister and needs to add a Nitrogen filter to prevent the alarm. Also, the furnace didn't warm due to him putting in water ice at 47:44 rather than oxite. He knew what is the right one but just grabbed the wrong one.
@peterward2875
@peterward2875 8 күн бұрын
Always print more cable if you have the copper and gold...
@sallen900
@sallen900 9 күн бұрын
For anyone new to stationeers, he needed to put liquid pipes for the liquids. He used gas pipes for both the gas output and liquid output. The bottle filler has a switch as well that he hasn't noticed yet.
@sallen900
@sallen900 9 күн бұрын
I just came to watch your first in the series after watching a recent one on H2 Combustion and Evaporator on Vulcan. You've come a LONG way, sir!!!!
@Xero1of1
@Xero1of1 9 күн бұрын
Thank you! I appreciate that!
@ToxiN0011
@ToxiN0011 12 күн бұрын
and simple Active vent on the filtration input would be much faster and better :P
@drakenarvaiz5444
@drakenarvaiz5444 13 күн бұрын
Hey bro if u ever wanna do a co op mars play thru season 5 id be down
@MultiGhostslayer
@MultiGhostslayer 15 күн бұрын
In start at the clip condensation in the pipe increase volume. You have hi pressure so pollution condes on 5meg at that temperature so if you increases volume whit utility inline tanks then you don't have that problem.
@ToxiN0011
@ToxiN0011 15 күн бұрын
i dont know if you found out already with that phase change thing, but you need to look at Latent not Convected, -12kJ is great, the only problem you have with this setup, its a bit to small for that room size. That code is also wrong if you didnt fixed that already,you might want to thing again about that "and Onoff1 Onoff 1 SuperLowCharge" you never check if the Generator is running, it will turn on at 25 and will turn off at 26, SuperLowCharge is pointless right now
@drcloseenough
@drcloseenough 17 күн бұрын
08:50 and watching that reagent mix just slowly roll into view, like a tumbleweed, while Xero was in mid thought just had me laughing so hard! No idea why but just gold.
@peterward2875
@peterward2875 17 күн бұрын
You can ask for "how many batteries" by getting the sum of one of the boolean values like "on" from the batch read command; or a second batch reader for the other bus. There's also the percentage charge in some other attribute, I think it's ratio? Finally there is a display mode for the LED's to whow kw/mw "power" (or percentage if you go with the calculations.)
@drcloseenough
@drcloseenough 18 күн бұрын
I'm at 34:30, so might already be addressed, but I was wondering when you'd check on your plants. Last several vids has the Harvey's showing the plants are unhappy, which is why they die. I'm guessing that the sunlight amount needs to be adjusted again, since you adjusted back when Vulcan was experiencing "winter." I wonder if you'll need a time indicator, to determine the current season, then set the light timer? Edit: Finished the video and awesome, you found the issue! Glad that you were able to catch it.
@DeltaV3328
@DeltaV3328 18 күн бұрын
The Condensation chamber and the condensation valve perform a similar function, and the evaporation chamber /purge valve perform a similar function. 1) you need to remove the condensation valve near your evaporator and place the purge valve in its place. For simplicity, The evap chamber and purge valve should be set to the same pressure. On the gas return pipe from the evap place a volume pump in the direction to the condensation chamber. This keeps the pressure low and stops condensation in the gas return pipe, and keeps the pressure high near the cond chamber. This promotes more condensation. I hope this helps
@Dropbaud
@Dropbaud 18 күн бұрын
Yes, let more gas out, make the pressure have a lower value for the purge valve, yes, you'll go through your liquid quicker, but that's why you condense more at night / Put the purged gas through a Radiatior at night to lower it's tempeture and recompress it to a liquid. Purge the water out with a filter
@makesamich1884
@makesamich1884 20 күн бұрын
Looking for the tablet while it was in your other hand was great, cant count how many times I've done that.
@drcloseenough
@drcloseenough 21 күн бұрын
Not sure if it was discussed (work lurking while I watch) or if you have already done it, but what about encapsulating the initial water system and including a powered vent and drain? If you over pressurize again, it can be captured in a smaller area that's isolated, with the ability to pump out the vapor and if it condenses for some reason, you have the drain there to capture any liquid water.
@Xero1of1
@Xero1of1 21 күн бұрын
The issue there is I'd need to encapsulate the enclosure with frames... otherwise the pressure released would destroy the walls.
@drcloseenough
@drcloseenough 20 күн бұрын
@@Xero1of1 good point! Maybe the boom room windows instead? Possibly adding a gas sensor with turbo pumps, to evacuate it all into a storage tank? A lot of work but given the environment, it might come in handy? Then again, my knowledge on Stationeers is very limited, so my suggestions might not be realistic.
@Dropbaud
@Dropbaud 21 күн бұрын
Hey, did you see the new start stuff. Not sure if it's Beta Branch or what. But 2 landers, Airlock kit, pnumatic miner among other things changed up for starting landers. Also the new Coco and Sugar update, setable printer stacks.. Man, I almost want a Numberpad Logic to set # amount to print.
@Xero1of1
@Xero1of1 21 күн бұрын
Yeah, Charles was talking about it during the livestream yesterday.
@charlesheath7571
@charlesheath7571 21 күн бұрын
Just place a passive vent on the cryo tube, it works and simple
@ratchet1freak
@ratchet1freak 22 күн бұрын
if you want to cool something down to 25°C you want to set the pressure to be a touch colder, otherwise it will never reach it.
@charlesheath7571
@charlesheath7571 22 күн бұрын
If ya want to see something…crazy, check out the starting loadout on Vulcan on the beta branch.
@DeltaV3328
@DeltaV3328 22 күн бұрын
I tried this but I didn't see anything different from normal branch
@charlesheath7571
@charlesheath7571 22 күн бұрын
@@DeltaV3328 unless it’s changed on the past few hrs(or a game mode) but for me was 2 O2 tanks 1 ea water, and liq N2 with 10 other crate! I was checking it out on a creative world, that might be the issue
@charlesheath7571
@charlesheath7571 22 күн бұрын
@@DeltaV3328 I just double checked, started a new game with all 4 game modes creative to stanioneer and all 4 had the same “new” load outs with 2 landers- 4 tanks 10 crates. On steam does it say Stanioneers[beta]? If that’s not it idk.
@charlesheath7571
@charlesheath7571 22 күн бұрын
@@DeltaV3328 another option kzfaq.info/get/bejne/lbCnaMudy92RaWQ.htmlsi=iXIeeL0_gSbydEu3, this KZfaqr will showcase it
@Coco6407
@Coco6407 24 күн бұрын
58:11 did you have an output set up for the biomass capsule? I think that is why it wasn’t working
@IBeHoppin
@IBeHoppin 25 күн бұрын
Great work
@ShaneCourtrille
@ShaneCourtrille 26 күн бұрын
This is why sane people start by drilling into a mountain and just building an exit.
@Xero1of1
@Xero1of1 26 күн бұрын
Whoever said I was sane? lolol XD
@ShaneCourtrille
@ShaneCourtrille 25 күн бұрын
@@Xero1of1 Learning a lot in the comments thanks to the little mistakes so thanks for that :D
@Xero1of1
@Xero1of1 25 күн бұрын
@@ShaneCourtrille we aim to please here. Lol 🤣
@cdm96247
@cdm96247 26 күн бұрын
Surprised no one mentioned to go to the other window to turn on the vent around 4:29 also the labeler can be made in the electronics printer.
@drcloseenough
@drcloseenough 28 күн бұрын
I love that this furnace is a thing. Making the furnace literally catch every time it passes through, though? *chefs kiss*
@al6452
@al6452 29 күн бұрын
Will you offer that machine to the workshop?
@Xero1of1
@Xero1of1 29 күн бұрын
Unfortunately, that machine and save no longer exist.
@charlesheath7571
@charlesheath7571 Ай бұрын
I’d double check that fuse…I think you have it set to 1k
@JoshuaMParker
@JoshuaMParker Ай бұрын
you could have also put the steam through a turbine
@charlesheath7571
@charlesheath7571 Ай бұрын
Does that cool the temp too?
@scul00
@scul00 Ай бұрын
56:49 - the whole system (pipe + canister) is being filled to 75%. The pipe section is 20L vs the canister of 18L, and since there is a higher volume in the pipe, you'll see more in the pipe. Also, gravity has no effect at the moment on liquid pipes.
@peterward2875
@peterward2875 Ай бұрын
The wall hit-box gets in the way, and since it doesn't interact with the wire cutters... there's no highlight that it's taking priority. Looks pretty, but gets in the way sometimes. You've got the work around of adding a protruding bit then cutting all of it out. PITA, but works.
@peterward2875
@peterward2875 Ай бұрын
Can you afford to make the X-ray specs (or whatever they are called)? Might have helped diagnose whatever this problem turns out to be getting power over the bridge. (Asking very early in the video.)
@Xero1of1
@Xero1of1 Ай бұрын
I can make them, yes, but I was able to figure out the problem without them. Cheers!
@eddiecrews
@eddiecrews Ай бұрын
Just found your channel and have been enjoying this play list. However... It hurt my soul and OCD watching these last few episodes when all of your frustrating troubles would have been resolved if you had built this setup in the big room with the heat exchanger... You already had most of the setup already waiting for you in there with the pumping system for the pollutant. All you needed was to tie that system in with the heat exchanger and a filtration system and you would have had water 4 episodes back. I felt your frustration so bad I had to go play that issue out in my own game just soothe my soul. Keep up the good work.
@charlesheath7571
@charlesheath7571 Ай бұрын
For the cooling system I was chatting about, first set up a liq Pol collection system with a tank for storage I used lg powered vents and 50 condensing valves (it was over kill!). Set it to start at 130 Vulcan air temp as well set to blow off at about 45MPa or lower. For the cooling I made 1x1x1 chambers with steel frames. the pipes going into chamber 1 are liq reg set to 1% (ic controlled to turn on when my CO2 tank was above 20C). Liq pipe>expansion valve >passive vent in the chamber. In the chamber there also a active vent ic control to 600 KPa and a passive liq Inlet. To connect chamber 1 to chamber 2 liq inlet pipe one way valve pipe expansion valve passive vent. Active vent in the chamber ic set to 800kPa chamber 3 is same as 2 except off the expansion valve I use this cold gas for cooling. For the active vents in the chambers I pull this gas and recycle it back to the liq Pol storage and use it via heat exchangers. Atm I started with 127C liq Pol over 5kL after running the system my CO2 collection is at 2.2 MPa 19.9 deg(its collection sys is auto as well) now my and my cooling stats are 111deg 5243L of liq Pol chamber 1 71.2, 2 23.3 3 -17.5. Power cost, mine is 550W idle 800 active, note I have 3 consoles per chamber that’s 50W ea and liq Pol Sys only kicks on when below 5kL and temp less than 130 I’m working on another collection sys that’s more fees-able on power cost Edit also ea chamber has a gas senor ofc
@DeltaV3328
@DeltaV3328 Ай бұрын
I'm sure you've already resolved these issues. 1) On the electrical brownout issue the Network board for the tablet and the new meso chip for the sensor lens are both useful troubleshooting tools. 2) The room pressure in your stirling room is too damn high. I think 100 kpa is the sweet spot.
@josem.ramalho2960
@josem.ramalho2960 Ай бұрын
😁Just missed the stream, hoping to catch the next one live !!
@ToxiN0011
@ToxiN0011 Ай бұрын
Change the stack size for the solder to let it cycle faster like 2-3 stacks
@DeltaV3328
@DeltaV3328 Ай бұрын
If you put a purge valve on the inline tank side water pipe set to like 12kpa and put the gas back in the furnace it should help cool that h20 down to a safe level.
@senseifreak5126
@senseifreak5126 Ай бұрын
Would like to cool Nitrogen to -183C then to condense it to liquied nitrogen to use it for evaporation cooling