Is this a 9 volt battery? Are you serious? Well, it's definitely fake. At least for the sake of decency, connect this to a laptop battery.
@mmmnnn54935 күн бұрын
KZfaq is only suitable for stupid and ignorant people here
@johnp13665 күн бұрын
The viability of this contraption not withstanding, one bad thing about it is that the perishable power supply is glued down
@user-lu7hl8tr2i7 күн бұрын
Ебать... Ты конь огонь!...
@HarmonRAB-hp4nk7 күн бұрын
co2 works fine :-)
@monikarrda7 күн бұрын
This is fake, Without compressor not work with, 12 volt pump for copper pipe.
@neilgelinas99269 күн бұрын
Bs fake.
@miscellaneousmarauders555210 күн бұрын
HIS COVER PHOTO IS BULLSHIT! HE CLAIMS THAT HE'S NOT USING REFRIGERANT BUT, LOL HE IS INDEED USING R600A. WHICH IS A VERY COMMON THING THESE DAYS, AS IT'S REQUIRED BY THE EPA! .....HOWEVER UNFORTUNATE THAT LITTLE FACT REALLY IS! IT IS INDEED TRUE AND MORE DANGEROUS THAN FOLKS EVEN REALIZE! LIKE, IF YOU GUYS KNEW JUST HOW MANY NEW COOLERS THAT I'VE CONVERTED AWAY FROM R290 AND R600A... AFTER THEY EXPLODED, YOU'D FREAK! THEY SUPERCEDED R12 AND R22, WHICH IS WHAT IS TRULY FREON.... A VERY LONG TIME AGO... WITH R134A AND R404A - OF COURSE THERE ARE A PLETHORA OF AZEOTROPIC AND ZEOTROPIC VARIATIONS THAT I DIDN'T LIST BUT, THAT'S BECAUSE THESE ARE THE MAIN PLAYERS... AND THEY TOO WERE SUPERCEDED BY R290 AND R600A... SO BASICALLY, THIS GUY JUST ASSEMBLED A SMALL FRIDGE SYSTEM.... LOL.. PROBABLY FIGURING OUT THAT ONE PUMP WASN'T ENOUGH BECAUSE HE DIDN'T BOTHER DOING THE MATH... I MEAN... HAHHAHA, HE CALLED THE CAPILARY TUBE METERING DEVICE AN "EXPANSION VALVE" !! EXPANSION VALES ARE ANOTHER FORM OF METERING DEVICE BUT, JUST NOT THE ONE HE USED TO BUILD THIS SYSTEM... WORKS ON A COMPLETELY DIFFERENT DESIGN CONCEPT AND ALL THAT FLIM FLAM JIM BEAM DAMN DETAILS NO ONE CARES MUCH FOR THESE DAYS... LMAO - SO, IM PRETTY SURE HE DIDN'T DO THE MATH HINCE; THE TWO PUMPS, NO SERVICE VALVE, HE JUST USED A SYRINGE, LOL... THE BRAKE LINE TYPE BUTT JOINTS ON HIS COPPER WORK... SMDH.. I'M JUST GONNA STOP... I COULD PICK THIS APART FOR 2500 WORDS EASY! \ JUST A HEADS UP... WHAT HE BUILT IS EXTREMELY FLAMABLE, I WOULD NOT RECCOMMEND BHUILDING THIS TO MY ENEMY, LET ALONE, YOU GOOD PEOPLE! CHILLING DOWN A HANDLE OF UR FAVORITE WHISKY WITH THIS DEVICE "AS SHOWN" AND THEN CONSUMING SAID HANDLE... NOPE... THATS -A- NOT A GOOD IDEA... IF YOU MUST BUILD THIS, GET A FEW CO2 POWERLETS AND INJECT THEIR CONTENTS INTO THE SYSTEM... GET RID OF THE FIRE HAZARD! GOD BLESS
@sarai305511 күн бұрын
Sorry thanks for wasting my time I realized as soon as he no compressio even though the gas would have worked except for injecting it. Liked the music.
@clownbooface262411 күн бұрын
Aaahh, more pajeet refreegereetors... LOL, scams
@Friedbrain1112 күн бұрын
Nothing like forcing a flammable and potentially explosive gas in liquid form into an oxygen atmosphere and then compressing it. Idiots unite! We want to prove we are stupid!!!
@glasslinger13 күн бұрын
Complete fake BS. I'm surprised that people in the comments professing to be engineers do not call this out!
@rottweiler953513 күн бұрын
THIS VIDEO IS FULL OF SHIT
@mohsenaghdam313614 күн бұрын
The problem is your PUMP this pumps has diaphragm system it’s just can be used for liquids,if a gas or air bubble stuck in diaphragm the pump no more push’s the liquid ,you hear the sound of pump working but it’s not working actually ,the best pump can be works in this system is piston vacuum pumps
@abbasbvohra14 күн бұрын
Stupid Project
@abbasbvohra14 күн бұрын
Stupid Project
@ra66ju9915 күн бұрын
Even this is fake.
@theuntouchables62147 күн бұрын
You are 1st grade fail student
@denisedsouza571116 күн бұрын
How did you seal the injection point ??
@deucedeuce15726 күн бұрын
He don't, because it's fake.
@denisedsouza571116 күн бұрын
Capillary / metering device installed at the discharge port 🤣🤣🤣
@lostvisitor17 күн бұрын
waisted my time I will block you now.
@DrHarryT18 күн бұрын
The principal is correct although a second pump between the expansion valve and the evaporator is abnormal, a pump there would be still pumping liquid coming out of the condenser. The faults are the pump not being able to generate enough pressure, the hoses not being able to take the pressure and not evacuating the air/moisture out first along with proper sealing ports for evacuation and charging refrigerant. Then there is the proper capillary expansion valve sizing and getting the quantity of refrigerant right. ~40L/175H PSI ??? [Obviously the pump would have to be able to pump up to 300PSI with sufficient volume.] Yes condensable flammable gas can be used as a refrigerant and propane has been used as a substitute for R-12. [Mexico that I know of]
@turb0t19 күн бұрын
i like the way that water droplets form on the copper pipes and then turn to frost. And also how the frost is only forming on the pipes at the front of the bottle, but not all the way around. Its like a regular can of compressed gasses was sprayed only on the front part to form frost and then thawed, and then the video was played in reverse
@glasslinger13 күн бұрын
You got it!
@dubaibrandbuilders19 күн бұрын
Which gas you added?
@user-pw8qj2gt1p16 күн бұрын
It's usually butane in these videos, but this doesn't work. It is fake.
@emiliomunoz145520 күн бұрын
Fake. El Isobutano es un gas refrigerante conocido como R600 o F600 para los franceses que lo llaman Freon.
@renelaplanche720122 күн бұрын
Effet Peltier
@johnsond419722 күн бұрын
what type of pump are you using . is it a mini compressor or a water pump? Can i 3d print one and use a motor?
@conchita28922 күн бұрын
No funciona eso
@ulicessiqueiros707323 күн бұрын
Lo único bueno de este video es el doblador de tubos😂😂😂😂
@franciscolopez-pm1ve24 күн бұрын
100% fake
@TheTimshady33724 күн бұрын
Would you need higher compression than that?
@deucedeuce15726 күн бұрын
Yeah, that's why he says it's fake at the end.
@RideWhileYouCan24 күн бұрын
That 12 volt water pump is not designed to withstand pressurized gas, these idiots keep posting stupid videos like these that actually dont work.
@rw9r_t4w9r726 күн бұрын
Заснул пока смотрел, и пропустил сам фокус
@alessandrozuin461426 күн бұрын
do you sell assembed one?
@deucedeuce15726 күн бұрын
No, because it's fake.
@masterchief251527 күн бұрын
чел палится с первых же секунд)) если присмотреться, то видно в щель что там две сигареты, одна из которых разделена на части))
@chrisblanchard693027 күн бұрын
YES! Because using a flammable gas as a refrigerant is a GREAT idea!!
@HolyDreamer24 күн бұрын
R-290 (Class A3), R-152a (Class A2), and R-32 (Class A2L) also flammable coolant gas used by heat pump - tumble dryer, refrigerator, etc. BUT can you watch last 30 sec?
@AgraFarmsllc23 күн бұрын
Did you know that Ammonia was one of the first refrigerants used? Propane as well can be used , co2 as well
@Coyote2798128 күн бұрын
I mean, you could make a decent cooling system for cheap ... but using pumps never made sense. The compressor is the only part you cant really avoid on closed loop phase change system. Home made radiators and evaporators, work. Heat transfer to the bottle can be improved a lot by using a thin plastic bag, in a bucket full of alcohol. With the evaporator coil dipped in the alcohol. As for refrigerant, if you filter it correctly lighter fluid (butane) will work fine for close to 0C temperatures.
@michaellion996728 күн бұрын
Wird nie mals funktionieren
@spencerw682Ай бұрын
Why would you waste everybody's time with that? How long did you spend thinking that up and making a project that doesn't work? Show us something that DOES work, unless you don't know anything, but judging by the fact that you use knipex, I'm sure you know about electricity.
@SandyNMSАй бұрын
Fake.... Mini Air compressor use pressure rubber valves never withstand gas high pressure. I've tried it and explodes.
@rosangelamota6508Ай бұрын
É que vc fez errado
@SohimaRiaz17 сағат бұрын
It's not a fake it's a real
@454545georgeАй бұрын
That's NOT an expansion valve. That MIGHT be considered a "metering device". There is a HUGE difference
@timothyfischer5160Ай бұрын
It's called a capillary tube and functions as a metering device.
@timothymerson1243Ай бұрын
Fake people fake videos whyyyyyyyyyyyyyy
@user-ow2kl9oz6eАй бұрын
Induction heat can be used in absorption refrigeration, without compressor
@renelaplanche720122 күн бұрын
CQFD 🎉 UN BON AGREGA C VAS REVENIR EN FORCE ET ENVOITURE PILE POILE 😊Je pense donc……..
@guibischoffАй бұрын
Fake
@AdityaSingh-sv9ntАй бұрын
Sir please use air compressor at the place of water pump
@minhenesАй бұрын
At room temperature buthane pressure is 2.5 bar. The small pump will not be able to turn against such pressure. Also the plastic tubes vonnections leak. Situation changes if you are outside on a cold day. If temperature is 0 degrees centigrade then buthane pressure is 1 bar. So it is at atmospheric pressure. May be it will work then. Or it will whork while there is a cold spot in the system below 0C.
@user-dk7uo2qb7fАй бұрын
Hi not vacuuming sistem. More part there nitrogen.
@user-co4lb5yz1xАй бұрын
How many BTUs does the machine produce?
@FasteddiesinhomerepairАй бұрын
Condenser is to small and no good disapation of heat
@user-ch6hy2cb7sАй бұрын
Доктору Дью на проверку😂
@asma932328 күн бұрын
Все работает. Вот только автор не говорит что пропан также является фреоном R290.