Пікірлер
@SharingTheBreadofLife
@SharingTheBreadofLife 16 күн бұрын
Surprisingly, very helpful video. Thank you brother 👍
@strchannel7873
@strchannel7873 19 күн бұрын
👍
@rafaelsolis6845
@rafaelsolis6845 Ай бұрын
👏🏼👏🏼👏🏼 Gracias 👏🏼👏🏼👏🏼
@ginalyngeverola
@ginalyngeverola 2 ай бұрын
❤makano po
@user-mh1md5ks1v
@user-mh1md5ks1v 2 ай бұрын
كيف اعرف تحمل الكونتر
@RoyPasetes-td2nn
@RoyPasetes-td2nn 2 ай бұрын
Good day Sir just wanted to ask what software are you using for making this very nice example thank you
@Engineer-Samibress
@Engineer-Samibress 2 ай бұрын
Thanks a lot for your time
@techcjaysvideonotebook
@techcjaysvideonotebook 2 ай бұрын
Just my notes actually...
@Engineer-Samibress
@Engineer-Samibress 3 ай бұрын
Thanks for your time
@techcjaysvideonotebook
@techcjaysvideonotebook 2 ай бұрын
My pleasure
@ElTigreFIME
@ElTigreFIME 3 ай бұрын
I love your videos, however, they could’ve been better with the linear electrical diagram as well.
@techcjaysvideonotebook
@techcjaysvideonotebook 3 ай бұрын
Thanks for the suggestion!
@ShafaqIftikhar-pw9ld
@ShafaqIftikhar-pw9ld 4 ай бұрын
Thankyou for sharing this Knowledge!!!!! And the video upload
@techcjaysvideonotebook
@techcjaysvideonotebook 3 ай бұрын
Just my notes, sharing with you friend..
@RobinBloodPK
@RobinBloodPK 6 ай бұрын
this drawing is slightly confusing as you have got the phase cable going from your NC contacts on overload into your stop/start then it comes out as blue (neutral) into the contactor coil. even though you have already put your neutral to A1 side of coil from breaker, I get its just a visual colouration mistake but it is confusing none the less.
@techcjaysvideonotebook
@techcjaysvideonotebook 4 ай бұрын
I will look into that.. Thanks for the comment.
@user-tt1qh1dy3x
@user-tt1qh1dy3x 7 ай бұрын
thanks, so helpfull
@techcjaysvideonotebook
@techcjaysvideonotebook 3 ай бұрын
You're welcome!
@user-kt6mt6gd3h
@user-kt6mt6gd3h 8 ай бұрын
this is not a suitable method as it does not allow low voltage control -their must be a transformer installed to isolate the control circuit.
@jacobkays380
@jacobkays380 8 ай бұрын
It can be a 120v coil on the contactor. So then you can pick power from one leg of your 240. No need for a transformer in this theoretical application.
@techcjaysvideonotebook
@techcjaysvideonotebook 2 ай бұрын
This is just a basic motor circuit demonstrating start-stop control. The same circuit utilized by motor machineries like wood chippers, etc minus the overload relay.
@radhesyambeats..7939
@radhesyambeats..7939 8 ай бұрын
thanks
@techcjaysvideonotebook
@techcjaysvideonotebook 3 ай бұрын
you're welcome!
@rupangchannel888
@rupangchannel888 8 ай бұрын
Thank you 🙏
@saileshchudasamasc
@saileshchudasamasc 9 ай бұрын
When the switch is toggled back, does it reset the timer?
@techcjaysvideonotebook
@techcjaysvideonotebook 3 ай бұрын
yes, it will reset the timer.
@hankosky
@hankosky 10 ай бұрын
Add NC modules to the buttons and run each others power via that. SO if button 1 is pushed, power is not even fed to button 2, if button 2 is pressed, button 1 loses power. If both are pressed nothing happens.
@techcjaysvideonotebook
@techcjaysvideonotebook 2 ай бұрын
That could be done indeed! It will provide protection
@kunalmurmu5931
@kunalmurmu5931 10 ай бұрын
muzey arjan kari chahia
@noumanmemon2360
@noumanmemon2360 10 ай бұрын
which software do you use to draw these drawings please mention here
@venkywithsocial5661
@venkywithsocial5661 Жыл бұрын
super 👍👍
@techcjaysvideonotebook
@techcjaysvideonotebook 4 ай бұрын
Thanks! ESP32 is now the thing.
@garbo8962
@garbo8962 Жыл бұрын
Installed the identical Omron timer for my homemade central vacuum system that I installed in my house 35 years ago. My kids would plug in one of the 30' hoses to pick up a few crumbs and never unplug the hose so my shop vac that I used for it would run for a hour or two. That model is extremely versatile in that think you can use 24,120 & maybe 240 volts for timer coil and at least 8 modes. Time delay on or off and other modes. Had great luck with Omron timers & 2 & 3 pole plug in relays.
@techcjaysvideonotebook
@techcjaysvideonotebook Жыл бұрын
Omron timers are very reliable timers and are found mostly in all industrial plant setup.
@cayenne9625
@cayenne9625 Жыл бұрын
Thank you for this. But isn't the naming for Forward & Reverse interchanged? In otherwards, Left-side contactor is Reverse and Right side contactor is forward. Because the L1 and L3 have been interchanged on the Left-side contactor to enable reverse function. Isn't that so?
@techcjaysvideonotebook
@techcjaysvideonotebook 3 ай бұрын
Forward/Reverse depends on how you see it, or how the machine movement is designed.
@Dan-ip6cm
@Dan-ip6cm Жыл бұрын
Interlocking them, mechanically or electrically, or I do both
@95machine29
@95machine29 3 ай бұрын
Can explain for mechainical?
@techcjaysvideonotebook
@techcjaysvideonotebook 2 ай бұрын
I think what he means by the use of reversing contactors.
@Dan-ip6cm
@Dan-ip6cm 2 ай бұрын
You get a component called a contactor mechanical interlock, it comes in between the 2 contactors and prohibits both contactors being energised at once.
@95machine29
@95machine29 2 ай бұрын
@@Dan-ip6cm thank you
@95machine29
@95machine29 2 ай бұрын
@@techcjaysvideonotebook thank you
@JabirShaikh-wq4lx
@JabirShaikh-wq4lx Жыл бұрын
Nice bro
@techcjaysvideonotebook
@techcjaysvideonotebook Жыл бұрын
Thanks!
@user-du3tg1jj3e
@user-du3tg1jj3e Жыл бұрын
Было бы здорово с субтитрами, с переводом)
@techcjaysvideonotebook
@techcjaysvideonotebook Жыл бұрын
Thanks!