thanks, very useful. replaces one on my let property today after calling few local engineers who stated that they would not touch it as it is an old boiler and they could run into a lot of difficulties. However, you can still replace the DV without taking the electronic penal off, There is is still plenty of room.
@paul_my_plumbs_ukАй бұрын
What is Worcester heat exchanger cleaning tool Geoff??? Not the rasp but the silver one please 🎉🎉
@tomstrutton4351Ай бұрын
Hands down my favourite boiler guy on here…. Straight to the point…not turning a 2 minute video into 40 minutes
@joshd790Ай бұрын
Great video if we did more of this we would be okay with gas boilers
@Stillbusy105Ай бұрын
My compact si goes straight to 3.3d menu option which is minimum output… no option for 3.1a - any idea why? Thanks
@geoffreyneedstraining5856Ай бұрын
The honest answer is I have not come across this on a SI, but I will find out for you.😉
@bahiaharjinderАй бұрын
Hi Geoff, is there some green star compact models you carnt range rate as some dont have the compatible software any help is most grateful
@raul835Ай бұрын
Some have the chip that you can change on the board that is in plastic bag inside boiler casing.. think the chip halves the KW outage of the boiler. So a 30kw one goes to 15kw.
@geoffreyneedstraining5856Ай бұрын
All cdi and si compact software is not the same the difference between the models are the HCM heating control module and the flow regulator later models had a different size water to water plate heat exchanger in the 15 years I work for Worcester I never come across a CDI compact with different software, but the si has different software I think it’s because they were a cheaper alternative to cdi compact Worcester as far as I’m aware did not put this in your manual so the manual you have with your SI would be the same as the CDI compact I hope this is helpful
@geoffreyneedstraining5856Ай бұрын
@raul835 What are you describing? Is the code plug which come with the green star junior which reduce the heating kilowatts not the CDI compact
@plumbertime16 күн бұрын
I’ve had some that don’t give you the option to adjust the max output. Was told it was a software thing
@bahiaharjinder16 күн бұрын
@@plumbertime 👍
@raul835Ай бұрын
Does range rating affect the readings we're looking for on analyser?
@geoffreyneedstraining5856Ай бұрын
The answer is no if you were analysing the boiler then you would be putting the boiler in to chimney sweet mode #high and low fire mode to get your readings all you’re doing is range rating the heating output
@raul835Ай бұрын
@@geoffreyneedstraining5856 Brilliant. Thanks for the upload and response!
@RMRM-mj3skАй бұрын
Thanks again Geoff
@shujabeg76253 ай бұрын
What if you du it on a system boiler?
@shanedownes64304 ай бұрын
Like all the other comments I too would like to thank you for this excellent no nonsense video which has saved the day. Best video on the internet! 🙏
@karolb34884 ай бұрын
Normally should be On or Off mode?
@joncoke82084 ай бұрын
I can never remove the electrode leads without damaging them
@madmaycon25315 ай бұрын
Perfect !!!! Thank you very much for your videos, they are so good and helps a lot especially for new qualified gas engineers like me.
@wrongfixed64375 ай бұрын
Can you help me turn the system off so I can pressure it plz. Thanks in advance
@owenmccusker61575 ай бұрын
U can both these parts by removing the cold pipe done both this way far lass parts removal
@fanyeros1235 ай бұрын
Thanks for the video help me a lot...
@brotherjohnno5 ай бұрын
Great to see you back Geoff, good video as always.
@dmac40975 ай бұрын
Nicely done 👍
@b1h2u3p45 ай бұрын
Any more tips also why worcester 4000 divertor motor is noisy can be a nuisance.
@raul8355 ай бұрын
Yes Geoffrey.. dropping the pukka training
@CommercialGasEngineerVideos5 ай бұрын
Nice one buddy. Keep up the good work. One less fault code to worry about
@b1h2u3p45 ай бұрын
To replace divertor motor is that easy to do as catridge motor has one screw
@b1h2u3p46 ай бұрын
Can you put cleaner in the auto air vent?
@theenforcer26606 ай бұрын
How do you remove the batteries?
@user-yv2lj2oq8m6 ай бұрын
Your vedeo usefully🎉
@Scon-bq3xo7 ай бұрын
What a life saver .Somehow my boiler and control panel had unpaired, this saved me an expensive call out charge. Thanks a lot .
@julianlockyear88247 ай бұрын
Great video thanks 👍
@montvydasklumbys75847 ай бұрын
Don't be fooled by this boiler. Just had it installed 2 days ago and I personally would not recommend it to anybody looking for a reliable product. I didn't choose it because of the price but rather the installers recommended it over the other greenstar models that I initially was leaning towards, like Greenstar 4000. Regardless, 10min after the installation the boiler is dripping water on the front-right corner and is thus loosing pressure. It isn't leaking at the pipe level but rather inside the boiler itself, which makes me think that QA wasn't done right.. Not only that but unlike any other boiler I've had before (And I had 3, including new and old products lilke Greenstar 4000, Vokera 25, Powermax 140), this one is buzzing like a bee. It creates vibrations that travel through the walls and can be now heard in the whole flat, which is extremely annoying. I am now seriously looking into replace this piece of crap and install something more reliable.
@lostinthoughtscalminsilenc81678 ай бұрын
It’s the pcb not pump
@douglaughton76268 ай бұрын
A few days ago I serviced a CDi. Customer said it was humming all the time, even at 3am. I knew it would need a software reset. Found your video and followed it and paused as requested.👍
@Ceri-7778 ай бұрын
Thanks. I'm glad it is only the batteries😅
@user-lw6px3bk3p8 ай бұрын
So what’s the point of the eco button on a 440 or 550?
@waynehardiman54438 ай бұрын
What does the -60- no heating mean
@kamalpatel23048 ай бұрын
£500? And the rest! More like £650-£700!
@sargonsblackgrandfather20728 ай бұрын
Thanks a million for this mate, if you hadn’t put this up on YT I’d be calling someone out for silly money
@jezlucas38789 ай бұрын
I like it
@jezlucas38789 ай бұрын
Hi I seem to always struggle to remove the electrodes on greenstar i . Any tips for this ?
@russellthomas93919 ай бұрын
Can you do a video on lowering the output on the Worcester 1000 . Something I can send to the lads at work every time they ask . I believe it can be lowered by 50% max
@minixtvbox9 ай бұрын
Plastic pipes and rubber hoses
@mukis11759 ай бұрын
They’ve had some help from Baxi 😂
@johnmoore35699 ай бұрын
Clear and concise, thanks
@Goglu1219 ай бұрын
This procedure also works with Buderus Logamax Plus. Just tested. Than you!
@rabbit_bum10 ай бұрын
This fixed my A21 error, thank you!
@betamax999310 ай бұрын
It’s a Baxi with a plastic hydraulic block and did anyone see the PRV? I’d stick with a Main eco compact for the same money and warranty. Oh sorry ‘guarantee’ for you Worcester snobs! 😂
@dwhyte339210 ай бұрын
Cross between a Baxi 600 and an Ecotec
@minixtvbox9 ай бұрын
Stick to metal baxi
@tspirit9910 ай бұрын
I love you!
@BobaSolo10 ай бұрын
Do you open the valve or keep it closed when its fitted though ?
@Stillbusy10510 ай бұрын
Shame not to show any of the connections, does it come with fill loop etc as installers will be installing them rather than removing the combustion door etc