Why is it ok to connect feedback signal to the plug in module which is non safety rated ? Also how does a test output signal work for the EStops ? Does it go low intermittently to confirm estop not bypassed ?
@Ashishchabha26 күн бұрын
In omron edge monitor tab is used to monitor this. In studio 5000 do we have this feature?
@zhuj.y.8903Ай бұрын
In the Tuning procedure, is the motor remaining uncouple or couple with gearbox and machinery? When we change a new motor or new inverter or change a new power cable, should we repeat the tuning procedure?
@vinicius464ableАй бұрын
Thank you very much from Brazil
@isaiahterhide809Ай бұрын
Thank you Prof
@spk7054Ай бұрын
SFC Chart Step in function it differnce or similar with about State Diagram ?
@spk7054Ай бұрын
I love this lab envenroment here.
@jihadbenouttas3702Ай бұрын
Thank you for this training
@MichaelHoyt-MulticraftTechАй бұрын
What is your stance on function block?
@josephokray763Ай бұрын
I don't usually comment but that tip of WHERE to find the zipped file went a long way. Thank you so much PLC Professor
@sridharpathipaka-xt5umАй бұрын
Hello Professor, to operate the simulator, does the CCW version also needs to be v12?
@parkermizeАй бұрын
I stumbled across epistemology a couple years ago. I appreciate the video. I've found peace with the teachings of Orthodox Christianity. God bless your channel!
@ettorepan2 ай бұрын
Bella spiegazione, c'è tantissima confusione su come funzionano questi sistemi software e questo video risponde a tante domande, grazie per questo video, mi hai aiutato a comprendere RSLogix per il mio corso di studio.
@caltransplant2 ай бұрын
Wrong. Simple as that. Monitor...the device...what your wrong on is how the device is monitored. The device can me monitored, logged, and trended easily in HMI code and (importantly) arranged logically as to function which may or may not be how/where it was written.
@EndrChe2 ай бұрын
For some reason, yt’s grand algo has never led me to your videos, but I am so grateful to have found them now. Thank you for the gift of knowledge.
@CharlesDybala2 ай бұрын
So many of the online PLC training courses the instructor is just a programmer but has no training on how to teach and how people learn. Do you have any certified training on how to teach and how people actually learn?
@NAAJIIRASHAD-hl4pd2 ай бұрын
❤❤❤❤❤❤❤❤❤
@frihyounes71792 ай бұрын
thank you very much your videos really help
@TimWilborne2 ай бұрын
I enjoyed this video Tim
@iliapopovich2 ай бұрын
I was just 10 years old when I had my first interaction with automation. It was with BASIC on 8bit PC in 1984. Actually, it was my mother's second husband to explained how to connect all the el. appliances at home to the computer and control them. When I started the PLC course I was somehow disappointed in the ladder logic as was already programming Arduino on C++ which is much easier. But a couple of weeks later I understood that is much more important to understand the ladder logic especially the relay logic which actually is based on Boolean algebra. In my opinion, if you don't know what are logic gates and binary system there's no point in losing your time trying to be a professional PLC programmer.
@DanielGomez-yz1mw2 ай бұрын
link please?
@OpuSupO2 ай бұрын
Where can I find this Course. Ive been looking for a Training Program to further my PLC knowledge and Ive heard good things about SolisPLC. Could tou provide a linkbto the Course. Thanks.
@RufusPretorius2 ай бұрын
🙏💯
@NeonGreenT2 ай бұрын
Your whole point around ST being worse than LD is demonstrated on like the simplest hello-world a PLC can do. Your standpoint is like from 30 years ago, things have changed alot! Also you picked a manufacturer which is not capable of live debugging ST, which is not ST's fault. I can see the variable value live and can change it by a single click or force it with 2 clicks on a beckhoff system. Even your big statemachine in the main POU does almost nothing other than setting some booleans. how would you even begin to iterate over some 1000 structurized member array ? - oh wait you guys would copy paste the same logic a thousand times. Have you even mentioned breakpoints ? Or is your plc also incapable of that? With no word you mentioned the extended IEC-61131 object-oriented ST, which to me is another sign that even if you did program BASIC or FORTRAN years ago, you don't actually really get how modern PLC is/could be programmed, or do you know what an Interface-POU is and why it is used? The only point you have is that electricians won't be capable of debugging ST code, which is kinda true. But then again, try to program a modern big machine on like LD, it is gonnna be a nightmare and you cost way more than any electrician trying to fix ST logic. And if ST delivers faster, most companies will take ST-coded machines.
@00TheD2 ай бұрын
❤❤
@Nicofish20233 ай бұрын
13:41 we will read 0 1 2 1 1 1 instead. Thanks 🙏
@therobson02013 ай бұрын
Thank you 🙏🏽 🇧🇷
@thycattuongtran98853 ай бұрын
❤❤❤
@Nur_Md._Mohiuddin_Chy._Toha3 ай бұрын
👍👍
@xavimdz3 ай бұрын
The best!!!! Love u
@timkloehn98873 ай бұрын
rs500 is legacy software at this point. Studio 5000 is the standard nowadays, highly complex, and very expensive. I had to learn C# just to get a full grasp on studio 5000. Rs500 is the template to start with, not CCW or 5000 in my opinion. I really only see 1400s or 1100s in the field today, but still they are legacy.
@yyyyyy32823 ай бұрын
Totally disagree! LD is good when machine is simple. However, modern machines are so complicated making LD unsuitable for the job. The reason technicians can't troubleshoot ST is because they are not trained to read ST. I worked with many European and Chinese technicians. They all understand ST and are good at it too. Hence, nowadays there are many tools and IDEs that make troubleshooting code easier. In addition, to improve code quality we can implement unit test, regression test, automated test with ST. For example, after code change, I can let the computer run tests overnight and see how many of them failed. Can LD do that? Also, I can track my changes using source control instead of change the project name to V1.1 V1.2 V1.3... My team members can develop other features without affecting my work and we can merge our code once they are completed. How can I achieve that with LD?
@kootzie3 ай бұрын
what to do when the io modules do not exist in the catalog I am using a 5069-L320ER CPU I see two ethernet adapters A1, A2 when I go to New module, and look for 5069-IB16 or 5069-OW16 etc none of them are in the catalog I don't see anywhere to update the catalog. Yikes... seems rinkeydink amateurish considering the cost of this stuff
@samalfellah20663 ай бұрын
the build process was fun
@sulingli55173 ай бұрын
The best I ever seen to config the communication. Thank you!
@TjipzPK4 ай бұрын
I just have a simple input output program, but I keep getting the watchdog error. Even when configuring the affinity.
@jeffegg24 ай бұрын
I've worked on panels that were all relay logic.... relays latches timers motor contactors.... it was a lot of work.
@ratrod474 ай бұрын
I am interested in this system please share more info and videos.
@user-gm6dw8bu6d4 ай бұрын
Hi, I would like to check with you if my drawing that I made for the CR30 is correct to use in 2 channels at the same time to have the possibility of controlling each one separately.
@tawandasingizi56314 ай бұрын
Please leave it. It s quiet interesting. Just create a playlist for these vidoes.
@simranpreetsingh21534 ай бұрын
thankyou so much for this I am learning alot.
@larmo56334 ай бұрын
You don't happen to fix the control master throttle controller do you? I have 2 units, iv narrowed it down to the hand held throttle as being bad..I plug in one remote and the trains run fine, I plug in the other and nothing, the direction work on it though as I can hear the relay switch over in the power box..and, the momentum light illuminates..but nothing from the pot ..
@plcprofessor4 ай бұрын
I built this for a friend, that is the limit of my involvement.
@anelectrician4 ай бұрын
An excellent presentation . Thank you .
@josiahlocklear22444 ай бұрын
Very interesting had my full attention
@lalithakumari96334 ай бұрын
Your lectures are fantastic
@plcprofessor4 ай бұрын
I meant to upload this to another of my channels, P48. I will remove it and if interested, you can access it at P48.
@user-dw5yb4me6l4 ай бұрын
THANK YOU
@paschadmlz66114 ай бұрын
Sir, how to reset the relay, if this relay indication fault alarm,please i need you answer🙏