Looks interesting. The videos are so short for such a course. If you can remove the background music; this will make it better to understand the concepts.
@felipegames21310 күн бұрын
Very good!!!
@electricalengineeringplane662010 күн бұрын
thank you for your support
@lanzrilpangilinan827211 күн бұрын
Hi I'm from the Philippines, I wanna know the difference between ampere trip and ampere frame of the circuit breaker ...thanks and more power.
@electricalengineeringplane662010 күн бұрын
@@lanzrilpangilinan8272 welcome to my channel and thanks for support ❤️❤️,, you can watch this video and you will understand completely frame current and rated current kzfaq.info/get/bejne/fc2WoNqIq8CYY3U.htmlsi=X1WYN50hOWPsb9Y2
@JhallaSinghSandhu12 күн бұрын
❤
@0786RICARDO19 күн бұрын
Thank you for the accurate and educational video
@electricalengineeringplane662019 күн бұрын
Thank you for your support 🙏❤️
@suheladesilva293321 күн бұрын
Brilliant video, thanks a lot.
@electricalengineeringplane662021 күн бұрын
You're welcome,, thank you for your support ♥️🙏
@MohamedMostafa-js5oq22 күн бұрын
👌
@electricalengineeringplane662022 күн бұрын
🙏🙏
@hosammohamed7528Ай бұрын
Great 👍 ❤
@electricalengineeringplane6620Ай бұрын
❤️🙏
@sandiegarland6132Ай бұрын
Hi, in the example, the TV is rated 150 watts so consumes 150 watts of instantaneous energy, does this mean 150 watts is consumed every second that the TV is on for?
@electricalengineeringplane6620Ай бұрын
Yes that is true، but it's better to multiply it with hours, to have watthour, because any bill you will calculate will be in watthour times the tariff
@humphreyshapi4709Ай бұрын
Excellent 👏🏾
@electricalengineeringplane6620Ай бұрын
Thank you for your support ❤️🙏
@lesegogareseitse392Ай бұрын
It has its advantages too where the ash particles from the boiler are ionized and use the hammer to lower them to the ash tray where they can be removed from the boiler. In power generation
@electricalengineeringplane6620Ай бұрын
Thank you for your great information ❤️🙏
@hosammohamed7528Ай бұрын
Excellent pro ❤❤👏💪
@electricalengineeringplane6620Ай бұрын
❤️🙏
@wyngreece7Ай бұрын
Could you add a dimmer?
@electricalengineeringplane6620Ай бұрын
It's not a good idea because it lower the efficiency but in case you need that you have to buy a special ballast
@wyngreece7Ай бұрын
Thank you!
@GuillemoreGatabАй бұрын
Hello i have a high pressure sodium lamp. i can't use it anymore because if i put a new bulb it blow the bulb. can u tell me what is the reason of burning out the bulb?
@electricalengineeringplane6620Ай бұрын
you have mention lamp and bulb which are the same?? do you mean with lamp the complete fixture?!
@miamiholliwoodmiamiholliwo9192Ай бұрын
Nice explanation
@electricalengineeringplane6620Ай бұрын
Thank you for your support ❤️🙏
@user-lc4nk2js2tАй бұрын
clear and simple explanation, thanks a lot
@electricalengineeringplane6620Ай бұрын
Thank you for your support ❤️
@user-rf8nm7um6xАй бұрын
我的擅长
@incrediblemichaelАй бұрын
faults in the oil ? the bucholz relay senses gas accumulation caused by a fault in transformer windings between windings or a dead short circuit the gas produced by this faults are accumulated inside the bucholz relay and this gases actuating floats the floats ativating a alarm aswwell turning off the faulty transformer through safety devies explain it right thank you
@electricalengineeringplane6620Ай бұрын
excellent thank you for your information ❤️🙏
@incrediblemichaelАй бұрын
@@electricalengineeringplane6620 you are very welcome as a small hint you can look the function from a bucholz relay up in wikipedia smiles
@iulicasmecherie6176Ай бұрын
how do I know what capacitor size to use?
@electricalengineeringplane6620Ай бұрын
For 400watt HPS lamp you will buy cap/hps400 ,, for 1000watt HPS lamp you will buy cap/hps1000
@electricalengineeringplane6620Ай бұрын
Size of capacitance for cap/hps400 is 55 microfarad
@mrtechie68102 ай бұрын
Can I use it for low voltage wires and devices like 12VDC and 48VDC?
@electricalengineeringplane6620Ай бұрын
You can use it in only on condition!! First be sure that the cables isn't connected to any devices,, second the cable insulation rating must be 300v for example to megger it with 250v test
@hamoudi_d2 ай бұрын
Just for the files: Face masks won't protect you from Corona discharge! 🤣
@electricalengineeringplane66202 ай бұрын
True 🤣🤣
@arthurand34302 ай бұрын
You assume P is constant for before and after situation but actually is the S constant - P is changing with the Power factor changing
@user-lo1dk7ok4f2 ай бұрын
You know your motors, thanks very much for a great channel.
@electricalengineeringplane66202 ай бұрын
Thank you for your support 🙏♥️
@anastasfrank1572 ай бұрын
What a peculiar accent
@amraxtagiyev70172 ай бұрын
if we find the power again, what is the first thing for?
@H750S2 ай бұрын
So if the nameplate of a motor shows 100W, power factor and amperage rating. Is that 100W just the active power and not the apparent power? This subject has always confused me but your videos are helping me understand things a bit better so thank you.
@electricalengineeringplane66202 ай бұрын
Thank you for your support <3 the answer is yes 100w is the active power,, and you can use it along with power factor to calculate the apparent power
@H750S2 ай бұрын
Gotcha, thanks for the reply
@kassimo96312 ай бұрын
good job
@electricalengineeringplane66202 ай бұрын
Thank you for your support 🙏❤️
@dreamyfairy52662 ай бұрын
How much voltage does it take? (Please answer 🥲)
@electricalengineeringplane66202 ай бұрын
Can you clarify your question?
@dreamyfairy52662 ай бұрын
@@electricalengineeringplane66209V battery?
@dreamyfairy52662 ай бұрын
@@electricalengineeringplane66209V battery?
@dreamyfairy52662 ай бұрын
@@electricalengineeringplane6620 Is 9V good for this circuit?
@hendrixsun93722 ай бұрын
Hence Covid 19 now the vaxed carry the payloads hence the noises they emit on ham Radio. Balancing payloads on persons as persons have no human rights. You all best fight for the right to be human then worry about rights.
@nasrahmed90933 ай бұрын
As shown in curves it take a specific time to trip, moreover why we are choosing the MCCB rate current to be equal 1.25 full load? As example: heater current = 12 Amp MCCB ==> B16
@electricalengineeringplane66203 ай бұрын
Thank you for your question 😊 we increase mccb rating current for protection purposes,, to take into consideration the temporary overload current and inrush current
@aadilandrabi25043 ай бұрын
kzfaq.info/get/bejne/mql2h8ynlrbOd6s.htmlsi=mk9v4dviKPvJBUYX Why Power is three times more in delta than star connnected load. Subscribe KZfaq channel
@copierkats2073 ай бұрын
Where do you buy that contractor you illustrated?
@copierkats2073 ай бұрын
I mean contactor
@aniketankush2183 ай бұрын
Very helpful!
@electricalengineeringplane66203 ай бұрын
Thank you for your support ❤️🙏
@coilexuscl3 ай бұрын
Superb explanation!!!
@electricalengineeringplane66203 ай бұрын
Thank you for your support ❤️🙏
@feilisong243 ай бұрын
leetcode?
@UmitSeyhan753 ай бұрын
Why there was no operational symbol on the second mcb?
@mohsenfazeli13553 ай бұрын
کمک های معیشتی
@electricalengineeringplane66203 ай бұрын
Thank you for your support 🙏,but can you write in English ❤️
3 ай бұрын
Engineering is never boring.
@electricalengineeringplane66203 ай бұрын
Sure, thank you for your support ❤️🙏
@educationaltechnology83633 ай бұрын
valuable information thank you
@electricalengineeringplane66203 ай бұрын
Thank you for your support 🙏❤️
@jovanyocampo81523 ай бұрын
3 phase how to install in 2phase
@italiarican20063 ай бұрын
In the explanation you mixed up X2 and x3
@lulianalove3 ай бұрын
Thanks for your clarity in delivering the issue I am expert in this field however I shifted to another field and now I am back trying to catch up; you brushed out a lot, well done. I have one question why in the switch example you tested it while the switch On ? is it safe?
@electricalengineeringplane66203 ай бұрын
Thank you for your support 🙏❤️,, you can apply the test safely when the switch is away of the power source,, the problem when you test it when it is energized
@jrapplefan22313 ай бұрын
What is the difference between 3 wires and 4 wires for a PT100 ?
@martinsking41414 ай бұрын
Weldon, your explanation helped.
@electricalengineeringplane66204 ай бұрын
Thank you for your support 🙏❤️
@aaronwebb56834 ай бұрын
In reality the 100 bulb is brighter
@electricalengineeringplane66204 ай бұрын
100 w bulb is brighter in case of parallel connection
@JonDeth4 ай бұрын
*The cost difference really adds up if you are ordering quantities of 50 to 100 or most obviously, 1000 each in a wide variety of values. I also greatly dislike working with 1/8 and 1 watt resistors. In a lot of D.C. circuits, 1/8 watt are perfectly fine, but if you are using perfboard, I personally find them unpleasant to work with.* Installing 1/8 watt on a PCB wouldn't be a significant hassle, but I would personally still dislike using them.
@electricalengineeringplane66204 ай бұрын
Thank you for your fruitful discussion ❤️🙏
@manout-kidin87354 ай бұрын
So a C16 MCB will keep working if 16amps current drawn by a AC stabilizer (100% rated current load @ 230 volts ) runs through it day n night 24*7 ( in case of inverter AC ) & will only trip when amps exceed 10 time the rated amps (short circuit ) or voltage drops ( below 200 volts ) and AC stabilizer starts drawing more amps causing overload situation right ?
@electricalengineeringplane66204 ай бұрын
Yes that's right, if current exceeds 16amps (let's say 18amps for example) after a time that you can calculate on the curve the breaker will trip, this increase of current could be because of drop in voltage or increase of load(power)