ATS Repair  (Tagalog version)
14:20
28 күн бұрын
Deye 3phase Assistance 20kw
21:07
Huawei Fusionsolar app
2:47
2 ай бұрын
Solar Talk With Deye Gti inverter
11:30
Kilowatt Size of wire(tagalog)
13:46
Three Type of Solar Setup (Tagalog)
14:44
Ct Sensor Positioning
8:23
10 ай бұрын
20Kw Deye Grid-tie installation
5:06
3phase Troubleshooting Experience
14:01
Deye 3phase LV Eastron wiring
12:16
New Deye Battery sample test run
8:35
Пікірлер
@aidamacayan430
@aidamacayan430 4 күн бұрын
Natural if Ang setting ay 30% dn pa lng mg charge Ang generator...
@k3mylois
@k3mylois 7 күн бұрын
May tanong po ako. Pwede po ba na ang gagamitin na pinakabattery na ikakabit sa Deye para gumana kahit off grid ay solar generator like Bluetti?
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 7 күн бұрын
Kung Bluetti for generator input charging ng battery pwede.. but for Ac couple not sure kung may protection ang bluetti..
@renepadua6401
@renepadua6401 8 күн бұрын
Sir pwede b ako mkahingi ng parameter settings ng 12kw deye 3phase 220v. Kung ok lng po sir
@kumbatichannel8251
@kumbatichannel8251 9 күн бұрын
Solid subscribers and viewers sir from Cebu province. My tanong lng Ako sir.compatible bah Ang 600w solar panel sa 6kw hybrid inverter deye sir?
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 9 күн бұрын
Don't look for compatibility! Look for PV ISC versus IMP of inverter.. May panels na pasok Kahit 600w na..
@kumbatichannel8251
@kumbatichannel8251 9 күн бұрын
@@solar_isangpinoytech.6328ok po sir.thank u po.
@kumbatichannel8251
@kumbatichannel8251 9 күн бұрын
@@solar_isangpinoytech.6328 Sa 6kw deye hybrid sir. Saan nka point Yung arrow sir?,going to grid or going to inverter sir?
@kumbatichannel8251
@kumbatichannel8251 9 күн бұрын
@@solar_isangpinoytech.6328 Ang ISC ng solar panel sir ay 15.9.tapos Yung IMP ay 15 sir.pasok bah sa 6kw deye hybrid sir?.Hindi ko alam specs sa 6kw sir.
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 9 күн бұрын
Going to grid
@kumbatichannel8251
@kumbatichannel8251 9 күн бұрын
Sir magandang Araw Jan.
@Ultronize
@Ultronize 9 күн бұрын
idol bakit yung deye namin hindi ko na mabago sa touch screen yung max solar power, max sell power, zero export power, simula nung nagremote ako sa online 😅
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 9 күн бұрын
Unlock first.. password 7777
@Ultronize
@Ultronize 10 күн бұрын
Thanks for sharing idol.
@mauribengarlejo9052
@mauribengarlejo9052 11 күн бұрын
Boss may messenger kaba pra ma pm kung time of use parameter ko😊
@MrJeonard1985
@MrJeonard1985 12 күн бұрын
may store kayo sir
@julesandrewdamasco4210
@julesandrewdamasco4210 15 күн бұрын
Laking tulong.Pagpatuloy mo lang mga vids mo sir.Salamat
@angelotv735
@angelotv735 15 күн бұрын
Sir good evening sa 10kw am2 po GTI saan po doon i tap ang ct sensor if walang eastron meter?salamat po
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 15 күн бұрын
485-A&B ang eastron Ct sensor pinaka dulo may nakalagay limiter
@Ultronize
@Ultronize 16 күн бұрын
100% tama sir, 9x2 strings pareho orientation, kalahati lang panel ma shade 900watts ang nawala sa isang string.
@Ultronize
@Ultronize 16 күн бұрын
sir ilan max load ng eps sa deye 8kw?
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 16 күн бұрын
80% max for offgrid mode
@angelotv735
@angelotv735 20 күн бұрын
Good day po sir..kailangan pa ba mag set ng master at slave if 3 parallel na GTI at paano po?
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 20 күн бұрын
using one eastron meter klangan nakaset sa master at slave ang inverter Kapag Individual ct sensor kahit hindi na i set..
@dextercadiente6968
@dextercadiente6968 23 күн бұрын
Hi Sir May FB Page po kayo? or pano po kayo macontact?
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 20 күн бұрын
facebook.com/richard.oliveros3
@aicollectioncorporation6193
@aicollectioncorporation6193 23 күн бұрын
paano po ang wiring ng Eastron meter limiter kapag naka parallel ang 2pc 10kw deye on grid inverter? May video po kayo kung paano isetup ung bagong limiter ng DEYE?
@etv4075
@etv4075 23 күн бұрын
sir, ask ko lang, yung fan ba ng 10kw deye on grid inverter, tahimik lang..or hindi talaga umaandar?
@EdgarBravo-es8um
@EdgarBravo-es8um 24 күн бұрын
paano ba ang warranty sa service sir ilang months
@itzwinplaying
@itzwinplaying 27 күн бұрын
Hi Sir, meron ako F20 Error, pero sabi Installer dahil low voltage daw coming from AC grid kasi 209voltage lang, ano best po gwin? Salamat po.
@toots3020ph
@toots3020ph 27 күн бұрын
Sir sa grid hz high and low ano po ba correct setting?
@nolilandovelo5807
@nolilandovelo5807 27 күн бұрын
Sir Richard mabuhay ka, your so generous sa pag si share ng mga kaalaman mo..👍👍👍
@cryptoonlycrypto751
@cryptoonlycrypto751 Ай бұрын
Sir mas maganda kung may demonstration sana
@arnoldali755
@arnoldali755 Ай бұрын
Boss pwede po bng mg parallel kh8 walang eastron meter
@josephvergara817
@josephvergara817 Ай бұрын
sir, meron kang diagram ng parallel 2 6kw gti?
@dextercadiente6968
@dextercadiente6968 Ай бұрын
Hi Sir san po sa Set-up menu makikita ung shunt QTY? thanks
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Run Parameters Go to meter then long press!
@archiecastigador
@archiecastigador Ай бұрын
Hm monthly billing ng client nyo Sir.?Done subscribed po.
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Nasa 6 to 7k nlang..
@lourdthewanderer9866
@lourdthewanderer9866 Ай бұрын
New subscriber from Cebu, interested sa mga 3 phase installation
@lourdthewanderer9866
@lourdthewanderer9866 Ай бұрын
Tanong ko lang sir, nasa magkano price range ni eastron para sa 3 phase LV sir? Para sa future reference lang sir.
@charddenosta4720
@charddenosta4720 Ай бұрын
Good afternoon pwede ba ako mag service ng existing solar set up 16kw hybrid wala naman problem pero baka may ma recommend or baka pwede may magawang maganda sa set para mas safe and efficient and set up
@lourdthewanderer9866
@lourdthewanderer9866 Ай бұрын
Kung nag kabit ba ng 3 phase grid tie.. dapat ba naka WYE or Delta connection?
@edwinbriones9387
@edwinbriones9387 Ай бұрын
Ask ko lang po, bakit po kaya humuhugot pa rin ng 100w sa grid kahit po mataas ang harvest... Thank u po
@pazdeleon
@pazdeleon Ай бұрын
Sir I have a DEYE SUN-10k-G (grid tie), how many strings of PVs this inverter can hold? currently i have 2 strings connected of 5-550w panels each. I plan to add another 2 strings to max the harvest. If i can still add 2 strings, can I use higher capacity rating PV, like 680w 0r 720w? my roof cant hold many more PVs that's why. thanks!
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Big NO for 680 or 720! Be careful of the current of this biggest panel..check the ISC! If you have already 2 string.. just put to the first mppt, then you can add again 5×550 on second mppt! Another 2 strings!
@erwintagalo5579
@erwintagalo5579 Ай бұрын
Magkano po yung micro grid tie na enphase sir
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
You can contact Brills company for the price..
@erwintagalo5579
@erwintagalo5579 Ай бұрын
Sir ito po ba na model sa endphase is On grid ang off grid na
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Just Grid-tie!
@humbeym4878
@humbeym4878 Ай бұрын
sir di ba pedeng magpalit ng CT may case kase na bundled conductor di kasya ang kasamang ct ng eastron
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Pwedeng magpalit basta same ratio! Sa single phase kc maliit lang ang capacity ng sdm120 kaya limitado
@angelotv735
@angelotv735 20 күн бұрын
​@@solar_isangpinoytech.6328sir good day .pag na eastron meter ka wala nabang I set sa limiter ratio sa gti like sa hybrid .or Yung kasama ng eastron sdm120 pareho ng ratio ng limiter na kasama ni deye .maraming salamat.sana mapansin
@PeejayLuna
@PeejayLuna Ай бұрын
baka pwedi sir ma download ang powerpoint? ty
@carlor9121
@carlor9121 Ай бұрын
+Regarding sa Smart meter(Eastron SDM120CTM-40mA (ESCT-TA16 120A/40mA))terminal for neutral(3) and line(4) connection saan po splicing nito sir sa between load side ?or line side or any line basta nakaparallel para sa source of power ng smart meter . Salamat
@MrJeonard1985
@MrJeonard1985 Ай бұрын
sir. may store ba kayo sir
@carlor9121
@carlor9121 Ай бұрын
Sir Maraming salamat very informative sir
@BanayadRides
@BanayadRides Ай бұрын
Hi sir! Ano po ang contact number nyo? Incase I need assistance for commissioning.
@artswithhannah
@artswithhannah Ай бұрын
tnx s idea sir
@humbeym4878
@humbeym4878 Ай бұрын
Anong tawag boss sa pinaglagyan mo Ng CT ung nag biblink
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Eastron Meter SDM120
@humbeym4878
@humbeym4878 Ай бұрын
@@solar_isangpinoytech.6328 bossing ilang piraso limit Ng deye sa pag parallel
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Sa gti suggest ko 3 unit lang ng gti per 1 eastron.. Sa hybrid 16units ang limit
@carlor9121
@carlor9121 Ай бұрын
Sir saan po pwede mag order ng eastron sdm 120 kasi wala available dito sa market
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Supermax or One point solar
@nelsleons2931
@nelsleons2931 Ай бұрын
Anong brand ba yang inverter?
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Luxpower
@aldymcpndg14
@aldymcpndg14 Ай бұрын
Pwede po bang e maximize sa 100 amp ang grid charge sa battery?
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Only acceptable current lang ang pwede sa battery depende sa manufacturer!..pwede din i adjust ang battery charging ng inverter base capacity rating...if you do that mas lalong lalaki ang bill mo sa kuyente..
@allisonvideo3502
@allisonvideo3502 Ай бұрын
Paano po sir mag parallel ng 2 deye grid tie inverter? Tnx
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Pwede magparallel ng two inverter gamit ang 1 eastron at isang ct sensor at maiset ang inverter na master at slave
@allisonvideo3502
@allisonvideo3502 Ай бұрын
@@solar_isangpinoytech.6328 ano po ang specs ng Eastron saan ko po ito mabibili? Tnx
@Ciprianolaurus
@Ciprianolaurus Ай бұрын
thanks, the app wasn't working to set the wifi credentials. It's good to know the local ip of the AP logger 10.10.100.254
@nolilandovelo5807
@nolilandovelo5807 Ай бұрын
Sir Richard saan ba kita pwedeng tawagan?
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
0915 914 0278
@nolilandovelo5807
@nolilandovelo5807 Ай бұрын
Sir nasa california ako pero yung solar ko nasa capas tarlac
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
You can search My name sir Richard Oliveros... my location distance Via SCTEX 1.5hrs Bataan to Capas Tarlac
@nolilandovelo5807
@nolilandovelo5807 Ай бұрын
Sir Richard paano ba kita matatawagan, kailangan ko yung tulong mo.
@Madie970
@Madie970 Ай бұрын
Sir, inquiry lang. If L1 L2 L3 available, wala po nuetral Sa eastron input leave po ba number #3 ?
@solar_isangpinoytech.6328
@solar_isangpinoytech.6328 Ай бұрын
Take L1 and Line 2 or Line 3 for eastron power supply ng LA and NA kahit walang neutral.. leave it and neutral!
@nolilandovelo5807
@nolilandovelo5807 Ай бұрын
Gusto ko sana kayo maka usap para maipaliwanag yung problem ng set up ko.