Vent Hood
1:53
14 сағат бұрын
Junior Inspector Isaiah’s advice
1:01
16 сағат бұрын
Fridge Door Tips
0:43
Күн бұрын
Hot and Cold water
1:25
14 күн бұрын
From BlackBerries to Now
3:22
14 күн бұрын
Garbage Disposal
0:52
14 күн бұрын
Do I really need an Inspection?
2:48
21 күн бұрын
What happens if we miss something
1:58
Our Junior Home Advocate.mp4
1:32
Oven Check.mp4
1:35
Ай бұрын
Mold Vertical.mp4
1:33
Ай бұрын
5 Places We Need to Access
3:04
Пікірлер
@richardcoble9498
@richardcoble9498 3 сағат бұрын
1st the y connection is not correct which is probably the issue the other pipe is to a furnace also the make up air at the bottom of the water heater may be clogged there is a screen at the verybottom its 2 in tall x the circumfrence of the water heater if its clogged it will not vent properly . The water heater flue has a correct rise the flue should be as straight as possible who ever instalked it should of moved it over about 6 in to remove the 60 bend rt before the y connection. Still my gess is make up air problem. Also looks like its venting into a chemney todays codes there should be a sleeve going to the top of chemney with a cap & cover over the top of exit though it doe vent carbon monoxide its call combustion gases.. geez
@f1ghtkn1ght95
@f1ghtkn1ght95 Күн бұрын
Your door switch in your dryer is busted or someone bypassed it
@BadCactusJones
@BadCactusJones 2 күн бұрын
Yeah my photo eyes definitely work. There just on the beam above motor. I just wanted to be able to press the button and walk under the door like I could before.
@mattwayne5013
@mattwayne5013 5 күн бұрын
Why are you messing around with peoples hair with your bare hands lol
@bt1959
@bt1959 6 күн бұрын
In MO I found a house with the load bearing studs cut off to the slope of the roof and decking nailed directly to it without a top plate or rafters/trusses. They built spray foam gussets.
@TheBedtimeVIP
@TheBedtimeVIP 6 күн бұрын
Holy
@PoopEaterr_27
@PoopEaterr_27 8 күн бұрын
Great content!
@BumMilkSandwhich
@BumMilkSandwhich 8 күн бұрын
Home inspection? Doesnt mention that absoloutly MASSIVE crack in the wood the door is attached too.
@vr4runner
@vr4runner 13 күн бұрын
Call a real plumber
@johnwilliamson-zj2dt
@johnwilliamson-zj2dt 13 күн бұрын
Aren't you a plumber?
@ElevateHomeAdvocates
@ElevateHomeAdvocates 12 күн бұрын
We are definitely not plumbers! 😉 As home inspectors, we often run a sewer scope to educate our clients on what they are inheriting all the way out to the city. More often than not, we run into something that needs a qualified licensed plumber. Let us know who your favorite plumber is! We love to connect great people with our clients.
@shexdensmore
@shexdensmore 14 күн бұрын
Damn, I know that was a pain to install
@UKsystems
@UKsystems 16 күн бұрын
Is it important to know that if you have identified issues on city equipment you should really be reporting it to them
@samueljones-bankston7853
@samueljones-bankston7853 16 күн бұрын
How do you know if it falls on the city or not? Does it have to do with where the damage is?
@UKsystems
@UKsystems 15 күн бұрын
@@samueljones-bankston7853 well, it’s an electrical line coming from a pole so it’s probably the city before the meter or the electrical company or something along the lines yes you could run your own overhead line, but I would say it’s pretty unlikely in this case
@marvinpage4624
@marvinpage4624 28 күн бұрын
Why, don't care
@drl5002
@drl5002 29 күн бұрын
And yet the lines on the poles can still not have sheathing and we just rely on telling people not to touch them.