Пікірлер
@Trackman80
@Trackman80 Күн бұрын
I learned absolutely nothing
@up2paar
@up2paar Күн бұрын
Congratulations 👏
@wellhmm1193
@wellhmm1193 2 күн бұрын
Pretty cool man
@stevewhewell6190
@stevewhewell6190 2 күн бұрын
You can't put a 20 amp receptacle on a 15 amp breaker.
@up2paar
@up2paar 2 күн бұрын
Yes, absolutely not
@bman6502
@bman6502 Күн бұрын
Why not?
@nickgarafolo9359
@nickgarafolo9359 2 күн бұрын
Just read the code book it has a table
@nickwalters3478
@nickwalters3478 3 күн бұрын
Nope. I’ll put an inside the pipe trap adapter right there in the San t. Never had an issue. The vent is right there to prevent any issues
@stevea2488
@stevea2488 4 күн бұрын
So you like to make youre plumbing jobs cost twice as much. You don't need 2" for your vents and drains unless your wet venting.
@up2paar
@up2paar 4 күн бұрын
Well 2" isn't twice the cost.
@mrl22222
@mrl22222 4 күн бұрын
the actual measurement is taken where the flow direction changes, so typically that will leave about 2.5 inches of exposed pipe, not the 4 inches you show.
@donaldblank8873
@donaldblank8873 4 күн бұрын
Finally someone that doesn't need to guess.
@yvettejimenez3471
@yvettejimenez3471 4 күн бұрын
You are amazing you help me alot thank you so much❤❤🫶🥰♥️👍💪♥️❤
@dudeman579100
@dudeman579100 5 күн бұрын
not because of siphon. its the risk of clog.
@justaskmike4602
@justaskmike4602 5 күн бұрын
That’s allot.
@up2paar
@up2paar 5 күн бұрын
Just following code
@ironicalitis1048
@ironicalitis1048 5 күн бұрын
Rhode Island people
@stevenseagal4987
@stevenseagal4987 6 күн бұрын
never had to do this (yet). in residential new construction. Thanks for the future tip!
@jamesyarbrough4777
@jamesyarbrough4777 8 күн бұрын
you stubb out 2inch for a vanity?
@ptech88
@ptech88 9 күн бұрын
Have had my own plumbing company for 40 years and have never once seen a trap lose it seal because of this.
@MikeySkywalker
@MikeySkywalker 10 күн бұрын
Nothing worse than the smell of an uncapped drain.
@up2paar
@up2paar 10 күн бұрын
Its new construction not connected yet
@lanniedulin1075
@lanniedulin1075 10 күн бұрын
How’s compare to Milwaukee or makita
@up2paar
@up2paar 10 күн бұрын
Much lighter and faster
@lanniedulin1075
@lanniedulin1075 10 күн бұрын
They sell spacers $8
@gmilla2825
@gmilla2825 11 күн бұрын
There’s such a thing as “minimum size for maximum drainage “ and man, those joints look terrible
@aviatortrucker6285
@aviatortrucker6285 11 күн бұрын
Multiple circuits as let’s say the entire living room outlets, no more than five on a circuit can be on 20 amp circuit with 12 gauge wire. Use 15 amp outlets because they’re cheaper when you are contractor and have to buy like 100 or more of these devices.
@M13x13M
@M13x13M 13 күн бұрын
Non-serviceable p trap?
@up2paar
@up2paar 13 күн бұрын
Never use a non-servicable under sink
@NewOrleansNick
@NewOrleansNick 13 күн бұрын
BULLSHIT!!!!!! Don’t believe that. You can cut it how ever long you need it AS LONG AS ITS GOT A PTRAP AND ITS VENTED RIGHT THATS ALL YOU NEED!!!!!!!!!!! That’s why we don’t always glue the stub out peice going through the wall bc if it’s short enough we glue the trap adapter right into the tee….
@anthonyrivers8395
@anthonyrivers8395 16 күн бұрын
YES
@wmuckbangs4870
@wmuckbangs4870 16 күн бұрын
Not trying to be a smart-ass but what would happen other than a failed inspection
@up2paar
@up2paar 16 күн бұрын
More than that, the breakers would not lock in and yes a failed inspection. Every contractors goal is too pass the first time
@bryanherman1035
@bryanherman1035 11 күн бұрын
Nothing. Seimens breakers work fine in these panels. The only difference between the two is the brand name. The construction and function of the breakers is exactly the same.
@trentbonebrake8160
@trentbonebrake8160 10 күн бұрын
Good luck getting the panel cover on with that arc fault breaker
@up2paar
@up2paar 10 күн бұрын
Fits like a glove
@lifeupnorth9385
@lifeupnorth9385 16 күн бұрын
If these are shear walls then you need to block all sheathing seams.
@danielheller577
@danielheller577 16 күн бұрын
You shouldn't drop your sanitary teas on center. They should be off to the side. That way, the trap arm makes up for your Crown venting.
@danielheller577
@danielheller577 16 күн бұрын
3 "
@koreanangellol
@koreanangellol 17 күн бұрын
how put drywall
@darkma1ice
@darkma1ice 20 күн бұрын
Pour out like 1/3 to half of new primer cans and rap the dobber on the can before you use it, it’ll reduce the drips like that
@up2paar
@up2paar 19 күн бұрын
Thanks for the input
@andrey162000
@andrey162000 25 күн бұрын
Just don’t center the sanitary tee with sink center, problem solved, and you don’t screw electrician with lights
@hellersbuildingremodeling7771
@hellersbuildingremodeling7771 25 күн бұрын
I believe with the depth of any sink there is no choice to have the center of trap any closer to the wall than 8” or so - I don’t think this problem could ever exist unless your building your own sink and mounting the drain all the way in the rear
@up2paar
@up2paar 25 күн бұрын
Great point
@cykablyat8513
@cykablyat8513 28 күн бұрын
80 volt.. that's cute
@up2paar
@up2paar 28 күн бұрын
I tried two gas units and both garbage compared to this.
@marlowkenyon307
@marlowkenyon307 Ай бұрын
How do you use that diamond to mark the birds mouth?
@derekmichael9375
@derekmichael9375 Ай бұрын
Looks high
@JimPaar
@JimPaar Ай бұрын
18" is standard
@pcobra5427
@pcobra5427 Ай бұрын
Hatched head
@ChrisHerring-es1yu
@ChrisHerring-es1yu Ай бұрын
Don't see any hoedowns
@trentdawg2832
@trentdawg2832 2 ай бұрын
Its called a weir
@censormedaddy
@censormedaddy 2 ай бұрын
Stub out 4" pvc a few inches above the subfloor, put a test plug in it so debris doesn't fall down the pipe, then wait till the finish floor is installed, cut the pupe flush with the finished floor, then glue in your flange.
@joshual9759
@joshual9759 2 ай бұрын
JUST SAY THE NUMBER ALREADY!!!!!!
@flacdaddy1313
@flacdaddy1313 2 ай бұрын
Less primer more pride.
@jo-dcampbell7508
@jo-dcampbell7508 2 ай бұрын
Yes ive actually installed can lights on a switch for ceawlspace before or just regular pull switch lights help a tremendous amount
@up2paar
@up2paar 2 ай бұрын
Great idea, go Bulldawgs
@twoamigoshvac
@twoamigoshvac 2 ай бұрын
Yes yes yes
@up2paar
@up2paar 2 ай бұрын
Thanks
@StarknightMT_official
@StarknightMT_official 2 ай бұрын
Hello, Are you interested in testing our products? We would like to invite you to test the lift kit for your 2023 Polaris Ranger 570 Full Size
@up2paar
@up2paar 2 ай бұрын
Email us at [email protected]
@StarknightMT_official
@StarknightMT_official 2 ай бұрын
@@up2paar Thank you,we will send the details.
@hepparade
@hepparade 2 ай бұрын
I don't mount the flange until the ff is installed
@hepparade
@hepparade 2 ай бұрын
Drain arm min is = 2x diameter of pipe
@DLB1858
@DLB1858 2 ай бұрын
Try that on a pedestal sink. That has not been an issue since we’ve done away with s traps
@rogermiller8262
@rogermiller8262 2 ай бұрын
Why not install a trap adapter at this point? I like the formula for the length of the pipe.
@CaptnRich737
@CaptnRich737 2 ай бұрын
Because the sheet rockers have to come in and install the rock over the trap arm. If you have the trap adapter installed, that means you also have to have the eschushion ring behind it, and the rockers will hate you forever for making their life miserable.
@donniesutton2230
@donniesutton2230 2 ай бұрын
Code code code.... Sounds like the atm... Plumbers understand plumbing physics abd plumbing theory..... Code code code..... Oh no...
@timothyjerry1177
@timothyjerry1177 2 ай бұрын
Total bs.
@tucsonplumbingcrazy2823
@tucsonplumbingcrazy2823 2 ай бұрын
Easiest way to avoid that is swinging the santee in the wall sideways and ustilizing the one fitting past the santee