To think someone made this and thought to themselves , "Lets start off strong and deafen everyone with an obnoxious sound effect at the very beginning. Ohhh, this distracting animated hand drawing photos and text looks great. Then I'll just top it off with Microsoft Sam as the voice. Last but not least, I will choose the worst text color options for reading onto a blinding white background. Now I have done completely the opposite of the Web Content Accessibility Guidelines; it's Perfect!"
@RandhawaAslamАй бұрын
Normally, in centrifugal fans, air is sucked along the shaft and delivered radially. I have observed that in Split AC, the fan sucks and deliver Air Radially. How? Thax.
2 ай бұрын
I THOUGHT THERE WAS AN EXPLOSION IN THE OUTSIDE CUZ OF INTRO
@gooddeedsleadto74992 ай бұрын
Line ( dome line) represents saturated liquid or saturated vapor? and everything within the dome is also saturated liquid or saturated vapor? And Left & right of the dome is sub cooled liquid and super heated vapor respectively? Please verify? Thank u
@emdadulhoque50042 ай бұрын
Pl give your contact detail to communicate you .
@user-zs4ym2xc9f2 ай бұрын
And in 5 years we get the next new refrigerant. All thanks to this monster called government.
@lindhe2 ай бұрын
Annoying robot voice. 👎
@wtfman53133 ай бұрын
The halting nature of whatever is narrating this course is off putting and distracting. Would love to hear it by an actual human.
@vnesmuonnam3 ай бұрын
Thank you
@AhmedAhmed-lz1ke3 ай бұрын
Aoa.Very knowledgeable Explanation. Thanks
@user-jm4ry6gz1x4 ай бұрын
How many time taken from fully open to fully close in spring-return type?
@zabidi594 ай бұрын
Do like to share this video please.
@dorothykloss53034 ай бұрын
loose the AI and get a real human!
@davidricardo53924 ай бұрын
Why is the table of thermodynamic properties of R32 refrigerant in saturated and superheated conditions not available?
@AviewFromUnder5 ай бұрын
nope!! Will not listen to a bot spouting strange grammar
@pacospete42995 ай бұрын
so i'm seeing folks install these mini split systems ans coiling the access lines next to the outside unit .... is this a problem ?
@goru4262 ай бұрын
Not for R-410a systems. It was a problem with the older R22 refrigerants.
@kas58575 ай бұрын
To get total required louvre area i dont think it is Freaa area x 1.5 but x by 2 as the typical free area of a louvre is 50%. You have already calculated the free area so you simply double it.
@persaudchris21 күн бұрын
Correct, factor of 2 as a lower limit. I've seen most louvers with 40% NFA. I typically would calculate for a factor of 2.5 to be safer.
@user-cm9pv3bo8w5 ай бұрын
You couldn't shell out for an actual voice over? This AI generated narration is truly awful.
@benorddesideri6 ай бұрын
One more Messi moment 😊
@mn.o6 ай бұрын
so nice
@AhmedNasr-nr1kh7 ай бұрын
Thank you for your good information
@bradwhite46507 ай бұрын
Robotic voice is burtal to listen to ... worst explanation ever
@l4knowthescore6697 ай бұрын
so I measures outer diameter on my vernier at 43mm...Does this mean the pipe size is 1-14 inch?
@rzanpc99498 ай бұрын
Where is Carbon filters?
@rcinfla90178 ай бұрын
As liquid enters expansion valve, some flash gassing occurs to effectively cool the liquid down to evaporator saturation temperature. This flash gas does not contribute to evaporator cooling therefore is efficiency loss. Larger amount of subcooling is advantageous for this particular aspect, but ... Higher subcooling reduces condenser effective area for cooling refrigerant hot vapor which exchanges heat to air flow much better than cooled, condensed liquid refrigerant due to the greater temperature difference in condensing hot gas to air flow through condenser. Higher subcooling on output of condenser raises compressor discharge gas temperature/pressure and can increase load on compressor causing more compressor electrical consumption, which is an efficiency loss. Higher SEER units often accomplish their increased efficiency by using a larger condenser. Larger condenser usually holds more refrigerant so there is greater volume of liquid refrigerant margin allowing them to run at lower subcooling levels. Large condensers can cause problems with compressor input flooding in off mode due larger refrigerant system loads. Many systems with large condensers shut down expansion value when compressor is shut down and rely on compressor discharge check valve to trap liquid refrigerant between compressor check valve and shut off expansion valve. Once condenser cools down in off mode, most of liquid will stay in condenser during off mode even when there is some leaking of check valve and shut down expansion valve. This greatly reduces possible liquid flood back to compressor input during off mode by keeping most of liquid refrigerant in condenser during off mode.
@bulldawg62599 ай бұрын
Went by to fast useless info
@zabidi599 ай бұрын
Do like to share this video please.
@DineshDinesh-ug6xz9 ай бұрын
Nice thank you
@user-ut1xv9ji7h9 ай бұрын
What is L & C ?
@eltattooma9 ай бұрын
Many useful information collected in this video. Thanks for your kindly efforts and sharing learning info.
@JDT7381269 ай бұрын
Perfect video on oil traps!
@johnyrockstar00710 ай бұрын
Thanks for taking time to do this
@cb936910 ай бұрын
Highly educational.
@wenshao996610 ай бұрын
is it possible to pay you to help me tocalculate the free area of my louvered door
@irham985610 ай бұрын
👍👍👍
@rcinfla901711 ай бұрын
The wiggling hand is annoying and distracting.
@katuraysalad11 ай бұрын
Thank you for this informative video ❤
@user-ez7rm3hx9g Жыл бұрын
En español sería bueno traducirlo
@iqbalfarook2866 Жыл бұрын
My 1 ton bluestar split has issue like blower is not throwing complete air it stuck in some places. Air flow comes with whzzzz whzzzz sound. I can fell the chillness and cooling. But air out flow from blower stuck in one side. My Ac mechanic told the same u trap. Is the u trap recommended for my issue. I changed outdoor eveporator coil my blower fan is good no issues, I did full water service gas level is also good.
@Mrmoneysaver2024 Жыл бұрын
Terrible video!
@eugen-m Жыл бұрын
Great work ❤❤❤
@kevindick7485 Жыл бұрын
Nice presentation except the hand jive thing . Very distracting .
@char.s1ksmashing444 Жыл бұрын
We dont use 45° fittings in refrigeration. Also inverted p traps are usually installed at top of riser.
@majharulislam5950 Жыл бұрын
Thanks for extraordinary explanation.
@muhasomaa Жыл бұрын
GREAT
@TheKeshav92 Жыл бұрын
Google copy paste video. Not technically strong video.
@Z-Ack Жыл бұрын
Are there auto drainbacks like solenoid controlled with discharge? I know they make em for air compressors but those work with float valves..
@alfredovelez83959 ай бұрын
Typically a check valve on the discharge line of compressor prevents any refrigerant migration