RGF Christmas Extravaganza 2023
2:13
RGF Christmas Extravaganza 2022
1:33
Clean Air is Life
4:28
Жыл бұрын
Clean Air Is Life - Yoga Studios
0:55
Clean Air Is Life - Offices
1:14
Жыл бұрын
REME HALO®Zero
1:21
Жыл бұрын
RGF HOLIDAY PARTY 2021
5:00
2 жыл бұрын
Пікірлер
@jordanfaltysek9957
@jordanfaltysek9957 13 күн бұрын
If you have 2 systems in your home, do you need 2 halo-leds?
@rgfgroup
@rgfgroup 13 күн бұрын
Hi Jordan! Yes, you will need one for each system.
@infamous3059
@infamous3059 Ай бұрын
Someone, please tell me if you have to use the transformer. I have a Goodman ASPT47D14 HVAC unit and my electrician says that it's not necessary to use the transformer. Do you know if this is true?
@searay260sundeckforsale4
@searay260sundeckforsale4 Ай бұрын
Thank you for the video! I was able to install it myself. The supplied rubber hose that came with the air switch is not long enough for both sides (positive and negative) - I only connected the return for now and it works. Question - what is the purpose of connecting both on the air switch - is it mainly for backup?
@justinsmith4839
@justinsmith4839 2 ай бұрын
I do not understand why you need a air switch when this the fan come on the halo comes on pretty simple.
@ezequielcastillo6010
@ezequielcastillo6010 Күн бұрын
Do you find how?
@charlesmorgan2234
@charlesmorgan2234 2 ай бұрын
RGF instructions for relay installation all involve switching the primary side of the supplied transformer on and off. It seems to me that a better approach would be to switch the secondary side on and off (leaving the transformer always powered), similar to RGF's instructions for an air sensing switch. For air handlers that control the blower fan via the G terminal (fan control) only, the G and C (common) terminals could be connected to the relay coil terminals, and either of the transformer's secondary wires could switched via the NO (normally open) terminal on the relay.
@user-wb6rt8dn8n
@user-wb6rt8dn8n 3 ай бұрын
I had one installed professionally by utor services and I can’t thank them enough for telllinf me about it. They clean my air duct with Rotobrush machine and now. I felt my 28 years old home feels brand new .
@kj18230
@kj18230 4 ай бұрын
Is there a performance difference between the Zero and non Zero? Or is it just an ozone compliance push?
@tonymaldooo3429
@tonymaldooo3429 4 ай бұрын
I’m an HVAC technician, and I cannot recommend this enough to all my home owners. This has the best warranty in the game if installed by a professional at 7 years. All the bad reviews are from people who most likely installed it wrong. The Reme LED has to be wired in to turn on or off with airflow. The maintenance is very minimal, and the UV replacement is every 5 years, best in the game as well. It also has an ionizer that’s built into to it, and it will help your filters catch more dust, dust mites, reduce smells, and help with allergies. Highly recommended product, not biased, I base my option on real life reviews from my customers and the data that backs it up! I’m in the Austin area hmu
@AndyTanguay
@AndyTanguay 4 ай бұрын
Does the orientation of the air switch make a difference? In the install manual it seems to be illustrated 180 degrees from this video.
@clarkk1203
@clarkk1203 5 ай бұрын
This is the most legitimate product on the market. If you have air quality concerns RGF products are the best out there
@antonymozart
@antonymozart 5 ай бұрын
Installer claiming my brand new device is faulty. Cannot turn on. But also claiming correct inctalation and wiring on his side. How to check device in this case? (Installed without air switch). Thanks for help.
@hamster82-y
@hamster82-y 5 ай бұрын
Should it be duct mounted or magnetic mounted?
@hamster82-y
@hamster82-y 5 ай бұрын
Should this unit be duct mounted or magnetic mounted?
@thecaliforniaconquestor9485
@thecaliforniaconquestor9485 6 ай бұрын
My company started selling these in totally buying one for my house.
@jx5hficus176
@jx5hficus176 6 ай бұрын
UV LIGHT SHOULD NEVER BE INSTALLED IN A INTERNALLY INSULATED PLENUM!!!!!!!!! UV WILL EAT AWAY THE FIBER GLASS INSULATION
@DV-go9ws
@DV-go9ws 6 ай бұрын
Great video. Awesome that a company actually does this. I as able to complete my self and saved 1000 install fee.
@peacefulnaturehaven
@peacefulnaturehaven 7 ай бұрын
A guy came out and installed one at my house today, but didn’t use a rubber grommet for the air switch hose…just put it through an open hole. Is that going to be a problem?
@markandreas2428
@markandreas2428 9 ай бұрын
Can the HALO-LED unit be install vertically?
@ijajulhoque1159
@ijajulhoque1159 9 ай бұрын
FHAAOGG RGF
@7HEREALDON
@7HEREALDON 9 ай бұрын
How does the product prevent mold growth in the coils in the handler? Ans and does it help people with MCS? Beautiful work btw
@dalynnfloyd7752
@dalynnfloyd7752 10 ай бұрын
Pretty crappy tutorial video to use to instruct people who know none the better-take a look at 2:35 into the video- don't even have it in correct orientation with the air flow direction- do better
@randsipe224
@randsipe224 11 ай бұрын
Excellent video with plenty of detail.
@mounirdarwiche6075
@mounirdarwiche6075 11 ай бұрын
If you’ve never used an air filter these are great. kzfaq.infoUgkx_dppjvjF8BYEmPSDTcgCUdRsgWYLXNHN I ended up with three after starting out with one. The noise level depends on the 1-3 settings with how hard you want the machine to work. You can also upgrade the filters and get one better for pet hair and smells which is a must have in my home. I noticed the air seemed lighter and easier to breathe when running the machine for the first time. Works great every time. Highly recommended!
@CancerCallCenter
@CancerCallCenter Жыл бұрын
Nice…
@calebcromar1947
@calebcromar1947 Жыл бұрын
My unit didn't have L1 what do I do?
@markkasper7281
@markkasper7281 Жыл бұрын
just got one of these units, i dont have sinus issues and i can already tell this product is the real deal, the house smells super clean very refreshing
@Kenpachi69420
@Kenpachi69420 9 ай бұрын
All you are smelling is the ozone that is being created.
@lowstakesriverpirate9273
@lowstakesriverpirate9273 Жыл бұрын
Reminds me of a Mercury Arc Rectifier. kzfaq.info/get/bejne/aNZ0ltlnzJeqdWQ.html
@juliusseizure3039
@juliusseizure3039 Жыл бұрын
Yeah but what they don't tell you is that hydrogen peroxide strips electrons from any element cause it's an oxidizing agent. If you breath in hydrogen peroxide you will cause tissue damage to your lungs and once a cell is destroyed in this way it cannot be taken back. You will slowly be killing yourself if you install this system into your home.
@droptopmaids8474
@droptopmaids8474 9 ай бұрын
Yeah that what I just heard! Bs
@kylegilliano281
@kylegilliano281 Жыл бұрын
can you mount these to duct board securely?
@Evim2020
@Evim2020 Жыл бұрын
Quick question Mike. What would happen if the Halo-LED Barrel Plug gets unplugged? The homeowner installed one of those in the apartment where I live with my family and we've been getting sick often after its installation. The homeowner refuses to uninstall it.
@TheNorthsquad
@TheNorthsquad Жыл бұрын
The UV light isn't what's making you sick, even if it unplugged. Unistalling it would make no difference at all
@selwyn13
@selwyn13 8 ай бұрын
You probably getting those symptoms b/c u have mold which will happen if that UV light is unplugged (assuming it's not hardwired), that outlet isn't working, the breaker for that outlet tripped for whatever reason, if the bulb is burnt out. Shouldn't be the other way around.
@lauraelliott7441
@lauraelliott7441 Жыл бұрын
I just started up my REME HALO again (needed a bulb) a few days ago and, boy, it was good timing. I'm sure it kept me from getting COVID from my husband who was exposed on Saturday (I was with him) and who started showing symptoms on Monday. He tested negative on Monday and positive on Wednesday on a home test (and a retest). I had a negative PCR test on Tuesday and a negative home test today, Thursday. We spend a lot of time in the same space in the house including sleeping together. The AC fan was set to run a minimum of 10 minutes per hour although I have now increased the time. I'm pretty sure I would have gotten COVID from him if we didn't have a REME HALO installed. The unit was originally installed in 2016 for my late mother with COPD and asthma. Yay REME-HALO!
@idealynx
@idealynx Жыл бұрын
Hi Mike, great video! What's the warranty on the unit and will a DIY install void the warranty? Also, is the air switch included?
@tommckelveyiii7714
@tommckelveyiii7714 Жыл бұрын
yes it voids the warranty, no the air switch is not included
@Arctic513
@Arctic513 Жыл бұрын
How is this better than the Nu-Calgon Iwave-r?
@larryfriese
@larryfriese Жыл бұрын
Bought two in December. One of them has already failed. Poor quality for such a high price.
@joelverley
@joelverley Жыл бұрын
We’ve sold hundreds and I haven't had one to fail on a customer yet. Maybe installation wasn't the best. They do have a 5 Year Manufacturing Warranty on them so you may want to take advantage of that provision.
@matthewbeingessner8693
@matthewbeingessner8693 6 ай бұрын
wow!
@All4ChristNone4me
@All4ChristNone4me 5 ай бұрын
@@joelverleyany issues with ozone output? I know they have a zero ozone model. But just curious about the Reme halo
@keaveny63021
@keaveny63021 Жыл бұрын
Excellent video!
@Little_Bitz
@Little_Bitz Жыл бұрын
What's the difference between the zero and the LED version? Why can't I find the answers to this anywhere?!
@luisg1698
@luisg1698 Жыл бұрын
From my understanding the led is of course led bulb. It’s designed to turn on with airflow. And off without airflow. The regular Reme halo is designed to stay on 24/7 that bulb is not led. This new model is basically just a regular Reme halo with zero ozone.( the regular model creates an ozone smell that most people don’t like)
@johnmflores85
@johnmflores85 8 ай бұрын
Its installed wrong
@brianshimp8299
@brianshimp8299 Жыл бұрын
Please ignore my comment below. I spoke in ignorance. I have since contacted RGF and spoke with the man that designs this system. He informed me that some EAC terminals do not put out proper HZ when first coming on and that can damage the REME. He wants all units installed with the transformer powered all the time and break the low voltage to the REME with an air proving switch or relay. He said if you always use the air proving switch, you won't have confusing different diagrams for your techs. Just get the line voltage right to the transformer and good to go. New diagrams may be coming out to replace the current ones.
@mainevents1001
@mainevents1001 Жыл бұрын
For smell, buy a reme-led. It’s an air purifier that goes in your ductwork and kills bacteria and viruses.
@mainevents1001
@mainevents1001 Жыл бұрын
kzfaq.info/get/bejne/iM5kY7iaxLO2knU.html
@mainevents1001
@mainevents1001 Жыл бұрын
Link showing what it is^
@ryanotis
@ryanotis Жыл бұрын
Can you replace the PHIC-RH bulb of a REME-HALO with a PHIC-RH-3 to "upgrade" it to a Zero? Is the rest of the unit the same?
@jenniferericsson6696
@jenniferericsson6696 Жыл бұрын
RGF customer service just told me yes.
@jesusdisciple7343
@jesusdisciple7343 Жыл бұрын
If you connected to L1 which is power always on, how would the halo be control with the fan?
@jeremymorgan7199
@jeremymorgan7199 Жыл бұрын
The L1 is powering the transformer not the halo. The 24V coming from transformer powers halo but you're breaking the 24 with the air switch. Just like a float switch pretty much
@brianshimp8299
@brianshimp8299 Жыл бұрын
Nice video and what you say works, but when Installing the REME LED to a furnace, it is easier to power the transformer from the EAC terminals on the furnace logic board and plug the 24 volt end of the harness into the unit and you are done. No airflow switch or relay is needed on the furnace installation. The furnace logic board is specifically designed to energize the EAC terminals anytime the blower turns on. Air handlers are different because they do not have EAC terminals. Then either the relay or the airflow switch is needed to install the unit properly.
@shanew7361
@shanew7361 Жыл бұрын
Does this work only when the furnace is running, or does this run when the AC is running, too? Mine was installed without tje air sqirxh only runs when furnance us on. Is this normal?
@brianshimp8299
@brianshimp8299 Жыл бұрын
@@shanew7361 The REME Halo LED should turn on any time the air is being circulated in the home, both heating and cooling and even just fan on. However, it should not be on 24-7. The REME Halo LED does need to turn off and on in order to clean little brushes that you cannot see that are under the plastic cover on the end in the duct. This happens each time the unit turns on. Brian
@shanew7361
@shanew7361 Жыл бұрын
Brian Shimp So my contractor didn't install this properly cheaped out and were lazy. They did not install the air switch kit. Mine only functions when the furnace is running. They are coming out tomorrow to have a look. Suggestions on what to say and ask them? My furnace was replaced in October 2022 along with the Reme. Or does one not need the air switch for it to turn on during AC and heating? I got a Carrier 2 stage 125k btu.
@brianshimp8299
@brianshimp8299 Жыл бұрын
@@shanew7361 That Carrier gas furnace has EAC terminals that get 120 volts every time the fan in the furnace turns on. They can put a 120 volt coil relay on those EAC terminals and have the relay cycle the low voltage to the REME or they can install the air proving switch. Here are my comments from before that are accurate. If they don't like them, they can call RGF like I did. I have contacted RGF and spoke with the man that designs this system. He informed me that some EAC terminals do not put out proper HZ when first coming on and that can damage the REME. He wants all units installed with the transformer powered all the time and break the low voltage to the REME with an air proving switch or relay. He said if you always use the air proving switch, you won't have confusing different diagrams for your techs. Just get the line voltage right to the transformer and good to go. Hope it helps to make your case. Brian
@shanew7361
@shanew7361 Жыл бұрын
@brianshimp8299 Thanks. I screen shotted this information I will share with tech after his assumed diagnosis or lack of knowledge. You never know what shows up nowadays, lol
@MrMilanina
@MrMilanina Жыл бұрын
Just to keep the air circulating in my house I run the fan every hour for 30 minutes from 7AM to 10PM no matter whether the cooling or heating is on or off. Would using Halo LED be an option in such case or I should go with Reme HALO, possibly Zero? Thank you.
@robertpardo4346
@robertpardo4346 Жыл бұрын
How would you install this using the peanut relay that come with the Reme halo?
@unclegowron7262
@unclegowron7262 Жыл бұрын
The red indicator light on mine keeps turning off. Ive removed the unit, put it back in and the red light will come on for a while then go off again. Does this mean the bulb needs replaced or is there another issue?
@spidaboi2014
@spidaboi2014 Жыл бұрын
The problem is that it probably doesn’t have its own transformer or it’s powered directly that will kill them , wire it to the G
@mrdill7792
@mrdill7792 Жыл бұрын
Does it protect against the racisms? Protect yourself from yourself.
@Nmatenum420
@Nmatenum420 Жыл бұрын
Nice to see the good times being had 🎉
@rekinop
@rekinop Жыл бұрын
How to connect without air sensing switch?? Please help
@jeromelinnen3944
@jeromelinnen3944 Жыл бұрын
If you have a modulating furnace is it mandatory to use the air switch or can you connect it to the EAC? if you connect with the EAC do you have to use the relay?