Over sea discharge pipe line is blocked. So sludge is coming too much in lamila final tank over flow this is situation to handle etp too much difficult 😢
@yashvantkumar463Ай бұрын
What is the influence range of ept
@user-sm3bd3cn9wАй бұрын
We couldn’t understand ,you just read it
@khushichaturvedi4566Ай бұрын
You shouldn't put music while explaining something it hinders the concentration while studying.. Please reconsider
@satyaprakash40422 ай бұрын
Ariation tank kala ho ja raha hai
@satyaprakash40422 ай бұрын
SBR plant hai sir bar bar kala ho ja raha hai
@devkinandandumka33122 ай бұрын
SIR ETP mai lime aaur midea kitne time baad change hone chaiye
@harishankarghritlahare94892 ай бұрын
Sir yadi hum 500ppm ka kHP ko 10ml lekar cod testing krte hai to result sahi aayega kya?
@sachinghogare79482 ай бұрын
Sir you are giving very helpful knowledge for all employees they are working in etp,in water treatment plants. Make w.w.Analysis Procedure video all' parameters. Thanks all
@user-xu5nk4lg7u2 ай бұрын
Westage water Ammonia kaisa removed kar sakata chemical names used hota
@sujalpradhan74192 ай бұрын
👍👍
@ramjeetkumaryada2 ай бұрын
SV 30 KYA HAI
@ramjeetkumaryada2 ай бұрын
SV 30 kya hota hai
@ETPKnowledgeJunction2 ай бұрын
Sludge volume 30..means 30 minutes ke liye jo aeration tank ka sample hum settling ke liye rakhte hn taki ye pta kar sake ki 30 min me kitna sludge settle ho rha h
@chauhankundansinh93572 ай бұрын
Why 8000 used in formula ??
@sujalpradhan74192 ай бұрын
👍👍
@ETPKnowledgeJunction2 ай бұрын
🙏🙏
@littleishwari73842 ай бұрын
Aeration Tank pH above 9, how to maintain pH in aeration tank
@RajatGupta-xb6hm2 ай бұрын
Dose hcl
@gracefulheart79102 ай бұрын
Bhai, sirf questions padh kar uska hindi me Meaning samjha rahe ho. Quesn ka real answer kya dena hai, wo to bata nahi rahe ho.
@Callme_skm3 ай бұрын
Sir digester ka temperature aur pH kitna hona chahiye
@ETPKnowledgeJunction3 ай бұрын
For an anaerobic digester, the ideal pH typically ranges between 6.5 and 8.0, with 7.0 being neutral. As for temperature, it's usually optimal between 95°F to 100°F (35°C to 38°C). These conditions foster the growth of microorganisms responsible for breaking down organic matter efficiently.
@Callme_skm3 ай бұрын
@@ETPKnowledgeJunction thank you so much sir
@ShashankSharma-ly3to3 ай бұрын
Thank you sir, I still used to watch your old video for revision. Vey simply explained🫡
@ETPKnowledgeJunction3 ай бұрын
Ye hui na baat... ✌✌
@PardeepSingh-er5xb3 ай бұрын
Aeration tank me sv not settling 15000 / 16000 mlss sludge volume kise settle kar sakte hye g
@ETPKnowledgeJunction3 ай бұрын
15K .. 16K se MLSS ko 3500ppm pr leke aao.
@subratjatni3 ай бұрын
Sir, aerration tank capacity is 1500 kl, brewing company, how much quantity to add, kindly help me
@ETPKnowledgeJunction3 ай бұрын
Who's quantity??
@ETPKnowledgeJunction3 ай бұрын
Normally first dose is 10grams per KL of aeration tank volume and repeat dosage is 2 grams per KL of daily inflow KL on ongoing basis
@yashwinderkumar28633 ай бұрын
Sr ji Aeration tank 522kl ka hai kitna bayo culture dalege
@ETPKnowledgeJunction3 ай бұрын
Normally first dose is 10grams per KL of aeration tank volume and repeat dosage is 2 grams per KL of daily inflow KL on ongoing basis
@ajeetsinghyadav54953 ай бұрын
Bhai please soln btai jb sv 30 test lgate he to sludge time se pahle float ho ja rhi he
@ETPKnowledgeJunction3 ай бұрын
Ho sakta h SVI jayada ho.
@subratjatni3 ай бұрын
When I am draining the sludge the MLSS gets low still it not settling in secondary clarifiers Sv 30 is 980, MLSS is 3500 After draining the sludge MLSS is 2000 still not settling kindly guide me
@ETPKnowledgeJunction3 ай бұрын
Your SVI is too high i.e. 280 ml/g. Because SV30 is high but MLSS is ok. So, don't waste the sludge. Do some check points.. Maintain D.O. 1to 3ppm, dose N:P as per BOD:N:P= 100:5:1. Watch kzfaq.info/get/bejne/bdifjLRkz7O6dGg.htmlsi=3o_dTxhYrRM22stV.
@manojjha99213 ай бұрын
Holding tank me pH kam hone ke kya karan hai.
@ETPKnowledgeJunction3 ай бұрын
Holding time adhik hone se septic conditions bnti h jisse pH km hota h
@royalmaahi88gaming123 ай бұрын
Boi film cod के लिए महत्वपूर्ण भूमिका निभाता है क्या।।।।। और इसका इस्तिमाल mbbr नही किया जाता तो क्या इफैक्ट होता है।।।ple ans sir
@ETPKnowledgeJunction3 ай бұрын
MBBR, yaani Moving Bed Biofilm Reactor, ek prakar ka advanced wastewater treatment system hai jo biofilm ka upyog karta hai. Isme suspended plastic media ka istemal hota hai jo wastewater me suspend hota hai aur jis par microbes attach hokar biofilm banate hain. Ye biofilm pollutants ko degrade karte hain aur clean water ko produce karte hain. MBBR ke through, biofilm ka efficient growth hota hai jo treatment process ko enhance karta hai aur contaminants ko nikalne me madad karta hai.
@Allshortschannel20113 ай бұрын
Sir mere aeration pura polymar (chikana) ho gaya hai (paper industry) hai please help me
@ETPKnowledgeJunction3 ай бұрын
Please share your issue on the telegram group "etp knowledge junction "
@yaranayash35373 ай бұрын
❤
@ravipandit8773 ай бұрын
Sir filament kitna % hona chahiye Aeration tank
@ETPKnowledgeJunction3 ай бұрын
The percentage of filamentous bacteria in an aeration tank can vary depending on various factors such as the specific conditions of the tank, the type of wastewater being treated, and the efficiency of the treatment process. Typically, filamentous bacteria should be present in a balanced proportion within the microbial community to ensure effective wastewater treatment. However, specific percentages can vary widely. Generally, filamentous bacteria should not dominate the microbial population as it can lead to operational issues such as bulking and foaming. Regular monitoring and adjustment of the treatment process are necessary to maintain optimal microbial balance.