Пікірлер
@aircommuter
@aircommuter 5 күн бұрын
What about the brake resistor? It has three wires but no label. Both are Galt units.
@EkeminiSunday-wt6ye
@EkeminiSunday-wt6ye 24 күн бұрын
How do I program 2.2kw inverter on a 3 phase connections
@kevinmithnick9993
@kevinmithnick9993 Ай бұрын
nice info sr
@biplabacharjee477
@biplabacharjee477 Ай бұрын
Great explanation Sire
@brycejacobson4919
@brycejacobson4919 Ай бұрын
At the time of this comment, this video is now 9 years old. Do VFD's produced now in 2024 still pull current in the same "gulp" way? Do the new ECM (electrically commutated motors) and LED's we are retrofitting everywhere cause the same harmonics?
@bobbyyoung2831
@bobbyyoung2831 Ай бұрын
Very much appreciated. Covered a bunch of info in a short time. Thanks
@gerharddeale6506
@gerharddeale6506 Ай бұрын
Here in South Africa the black wire are always neutral or ground,, red yellow and blue are live wires
@paolocaso6734
@paolocaso6734 Ай бұрын
Where does the white wire go thst is coming from the 220
@philemonawoke
@philemonawoke 2 ай бұрын
please show me control wiring I am confused all ways please help me.
@AsgharAli-kx2if
@AsgharAli-kx2if 3 ай бұрын
Sir if there have no load on it how will ampere take
@AsgharAli-kx2if
@AsgharAli-kx2if 3 ай бұрын
Sir if there have no load on it how will ampere take
@sharkbaitsurfer
@sharkbaitsurfer 3 ай бұрын
That was a very accessible and easily understood and absorbed explanation, which takes real skill for what could potentially be a complex and difficult to understand topic - thank you
@thetruth7839
@thetruth7839 3 ай бұрын
From 9:00 it goes to 79 I do not have 19 to set my voltage
@ahmedbouroga7304
@ahmedbouroga7304 4 ай бұрын
@dimitra.d792
@dimitra.d792 4 ай бұрын
in an application with constantly start stop of three phase motor what is the better way so motor doesnt hot to coonect the inverter with triangle or star
@bashirusani5376
@bashirusani5376 5 ай бұрын
Haw can install my submasible pump 1.5 with ac drive model SG320~4k0GB~4T
@jovanmiletic
@jovanmiletic 5 ай бұрын
And how do you program it with the basics key pad?
@fed-upp8537
@fed-upp8537 5 ай бұрын
What type of VFD do hospitals normally use?
@skeets2409
@skeets2409 5 ай бұрын
Thank You!
@patrickmuleega1506
@patrickmuleega1506 6 ай бұрын
How can I program it without an outside control
@josegeorgekadakampallil8055
@josegeorgekadakampallil8055 6 ай бұрын
Thank you Sir
@alro7779
@alro7779 7 ай бұрын
You're explaining how to connect a single-phase VFD (L-N), but you ended up wiring it as a 2-phase (R-S) one! Why is that?
@SteneWoodwork
@SteneWoodwork 8 ай бұрын
So if I'm understanding this correctly, there is no neutral in the circuit, so the two power leads come from the double pole breaker, red into one pole and the black into the other pole? So I'd be pulling three wires, a ground, and two power leads and no neutral?
@justinsmith6860
@justinsmith6860 8 ай бұрын
You can convert the 800 series to 700 with a convertion kit, basically using a terminal Block from 700
@MikeZhadan
@MikeZhadan 9 ай бұрын
95% of electricians don't even know what vfd is.
@stinky8750
@stinky8750 5 ай бұрын
You sound stupid
@joeldwarika8356
@joeldwarika8356 9 ай бұрын
Brilliant 😊
@iacovacheiuliangheorghe64
@iacovacheiuliangheorghe64 9 ай бұрын
Hello, I also have an SP81 miniaturung, it has a 0.37 kw / 380 motor and I want to put a converter on it to go to 220v. Could I put a converter of 1kw or more on it?
@darlingsai9945
@darlingsai9945 10 ай бұрын
How to reslove EGF fault
@milbronjames
@milbronjames 10 ай бұрын
Thank you!
@D.Hozzie
@D.Hozzie 10 ай бұрын
Good stuff. Thanks for sharing.
@danielalemayehu4005
@danielalemayehu4005 11 ай бұрын
I have one invertor single phase input three phase out put new but no functional help me
@anelemngini4668
@anelemngini4668 11 ай бұрын
The controls not wired and thats the important thing as they are the ones which are not clear
@lombanibanda5954
@lombanibanda5954 11 ай бұрын
Nice teaching
@shahidrafiq8765
@shahidrafiq8765 11 ай бұрын
How to program for encoder feedback
@user-xx2wk6jp5d
@user-xx2wk6jp5d 11 ай бұрын
Hi can you please help i have a cross cut saw and need to put in a two way switch so that i can have it running continuously or on the hand button stop&start also i need to put in an emergency stop
@selvamramalingammudaliyar3867
@selvamramalingammudaliyar3867 Жыл бұрын
Also how to set parameter 168 & 169
@selvamramalingammudaliyar3867
@selvamramalingammudaliyar3867 Жыл бұрын
Sir I would like to how to syncronize three Mitsubishi FR A800 drives
@jakeblanton6688
@jakeblanton6688 Жыл бұрын
R= L1 S= L2 T= L3 N= Negative for DC Bus P= Positive for DC Bus P= ? U= T1 V= T2 W= T3 Would someone please explain to me what the second P stands for because Craig didn’t go over it. I would greatly appreciate it.
@Magneticitist
@Magneticitist 6 ай бұрын
Well this is 5 months late and you know the answer by now.. but for the record this is typically the 'P+' connection where a DC Link Choke would go. So the choke itself is what would bridge the P and P+ terminals in order to close the loop to the DC bus. If the choke is not present, a jumper needs to be there in order for the DC bus to charge.
@arifmalik6607
@arifmalik6607 Жыл бұрын
Sounds great
@dennisleazott718
@dennisleazott718 Жыл бұрын
Hi Craig . . . I would like to add a big red safety STOP mag switch with the VFD I am installing on a bandsaw (1.5hp / 220V 3P) to run off 220/1P. I can place it between the source and VFD or between the VFD and motor. Any recommendation on which method is best? Thanks, Dennis
@hasmukhvpatel4539
@hasmukhvpatel4539 Жыл бұрын
very well explain, thank you.
@maximochimfwembe5886
@maximochimfwembe5886 Жыл бұрын
AN FR-A700 INVERTER HAS DEVELOPED A PROBLEM OF ONLY RUNNING IN ONE DIRECTION(FORWARD) BUT PREVIOUSLY IT WAS RUNNING IN BOTH DIRECTIONS AND I HAVE CHECKED THAT THERE IS NO SIGNAL FROM THE INVERTER(AT RUN TERMINAL) GOING TO THE PLC .WHAT CAN BE THE PROBLEM.QUICK RESPONSE WILL BE HIGHLY APPRECIATED
@maximochimfwembe5886
@maximochimfwembe5886 Жыл бұрын
I HAVE REPLACED AN FR-A700 WITH AN FR-A800 AND ENTERED THE SAME PARAMETERS THAT WAS IN A FAULT A700 INVERTER BUT THE DRIVE IS NOT WORKING.WHY?
@prabhakargatreddi8617
@prabhakargatreddi8617 Жыл бұрын
Sir please do it settings video for 5hp submersible solar pump
@flacksonnkhoma8901
@flacksonnkhoma8901 Жыл бұрын
How about the one with dc in?
@user-hu4if6xw8p
@user-hu4if6xw8p Жыл бұрын
Thanks sir for this information.
@garbo8962
@garbo8962 Жыл бұрын
Never heard of 24 pulse drives but in a new building we had 18 pulse drives on all motors 40 HP & !arger except for a soft start in 250 HP fire pump Talked to drive techs from two different drive companies and neither liked any drives above plain Jane 6 pulse drives. Always had trouble with biggest boy on the block ABB tech support. Had to perform PM on over 100 ABB drives and contractor threw away all the books. Took me two weeks and maybe 5 emails for clowns at ABB to finally explain how to Bring up DC Buss voltage that we had to enter on our drive PM'S. Found Danfoss & Allen Bradley best for tech support.
@garbo8962
@garbo8962 Жыл бұрын
Maybe 6 months before I retired they installed two 1,750 HP chillers that 18' long cabinet was feed by 13,200 volts then to a transformer supplying 4,160 volts to the VFD. Never had training ing or saw them run. I asked where the NEC required arc flash labels were and they said thier engineering department were working in that.When I talked to one of my old coworkers a year later they still were working on labels. I would never approve of final payment for any lazy foot dragging company that did not supply required !abeling.
@KRIMEBOSS
@KRIMEBOSS Жыл бұрын
Question instead of connecting it with 480v how do I connect it using 230 v. what terminal do I use? Or is it not possible?
@KRIMEBOSS
@KRIMEBOSS Жыл бұрын
Craig I got a variable frequency driver that is 480V/3PH/ 60hz and I was wondering if you could connect it to 230V.